You are on page 1of 1

TENTHS 0 INCHES 1 2 3 4 5 6 7 8 9 10 EIGHTHS 0 MM 10 20 30 40 50 60 70 80 90 100

PLOT DATE : 13/05/2019 14:36 BY NickA


NOTES - (U.O.N.)
1. ALL CIVIL WORK TO BE CARRIED OUT IN ACCORDANCE WITH :-
0045-00-CI-DSC-0001 - CIVIL/STRUCTURAL DESIGN CRITERIA
0045-00-CI-SPC-0001 - EARTHWORKS SPECIFICATION.
0045-00-CI-SPC-0002 - CONCRETE SPECIFICATION.

2. CONCRETE
- STRUCTURAL CONCRETE - CLASS 30MPa/19mm.
5. 23987 (REF)
4 23987
3 23987
2 23987
1 18586
- SLABS/GROUND BEAMS
- BLINDING
- CLASS 30MPa/19mm.
- CLASS 15MPa/13mm.
NTS (REF) - MASS CONCRETE - CLASS 15MPa/19mm.
3886
F 3. 50mm BLINDING UNDER ALL FOUNDATIONS & GROUND BEAMS.

4. ALL EXPOSED CONCRETE CORNERS TO HAVE 20mmx20mm CHAMFER.


P1 P1 B5
P1 P1

4000
5. ALL FOUNDATION EXCAVATIONS TO BE INSPECTED BY THE ENGINEER

3519

3401
B1

3283

3167
B1 B1 B1 PRIOR TO CASTING OF BLINDING AND TO BE KEPT DRY AT ALL TIMES.

1710 1710
BOTTOM OF EXCAVATION TO BE INSPECTED AND LEVEL TO BE APPROVED
CL CONVEYOR
CVC-004
CL CONVEYOR
CVC-004
CL TAIL
PULLEY BY ENGINEERS REPRESENTATIVE PRIOR TO PROCEEDING WITH SOIL
IMPROVEMENT SUCH AS IN-SITU RE-COMPACTION OR SOIL
0045-CVC-255209

3573
3691
3809
3926
REPLACEMENT. ALL FOUNDATION EXCAVATION IN ROCK TO BE CUT
MATCH LINE

NEATLY TO OUTLINE OF FOUNDATIONS AND CONCRETE TO BE CAST


AGAINST ROCK.
P1 P1 P1
P1 6. FOUNDATIONS HAVE BEEN DESIGNED FOR AN ALLOWABLE GROUND
B1 B1 B1
B1 S.O.P 1
BEARING PRESSURE OF 250 kPa AT UNDERSIDE OF FOUNDATION LEVEL,
900 2880 3393 3380 4426 IF THIS PRESSURE IS NOT REACHED AT THE DEPTH SHOWN THE DESIGN
ENGINEER MUST BE INFORMED.

7. ALL LEVELS AND DIMENSIONS TO BE VERIFIED ON SITE BY THE


CONTRACTOR BEFORE ANY WORK COMMENCES. ANY DISCREPANCIES
CONVEYOR 2552-CVC-004 - PLAN ARE TO BE REPORTED TO THE ENGINEER.
1:200
8. ALL LEVELS SHOWN ARE TO TOP OF CONCRETE (T.O.C.).
E
9. ALL CAST IN ITEMS ARE TO BE SUPPLIED BY THE CONTRACTOR
(UNLESS OTHERWISE NOTED) (U.O.N.)

10. CONCRETE SURFACE FINISHES :


a. STRUCTURAL : VERTICAL - OFF SHUTTER (DEGREE OF ACCURACY II)
: HORIZONTAL - WOOD FLOAT.
b. SURFACE BEDS : WOOD FLOAT (U.O.N.)

11. BACKFILL UNDER SURFACE BEDS TO BE COMPACTED TO 95% MOD.


AASHTO IN 150 LAYERS AT 2% OMC.
TERRACE
4 3 2 LVL. VARIES 1 12. ALL H.D. BOLTS TO HAVE A TOLERANCE OF ±2mm IN ANY DIRECTION.
1346.710 1346.550 1346.389 13. FOR STANDARD H.D. BOLT DETAILS REFER TO DRG No. 0045-CI-000002
1346.219 TERRACE 1346.226
T.O.C. 4 T.O.C. 3 LVL. VARIES
200
Min

TERRACE T.O.C. 2 T.O.C - S/B T.O.C. 1 14. FOR STANDARD CIVIL CONSTRUCTION DETAILS REFER TO DRG.

200
Min
No. 0045-CI-000001.

15. ALL BUILDING CONSTRUCTION TO BE IN ACCORDANCE WITH SANS


1215:1984 AND SANS 10145:2000 AS AMENDED.

D COORDINATES TABLE
CONVEYOR 2552-CVC-004 - ELEVATION
1:200
GAUSS-KATANGA COORDINATES SYSTEM
PNT X(E) Y(S) ELEVATION
SOP 1 117275806.158 194364354.491 1346.225
- - - -
- - - -

M20 H.D. BOLTS


TYPE "B" MARK "C"

100 100
2000 12000

120
2500
600
1000 1000 724 900 2880 3393 3380 723 1250 1250
300 300 150 750 350 350 750 150
M24 H.D. BOLTS W

50
DETAIL DETAIL
TYPE "A" D300 0045-CI-225210 Y
0045-CI-225210 Z
0045-CI-225210
DETAIL - W
300
1000

C
150 150

150
600

M20 H.D. BOLTS


2000

500

DETAIL Y TYPE "B" MARK "C"


300

100 100
1000

P1

750
1247
495

CL CONVEYOR
1710

& TAKE-UP

225 150150
150 150
DETAIL

353 347
2500
X SHEAR POCKET
715

0045-CI-225210
150 x 150 x 150 DEEP

120
3420

1253
DETAIL W
BASE 'B1' PLINTH 'P1'
715

DETAIL X

750
1:20

50
1:50
1710

8 No. OFF 8 No. OFF DETAIL Y DETAIL Y DETAIL Z


495

150
DETAIL - X
500

1346.226
M20 H.D. BOLTS BASE 'B5'
100 100
T.O.C. 1 1:50
200

TYPE "B" MARK "C"


Min

150
B TERRACE 1 No. OFF
BASE 'B4'
1:50
1197

1 No. OFF

150
1346.222 12 No. M20 H.D. BOLTS
M20 H.D. BOLTS DETAIL - Y TYPE "B" MARK "C"
T.O.C.
600

TYPE "B" MARK "C"


1346.219
T.O.C - S/B
200
Min

TERRACE

700
100 100
BLINDING M20 H.D. BOLTS

150
TYPE "B" MARK "C"
700

BLINDING
SECTION 'B1'

150
1:50
BLINDING
2x SHEAR POCKET SECTION 'B5'
150 x 150 x 150 DEEP
SECTION 'B4' 1:50
1:50 DETAIL - Z

A
NOTE: TYPES A & B = 1 x set of 4 bolts.
REFERENCE DRG'S

PROFESSIONAL COORDINATES
SJP 08.11.2019 J.N. 2020.05.29 CLIENT PROJECT:
ISO A1-594x841

DRAWN
M.W J.N
METC ENGINEERING
12 AUTUMN ROAD
ENGINEER / DATE
SYSTEM KIPUSHI ZINC PROJECT
2 DRAWING UPDATED AND RE-ISSUED FOR CONSTRUCTION.
REVISIONS

RIVONIA
Vee V. 22.10.12 CHECKED R.K.R. 2020.04.21 PR.REG No/SIGN. 20130341
ORE HANDLING
..........................
SJP J.N
SANDTON GAUSS-KATANGA
1 RE ISSUED FOR CONSTRUCTION
R.K.R 20.05.29
SOUTH AFRICA
www.metcengineering.com PROJ. SECTION PROCESS SA
0 ISSUED FOR CONSTRUCTION
SJP ?
R.K.R. 20.01.26
LEADER ENGINEER
(Kipushi Corporation SA) CONV. 2552-CVC-004 LAYOUT & DETS. SHT 2
ANY CONSTRUCTION AND ERECTION BASED ON METC ENGINEERING
DRAWINGS IS SUBJECT TO STRICT ADHERENCE TO THE
ELECTRICAL PROJECT Societe
´ ´ anonyme avec conseil d'administration
A ISSUED FOR TENDER 0045-CI-255209 CONV. 2552-CVC-004 LAYOUT & DETAILS HEAD SECTION METC ENGINEERING APPROVED SPECIFICATIONS AND STANDARDS FOR
ENGINEER MANAGER SCALE DRG. No. REV. No.
CONSTRUCTION AS ISSUED AND ALSO AVAILABLE ON REQUEST AND
Metallurgical Engineering Technology THIS DRAWING

2
METC ENGINEERING SHALL BE INDEMNIFIED BY ANY PARTY UNLESS THE

REV DESCRIPTION DRAWN ENG'R


CHK'D DATE REV DESCRIPTION DRAWN ENG'R
CHK'D DATE DRAWING No. DESCRIPTION
& Construction DRAWINGS HAS BEEN ISSUED TO THEM SPECIFICALLY AND EXCLUSIVELY
FOR THE PURPOSE OF CONSTRUCTION AND THE APPROVED SAID
SPECIFICATIONS AND STANDARDS HAVE BEEN STRICTLY ADHERED TO
C&I
ENGINEER
CLIENT
APPROVAL
CONTRACT / ENQ.
C0045
THIRD ANGLE
PROJECTION
1:200 A1 0045-CI-255210
8 7 6 5 4 3 2 1

You might also like