You are on page 1of 17
i STOIRZ Technische Unterlagen KARL STORZ — ENDOSKOPE Service Instruction OP PNEU ELECTRONIC 26 020 his paper work is mental property of Messrs. KARL STOR2 Gmbil # Co. and it 1s not allowed to copy or to hand over to third parties. he possession of these manuals does not authorize the user to repair the unit. All service performance, like changes, repair work, colibration ean be done only by Messrs. KARL STORZ Gubi § Co. oF persons specially authorized by us. Opening of the unit and repair-work done by not authorized persons set us free of any responsibility for safety of the unit. Diese Unterlagen sind geletiges Eigentum der Firma KARL STORZ GMBH 4 CO., und dUrfen weder kopiers noch an Dritte weitergegeben werden. Die Verfugbarkeit Ober diese Unteriagen stellt fUr den Benutzer keine Autorigierung durch den Gerdteherstel. der entaprechenden Gerate éar- e tur Reparatur Stintliche Service-Leiscungen wie Xnderungen, Reparaturen, Kalibrierungen etc. dlirfen nur durch aie Firmal KARL STORZ GMBH & CO Tuttlingen oder durch von Shr autorisierte Fachkrifte vorgenommen verden. Eigenndchtiges Béfnen des Apparates und durch Frende durchgefinrte Reparaturen ent~ binden uns von jeglicher Heftung fUr die Betriebssicherneit des Gerdtes. Ttem Designation * | No. of order az | Piece 1 cover * '7050-01-00-11N EA 1 ao hexagon nut. IMé DIN934 ra | 9 3 tooth lock washer JAS, 3 DIN 6797 EA 14 4 cable bracket ip 4 EA 3 5 hexagon nut IMé DIN 934 ral 6 6 tooth lock washer |A6, 4 DIN 6797 EA 7 7 bottom '7050-02-00-11N EA L 8 rubber-bonded-to-metal foot {7100-00-24-41K EA 4 9 spacer block |7050-00-12-42N EA 2 10 raised countersunk head screw|4,2x13 DIN 7983 EA 6 1 rear panel '7050-26-00-21K SE L 2 cap nut IMé DIN 917 ra | 4 B appliance plug '0s0-31-00-91« se] i 4 cross recessed head screw [M3x15 DIN 965 EA a 1s tooth lock washer |A3, 2 DIN 6797 EA 9 16 hexagon nut M3 DIN 934 EA 3 17 earth conductor sign |1110-00-21-91K cA 1 18 cable bracket 0 6 EA 3 1g washer \6,4 DIN 125 EA 3 20 pot compensating stud |7500-00-06~41N mal 2 au container for spare fuses . |1110-17-00-91N se | 2 22 » fuse jl AT for 220 V or EA 4 . fuse 2 AT for 110 V EA 4 23 printed circuit board with heat sinks |7050-28-00-41N- SE i 24 spanner bolt 5 DIN 933 EA 4 25 tooth lock washer ts, 3 DIN 6797 ER Ttem Designation No. of order BZ Piece 26 washer 5,3 DIN 125 EA 4 27 stirrup piece 7100-00-25-41N |EA 1 28 jwasher 5,3 DIN 125 Ku |EA, 2 29 |pop-bl ind-rivet GFB-Nr. 304 472 JEA 6 30 lcylinder head screw M3x12 DIN 84 1 31 lwasher 3,2 DIN 125 ks 6 32 tag block 7050-18-00-91K SE & 33. |copper wire 9 1,5x45 mm in length BA | 2 34 |cable clamp size 4 lea | 35 transducer 7050-04-00-91K |SE 1 36 measure throttle 7050-07-00-41N ISE L 37 measure tube 7050-22-00-91N ISE L 38 Inolding device 7050-00-16-31N IEA L 39 capacitor Tantal lea 2 40 |resistor 5,11 koh 1/4 W fra | 1 41 Jpop-bl ind-rivet |GFB-No. 304 372 A L 42 lspanner bolt M4X10 DIN 933 2 43 jwasher 4,3 DIN 125 E 16 44 c02-cylinder-fitting Swiss system 9923 ss | 2 45 jco2-cylinder-fitting Kernan system 9920 SE 46 |. washer 9931 BA 47 ko2-cylinder-fitting [PIN IND e921 BE 1 48 |. washer 9931-1 FA 1 49 po2-cylinder-fitting ps model jo922 BE 1 50 stiffening plate \7100-00-05-43N EA 1 sl put [7100-00-06-41N FA a Item Designation © No. of order | 8 Piece 52 copper wiring 1110-00-14-41N iss [1 537 pressure reducer 0,8 bar 7100-10-00-25N Ise |. 34 T-piece 7100-19-00-41N IEA | 55 safety valve 1,1 bar 7100-25-00-42N se | 56 Pressure regulator 50 mig | 7050-16-00-31N, Ise | a 57 pressure regulator 10 mig | 7050-15-00-31N Iss} 2 58 distance roll 7050-00-04-41N lea | 2 58 magnet valve 7050-14-00-S1N se | 60 cylinder head screw M3x8 DIN 84 fa |2 61 magnet valve 7050-12-00-91N Jee Ja 62 spanner bolt Max8 DIN 933 fea |4 63 mounting plate 7050-00-17-21N = ofa |e 64 printed circuit board only in exchange | together with pos. 35 | 6 rod 7100-00-14-42N fea [4 66 copper wiring 7050-32~00-41N jse | 1 67 copper sealing 7100-00-19-21K a | t 68 front panel 7050-00-13-21K A 2 68 manometer (reserve) 7100-09-00-S1K se [2 70 handle 7100-00-08-41N A | 2 a turning knob 7100-00-11-44N se |. R flow meter 7050-35-00-41N Ise} a B connection nipple 7050-00-06-41N fra |. 14 Indicator knob 7100-00-10-41N Ise | a 5 disc (washer) 9931-1 len | 2 76 mains switch 4610-12-00-91K Ise 12 7 cap 1610-12-01-91K eA |. abezuy yur Gunsanays aps; ‘ayps0}-s09 < Syuruos | soqe'or'y uy LL? (ae a eel dnuaayoyps: faa die sae | rit yanpuny — 220puI png pra 409091 101308 S2woUDH Item Designation No. of order 82 Piece 78 potentiometer 7050~06-00-91K se 1 73 indication glass 7050-00-14~41K fA] 1 80 indication glass 7050-00-14~42K fea | 3 81 distance hull 7050-0C-18-41K ja | 4 82 distributor 7050-05-00-42N | |se | 2 83 IED yellow TLU ¥ 5400 | jr fa 84 holding device 7050-00-15-41N |. 85 throttle 71.00-16-00-41N fse fa 86 hexagon nut Mi2x0,75 ra] 1 87 washer 10,5 DIN 125 FA | 4 88 tooth lock washer A10,5 DIN 6797 jm | 4 89 hexagon nut Muox1 DIN 934 fm | 2 90 regulation valve }7100-05-00-33N [se pt 91 - countersunk head screw M2310 DIN 63 [ma] 4 92 « micro switch 7100-05-13-91K ise | 2 93 + hexagon nut M2 DIN 934 cfm | 4 94 socket connector DIN 41 617 cfm fa 95 socket ridge 10pol. '7050-34-00-91K lm fa 96 socket ridge 15pol. 7050~34-00-92K ya fa 7 spanner bolt IMi0x30 Din 912 BA | 2 98 cable protecting sleeve {8000-00-22-91K EA | 2 99 distributor nipple 1650-07-00-41N se | 2 100 magnet valve 7050-11-00-S1N sz |. 101 stud screw IMax12 DIN BA | 2 102 rubber-bonded-to-metal- | mounting 11650-00-12-91K ra | 2 103, spanner bolt IMax6 DIN 933, za | 2 104 transformer 7050-30-00-91K se] 1 105 cylinder head screw M4x10 DIN 84 EA | 4 106 cable clamp size 3 ra | 2 O20 92 + sowie 26020 CO OP-PNEU TEST PROCEDURE- Set up unit under test as shown below: Page 2. Turn power on and warm up unit for about 10 min. Open C02 supply valve. The meter 1 pointer should be within the green zone. Clamp the Sho-Rate (#99961) flowmeter. Set the insufflation control 12 to 1 LPM position and observe the following: a. Pressure meter 4 LED should read 62 to 50 mmHg and the Pennwalt #99941 pressure gage should read the same pressure within +2 mnig. b. LED 10b should light up and the tone "beep beep - should be heard. c. Intra-abdominal perssure LED meter 11 should read the same as meter 4 within 42 digits. 5. Set pressure control knob (3) to 12. Remove the clamp from the Sho-Rate (#99961) flowmeter and observe the following: a. Mechanical insufflation indicating ball should hover between the mark lines or near the upper end of the glass tube. b. Pressure meter 4 should read 2-5 mmiig. c. Flow meter 6 should read 1 LPM +10%, and the Sho-Rate (#99961) should read .9-1.2 LPM. 4. LED 9, 10a should light up intermittently and signaling correct function measurement and insufflation phase. ©. Meter 11 should read 00. 6. Have a timer ready. a. Reset meter § by pressing the reset button switch 7. count for 1 min. The meter 5 should read 1 LPM +10%. 7. Turn volume knob 3 slowly to between 2-8. The green LED light 10 should light up. 8. By using the fingers, block the outlet tubing to stop the insufflation. The LED 10b should light up and the tone beep beep" ---- should be heard. 9. Set insufflation switch 12 to Hi-flow position for a few seconds and observe the following a. Sho-Rate (#99961) flowmeter should read 5-6 LPI b. Flow meter 6 should read about 3-6 LPM. c. LED 9 and 10a should light up at faster rate compared with setting at 1 LPM rate. Page 3. 10. Turn power and C02 off and disconnect unit under test. 11. Affix the following labels on unit per required labeling for 2602000: 00302 00303 00304 00307 01307 M12311 M70302 Page 4. : MECHANICAL MODIFICATION 1. Remove the top and bottom cover from unit. » Cut three (3) yellow ground wires from the ground terminal with the exception of the yellow wire from the AC socket to the ground terminal. 3. Connect two (2) yellow ground wires to the place as shown below. 4. Clean the screw holes on top cover so that the proper ground could be achieved between the bottom cover and top cover. qe US AC A Te USV AC XIV, SCHEMATIC 26020 KA /KB “GENERATOR OK" Ye oa & ag us By * A a gs MODEL 26020%A, XB BIPOLAR COAGULATOR, KARL STORZ ENDOSCOPY-AMERICA, INC. | ‘TB-22-90 March 19, 1990 FOO OOOO IOC CE TRIER RRA AAAAARAREREEERERREREERERER TECuUNICAL %CNFORMATION BULLETIN FEBRERO HOOT OOO ISI ECO IIIT CTO ITER IEEE IN RITE AER 26020XA, XB Bipolar Coagulator Generator The 26020XA or XB is a low power, spark gap, radio frequency bipolar electrosurgical coagulator generator. It operates at a roughly sinusoidal frequency of approximately 500 kiiz. Its output power is approximately 15 Watts into a 125 ohm load. The output power is sensitive to test load, as the device is r.£.-transformer coupled. The following graph is typical of production units. 15 — ee 18] J ES Se 2a 28 97 © 1815 20 25 38 35 48 15 50 6878S 26028KA, XB GENERATOR POUER SELECTION SETTING EMS

You might also like