You are on page 1of 25

OTN Systems & XTran

© Belden | belden.com
XTran Portfolio

© Belden | belden.com 2
End-to-End MPLS for Operational Telecom made easy

Access Aggregation Core


XT2215

XT2210

XT2206
XT1104
XTD2110
XTD2100

XTR2124 MPLS-TP

Ethernet IF Ethernet IF Ethernet IF Ethernet IF


Fixed Unit Legacy IF Legacy IF Legacy IF
Modularity Modularity Modularity
Redundancy Redundancy
© Belden | belden.com
Capacity XTran 3
The XTran modular concept
Stainless Steel Chassis
Passive Backplane

Fanless / extended temperature range


-20°C to +65°C
EMC hardened
IEC61850-3 / IEEE 1613 / EN
50121-4

1 or 2 Power Supplies
• 240 VAC
• 18 - 60 VDC
• 88 – 300 VDC

1 or 2 Central Switching Modules


© Belden | belden.com XTran 4
Real Multi Service over MPLS-TP

Packet Solution with


the deterministic
behavior of TDM WAN
MPLS-TP

Each Service has its


own Tunnel and
Pseudowire –
Specific assigned
bandwidth and QoS

GE / 10 GE GE / 10 GE G.703 C37.94 / OLS


FXS SHDSL E1/T1 Serial 2/4 W E&M
Connectivity L3 Routing CoDir Teleprotection

© Belden | belden.com XTran 5


Portfolio XTran

Serial Serial

CoDir CoDir

4W 4W

1 G Eth 1 G Eth

10 G Eth 1 G Eth 1 G Eth 10 G Eth


10 G Eth 10 G Eth
40 G Eth 40 G Eth
40 G Eth 40 G Eth
FXS FXS

T1/E1 T1/E1

C37.94 C37.94

STM1/4 STM1/4

© Belden | belden.com XTran 6


Basic Building Blocks

XT2210 XT2206 XT1104


10 Slot Chassis XT2209 6 Slot Chassis 4 Slot Chassis
Dual slot for Power Supplies 9 Slot Chassis (L3 high-speed) Dual slot for Power Supplies Single slot for Power Supplies
Dual slot for CSM Dual slot for Power Supplies Dual slot for CSM Single slot for CSM
Dual slot for CSM

XT2215
DCP-C DC PSU/ 18 – 60 VDC 15 Slot Chassis
Dual slot for Power Supplies
DCP-D DC PSU/ 88 – 300 VDC Dual slot for CSM

ACP-B AC PSU / 90 – 264 VAC


ACP-A DCP-A DCP-B CSM310-A/B
AC PSU DC PSU DC PSU 64 Gbps switching fabric
90 – 264 VAC 18 – 60 VDC 88 – 300 VDC MPLS-TP
L2 protocol interaction
IEEE1588TC CSM540-A
IEEE1588BC(B) 720 Gbps switching fabric / MPLS-TP / L2 protocol interaction

© Belden | belden.com XTran 7


Ethernet/IP Interface Modules

4-GC(B)-LW 4-GO-LW 1-10G-LW


4 ports 10-100-1000 Eth 4 ports GE 1 XFP Full Duplex
4 RJ 45 4 SFP 1000 base-X 10 Gbps 4-10G-LW 4 XFP Full Duplex
1 SFP 1000 base-X (combo) IEEE1588v2 IEEE1588v2 10 Gbps
IEEE1588v2 MAC Sec MAC Sec IEEE1588v2
PoE 802.3at (Except (B)) MAC Sec
MAC Sec

LAN/WAN
1-40G-LW 1 QSFP Full Duplex
6-GE(P)-L 9-L3A-L/9-L3EA-L 4-DSL-LW 40 Gbps
6 ports 10-1000 Eth 8 ports 1000 SFP 4 SHDSL ports IEEE1588v2
6 RJ 45 1 port XFP 10G PAF or Bonding MAC Sec
L2 protocols L2/L3 protocols
POE+ on P-variant Router with VRF

16-GEP-L 16 ports 10-1000 RJ45


L2 protocols
POE+

© Belden | belden.com XTran 8


Legacy Interface Modules

4-E1T1-L 16-E1T1-L 8-FXS 7-SERIAL 6-SERIAL


4 E1 or T1 ports 16 E1 or T1 8 ports FXS Up to 7 ports 2 port servers
SAToP or CESoP ports SIP Client RS232, RS422, RS485, 2 port server or CES
16 bundles SAToP or X.21, V.35… 2 CES
CESoP Sync/Async Supporting :
64 Cross- RS232, RS422, RS485,
Connects Sync/Async

2-C37.94 4-4WEM 4-CoDir 4-ContraDir 2-OLS STM1/4


2 C37.94 ports 4 Wire voice 4 Co-Directional 4 Contra- 2 Serial optical ports
2 E1 or T1 ports ports ports Directional ports Syn / Async serial
G.703, G.823 G.703, G.823 2 E1/T1 ports
4-C37.94
4 C37.94 ports STM1/4 transport
Smart SFP

© Belden | belden.com XTran 9


XTD-2110-A (DIN, 2 PSU inputs) with POE

Serial ports
Optical (SFP) LAN ports • 2x RJ45
• 2x GigE SFP • RS232: Rx, Tx, RTS, CTS, GND
• Pick up remote device data (e.g. IP • RS422: Rx, Tx
cameras) over fiber • RS485: Rx, Tx
• Pick up legacy applications (async)

Electrical LAN ports


WAN ports
• 4x GigE RJ45 (10/100/1000 base-T)
• 2x 1/10 GigE SFP+
• POE+
• 2x GigE SFP (including 100Base-FX)
• Sync-E support
• Sync-E support
• IEEE 1588 PTP Transparent Clock
• IEEE 1588 PTP Transparent Clock
• Pick up local device data over Cat6
• 1G or 10G ring along track
cable
• Meshing/Spurs are possible
• Provide POE power to IP cameras, Wifi
• Links can be encrypted (MACsec)
access points etc.

DIO Redundant Power input


• 2 Input, 2 Output • 2x 24-57VDC (for POE 50-57VDC)
• Monitor enclosure door contact • Solar Power, UPS
© Belden | belden.com XTran 10
XTR-2124-A (Rack mount, 2 PSU inputs) with POE

• 24 Ethernet Ports in total (4 WAN + 20 LAN access) • DIO


• 2x 1/10 GigE SFP+ • 2 Input, 2 Output (Connector on back)
• WAN or LAN • Redundant Power input
• MACsec ready (License based) • 2x 24-57VDC (Connectors on back)
• 2x GigE SFP • Note: POE+ operation requires 50-57VDC
• WAN or LAN • SD Card slot on the back of the node
• MACsec ready (License based) • easily swap configuration data in case of replacement
• 4x GigE Combo (SFP/RJ45) LAN ports (Routable*) • One of the Ethernet ports can optionally be used
• 16x GigE RJ45 POE+ LAN ports (Routable*) for management (TXCare)
• Stand-alone XTR-2100 networks are possible
• 2x Serial Ports (Optional) • Operating temperature range (forced cooling)
• RS232: Rx, Tx, RTS, CTS, GND • -30°C to +65°C (-22°F to +149°F, startup @ -20°C/-4°F )
• RS422: Rx, Tx • -30°C to +75°C (-22°F to +167°F, startup @ -20°C/-4°F )
(Extended temperature range)
• RS485: Rx, Tx
• Compatible with “Serial Ethernet” Service on XTran for • Size: 44x440x330 mm (HxWxD) (19”, 1HU)
asynchronous serial connections (*) Available in Phase 2

© Belden | belden.com XTran 11


E1/T1 Packetized
E1/T1 via
E1/T1 MPLS-TP XTran Network
WAN (via SFP on fiber) SAToP and
Module
CESoPSN
WAN XTran Node XTran Node
IFM1 IFM2 CSM IFM1 IFM2 CSM
4-E1-L 4-GC- 4-E1-L 4-GC-
LW LW

E1/T1
Port
LAN E1/T1 E1/T1
Links Links
PBX PBX
Router Router
Teleprotection Teleprotection

LAN: E1/T1 link (on copper) → external devices


WAN: MPLS-TP (on fiber, copper) → between XTran nodes
12
© Belden | belden.com
Ethernet → node internal XTran
SAToP

• SAToP (Structure-Agnostic Time division multiplexing over Packet)


• SAToP : full 2Mbps

© Belden | belden.com 13
CESoPSN

• CESoPSN (Circuit Emulation Service over Packet Switched Network)


• CESoPSN : only relevant timeslots sent via a fractional E1 frame

© Belden | belden.com 14
IEEE C37.94 Scenario

High Voltage

Protection Relay Protection Relay

Teleprotection Teleprotection

Fiber Optics Fiber Optics


IEEE C37.94 IEEE C37.94

XTRAN
MPLS-TP
Substation A Substation B
© Belden | belden.com 15
C37.94 to E1 (SAToP Mux/Demux)

© Belden | belden.com 16
Hitless Switching (CES only)

• Interface card duplicates packet and transmit over two independent tunnels
• Receiving-end buffers the fast path and forwards packets from the slow path
• Zero packet loss switch-over due to buffering fast path as standby path

C37/ /C37

© Belden | belden.com 17
C37.94 Clocking

© Belden | belden.com 18
7-SERIAL: Application example (RS232/422/485, X.21 & V.35)

XTran MPLS-TP XTran Network


Node WAN (via SFP on fiber)
Module Module
7-SERIAL 7-SERIAL

DCE DCE

Serial
Link Serial
Link

DTE e.g. SCADA


e.g. RTU DTE

© Belden | belden.com XTran 19


7-Serial Application Example (CES)

Station A Station B

DTE DCE DCE DTE

© Belden | belden.com
7-Serial Application Example (Serial Ethernet)
Station A Station B

Master Slave

Slave Slave

Station C Station D
© Belden | belden.com
G.703 CoDir 64kbps

© Belden | belden.com 22
SDH / SONET interworking

• Transparent transport STM-1 / OC-3


STM-1/OC-3 STM-1/OC-3
o Smart SFP S1/L1/L2 Optical
LSR LSR
o Ethernet PTP service, MPLS-TP protected LER LER
o Sync-E
LSR
• Transparent transport STM-4 / OC-12
o Smart SFP S1/L1/L2 Optical STM-4/OC-12 STM-4/OC-12

o Ethernet PTP service, MPLS-TP protected LSR LSR


LER LER
o Sync-E

LSR
• Grooming E1 into STM-1 (Channelized)
o Smart SFP S1 Optical and 16-E1-L E1

o Ethernet VLAN based service point to point or multipoint STM-1


service LER LSR
LER LER
E1

LSR
© Belden | belden.com XTran 23
Q&A

© Belden | belden.com XTran


Thank You
belden.com otnsystems.com

© Belden | belden.com 25

You might also like