You are on page 1of 3

Name Path Data Type Logical Addre

-A1 Tag table_sorting station Bool %I0.0


-K0 Tag table_sorting station Bool %I0.1
-S0 Tag table_sorting station Bool %I0.2
-S1 Tag table_sorting station Bool %I0.3
-S2 Tag table_sorting station Bool %I0.4
-B1 Tag table_sorting station Bool %I0.5
-B2 Tag table_sorting station Bool %I0.6
-B3 Tag table_sorting station Bool %I0.7
-B4 Tag table_sorting station Bool %I1.0
-B5 Tag table_sorting station Bool %I1.1
-B6 Tag table_sorting station Bool %I1.2
-B7 Tag table_sorting station Bool %I1.3
-S3 Tag table_sorting station Bool %I1.4
-S4 Tag table_sorting station Bool %I1.5
-S5 Tag table_sorting station Bool %I1.6
-S6 Tag table_sorting station Bool %I1.7
-Q1 Tag table_sorting station Bool %Q0.0
-Q2 Tag table_sorting station Bool %Q0.1
-Q3 Tag table_sorting station Bool %Q0.2
-M2 Tag table_sorting station Bool %Q0.3
-M3 Tag table_sorting station Bool %Q0.4
-P1 Tag table_sorting station Bool %Q0.5
-P2 Tag table_sorting station Bool %Q0.6
-P3 Tag table_sorting station Bool %Q0.7
-P4 Tag table_sorting station Bool %Q1.0
-P5 Tag table_sorting station Bool %Q1.1
-P6 Tag table_sorting station Bool %Q1.2
-P7 Tag table_sorting station Bool %Q1.3
Comment Hmi Visible
return signal emergency stop ok (nc) True
main switch „ON“ (no) True
mode selector manual(0) / automatic(1) True
pushbutton automatic start (no) True
pushbutton automatic stop (nc) True
sensor cylinder -M4 retracted (no) True
sensor cylinder -M4 extended (nc) True
sensor motor -M1 actice (pulse signal for positioning) (no) True
sensor part at slide (no) True
sensor metal part (no) True
sensor part in front of cylinder -M4 (no) True
sensor part at end of conveyor (no) True
pushbutton manual mode conveyor –M1 forwards (no) True
pushbutton manual mode conveyor –M1 backwards (no) True
pushbutton manual mode cylinder -M4 retract (no) True
pushbutton manual mode cylinder -M4 extend (no) True
conveyor motor -M1 forwards fixed speed True
conveyor motor -M1 backwards fixed speed True
conveyor motor -M1 variable speed True
cylinder -M4 retract True
cylinder -M4 extend True
display „main switch on“ True
display „manual mode“ True
display „automatic mode“ True
display „emergency stop activated“ True
display „automatic mode started“ True
display cylinder -M4 „retracted“ True
display cylinder -M4 „extended“ True
Hmi Accessible
True
True
True
True
True
True
True
True
True
True
True
True
True
True
True
True
True
True
True
True
True
True
True
True
True
True
True
True

You might also like