The document contains configuration information for tags associated with three motors. Each motor has tags for mode, start, stop, run/fault status, and reset which are all connected to the HMI via connection 1 and mapped to registers in the PLC but without an assigned PLC tag. Additional details such as data type and addressing are provided for each tag.
The document contains configuration information for tags associated with three motors. Each motor has tags for mode, start, stop, run/fault status, and reset which are all connected to the HMI via connection 1 and mapped to registers in the PLC but without an assigned PLC tag. Additional details such as data type and addressing are provided for each tag.
The document contains configuration information for tags associated with three motors. Each motor has tags for mode, start, stop, run/fault status, and reset which are all connected to the HMI via connection 1 and mapped to registers in the PLC but without an assigned PLC tag. Additional details such as data type and addressing are provided for each tag.
MOTOR_1_MODE Default tag table HMI_Connection_1 <No Value>
MOTOR_1_START Default tag table HMI_Connection_1 <No Value> MOTOR_1_STOP Default tag table HMI_Connection_1 <No Value> MOTOR_1_RUNFEEDBADefault tag table HMI_Connection_1 <No Value> MOTOR_1_RESET Default tag table HMI_Connection_1 <No Value> MOTOR_1_FAULT Default tag table HMI_Connection_1 <No Value> MOTOR_2_MODE Default tag table HMI_Connection_1 <No Value> MOTOR_2_START Default tag table HMI_Connection_1 <No Value> MOTOR_2_STOP Default tag table HMI_Connection_1 <No Value> MOTOR_2_RUNFEEDBADefault tag table HMI_Connection_1 <No Value> MOTOR_2_RESET Default tag table HMI_Connection_1 <No Value> MOTOR_2_FAULT Default tag table HMI_Connection_1 <No Value> MOTOR_3_MODE Default tag table HMI_Connection_1 <No Value> MOTOR_3_START Default tag table HMI_Connection_1 <No Value> MOTOR_3_STOP Default tag table HMI_Connection_1 <No Value> MOTOR_3_RUNFEEDBADefault tag table HMI_Connection_1 <No Value> MOTOR_3_RESET Default tag table HMI_Connection_1 <No Value> MOTOR_3_FAULT Default tag table HMI_Connection_1 <No Value> DataType HMI DataT Length Coding Access Me Int Int 2 Binary Absolute a Bool Bool 1 Binary Absolute a Bool Bool 1 Binary Absolute a Bool Bool 1 Binary Absolute a Bool Bool 1 Binary Absolute a Bool Bool 1 Binary Absolute a Int Int 2 Binary Absolute a Bool Bool 1 Binary Absolute a Bool Bool 1 Binary Absolute a Bool Bool 1 Binary Absolute a Bool Bool 1 Binary Absolute a Bool Bool 1 Binary Absolute a Int Int 2 Binary Absolute a Bool Bool 1 Binary Absolute a Bool Bool 1 Binary Absolute a Bool Bool 1 Binary Absolute a Bool Bool 1 Binary Absolute a Bool Bool 1 Binary Absolute a Address Start valueQuality Co Persistenc Substitute Tag value Update MoComment [ %DB1.DBW0 <No Value False False <No Value <No Value Client/Serv<No Value %DB1.DBX2.0 <No Value False False <No Value <No Value Client/Serv<No Value %DB1.DBX2.1 <No Value False False <No Value <No Value Client/Serv<No Value %DB1.DBX2.4 <No Value False False <No Value <No Value Client/Serv<No Value %DB1.DBX2.5 <No Value False False <No Value <No Value Client/Serv<No Value %DB1.DBX4.1 <No Value False False <No Value <No Value Client/Serv<No Value %DB2.DBW0 <No Value False False <No Value <No Value Client/Serv<No Value %DB2.DBX2.0 <No Value False False <No Value <No Value Client/Serv<No Value %DB2.DBX2.2 <No Value False False <No Value <No Value Client/Serv<No Value %DB2.DBX2.4 <No Value False False <No Value <No Value Client/Serv<No Value %DB2.DBX2.5 <No Value False False <No Value <No Value Client/Serv<No Value %DB2.DBX4.2 <No Value False False <No Value <No Value Client/Serv<No Value %DB3.DBW0 <No Value False False <No Value <No Value Client/Serv<No Value %DB3.DBX2.0 <No Value False False <No Value <No Value Client/Serv<No Value %DB3.DBX2.3 <No Value False False <No Value <No Value Client/Serv<No Value %DB3.DBX2.4 <No Value False False <No Value <No Value Client/Serv<No Value %DB3.DBX2.5 <No Value False False <No Value <No Value Client/Serv<No Value %DB3.DBX4.3 <No Value False False <No Value <No Value Client/Serv<No Value Limit UppeLimit UppeLimit LoweLimit LoweLinear scal End value Start valueEnd value Start valu Synchronization None <No Value None <No Value False 10 0 100 0 False None <No Value None <No Value False 10 0 100 0 False None <No Value None <No Value False 10 0 100 0 False None <No Value None <No Value False 10 0 100 0 False None <No Value None <No Value False 10 0 100 0 False None <No Value None <No Value False 10 0 100 0 False None <No Value None <No Value False 10 0 100 0 False None <No Value None <No Value False 10 0 100 0 False None <No Value None <No Value False 10 0 100 0 False None <No Value None <No Value False 10 0 100 0 False None <No Value None <No Value False 10 0 100 0 False None <No Value None <No Value False 10 0 100 0 False None <No Value None <No Value False 10 0 100 0 False None <No Value None <No Value False 10 0 100 0 False None <No Value None <No Value False 10 0 100 0 False None <No Value None <No Value False 10 0 100 0 False None <No Value None <No Value False 10 0 100 0 False None <No Value None <No Value False 10 0 100 0 False Synchronization HMI Tag n Substitute Value Usage