You are on page 1of 2

Armouring for copper cables http://www.cavicel.

com/en/Armouring-copper

FOLLOW US ITA ENG

Search... »

HOMEPAGE

COMPANY

PRODUCTS

APPLICATIONS

DOWNLOAD

TECHNICAL DATA

CONTACTS

VIDEO

LINK

QR CODE: CERTIFIED Home » »


QUALITY
ARMOURING FOR COPPER CABLES

Metallic armour are used when cables have to be installed direct buried, or if mechanical protection is required.
Following points must be considered:
Starting from June 1st, Cavicel
has introduced a new system to
certify the Quality of its Required tensile load
Read more »
Expected pressure on cable during service
Protection against rodent
News list »
Protection against accidental damage
Minimum required bending radius

4,250

4,150 SWA: single layer of galvanized steel wires, with diameters according to
4,050
relevant standards, coverage min. 90%. This armour assures a very good
3,950
mechanical protection and tensile strength. An additional counterspiral tape
increases solidity, if required.
18 Jan 28 Jan 09 Feb

GSWB: galvanized steel wire braid, diameter of wire: 0.20 - 0.25 - 0.30 - 0.40
Date 02/12/2016 mm, with coverage of >80%. It assures a good mechanical resistance,
allowing a lower bending radius compared to other armour. It is preferable
Copper €/ton 3,980.93 when there is movement or vibration.
rate €/$ 1.1275 For special application is possible to use stainless steel, tinned copper or
special alloy wires
Show quotations »
GSTA: galvanized steel tape armour, composed by two tapes with overlapped
edge; thickness of each tape: 0.20 – 0.30 – 0.40 mm, according to cable
diameter. It grants a coverage > 100%. Very good crush resistance, but fair
tensile strength.
Brass tape of minimum thickness 0.075 mm can be used for special
applications.
GSFA: : galvanized steel flat armour. It is composed by flat wire of thickness
0.6 mm or 0.8 mm, it is similar to SWA, but with higher mechanical protection.

PRODUCT CATEGORIES

FIRE RESISTANT CABLES FIBRE OPTIC CABLES INSTRUMENTATION SPECIAL CABLES


CABLES

1 of 2 13/02/2016 9:35
Armouring for copper cables http://www.cavicel.com/en/Armouring-copper

HOME COMPANY PRODUCTS APPLICATIONS DOWNLOAD TECHNICAL DATA CONTACTS LINK


Who we are Fire resistant cables Application Catalogues Standards Customer care
Mission Fibre optic cables areas Certifications Materials How to reach us
Quality Instrumentation cables Reference list Documents Designation systems Contact form
Cavicel at a glance Special cables Screening Privacy & Cookie
Our markets Catalogues Protections and armouring Policy
Sustainability Product certificates Tests
Photogallery Conductor resistance
Terms of sales Conductors AWG
Characteristics for fibre
optic cables
Drums
Packaging

CAVICEL S.p.a Via Caduti del Lavoro, 18a - 20096 Pioltello (MI) Italy
Tel. +39 02 921 605 21 - Fax +39 02 921 607 53
P.IVA IT02752510152

Cavicel SpA (DMCC Branch) Fortune Executive Tower - Office 406 - Plot No. T1
Jumeirah Lakes Towers - Dubai - UAE - PO Box 7042
Tel. +971 4 4581199 - Fax +971 4 4581144 Sito realizzato da Èspero

2 of 2 13/02/2016 9:35

You might also like