Saudi Aramco 2616-ENG (03/99)
SAUDI ARABIAN OIL COMPANY
5 1.1.1.10 Protection layer: Non-woven geotextile protection layer 300 gms./sq.m.
= over the thermal insulation board.
1.1.1.11Finishing layer: Concrete Tiles (3-lanes 40cm x 40cm x 4cm) from the
stairway, on walkway, to all area around AC units, first step & 1-lane all over
roof perimeter walls including the upper roof. Separated with non-woven
protection layer.
1.1.1.12 Remove & clean old-visible back rod, sealants for all vertical expansion
al. joints (parapet & retaining walls) and apply INSUWRAP bonding agents with
5/8 compressive strength of 6500 psi or approved equal.
iil2
ae 1.4.4.13 Wrapping of HVAC ducts, dressing around the drains, HVAC base, vents,
8 exhaust fan, Scuppers, pipe penetration with flushings & others as identified
5 during the actual inspection.
g 1.1.1.14 Seal to make watertight underneath AC Air Handling units, around the
2 parapets, skylights and any other roof penetrations of the entire roof.
é 1.1.1.15 Maintain the proper drain slope @ least 5%, drainage scupper, downspouts
and assure no blockages of any foreign materials.
a
J 4.1.1.16 Fabrication and installation of pre-cast roof drain scupper ~ 4 pcs each for
a3] & each school as required & necessary. (Quantity not used will be tumed over
ENGREE to SABGSD respective warehouses)
be 4.1.1.17 Repair and application of liquid membrane waterproofing to all concrete
re cracks on the parapet walls, joints, & other concrete structures on the roof.
Er
ae | 4.1.1.18 All materials needed has to be readied by Contractor and inspected by
CERTFED Saudi Project Engineer prior to actual work implementation.
FSi
one ava0z2
CORTREON 1.4.1.19 Roof flood test shall be conducted after the completion of the waterproofing
ne system and water supply to be provided by the contractor of at least 4 trucks
ee of sweet water (8000 Liters/truck) Per school as completed & inspected by
‘OPERATIONS SABGSD Eng’.
1.1.1.20Contractor has to provision corrugated metal deck of maximum 2% of the
S— total roof area, to be used for the replacement of any damaged metal deck
Lg within the roof. (Type P-3606 or approved equal) with nominal thickness of
ne Simm (Quantity not_used wil be tumed over to SABGSD respective
Ia El warehouses)
ERE ;
z é 1.1.2. The contractor shall visit the sites in order to know the schools locations, be able to
2 ze conduct field investigations, verify the accuracy of SOW and actual site conditions,
a |8 ; é gathered data to come up with accurate cost estimates.
Eres
Brgee
zii £6 |[Repcaccment or pve ROor system s'sscHooLs | ovore[prvo] wane] —ovamero [vrvo evn
S556) [ivsourieRn akea wo #703%2073 a
greeeg or
EFS EE [now SAUDI ARABIA | ore 8.
‘Saudi Aramco: Company General UseALMOAJIL CEMENT
PRODUCTS PLANT
G.R. 2050013464
mon fetes
FeO TEE cage
TECHNICAL DATA
Paving Tiles 400 x 400 x 40 mm Concrete Masonry Units Shall be produced
in Accordance with ASTM C90 with the following references:
CEMENT
COARSE
AGGREGATE
FINE
AGGREGATE
WATER
PRODUCTION
CURING
: Shall be ordinary Portland Cement conforming to ASTM C150
type 1 or type 5 specified.
: Shall be of natural Dense Stone Crushed and Graded to Size
conforming to ASTM C33
+ Shall be of Natural Dune Sand free from deleterious Materials,
Claylumps and Frayable Particles.
+ Shall be from the municipal water supply free from Oils, Acids,
Organic matter or other Deleterious Substances Excessive
Chloride Sulfates and Dissolved Solids Etc.
: Produced in Automatic Stationary Machine
: Cured in Curing Chambers by Heat and Moisture Treatment
Duration - 24 Hours.
For ALMOAJIL ‘GE!
ENG .NASSER A. AL QADER
PLANT MANAGER
NT RRODUCTS PLANT
SVT AE YYTs GaSb AEV PMT = ALY VAT oT ALY WAL: Ogduld — Qyagauadl dug pall ASLALI — TVEEY pla! WEA Aue
P.O. Box 1758-Dammam 31441 - Kingdom of Saudi Arabia Tel: 013 647-1794 / 847-2086 / 847-3903 Fax: 013 847-2260
mepp@eimosiiholding com / www almeaiiholding comAL HOTY-STANGER
TEST REPORT
1@ ——
tes Sample No, :3628-7
Soi Report No, 20/2038-7
‘TEST METHOD: BS 4131-73 Pageit 1 of 1
Client Name ‘AL MOAJIL CEMENT PRODUCT PLANT
‘Sample Doseripton Cement Ties
Nominal Size 400%400%40mm
Date of Received : 28.03.2021
Sampled by : Client
TEST RESULTS
Compressive Strength
Cutout specimen Compressive Stenght
Dimension Lx Wx Hmm) | Load (a) we)
40x40340 155 97
4040340 130 84
Tiorane HASSAN. 2 c :
Acting Department Manager Lab Supervisor
For Al HOTY.STANGER | TD CO
‘ro no to engi a a ope ha wl ave ef AKSL Wr bosry
"AL HOTY-STANGER LTD, CO.
INDEPENDENT LABORATORIES & MATERIALS TESTING
0. 00x:072AbHoebar 3052 To (01) 88 000/808 7808 7517 8 75/88 S27 Fe (08) 408.1468
Abst PO.467 Tt 0a) eb 870 Fo: (01)34-02- Hed PO, Bx 22 Te (13) 563210 Fo (19) 587-120 -Foyadn PO Bon TST 47-202 Fae (ATONE
“osha 825-01) 6024 Fax (012) 05 4742- York PO, Bon 9912 a (08) 22 5408 an (1) 21-747 = saz Wh (17518