You are on page 1of 2

Variable Vane Pumps

Performance Characteristics VV IVP Series Variable Displacement


P For Industrial Applications
Series Vane Pumps
IVP – 06 IVP – 11

Head Office - Pune


Eaton Fluid Power Limited
Hydraulics Division
145, Off Mumbai-Pune Road
IVP – 16 IVP – 22 Pimpri, Pune – 411018
Email ID: EnquiryIndia@Eaton.com

North East West South

North Zone - Delhi East Zone - Kolkata West Zone - Mumbai South Zone - Chennai

Eaton Fluid Power Ltd. Eaton Fluid Power Ltd. Eaton Fluid Power Ltd. Eaton Fluid Power Ltd.
913-914, 9th Floor, Matrix Towers, Office No. 203, VITS Luxury business hotels, NO-36, Nehru Street,
Best Sky Tower, 2nd Floor EL Floor, Andheri Kurla road, Off Old Mahabalipuram,
Netaji Subhash Place, Pitampura, Block No. D. N. 24, International airport zone, Sholinganallur
New Delhi - 110034 Sector V, Salt Lake Area Andheri East, Chennai - 600 119
Email ID: Kolkata - 700091 Mumbai - 400059 Email ID:
RajeshAtreja@Eaton.com Email ID: Email ID: ARSankaranarayanan@Eaton.com
Tel. No: +91 11 64569183 AbhishekChoudhury@Eaton.com SushilSKale@Eaton.com Tel. No: +91 44 44501559
Tel. No: +91 33 40040992 Tel. No: +91 22 40154819 / 20
South Zone - Bangalore
West Zone - Pune
Eaton Fluid Power Limited
Assistant General Manager- Sales Prestige Atrium,
Email ID: Unit 501, 4th floor,
Application Information AmodAKavishwar@Eaton.com Central Street,
Tel. No: +91 20 30611126 Bangalore,
 The rotation of IVP pump is clockwise when viewed from the shaft end. Karnataka – 560002
 The drain pipe is directly connected to the oil tank and the position must be below the level of oil. West Zone - Gujarat Email ID:
2
 Keep the suction pressure within -0.3 kgf/cm at the suction port. JayanthkumarBS@Eaton.com
Deputy Manager Sales
 Pressure adjusting screw is turned clockwise to increase the pressure and counterclockwise to decrease the pressure. Tel. No: +91 80 49012203
Email ID:
 Flow adjusting screw is turned clockwise to increase flow and counterclockwise to decrease flow. DharmeshMody@Eaton.com South Zone - Hyderabad
 For proper alignment of pump and electric motor shaft, the eccentricity between them must be kept within 0.05 mm and Mob. No: +91 9727382030
o
the eccentric angle error between them must be kept within 1 . Eaton Fluid Power Ltd.
2 2
 When pressure is under 70 kgf/cm the viscosity of oil must be within 30-50 cSt, when pressure is over 70 kgf/cm the H. No: 8-3-960/10,
o
viscosity of oil must be within 50-70 cSt, at the temperature of 40 C. # 102, Anand Bhavan,
 When first time operation, the pump should be at “No-load state, on delivery side and be repeated on and off the Srinagar Colony Main road,

electric motor a number of times” to make sure the air has been bled out of the system. Hyderabad,
Andhra Pradesh – 500073
© 2014 Eaton Email ID:
All Rights Reserved
Printed in India JagadishKalshetty@Eaton.com
January 2014 Mob. No: +91 9866982752
Model Code Installation Drawings Technical Data
The following 14-digit coding system has been developed to identify standard configuration options for the Variable Vane Pump. Use
this model code to specify a pump with the desired features. All 14 digits of the code must be present to release a new product
IVP – 06 / IVP – 11
Displacement Delivery at no load Pressure Shaft Speed Range Max.
number for ordering. (l/min) (rpm) Weight
cc/rev Adj. Range Pressure
3 2 2 (kg)
(in /rev) 1500 rpm 1800 rpm (kgf/cm ) Max. Min. (kgf/cm )
10-20 (A) 20 5.0
I V P * * R * * 3 0 * I N B 6.6 15-35 (B) 35 5.0
10 12 1800 800
1 2 3 4 5 6 7 8 9 10 11 12 13 14 (0.40) 30-55 (C) 55 5.0
50-70 (D) 70 5.0
10-20 (A) 20 5.0
1, 2, 3 IVP Series 9, 10 Pump Design Number 15-35 (B) 35 5.0
11.0
17 20 1800 800
All models [Subject to change. Installation (0.67) 30-55 (C) 55 5.0
IVP Industrial Variable Vane Pump 30
dimensions remain unaltered for designs 30-39] 50-70 (D) 70 5.0
15-35 (B) 35 9.7
4, 5 3
Size / Displacement cc/rev (in /rev) 11 Control Pressure Ranges 16.5 20-70 (E) 70 9.7
25 30 1800 800
(1.00) 50-105 (F) 105 9.7
06 6.6 (0.40) A 20 Bar (For All Sizes)
70-140 (G) 140 9.7
11 11.0 (0.67) B 35 Bar (For All Sizes) 15-35 (B) 35 9.7
22.2 20-70 (E) 70 9.7
16 16.5 (1.00) C 55 Bar (For All Sizes) 35 40 1800 800
(1.35) 50-105 (F) 105 9.7
22 22.2 (1.35) D 70 Bar (For All Sizes) 70-140 (G) 140 9.7

E 70 Bar (For 16 & 22 cc Sizes) # If required to be used for different operating conditions, please contact EATON representative.

6 Output Rotation (Viewed from output shaft end) F 105 Bar (For 16 & 22 cc Sizes) IVP – 16 / IVP – 22
R Right Handed CW G 140 Bar (For 16 & 22 cc Sizes)
Features
 High efficiency, high-pressure operation.
7, 8 Mounting Flange / Port Connections 12, 13, 14 Control Design Number  Extremely low vibration and noise level.
 Instant and sharp cut-off characteristics.
SAE A 2-bolt with straight keyed shaft; Inlet Port – ½”
PS INB For all models  Sturdy structure for high efficiency and long service life.
Outlet Port – 3/8” (For Size 6 & 11)
Ø95 mm 4-bolt with straight keyed shaft; Inlet Port – 3/4”  Easy adjustment in handling and maintenance.
PF
Outlet Port – 1/2” (For Size 16 & 22)

You might also like