You are on page 1of 10

Busway Trunking System

Manufacturing center :
Add: No 3, Yuanbo Avenue, Economic development zone,
Yangzhong City, JiangSu province, China
Tel: +86-511-88136688 Fax: +86-511-88131655
E-mail: salesmegachina@optimus-busduct.com
website: www.optimus-busbar.com

Operation Center :
Add: 6th Floor , No 805, ZhengDe Rd., ZuoYing District , Kaohsiung City
813, Taiwan.
Tel: +886-7-3458385 Fax: +886-7-3421424
E-mail: vicara88@ms17.hinet.net
website: www.vicara-trade.com

OPT-EN-6-1712
PRO OPTIMUS

Introduction Mega Technology


contents
03 About Us
About Us
PRO Optimus busway trunking systems
possess strong R&D resource, perfect
qualityandsatisfactoryservice,whichhave
successfully completed many projects to
04 Certification o v e r s e a s a n d l o c a l m a r k e t . W i t h t h e
continuing product research and
05 Safety and Security development process carried out by Mega
Technology(Zhenjiang)Co.,Ltd,weareable
to provide uniquely designed and highly
06-09 Product Features reliable products. This is achieved by
adopting sophisticated thermodynamic
10 Product Range design applications and quality
manufacturing methods to deliver high
performanceproductstoourcustomers.
11 Electrical Characteristics
12-16 The Detail of The Accessories
17 Installation
18 Quality Policy
19 Function

3
Safety and Security Mega Technology
Certification

Waterproof intensify busway uses Epoxy coating and it has been
successfullytestedwithUL94V-0andsuccessfullypassed36cycle
thermal shock tests in accordance with IEC60068-2-14 and EU
ROHScertificate.

Earthquake Test
Test Report.

MEGA TECHNOLOGY(ZHENJIANG)CO.,LTD.
No. XMNMLC1701131002 Date: 15 Dec 2017. Page 1 of 3. PRO Optimus busway trunking system has
NO.3,Yuanbo Avenue,Economic Development Area,Yangzhong City,Jiangsu,China
.

Results and photos of this report refer to test report XMNMLC1701131001.


been successfully tested of 7.0 earthquake
strength  on three axissimulations of the
The following sample(s) was/were submitted and identified on behalf of the clients as : Epoxy powder.
SGS Job No. : XMIN170901891CCM - XM.
Date of Sample Received :. 15 Sep 2017.
Testing Period :. 15 Sep 2017 - 21 Sep 2017.

AC156,IBC2006andASCE7-05standard.
Test Requested :. Selected test(s) as requested by client..
Test Method :. Please refer to next page(s)..

Test Results :. Please refer to next page(s)..


Conclusion :. Based on the performed tests on submitted sample(s), the results of Cadmium,
Lead, Mercury, Hexavalent chromium, Polybrominated biphenyls (PBBs),
Polybrominated diphenyl ethers (PBDEs) and Phthalates such as
Bis(2-ethylhexyl) phthalate (DEHP), Butyl benzyl phthalate (BBP), Dibutyl
phthalate (DBP) and Diisobutyl phthalate (DIBP) comply with the limits as set by
RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU..

Signed for and on behalf of


SGS-CSTC Standards Technical Services Co ., Ltd. Xiamen Branch.

Sunny Lu.
Approved Signatory.

Fire Resistance Protection Test


Test P R O  O p t i m u s  b u s w a y  t r u n k i n g
P R O O p t i m u s b u s w a y system has been successfully  tested
trunking system has been for IP66 and IP68 in accordance with
successfully tested  for resistanceofIEC60529.
840℃in30minutesofthe
Full type test certificates of fire proof resistance in IPX6
PROOptimusbuswaytrunking accordance with JIS
system is in accordance with C8364, J IS A1304, CNS
I E C 6 1 4 3 9 - 6 : 2 0 1 2 a n d I E C 14286,andCNS12514.
60439-2:2005.

IP6X
IPX8

4 5
Housing

Product Features Mega Technology


※TheMetalhousingpassed PRO Optimus busway trunking systems are high heat
1,800hoursofsaltspraytest. dissipation, extremely low impedance ground path and
totally enclosed (sandwich type) in the powder coated
housing.Anyorientationofthesystemunderseveresite
conditionswillnotaffecttheperformanceofthebusduct.
GroundCapacity:50%or100%.
ProtectionIPDegree:IP40/IP42/IP54/IP55/IP65/IP66/
IP67/IP68.
Note : Protection of outdoor type can be provided upon special request
forcustomers.
Product Features

CS-S / CS-A Type AE Type

CS-S type:ColdrolledSteel AluminumExtrusionHousing


Electro-galvanisedSteel
CS-A tyep:AluminumAlloy
ERST ERSTN ERST ERSTN
3P+50%or100%HousingGround 3P+50%or100%InternalEarthBar
3P+100%or200%Neutral 3P+100%or200%Neutral

Using Environment Conductors


Height of the sea:indoororoutdoorsite TemperatureHeatRise,Copper TemperatureHeatRise,Aluminum
atanaltitudeof2,500mbelow. Copper busbars have LoadinAmps
Busway
Size LoadinAmps
Busway
Size
Humidity:indoororoutdoorsiteat high conductivity
relativehumidityof98%below. ( > 9 9 . 9 9 % ) w i t h h i g h
Ambient Temperature:indoororoutdoor purity(>99.97%),tinor
silver-plated.
Harmonic Suppression siteatbetween0℃to50℃.
Frequent Range :50or60Hz. Aluminum bars have
System Harmonic hazards to the busway
Voltage :1000Vandbelow. conductivity>58%~61%,
are mainly caused by the third harmonic
copper plated and tin or
neutralphase'soverload,accordingtothe
silver-plated for contact
contentofthethirdharmonicIh 3different,
aluminumsystem. 3150A

andwecantakedifferentsolutions: Reference Standards According to customerʼs


Ih3≤15% :Thecross-sectionalareaofneutral
PROOptimusbuswaytrunkingsystemsare request, we can provide
phase should choose h  alf cross- 1750A
testedandcertifiedbyKEMAKEUR,ULand the products which
sectionalareaofphaseline. 3Ctocomplywith: overload 25% and
Ih3≤33% :Thecross-sectionalareaofneutral IEC60439-1UL857 sustained 24 hours of
phase should be the same as highreliabilityproducts.
IEC60439-2UL1709
cross-sectionalareaofphaseline.
IEC61439-1/IEC61439-6ANSI
Ih 3 >33% :Shouldbeconsideredtoinstall TemperatureRise(AboveAmbient)(⁰C) TemperatureRise(AboveAmbient)(⁰C)
IEC60331/IEC60332IEE/IEEE
active or passive filter device As the line graph shown above, when rated current of 50 or 60 Hz flows in the
GB7251.1/GB7251.2NFPA70
intheharmonicbranch. PRO OPTIMUS Busway, the values of saturation temperature rise in the
CNS14286/CNS12514NEMABU1 conductorarenotmorethan55℃foranyratedcurrent.
JISC8364/JISA1304IEC60529

6 7
Product Features Mega Technology
The bridge type joint which is easy to install / remove,
providingoutstandingfeaturesasfollows:
Insulation Block Joint
The design of the joint assembly cone-shaped insulation
System platedesignincreasesmechanicalstrengthwhileitsmolded
(Bridge Type) jointsideplateensurescovernottodeform.

MicaFilm EpoxyCoating The steel large size of Belleville washers ensures average
MylarF
 ilm
pressureofcontact.
Use common 16 mm socket wrench to tighten the torque
Normal busway uses the whole wrap in Mylar film of the bolt. (When indication disc falls off, the joint is properly
Class B (130 ℃) or Class F(155 ℃), providing insulation tightenedautomatically).
anddielectricstrengthofupto15kV/mm.Thebuswayof Note:Useastandardtorquewhichis70Nmwhenthejointboltreinstall.
Product Features

riser configuration has been successfully tested for


Each joint allows thermal expansion of 5 mm, and allows
preventing flame propagation by IEC 60332-3 : 1992, 10mmfieldadjustableisolationforjobsiteflexibilityduring
G B / T 1 8 3 8 0 . 3 : 2 0 0 1 a n d f i r e b a r r i e r i n b u i l d i n g installation,allowingthetiltangleof±5,andallowsmore
penetrationofpreventingISO834. than40mmarealengthofoverlapping.
Fire rated busway uses the whole wrap in Mica film of Boltsandnutscanbestainless,galvanizedorchromedblack
insulatingmaterial,andhasbeensuccessfullytestedfor hightensilesteel.
840℃30minutesoffireproofresistanceofJISC8364,JIS The earth effect of the cable characteristic is more than
A1304,GA/T537,CNS14286,andCNS12514. 2
150mm electric.
Waterproof intensify busway uses Epoxy coating of the The temperature rise sensors can be purchased according to
ClassB(130℃)orClassF(155℃)orClassH(180℃),has customerneedstoexamineifthejointsoverloadoroverheat.
beensuccessfullytestedforIP68protectionofIEC60529
andcomplybyUL94V-0,EUROHS.
Note:Allbusductsaretestedat2.5kV/3.75kV/5kV/6.5kVfor1
minuteand≥ 2000MΩinthetestingconditionofthefactory. Temperature monitoring technology system

Morethan60,000
thermometrypoints.

※Customerscanchooseaccessories.
Detail of The TemperatureSensor
Block Joint Sticker Displaysdetailsofeach
temperaturenode
ServiceBackground

JointCover SideCover
80

(IP55andabove)
RS485 communication

PhaseInsulationPlate
Receivingdisplayterminal Receivingdisplayterminal
ConnectingConductor Indicator
Twin-Head
BackingPlate
ShearOffBolt
BellevilleWasher BackingPlate 80 RS485
communication
RS485
communication
PhaseInsulationPlate
LockNut ConnectingConductor Note:When the temperature rise is
excessively high, the color will
change and the demonstrate
digit, in the normal condition,
FiberTube
when reaching 80℃, must reduce Temperature Temperature Temperature Temperature Temperature Temperature
thepowerstrengthoverhaul. measuringpoint measuringpoint measuringpoint measuringpoint measuringpoint measuringpoint

SideCover JointCover Maximum1024temperaturemeasuringpoints. Maximum1024temperaturemeasuringpoints.


※Customerscanchooseaccessories.
(IP55andabove)

8 9
Electrical Characteristics Mega Technology
FeederBusduct 135
6
135
6
Ambient Temperature
-6
Unit:10 Ω/m(20⁰C) Application
H W W Rating BusbarSize 50Hz 60Hz W h e n  i n s t a l l e d  i n  h i g h e r
(A) (mm) R X Z R X Z ambient  temperature,  the
H 400 25 123.5 56.3 135.7 123.5 67.8 140.9 busduct current rating shall be
Fig.CS-1 630 35 86.9 44.6 97.7 86.9 53.7 102.2 decreased according to the
W
800 45 67.0 34.2 75.2 67.0 41.2 78.7 factorsforthefollowingtable:
3000mm(Standard) 1000 60 50.0 27.9 57.3 50.0 33.6 60.2
AmbientTemperature
500mm(Minimum) Fig.CS-2 1250 75 40.0 32.6 51.6 40.0 39.3 56.1 0 DeratingFactor
( C)
1350 85 35.0 29.8 46.0 35.0 35.9 50.1
Product Range

40andbelow 1.00

CUConductor
1600 100 30.0 24.4 38.7 30.0 29.4 42.0 45 0.95
1750 125 23.7 21.2 31.8 23.7 25.5 34.8 50 0.90
2000 160 19.8 13.2 23.8 19.8 15.9 25.4 55 0.85
135 60 0.80
6 2500 185 16.2 12.9 20.7 16.2 15.5 22.4
65 0.78
3150 250 12.6 8.2 15.0 12.6 9.9 16.0 70 0.74
3200 (2)125 12.6 7.8 14.8 12.6 9.4 15.7 80 0.70
135 W
6 3500 (2)140 10.9 7.3 13.1 10.9 8.8 14.0
H 4000 (2)160 9.5 6.8 11.7 9.5 8.2 12.5
4500 (2)205 7.4 6.4 9.8 7.4 7.7 10.7
H W W 5000 (2)225 6.7 5.8 8.9 6.7 7.0 9.7
6300 (2)250 6.1 5.0 7.9 6.1 6.0 8.6

Fig.AE-1 Fig.AE-2
400 50 98.6 42.0 107.2 98.6 50.6 110.8 Short-circuit current
630 60 81.8 35.2 89.1 81.8 42.4 92.1
withstand
800 75 66.9 25.8 71.7 66.9 31.1 73.8
1000 90 54.9 23.2 59.6 54.9 28.0 61.6 PRO Optimus busway trunking
Rating W H
CS-SType H CS-AType H AEType 1250 110 44.2 19.1 48.2 44.2 23.0 49.8 systems provide predictable,

ALConductor
Weight(kg/m) Weight(kg/m) Fig Weight(kg/m) Fig
(A) (mm) (mm) (mm) (mm) 1350 150 33.3 15.9 36.9 33.3 19.2 38.4 consistent strength and high
3P3W 3P3W 1/2E 3P4W 3P4W 1/2E 3P3W 3P3W 1/2E 3P4W 3P4W 1/2E 3P3W 3P3W 1/2E 3P4W 3P4W 1/2E
1600 170 29.1 14.8 32.6 29.1 17.8 34.1 short-circuitratings.
400 25 57 10 11 12 12 57 8 8 9 10 85 9 9 10 11
12 13 14 15 67 10 10 11 12 10 11 12 13 2000 200 24.2 11.9 27.0 24.2 14.3 28.1
630 35 67 95
2500 (2)150 16.1 8.9 18.4 16.1 10.7 19.3 Testing is certified by KEMA , in
800 45 77 14 15 17 18 77 11 13 14 15 105 12 13 15 16
1000 60 92 17 19 20 22 92 14 16 17 19 120 15 16 18 20 3200 (2)170 14.2 6.6 15.7 14.2 8.0 16.3 accordancewithIEC60439-1&2
1250 75 107 20 22 24 26 107 17 19 21 23 135 18 20 22 24 3500 (2)185 13.1 6.2 14.5 13.1 7.5 15.1 andIEC61439-6ofshortcircuit
1350 85 117 22 24 26 29 117 18 21 23 25 CS-1 145 19 22 24 26 AE-1 4000 (2)200 12.1 6.0 13.5 12.1 7.2 14.1 withstandtestfor1secondand
CUConductor

1600 100 132 25 27 30 33 132 21 24 27 29 160 22 25 27 30 4500 (2)225 10.7 5.4 12.0 10.7 6.5 12.5 3seconds.
1750 125 157 29 33 36 39 157 26 29 32 36 185 26 30 33 37 5000 (2)250 9.7 4.8 10.8 9.7 5.8 11.3
2000 160 192 36 40 45 49 192 32 36 41 45 220 33 37 41 46
Note:Voltagedrop=ampsloadx√3x(RcosΘ+XsinΘ),cosΘ=PowerFactor
2500 185 217 41 46 51 56 217 36 41 46 51 245 37 42 47 52
3150 250 282 53 60 67 73 282 48 55 62 68 310 49 55 62 69
3200 (2)125 295 58 64 71 78 290 51 57 64 71 318 52 58 65 72
3500 (2)140 325 63 71 79 86 320 56 63 71 79 348 57 64 72 80
4000 (2)160 365 71 79 89 97 360 63 72 81 89 388 64 73 82 90
CS-2 AE-2
4500 (2)205 455 88 99 110 121 450 79 90 102 113 478 80 91 103 114
5000 (2)225 495 95 107 120 132 490 86 98 111 123 518 87 99 112 124
6300 (2)250 545 105 118 132 146 540 95 109 123 136 568 96 109 124 137
400 50 82 10 10 10 11 82 7 7 8 8 110 7 8 8 9
630 60 92 10 11 11 12 92 7 8 8 9 120 8 9 9 10
800 75 107 11 12 13 13 107 8 9 10 10 135 9 10 10 11
1000 90 122 13 13 14 15 122 9 10 11 12 150 10 11 12 12
CS-1 AE-1
1250 110 142 14 15 16 17 142 11 12 13 13 170 11 12 13 14
ALConductor

1350 150 182 17 18 20 21 182 13 15 16 17 210 14 15 17 18


1600 170 202 19 20 22 23 202 15 16 18 19 230 15 17 19 20
2000 200 232 21 23 25 26 232 17 18 20 22 260 18 19 21 23
2500 (2)150 345 34 36 39 41 340 26 29 31 34 368 27 29 32 35
3200 (2)170 385 37 39 43 46 380 29 32 35 38 408 30 32 36 38
3500 (2)185 415 39 42 46 49 410 31 34 37 40 438 32 35 38 41
CS-2 AE-2
4000 (2)200 445 41 45 48 52 440 33 36 40 43 468 34 37 41 44
4500 (2)225 495 45 49 53 57 490 36 40 44 48 518 37 41 45 49
5000 (2)250 545 49 53 58 62 540 39 44 48 52 568 40 44 49 53

10 11
The Detail of The Accessories Mega Technology
A

B OneTrunk
A
Flange End
C
DIA11 DIA14xL21
B 20 20 20
40 P P 40 P S P 40 P S S P
300
20 20 20
W W W

Flatwise Elbow Flatwise Offset A


Fig.1 Fig.2 Fig.3
StandardLength StandardLength
Rating(A) Rating(A)
(mm) (mm) 170
DoubleTrunk
400-3150 A/B=350 400-3150 A/C=350,B=300
CU 3200-4000 A/B=450 CU 3200-4000 A/C=450,B=300
The Detail of The Accessories

4500-6300 A/B=550 4500-6300 A/C=550,B=400 DIA14xL21


400-2000 A/B=350 400-2000 A/C=350,B=300 20 20
40 P S P P S P 40 P S S P P S S P
AL 2500-3500 A/B=450 AL 2500-3500 A/C=450,B=300 20 20
4000-5000 A/B=550 4000-5000 A/C=550,B=400 W W W W
G G
Fig.4 Fig.5
B
Dimension(mm)
Rating
AEType/CS-AType CS-SType Fig
(A) W S P
D
Edgewise Elbow 13
400 25 - 12.5
G
-
A
111
B
55
G A
- 111 55
B

13
630 35 - 17.5 - 121 65 - 121 65
A B Mounting Opening 800 45 - 22.5 - 131 75 - 131 75
1
Phase Interval Dimension Dimension 1000 60 - 30 - 146 90 - 146 90
“a”(mm) “C”(mm) “D”(mm) 1250 75 - 37.5 - 161 105 - 161 105
80 250 230 1350 85 - 42.5 - 171 115 - 171 115

CUConductor
3W
100 310 290 1600 100 50 25 - 186 130 - 186 130
80 350 280 1750 125 60 32.5 - 211 155 - 211 155 2
4W
100 410 340 2000 160 80 40 - 246 190 - 246 190
Rating(A) StandardLength(mm) 2500 185 60 32.5 - 271 215 - 271 215
CU 400-6300 3
A/B/C=350 3150 250 80 45 - 336 280 - 336 280
AL 400-5000 3200 (2)125 60 32.5 8 344 288 13 349 293
3P3W 3500 (2)140 80 30 8 374 318 13 379 323 4
Edgewise Offset 4000 (2)160 80 40 8 414 358 13 419 363
A 4500 (2)205 60 42.5 8 504 448 13 509 453
C C
5000 (2)225 80 32.5 8 544 488 13 549 493 5
B 6300 (2)250 80 45 8 594 538 13 599 543

E E
a a a a a a Dimension(mm)
Rating
AEType/CS-AType CS-SType Fig
(A) W S P
C
50%/100% 50%/100%PE G A B G A B
400 50 - 25 - 136 80 - 136 80
(HousingGround)
630 60 - 30 - 146 90 - 146 90
1
800 75 - 37.5 - 161 105 - 161 105

3P4W 1000 90 - 45 - 176 120 - 176 120


1250 110 50 30 - 196 140 - 196 140

ALConductor
1350 150 80 35 - 236 180 - 236 180 2
A
C C 1600 170 80 45 - 256 200 - 256 200
B 2000 200 60 40 - 286 230 - 286 230 3
2500 (2)150 80 35 8 394 338 13 399 343
C 4
3200 (2)170 80 45 8 434 378 13 439 383
Combination Elbow E E 3500 (2)185 60 32.5 8 464 408 13 469 413
a a a a a a a a
Rating(A) StandardLength(mm) 4000 (2)200 60 40 8 494 438 13 499 443
5
400-3150 A/B/C=350
50%/100% 50%/100%PE 4500 (2)225 80 32.5 8 544 488 13 549 493
CU 3200-4000 A/B=350,C=450 5000 (2)250 80 45 8 594 538 13 599 543
4500-6300
(HousingGround)
A/B=350,C=550
400-2000 A/B/C=350
AL 2500-3500 A/B=350,C=450
4000-5000 A/B=350,C=550

12 13
The Detail of The Accessories Mega Technology
a ca
Plug-in Busduct and W
D
Plug-in Unit b 0N

Ratingof BoxSize(mm) Pullto Pullto


Disengage Disengage
MCCB a b ca H W D
MCCB MCCB
75 130 90 400 250 220
100A TopView FrontView SideView
90 155 112 400 250 250
105 165 92 400 250 220
100A/250A Tap-offUnit Plug-inBusduct
105 165 112 400 250 250
140 343 132 550 320 320
400A
140 343 155 550 320 350
The Detail of The Accessories

630A 210 449 155 680 420 360 Plug-inOutlet


H (SpareHole)
Note: The plug-in box size decided upon the
brandofMCCB. Turnright Clamp
toclose
(RecommendedBrand:Shihlin) thebreaker

Flatwise Tee Edgewise Tee


FrontView SideView
StandardLength Removableof
Rating(A) (mm) TheReserve
A Tap-offUnit
400-2000 A/B/C=400
2500-3150 A/B/C=450
CU 3200-4000 A/B/C=500
Tap-offunit(plug-in)protection:IP2X/IP40/IP42/IP54/IP55.
4500-5000 A/B/C=550 C
A
6300 A/B/C=600 Plug-inholeconductorwithtinorsilverplated.
B
Tap-off units with non-fused circuit breakers (MCCB) or fused-switch breakers of various
StandardLength
B Rating(A) (mm) currentratingsareavailableforcateringtomostinstallations.
C 400-1250 A/B/C=400 Maximumfive(5)tap-offunitsperfacecanbeinstalled,totalten(10)nosperlengthof3m
Rating(A) StandardLength(mm)
1350-2000 A/B/C=450
CU 400-6300 busductpendinguponthesizeofMCCBS.
AL 2500-3200 A/B/C=500 A=600,B/C=450
AL 400-5000
3500-4000 A/B/C=550 Tap-offunitsareinterlockedtopreventremovalwhenoutgoingdeviceisin“on”position.
4500-5000 A/B/C=600
Whenthetap-offunitcoveris“open”,itisinterlockedthatMCCBcannotbeturned“on”.

Plug-in Unit (Bridge Type)


Ratingof BoxSize(mm)
Expansion Unit Reducer Unit Phase Transposition MCCB D D
H W
Unit 800A 900 420
(ManualOperation) (ElectricOperation)
320 300
1000A 1050 420 300 400
1200A 1050 450 300 400
L 1600A 1150 500 300 400
L L

H
D

Rating(A) StandardLength(mm) Rating(A) StandardLength(mm) Rating(A) StandardLength(mm)


400-6300 L=1200±25 400-6300 L=1000 400-6300 L=1200

Note:1.Canbeinsertedintotheconnectorinpoweroncondition.
2.Withelectric/manualoperationON-OFF.
3.The plug-in box size decided upon the brand of MCCB.
(RecommendedBrand:Shihlin)

14 15
Installation Mega Technology
Horizontal Support Vertical Spring Hanger
End Feed Box Rating
(A)
Copper
A(mm)
Rating
(A)
Aluminum
A(mm)
400 210 400 235 HangerRodM12
630 220 630 245 (Supplybytheother)
800 230 800 260 1500~2000mm SelfDrillingSerew
300 1000 245 1000 275
A
1250 260 1250 295
1350 270 1350 335 ʻUʼChannel(75x50mm)
(Supplybytheother)
1600 285 1600 355
The Detail of The Accessories

400/460 1750 310 2000 385


400 2000 345 2500 Contactwith BusductClip
2500 370 andabove thefactory
3150 435
3200 Contactwith
ʻLʼangle(38x38mm)
andabove thefactory
(Supplybytheother)

270
230 DIA14
38
EndCover TopView

M12x150

End Cover 220


80
End covers are used
a t  t h e  e n d s  o f M10x30
Busway FrontView SideView
distributionfeeders.
T h e y  a r e  u s e d  t o
e n s u r e  t h e  w h o l e
s y s t e m  w h i c h  i s Minimum Space Required for Minimum Space Required for
devoid of exposed
Horizontal Installation Vertical Installation
liveparts.
Ceiling Ceiling Ceiling Ceiling

Tap-OffUnit
Copper Aluminum
Floor / Wall Flange Rating
A(mm)
Rating
A(mm) D
D D
D

(A) (A) Wall Wall


CS-SType CS-AType AEType CS-SType CS-AType AEType
C
400 175 175 205 400 200 200 230 C
630 185 185 215 630 210 210 240
800 195 195 225 800 225 225 255 D
D
255 1000 210 210 240 1000 240 240 270
1250 225 225 255 1250 260 260 290
Wall Wall
1350 235 235 265 1350 300 300 330 D D
D D
1600 250 250 280 1600 320 320 350 Floor Floor
1750 275 275 305 2000 350 350 380
2000 310 310 340 2500 465 460 490 C W
A 2500 335 335 365 3200 505 500 530
3150 400 400 430 3500 535 530 560
3200 415 410 440 4000 565 560 590 Note:D=100mm,“D”representsthedistance fromtheedgeofbetween thebusway andthewall.
3500 445 440 470 4500 615 610 640 C=250mm,“C”representsthedistance fromthecenterofthebusway.
4000 485 480 510 5000 665 660 690
W=350~600mm,accordingtotheratingoftheplug-inunitdeterminesthedistanceofthebuswaycenter.
4500 575 570 600
5000 615 610 640
6300 665 660 690

16 17
Function Mega Technology
ISO9001 ISO14001 ISO18001
Shopping
Malls
EndCover
Skyscraper/Hotel
Quality Policy

EndCover

VerticalPlug-in EndCover
Busduct

Tee-Section

HorizontalFeeder
Plug-inUnit Busduct

Reducer EdgewiseElbow
Tee-Section

EndCover

HorizontalPlug-in
Busduct
FlatwiseElbow
OffsetElbow

VerticalSpring Horizontal FlatwiseElbow


ITPlant/DataCenter
Support Hanger

EndFeedBox

VerticalFeeder
Busduct ResidentialBuilding
Cables

FlangeEnd

produce measure FlexbleCable


Switchboard

inspect service

Substation
Center
18 19

You might also like