Professional Documents
Culture Documents
TT2780
Temperature head transmitter
For resistance thermometers Pt100, settable using a PC,
for installation in a sensor head Form B, BUZ, BUZ-H
4
6. 2008
TI088R/09/en
51003515
TEMATEC GmbH Data Sheet TT2780 Page 2/5
Measurement system The TT2780 temperature head transmitter is a two wire transmitter with an analog output. It has
measurement input for resistance thermometer Pt100 in 2-, 3- or 4-wire connection. Setting up of the
TT2780 is done using the configuration kit.
Input values
Measurement value Temperature
Measurement range
Type Measurement ranges min. measurem. range
Pt100 -200 to 650 °C (-328 to 1202 °F) 10 K
accord. to IEC 60751 -50 to 250 °C (-58 to 482 °F) 10 K
• Connection type: 2-, 3- or 4-wire connection
cable resistance compensation possible in the 2-wire system (0 to 20 Ω)
• Sensor cable resistance: max. 11 Ω per cable
• Sensor current: ≤ 0.6 mA
Output values
Output signal analog 4 to 20 mA, 20 to 4 mA
Current limit ≤ 23 mA
Auxiliary energy
Electrical connection
Performance characteristics
Response time 1s
a. % is related to the adjusted measurement range (the value to be applied is the greater one)
b. as option
3. % is related to the adjusted measurement range (the value to be applied is the greater one).
6. 2008
TEMATEC GmbH Data Sheet TT2780 Page 4/5
Installation
Installation conditions • Installation angle: No limit
• Installation area: Connection head accord. to DIN 43 729 Form B; TAF10 field housing
Environment
Ambient temperature range −40 to +85 °C (-40 to 185 °F)
Condensation allowable
Mechanical construction
Design, dimensions
Material Housing: PC
Potting: PUR
Human interface
Remote operation Configuration
Configuration kit, configurable on PC software programme
Starting from version R2.00.00 of the TT2780 A the temperature head transmitter is configurable without
voltage supply.
6. 2008
TEMATEC GmbH Data Sheet TT2780 Page 5/5
Ordering information
How to order
Head transmitter TT2780
PC programmable temperature transmitter, configurable measurement range for Pt100, analog output 4 to 20 mA, 2-wire technology, fail-
ure mode to NAMUR NE43, for mounting in Form B head to DIN 43729
Certification
A Non-hazardous areas
Programming
1 PC-programmable
TT2780- ⇐ Order-Code
6. 2008