Professional Documents
Culture Documents
This section describes how to create internet e-mail message via Inmarsat service provider.
NOTE
When you edit message for internet e-mail, check message format to LES service
provider you want to send e-mail.
Edit
Step 3 Press <Enter> to obtain “Edit” dialogue box.
MENU EDIT edit Telex file EDIT ASCII FILE 선
edit Ascii file 택
Delete file
reName file
Copy file
F10:Previous
Step 4 Select “edit Ascii file” by pressing the up/down arrow keys, an then press <Enter>.
Edit Ascii file
File : F:
Edit
No. File name Date Time Size
edit Telex file
1. TEST1 04-07-01 00:01 100
edit Ascii file
2. TEST2 04-07-02 10:00 52
Delete file
SSAS 내용 저장된 파 reName file
일 이름 찾을것, Copy file
보통 SSAS 또는 ↑↓ contd. ( Total : 2 Residual: 975KB )
cOpy to another diskette
SSAS.TXT 로 이름 정
Initialize Diskette
하여 SAVE
disKcopy F10:Previous
F10:Previous
- E9 -
Step 5 Type the filename of the message, and then press<Enter>. Edit Ascii file
Delete file
reName file
Copy file
↑↓ contd. ( Total : 2 Residual: 975KB )
cOpy to another diskette
Initialize Diskette
disKcopy F10:Previous
F10:Previous
ATTENTION
0,1,2,3,4,5,6,7,8,9,A,B,C,D,E,F,G,H,I,J,K,L,M,N,O,P,Q,R,S,T,U,V,W,X,Y,Z.
SECURITY SECURITY
MES NO, 123456789
LAT,N12 34.56LON,E123 45.56,UTC,07.01.2004 12:34,SOG, 10.0KT,COG,20DEG
ATTENTION
When you edit message for internet e-mail, check message format to LES provider
you want to send e-mail.
If the created message could not be sent to the destinations by e-mail,
the message could be created by the incorrect format.
- E10 -
메세지 작성법
나머지 TEST라는 내용
또는 기타 입력내용은
전부 삭제바람
- E11 -
< SERVICE PROVIDER : STRATOS>
Special Access Code : 63 or EMAIL LES ID: AOR-W:002, AOR-E:102, 1POR:202, IOR:302
- E12 -
SSAS TEST 방법
6.3 Setting up sending the internet e-mail via Inmarsat service provider
This section describes how to set up for sending the internet e-mail via Inmarsat service provider.
NOTE
When you edit message for internet e-mail, check message format to LES service
provider you want to send e-mail.
Set up
Step 1 Press <ESC> until the screen clear.
Step 2 Press <ALT> + <U> to obtain “Set up” dialogue box. Date & time
log-Out initiation
log-In initiation
Performance test initiation
Scheduled transmission
1. ALT + U 침
Land id registration for polling
2. 오른쪽과 같이 SET UP 창 나타남
Closed network id selection
3. CTRL + F10 동시에 눌림 Peripheral Function
4. 화면 아래창에 F1: SSAS TEST 나타남
5. 여기서 F1 눌리면 SSAS 바로 테스트 발사됨 F10:Previous
참고, F1 눌리고 발사전에 #1 안에 들어가서 내용
확인할것
Step 3 Select “Scheduled transmission” option by pressing the up/down arrow keys , and then press <Enter>.
“Scheduled transmission” dialogue box will be appeared.
Set up
Scheduled transmission
Date & time
log-Out initiation
log-InScheduled
initiation transmission #1
Scheduled
Performance testtransmission
initiation #2
Scheduled
Scheduled transmission #3
transmission
LandScheduled transmission
id registration for polling#4
ClosedScheduled
network idtransmission
selection #5
Peripheral Function
F10:Previous
F10:Previous
Step 4 Press <Ctrl>+function key10 <F10>, and then “F1:SSAS TEST” will be appeared in the bottom of
“Scheduled transmission” dialogue box. Set up
F10:PreviousF10:Previous
F1: SSAS TEST
- E24 -
Step 17 Setup is completed, and then press function key10 <F10> to finish the setup.
- E28 -
7. Transmitting security alert
Cover
NOTE
1. Your creating message and the following message are transmitted to pre-designed destinations.
SECURITY SECURITY
MES NO, 123456789
LAT,N12 34.56LON,E123 45.56,UTC,07.01.2004 12:34,SOG, 10.0KT,COG,20DEG
ATTENTION
To cancel security alert transmission if you accidentally push the button, push the button again
within 30 seconds.
When security alert transmission has canceled, the following widow will be displayed on DTE
screen.
Step 3 MES transmits SSAS message in order of a young file number of scheduled transmission configuration
file.
Step 4 To stop transmission, push button again to pop up the pushed button.
ATTENTION
If you turn on the MES with any security button has been pushed in, The MES resumes the security
alert transmission.
-E29-
8. Security alert transmission test
This section describes how to initiate the security alert transmission test.
The test transmission actives with setting up for real security alert transmission.
The security message transmitted under test mode is added the following message.
ATTENTION
Setup the security alert setup menu beforehand transmit security alert test messages.
Step 2 Press <ALT> + <U> to obtain “Set up” dialogue box. Date & time
log-Out initiation
log-In initiation
Performance test initiation
Scheduled transmission
Land id registration for polling
Closed network id selection
Peripheral Function
F10:Previous
Step 3 Select “Scheduled transmission” option by pressing the up/down arrow keys , and then press <Enter>.
“Scheduled transmission” dialogue box will be appeared.
Set up
Scheduled transmission
Date & time
log-Out initiation
log-InScheduled
initiation transmission #1
Scheduled
Performance testtransmission
initiation #2
Scheduled
Scheduled transmission #3
transmission
LandScheduled transmission
id registration for polling#4
ClosedScheduled
network id transmission
selection #5
Peripheral Function
F10:Previous
F10:Previous
-E30-
Step 4 Press <Ctrl>+function key10 <F10>, and then “F1:SSAS TEST” will be appeared in the bottom of
“Scheduled transmission” dialogue box. Set up
F10:Previous
F1: SSAS TEST F10:Previous
Step 5 Press function key 1<F1> to start the security alert transmission test.
NOTE
1. The MES starts transmission with setup of “ Scheduled transmission #1” immediately after
pressing function key 1 <F1>. If the another setup has been configured,
The MES starts transmission with setup of “Scheduled transmission #2” at 12 minutes after
pressing function key 1 <F1>, starts transmission with setup of “Scheduled transmission #3” at
24 minutes after pressing function key 1 <F1>, starts transmission with setup of “Scheduled
transmission #4” at 36 minutes after pressing function key 1 <F1>, and starts transmission
with setup of “Scheduled transmission #5” at 48 minutes after pressing function key 1 <F1>.
2. This test mode remains for 1 hour.
3. Your creating message and the following message are transmitted to pre-designed destinations.
TEST TEST
MES NO, 123456789
LAT,N12 34.56LON,E123 45.56,UTC,07.01.2004 12:34,SOG, 10.0KT,COG,20DEG
Step 6 The test mode is finished after one hour from pressing function key 1<F1>.
NOTE
The security alert transmission test mode is cancelable if the power switch on the IME
to OFF and ON within one hour from pressing function key 1<F1>.
-E31-