Professional Documents
Culture Documents
CONTENTS 2
▶ SPECIFICATION
▼ SENSORS
▶ INSTALL LAYOUT
- APT SENSOR
▶ COOLING CIRCUIT - FIN THERMO SENSOR
▼ PARTS IN ENGINE COMPARTMENT - INCAR SENSOR
- CONDENSER - PHOTO SENSOR
- COMPRESSOR - AMBIENT SENSOR
▼ PARTS IN CABINE - AQS
- HEATER UNIT - HUMIDITY SENSOR
- EVAPORATOR UNIT ▶ TEMPERATURE UNIT CHANGE
* AIR FILTER ▶ CONTROL LOGIC
* BLOWER MOTOR
▼ SELF DIAGNOSIS
* POWER TR
- DTC LIST & FAILSAFE
* BLOWER RELAY
▼ ACTUATORS ▶ PTC HEATER
- INTAKE DOOR ACTUATOR
- TEMP. DOOR ACTUATOR
- MODE DOOR ACTUATOR
PURPOSE OF FATC 3
EF SONATA
HVAC UNIT
NF HVAC UNIT
Blower unit
HVAC unit
SYSTEM COMPARISON 6
Type 6PK ← ←
Pulley
Pulley Diagram 120mm ← 125mm
Type R-134a ← ←
Refrigerant
Quantity(g) 550 ← ←
INSTALL LAYOUT 8
3
2
1
NO Parts Name
1 Blower Assembly
2 HAVC Assembly
3 Air conditioner Controller(FATC)
4 Condenser and Cooling Fan Assembly
5 4
5 Expansion valve(Block type)
6 APT Sensor
7 Compressor Assembly
8 Low Pressure Horse
9 High pressure Horse
8 9
7
COOLING CIRCUIT 9
COMPONENTS
CONDENSER 11
Piston
Outlet chamber
(Pd)
Swash plate
Inlet chamber
(Ps)
Shaft
Piston
Inlet chamber
Swash plate (Ps)
Outlet chamber
(Pd)
Shaft
Control
chamber (Pc)
Operation
• Control chamber pressure > Inlet chamber pressure: Swash plate angle decrease
• Control chamber pressure = Inlet chamber pressure: Swash plate angle increase
COMPRESSOR (Variable Swash Plate) 15
Operation
Outlet chamber
Control chamber
pressure increase
Operation
Outlet chamber
Control chamber
pressure decrease
Operation Diagram
• Standardize the inlet pressure
• Standardize the Venting temperature
• Clutch Cycling Prevention
• Iimprovement in Fuel Consumption
• Engine Surge Prevention
Control chamber * Swash plate tilting angle decreasing. * Swash plate tilting angle increasing. Control chamber
pressure increasing * Outlet flux decreasing. * Outlet flux increasing. pressure decreasing
Inlet pressure < Control valve standard value Inlet pressure > Control valve standard value
Vent DEF
Foot
Blower connecting
Drain hose
EVAPORATOR UNIT 19
EVAPORATOR UNIT 20
EVAPORATOR AIR FILTER 21
1. DESCRIPTION
Employing combination filter, dust and odor in the air is effectively removed.
2. LIFE TIME
Filter replacement period is 5,000~12,000km. But this can be shorten if
the road condition is bad causing more dust and black smoke in the air.
3. HOW TO REPLACE
① Remove the glove box.
② Pull the locking part of the air
filter cover
BLOWER MOTOR ASSEMBLY 22
② Without load
- speed : 3,300 rpm (min)
- current : 3.0A (max)
1. POWER TRANSISTOR
BLOWER SPEED CONTROL DEVICE 24
CONTROLLER
1 step 3.8V
2 step 4.9V
High Speed
3 step 6.1V
Blower Relay B 4 step 7.2V
5 step 8.3V
E 6 step 9.5V
7 step 10.6V
8 step B+
BLOWER SPEED CONTROL DEVICE 25
CONTROLLER
High Speed
Blower Relay B
E v Measure voltage:
Variable (up/down
blower speed switch)
A B
Terminal Function
B-1 Sensor source (5V)
B-12 Sensor ground
A-24 Sensor feedback signal
M
A-23 Intake actuator(REC)
A-22 Intake actuator(FRE)
Intake actuator
TEMPERATURE DOOR ACTUATOR 29
A B
4.7V
2.5V
M 0.3V
Temp.
actuator Cool Warm
4.7V
2±2
M
M
0.3V
COOL HOT
[POTENTIOMETER CHARACTERISTICS]
MODE DOOR ACTUATOR 32
MODE DOOR ACTUATOR 33
4.5V
A B
3.5V
2.45V
1.63V
0.4V
M
VENT B/L FLOOR MIX DEF
Mode
actuator
SENSORS
1. DESCRIPTION
Fin sensor is installed in the evaporator in order to detect the temperature
of evaporator. It prevents evaporator from freezing.
2. FIN SENSOR
① LOCATION
: inserted into the evaporator pin
FIN SENSOR 36
-20 97.75
-10 55.85
0 32.91
20 12.51
40 5.31
60
2.48
80 1.25
A B
Terminal Function
B-6 Sensor source (5V)
B-12 Sensor ground
Fin thermo
sensor
IN-CAR SENSOR 38
The in-car sensor is located on the crash pad as shown in the picture. It
contains a thermister, which measures the temperature of the air inside the
passenger compartment. It senses the passenger compartment
temperature, changes the resistance value, and enters the corresponding
voltage into the automatic temperature control module (FATC).
Humidity
sensor
In-car
sensor
IN-CAR SENSOR 39
A B
IG 2
Terminal Function
B-5 Sensor source (5V)
B-12 Sensor ground
B-17 Motor ground M
In-car sensor
PHOTO SENSOR 40
A B
Terminal Function
B-1 Sensor source (5V)
B-15 Sensor ground
AMBIENT SENSOR 42
A B
[Sensor characteristics]
Ambient sensor
AIR QUALITY SYSTEM 44
SPECIFICATION
Operating voltage 9 ~ 16V DC
Rated voltage 12V DC
Operating temperature -30 ~ 105℃
Gasoline engine gas CXHY, CO,C6H6…
Detectable gas
Diesel engine gas NOX, SO2
Reaction time less 1 sec
AIR QUALITY SYSTEM 45
FATC AQS
CONTROL
IG 12V
MODULE
Output
- Normal → 5V
GAS - Gas detected → 0V
detected
(REC)
M
Intake
Actuator
Normal
cw ccw
(FRE)
HUMIDITY SENSOR 47
1. SENSOR CHARACTERISTICS
%RH ref SPECIFICATION(Hz)
10 7060
20 6950
30 6855
40 6750
50 6645
60 6540
70 6410
80 6275
90 6100
HUMIDITY SENSOR 48
A B
Terminal Function
B-1 Sensor source (5V)
B-4 Sensor input(5~10hz)
B-12 Sensor ground
APT SENSOR 49
Evaporator
Comp.
Condenser Receiver
APT SENSOR
- Engine Idle Control
PWM Multi Speed - Cooling Fan Control
Cooling fan - Compressor Control
- High Pressure Cut-out
- Low Pressure Cut-out
ECU
(Engine Control Unit)
APT SENSOR 50
APT SENSOR 51
Connector Base
Terminal (3EA)
RTV
Flexible Circuit
Pin
Ceramic Substrate
Silver Epoxy
Ceramic Diaphragm
O - Ring
Refrigerant pressure
VOLTAGE
Signal Conditioner
ASIC
Source
Detect
Guard
Glass seal
Ceramic Diaphragm
PRESSURE
APT SENSOR 53
GUARD (GND)
DETECT
SOURCE
* The main function of APT sensor is detecting the refrigerant pressure (distance d).
APT SENSOR 54
5 Approximately 4.8V
OUTPUT (Vdc)
Approximately
Normal
0.2V Operating range
0
A. There is 0.2V(not 0V), if the refrigerant line pressure has gone to 0, for communication to
engine ECM. (0V means poor contact or open circuit)
B. There is 4.8V, even if the line pressure is over the standard value (high pressure).
(5V means short circuit)
APT SENSOR 55
A B
5V
E APT sensor
C
Terminal Function M
A B
Terminal Function
B-7 Sensor source(5V)
B-12 Sensor ground
WTS sensor
COOLING FAN 58
Shroud Fan
PWM
Motor
COOLING FAN 59
* How to operate
-1 up / 4sec delay
-1 down / 4sec delay
6. Mode control
- AUTO: Mode changes automatically according to the selected
temperature and other sensor signals.
- Manual: Mode changes when the mode switch is selected.
OPERATING CONDITONS
1. Ambient temp. < 10
2. Water temperature: below 73
3. Mode: Auto or Floor
4. Blower: Auto
Operation release
- When the occupant operates DEF switch.
- When the occupants select Max. cool(17 ).
- When the detected temperature by WTS exceeds 73 .
CONTROL LOGIC 67
DEF
Mode
MIX
Auto control
Auto high
Auto low
Blower
Volt
Press OFF
Return to original condition
DIAGNOSIS 70