You are on page 1of 2

ESTIMATING STEEL BARS AND TIE WIRES

mag insert lamang po dito :)


FOOTING (without bending) COMPUTED QUANTIT
steel length # of footings ftg width (w) ftg length (l) ftg thickness cut size (w)
6 9 2 2 0.3 1.85
steel bars weight as
per
# of bars (w) # of bars (l) vol (cu.m) diam. of bar # of pcs
ASTM A 615:1995 6 6 10.8 12 4

FOOTING (with bending) COMPUTED QUANTIT


steel length # of footings ftg width (w) ftg length (l) ftg thickness cut size (w)
9 8 1.2 1.2 0.25 1.35
steel bars weight as # of bars (w) # of bars (l) vol (cu.m) diam. of bar # of pcs
per
ASTM A 615:1995 5 5 2.88 16 2

COLUMN COMPUTED QUANTIT


steel length # of columns # of bars column height diam. of bar pcs from bar
9 8 6 4.35 16 2.07
steel bars weight as . no. of tie wire note: if two different bar size is used, simply
# of pcs
per ASTM A
compute bars separately
615:1995
34 1632 48

BEAMS COMPUTED QUANTIT


steel length # of beams # of bars beam length diam. of bar pcs from bar
7.5 1 4 4.00 16 1.88
steel bars weight as # of stirrups no. of tie wire note: if two different bar size is used, simply # of pcs
per ASTM A
compute bars separately
615:1995 31 124 4
D TIE WIRES

COMPUTED QUANTITY
cut size (l) #16 g.i.wire(kgs)
1.85 2.00
total bar pcs total kgs of bars
36 192.24

COMPUTED QUANTITY
cut size (l) #16 g.i.wire(kgs)
1.35 1.00
total bar pcs total kgs of bars
16 151.68

COMPUTED QUANTITY
piece you get #16 g.i.wire(kgs)
2 9.24
total bar pcs total kgs of bars
24 341.28

COMPUTED QUANTITY
piece you get #16 g.i.wire(kgs)
1 0.70
total bar pcs total kgs of bars
4 47.40

You might also like