You are on page 1of 1

Project 1

05 / 30 / 2022

Operator
Telephone
Fax
e-Mail

B1-HR Team / Single Sheet Output

Height of Room: 10.000 ft, Mounting Height: 10.000 ft, Light loss factor: 0.80 Values in Lux, Scale 1:64

Surface U [%] Eav [lx] Emin [lx] Emax [lx] u0


Workplane / 453 247 549 0.547
Floor 20 378 230 458 0.608
Ceiling 80 120 89 149 0.746
Walls (4) 50 278 113 521 /

Workplane:
Height: 2.493 ft
Grid: 128 x 32 Points
Boundary Zone: 0.000 ft
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.660, Ceiling / Working Plane: 0.265.

Luminaire Parts List

No. Pieces Designation (Correction Factor) ) [lm] P [W]


1 8 Pierlite PLPL2245 NW (1.000) 3250 40.5
Total: 26002 324.0

Specific connected load: 0.99 W/sq ft = 0.22 W/sq ft/100 lx (Ground area: 328.91 sq ft)

Page 1