Suzlon Energy Ltd.
What is DFIG?
Advantages of DFIG
Features of DFIG
DFIG Operation
What is DFIG?
Advantages of DFIG
Features of DFIG
DFIG Operation
• Slip ring induction generator directly connected to the grid and it uses a
capacitor bank Soft-starter ensures smother grid connection
• The rotor resistance is controllable and the power output is controlled
• The rotor resistance is changed by flexi slip concept
• The rotor controllable speed range is 0% to 16% over the synchronous
speed
Grid
Asynchronous generator
with slip rings
Grid
Asynchronous generator
with slip rings
Generator
Basically, a single speed Slip Ring
Induction Generators, similar to
the generator used in 1.5 MW & 2.1
MW with SFS turbines.
Grid
Asynchronous generator
with slip rings
Generator
Stator is connected to grid circuit,
similar to any other induction
generator
Grid
Asynchronous generator
with slip rings
Generator
Rotor windings are also connected to
grid, but through an AC-DC-AC
converter circuit.
Grid
Asynchronous generator
with slip rings
Converter
The rotor side converter is called as
machine side converter (MSC) and
the grid side converter is called as
line side converter (LSC)..
Grid
Asynchronous generator
with slip rings
Converter
Rotor circuit electronics capacity
would be around 30 % of the turbine
ratings.
Grid
Asynchronous generator
with slip rings
Grid
SFS
SFS
SFS
Grid
DFIG
Asynchronous generator with
slip rings
DFIG system
Advantages & Features
Variable
speed
operation
Variable
Reactive
speed
power
operation
regulation
Variable
Reactive
speed
power
operation
regulation
Fault
Voltage ride
through
Better grid compliance
Variable
speed
operation
Reactive
power
regulation
Eliminate the need
of capacitor bank
Capacitor Bank
Fault
Voltage ride
through
Better grid compliance
Fault
Voltage ride
through
Better grid compliance
DFIG converter
Designed for the latest grid code requirements
Only
applicable in
V1 Version of
DFIG panels
Line Side
Converter
(LSC)
Machine Side
Converter (MSC)
39
DFIG Training Module - Suzlon Internal Use Only
Main components in DFIG System
Suzlon Energy Ltd.
DC Link
capacitor
DC Link Capacitors
Pre-charging/Charging
Ckt
43
DFIG Training Module - Suzlon Internal Use Only
Main components in DFIG System
Suzlon Energy Ltd.
dv/dt
filter
dv/dt-Filter
45
DFIG Training Module - Suzlon Internal Use Only
Main components in DFIG System
Suzlon Energy Ltd.
CSC4
Crow Bar
ignition unit
(CSC-ZS)
Thyristors
DC Limiter
(Chopper)
DC-limiter (Chopper)
The operating ranges results from the specified slip limits. In general, the following relationships are
in effect :
Pre-charging DC link
After the threshold value is reached, the line contactor is switched ON and puts the mains voltage
to the reverse diodes of the LSC. Auxiliary contactor is switched OFF.
The DC-link is now pre-charged to UDC[V] = Vgrid*1.35
The converters are only pulsed when the machine speed is in the working range of Generator
RPM
For parameterized value of the DC-voltage, the line side converters are activated to maintain the
voltage
Synchronize, synchronization of
amplitude, phase and frequency