Professional Documents
Culture Documents
Time 1day
Schedule
1. Function Diagram & Circuit
- circuit & parts.
2. How to check defects ?
- Error mode
- Connection Loose
3. Algorithm
4. Electric parts
5. Quality information
6. Wrap Up (Q & A)
AC-DC
AC IN CONVERTER Rrelay Motor
X 3
Power Linear 7812
Transformer
S/W 7805
Interface
LED
Part
Key input Triac
Buzzer
LED Driver
Buzzer Out
Voltage DC LINK
Voltage
Clear Micom
reset
Micom
Peripheral Clock Load Driving
resonator
AC-DC
AC IN IPM Motor
Converter
Power
16.5V
S/W 12V 7805
SMPS
Interface 12Vac
LED
Part Signal out
Key input Sensing Over Current(Fo)
Buzzer
LED Driver
Buzzer Out
Transformer Relay
- power Triac
- Heater - control Pump
Bridge Diode
- make DC Voltage
SMPS
Transformer
IPM
Triac
- control Inlet valve
Coil
- filter
Reactor
Universal
Linear Transformer
- Using regulator IC
D6
1 1
SMPS(sample)
5
D2 V3
DD Model
+ ZD1
3 2 R6 CE1 R1
CE6
6
SMPS Circuit
-
C1
D1
D3
V1
- No need regulator IC
4 7
AC 2
IC241 V2
2
*TOP246Y D4
R5
3 8 CE2 R2
Switching IC
L
1
C
- TOP SW
S
X
F
R3
R4 CE3
5
4
3
ZD2 4 9 - maker : PI
CE4
C2
ZD1 D5
VDC
Rg Cg
1 16
Triac Circuit in Universal tool
TR ARRAY
- Control the inlet valve
Rs
GATE T1
- Control the Pump control
8 TRIAC - Control the Motor circuit
T2
MICOM
Cs
VAC
Load
5V
VDC
Rg Cg
R
1 4
Triac Circuit in DD tool
1 16 2 3
- Control the inlet valve
TR ARRAY
PHOTO Rs
COUPLER
GATE T1
- Control the Pump control
TRIAC T2
Cs
8
MICOM VAC
Load
Vuee
Vwfb
Vwfs
Vufs
Vvfb
Vvfs
VP1
VP1
Vp1
Vnc
Wn
Wp
26
Un
Up
Vn
Vp
N
21
17
14
15
16
20
10
11
12
*47uF/35V 9
*47uF/35V 5
*47uF/35V 1
4
C308 C309 C315 C310 C311 C316 C312 C313 C314
CE301
CE302
CE303
R503 5V 104 104 102 104 104 102 104 104 102
IC703 *2K 1/4W C503C303 ZD301
IC_KIA393F 102 104 *24V 1W
R302
4.7K
1
5V
VEE
- +
+ - 16.5V C305 C306 C307
VCC
16.5V
A相
1 2 3
B相
C相
4 5 6
Heater control for all model Motor driving for Universal Tool
전류방향
MS
TP
X3
5
12V 4
①
⑤
⑩
3
X100 X2 X1
4
1 2
NC
1 3
5
X3
AC 4 4
BD1
2
4 4 ∼ 2
Micom
-
⑧
NO
MR 3 3
C1
⑨ 2 1 1 2 AC
SD131
Tab Ralay
1
2 X2 X1
1 + ∼ 3
R/L
SD132
*1N4148 *GSIB1560
*1N4148
부하 12V
Heater
Micom
12 Dry Heating dHE • Temperature is over the 98℃ after 4min in dry course DD Combo
Error • Temperature rising is under 10℃ than starting temperature
• Fan motor is restricted.
13 EEPROM EE • Error for EEPROM in PCB. Only when start button is first pressed in the QC test mode QC Test Mode
Error
14 Over voltage dCE • Only when DC Link voltage level is over 430V in the QC test mode DD model
QC Test Mode
.Transformer fault
- Fuse in the Transformer Open
.controller fault
.press power off
still constantly
Water supply valve fault
overflow
.press power on
directly water supply Controller fault
.Cavitation
Switch
Perception
Faulty
All S/W perception • The switch on PCB is pressed by the Panel Button
faulty
.during the washing . Connector in the PCB for Motor output is take away
process the rotation or disconnected in motor.
of speed is irregularity . IPM Fault
.short in motor
Condition : The thermistor is open (lower than (-20℃) or short (higher than 96℃)
Good
Connection Loose
- connector unplugged Connection Loose
- wire cut
Connection Loose
Connection Loose
- Terminal loose ! Connection Loose
- Connector broken
Panel button
problem
CHILD LOCK
Water
Level Motor Motor Motor
rotates rotates rotates
for 60sec. for 60sec. for 60sec.
23.0KHz
24.8KHz
Water
Draining
supply
Water
• Tips
Level Motor rotates
-In the case of the Tzar tool(WD-??13??,??16??,*S,*N,*T) for 180sec.
stay-cooling is done only 1time.
22.8KHz
24.8KHz
One time
Water Draining
supply
• First sensing suds program is done during intermittent spinning and when difference of speeds between speed-up and
speed-down is more than 60 (r.p.m / sec), the micom recognizes it as suds problem.
• Second sensing suds program : The micom recognizes it as suds problem when the spinning speed does not reach 450r.p.m
in 18 sec or when the water pressure is lower than 23.0kHz.
• Third sensing suds program : When present r.p.m becomes lower 200r.p.m than the Max r.p.m or is lower than 350r.p.m,
the micom recognizes it as suds problem.
• When suds is detected, spinning is stopped and the Suds remove program is started. And then the Water supplying and
draining are proceeded until suds is not detected.
Washing Process
Spinning Process
If frequency is lower
than 23.0KHz, the
Lower than machine decides it has
23.0KHz suds problems.
(But, in heating course Suds sensed
the frequency is 22.9KHz)
Washing Finish
Washing Finish
※ < Remarks>
• During wool, blanket and stay cooling course,
the sensing suds does not work
• Heater is off while removing suds
• Motor is off during draining
▣ Only this kind of function can be done in Micom type washing machine. i.e, the washing machine
tries to solve the unbalance problem by itself before it asks customers helps.
Sensing
period
50 rpm
2.Untangling
O.K
• The delay time is the time from present time to the time when all the cycle is finished.
• The machine starts its first step 25 minute earlier considering water supplying time and heating time.
Tzar_Bluebird WD-??15?N/S CREASE CARE KEY + PRE WASH KEY + POWER KEY
BLUEBIRD WD-??15?FB CREASE CARE KEY + PRE WASH KEY + POWER KEY
▣ To use QC Test mode, push the Power’ button on and then press the ‘Spin’ button and
a ‘Rinse’ button simultaneously . And then press the ‘Start/pause’ button step by step.
Display Status
Times of
Press Checking Point WD-1020W WD-1050F WD-1253F meaning
WD-1040W WD-1055F WD-1255F
▣ Even if you press the button to check inlet valve, inlet valve does not operate until the drum comes to
a complete stop from spinning.
▣ In no water state, the frequency is 63~67.
▣ HOW TO CHECK THE WATER LEVEL FREQUENCY ▣ HOW TO CHECK THE WATER Temperature
▣ HOW TO CHECK THE WATER LEVEL FREQUENCY ▣ HOW TO CHECK THE WATER Temperature
▣ HOW TO CHECK THE WATER LEVEL FREQUENCY ▣ HOW TO KNOW TO TEMP. OF EACH THERMISTER AT OPERATING CONDITION
DD Model
(3)
RD
(1)
(1) (3) WH
Universal Model
(1) (3)
(3) RD
(1)
WH
Pressure Switch
: When a cup is put into water upside down,
the air in the cup is compressed and its pressure
becomes higher than the atmosphere pressure. Tube
The compressed air in the tube connected to Diaphragm and
operates pressure switch to convert the changed air pressure
to electronic frequency.
Trip point
Reset point
Air chamber
2) Structure
⑥
1.Cover : It receives the air pressure from a tub
2.Diaphragm : It goes up by the Air pressure ⑤
3.Core : Ferrite core moves up and down with Diaphragm.
4.Coil : Weak current flows through coil and Inductance
is varied by the core position. ④
5.Capacitor : It oscillates the alternating current with
input direct current . ③
6.Adjust bolt : It adjusts stable frequency to get proper water level.
②
kHz mH
: frequency
H1 : Coil L value
H2
f = frequency
* Basic Equation L = Coil Inductance
H3 C = Capacitance
1
f =
2π LC 0 low mid high mmH O2
P2
P2
H2 H1
H2 H1
P1 P1
P3 P3
[Fig1] Water supply stop [Fig2] Power On [Fig3]Water supply [Fig1]Power Off [Fig2] Water supply stop
(3)
(4)
(1) (2) 2. The thermistor (temperature sensor) is used to monitor
water temperature in the tub.
Yes
1. Conditioner is supplied Ans) Please keep the level in the detergent
before the last rinse? box lower than the Max line please.
No
3. What type of conditioner are used? Powder Powder type should not be used in the
- Powder / Liquid detergent box, but be manually used.
only liquid type is possible
Liquid
Yes If it is too sticky, please mix the conditioner
Is the conditioner sticky ?
with water a little.
No
•Thumping sound • This is usually sound (In case of heavy wash load)
• If sound continue, washer is probably out of balance.
Stop and redistribute wash load.
•Suds over •To much detergent or unsuitable detergent may cause
excessive foaming which may result in water leaks.
•Water in the washer does not •Clean and straighten the drain hose.
drain or drains slowly • Clean the drain filter.
•Water does not enter washer • Check another tap in the house.
or it enters slowly • Fully open tap.
• Straighten hose.
• Check the filter of the inlet hose.
•Smell •When installing the drain hose to a sink, make sure that
the drain hose is fixed before the "U-bend" - This will
prevent smells coming up from the drain.
• I want to program an additional •The length of the wash cycle is controlled by the program.
washing time. It can not be manually adjusted.
•Water Level low •The roller jets and water circulation will compensate for
the lower water level. The water level will not be above
the bottom of the door glass