AUDIT CRITERIA
CRITERIA
Warrendale, PA 15086-7527 AEROSPACE Revised 13-JUL-2020
Nadcap
AUDIT CRITERIA FOR CHEMICAL PROCESSING and NONDESTRUCTIVE TESTING
For Etching and Etch Inspection Processes
(Anodic Etch, Blue Etch Anodize, Macrostructure Etch, Nital/Temper Etch, Pre-Penetrant Etch)
*TO BE USED ON AUDITS STARTING ON OR AFTER 11-OCT-2020*
1. GENERAL REQUIREMENTS
This Audit Criteria is administered per the MoU between the CP and
NDT Task Groups:
PRI operating procedures provide that "This report is published by PRI to advance the state of technical, engineering, and quality
sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent
infringement arising there from, is the sole responsibility of the user”
PRI values your input. To provide feedback on this document, please contact the appropriate commodity staff engineer. (Contact
information is located at http://www.eauditnet.com under “Contact Us”.)
t-frm-1115 21-May-2020
Nadcap AC7108/2 Revision G -2-
1.3 One complete job audit, both processing and inspection, is required for
each Etch Inspection method (Anodic Etch, Blue Etch Anodize, Macro-
Structure Etch, Nital/Temper Etch) in the scope of the audit, and a
processing only job audit is required for Pre-Penetrant Inspection if in
the scope of the audit. If there are less than three etch inspection
methods (Anodic Etch, Blue Etch Anodize, Macro-Structure Etch,
Nital/Temper Etch), additional job audits of the inspection only part of
the process shall be carried out so that at least three jobs are audited
for inspection.
3.1.1 Has the competency for all processing personnel been defined? YES NO
3.1.2 Is there evidence that the effectiveness of these actions was YES NO
evaluated?
Nadcap AC7108/2 Revision G -3-
3.1.3 Does the Auditee define and operate a system to ensure competencies YES NO
are maintained?
3.2.1 Does shop paper/traveler, which accompanies each lot, contain as a YES NO
minimum the following information:
Compliance Assessment Guidance: See AC7108 for definition of shop
paper and the Chemical Process Audit Handbook for an example of a
shop paper.
3.2.1.3 Part identification, quantity of parts, and when required material and/or YES NO
material condition?
Compliance Assessment Guidance: The material and/or material
condition are required on the traveler unless one of the following
applies: it does not influence the process steps/sequence; when the
customer specifies the process steps, e.g. repair manual sequence or
processing to defined steps on customer traveler; if it is readily
available to the operator in some other manner, e.g. drawing; part is an
assembly/kit.
3.2.1.4 A description of the type and quantity of the test pieces when required YES NO NA
by the specification?
Compliance Assessment Guidance: NA applies if test pieces were not
required for any of the jobs audited.
Type may be substituted by material and size.
Reference to a defined test piece, e.g. test piece drawing, is
acceptable.
3.2.1.5 A step for each process performed, defining the required process YES NO
parameters/ranges and referencing applicable internal process/or
Nadcap AC7108/2 Revision G -4-
3.2.1.5.7 Post-process steps including cleaning, drying, de-masking and removal YES NO
of fixturing and racking?
3.2.1.5.13 Documentation of rework that is traceable to the shop paper / traveler YES NO NA
and all processing performed on the parts?
Compliance Assessment Guidance: NA applies if no rework observed
during the audit.
3.2.2 Do buy-off steps comply with AC7108 para 2.4 and Appendix E and YES NO
were they properly bought off and dated?
3.2.3 Are all process parameters defined in AC7108 App D recorded and YES NO NA
traceable to the route card/traveler?
Compliance Assessment Guidance: NA applies if the design authority
has specifically stated that the process parameters need not be
recorded.
3.3.3 Does the compressed air supply used for production include YES NO NA
particulate, moisture, and oil filters with scheduled maintenance and
point of use air inspection for air cleanliness?
Compliance Assessment Guidance: NA applies if compressed air is not
used in the scope of this Audit Criteria. Tank agitation is sometimes
achieved by air blowers, this is not compressed air.
Compressed air is commonly used for drying parts after processing and
for abrasive blasting. A mirror test or filter paper test are common
Nadcap AC7108/2 Revision G -6-
3.3.4 Are hoists and other lifting equipment labeled as to capacity? YES NO NA
Compliance Assessment Guidance: NA applies if no hoists or lifting
equipment is used.
3.3.5 Are timers available, suitable to the purpose, calibrated and visible or YES NO
audible from the tanks?
Compliance Assessment Guidance: Timers used for process control
must be calibrated.
Timers include wall clocks and watches if the operators use them for
timing process parameters.
3.3.6.1 Are tanks labeled to include identification number, contents and YES NO NA
temperature ranges?
Compliance Assessment Guidance: NA applies if processes do not
use tanks (e.g. local etching)
Tank number is not required if the tank is uniquely identified by some
other means.
3.3.6.2 Are tank labels consistent with procedures, shop paper and logs? YES NO NA
Compliance Assessment Guidance: NA applies if processes do not
use tanks, e.g. local etching
3.3.6.3 Are tanks and work surfaces maintained free of corrosion and chemical YES NO
spillage detrimental to the process?
3.3.6.4 Are spray and immersion rinse tanks clean, clear, free-running or YES NO
monitored for contamination levels?
Compliance Assessment Guidance: Does not apply to drag-out tanks if
adequate rinsing is provided afterward.
3.3.6.5 Are spray and immersion rinse tanks situated in a sequence to prevent YES NO
cross contamination of process tanks?
3.3.6.6 Do spray and immersion rinse tanks assure adequate neutralization YES NO
and/or removal of process chemicals?
Compliance Assessment Guidance: Particular attention must be given
to parts such as small diameter tubes. Processor should have or make
provision for auxiliary rinsing.
Nadcap AC7108/2 Revision G -7-
3.3.6.7 Is water used for final rinse, including spray rinses, de-ionized or YES NO NA
monitored for halogen content when required by specification?
Compliance Assessment Guidance: NA applies if the specification
does not require de-ionized water or monitoring for halogen content.
3.3.6.8 Are fixtures, workbars, electrical connections, and hard masking free of YES NO NA
corrosion and physical damage detrimental to the process while in use?
Compliance Assessment Guidance: NA applies if fixtures, electrical
connections workbars or hard masking were not used for the jobs
audited.
3.3.6.9 Are tanks that require uniformity of temperature and solution YES NO NA
concentration agitated?
Compliance Assessment Guidance: NA applies for processes that do
not utilize tanks or where stratification does not occur.
Agitation may be continuous or prior to use.
The Auditee should be able to demonstrate temperature uniformity of
the tank when in use.
3.3.6.10 Are tanks with defined temperature ranges operating within the posted YES NO NA
range?
Compliance Assessment Guidance: NA applies where none of the
tanks have a defined temperature range.
3.3.6.11 Are tanks of sufficient volume and dimensions to contain hardware YES NO
during processing and assure sufficient coverage of parts?
Compliance Assessment Guidance: For parts requiring processing of
selective areas, entire area to be processed must be immersed.
Other situations such as double dipping require specification or
customer approval.
3.3.6.12 Are fixtures and masking designed as such so they do not entrap air or YES NO NA
processing solutions on parts?
Compliance Assessment Guidance: NA applies if masking and fixtures
were not used for the jobs audited.
3.3.6.13 Is fixturing and racking design adequate so that, when hardware is YES NO NA
positioned for rinsing, there is adequate process solution neutralization
and removal and does it minimize process solution and rinse water
drag-out and cross-contamination of process tanks?
Compliance Assessment Guidance: NA applies if fixturing and racking
is not used for the jobs audited
3.3.6.14 Is work electrically isolated from the electrical power supply of hoists YES NO NA
and other lifting equipment if that equipment is left connected to the
work during processing?
Compliance Assessment Guidance: NA applies if; no electrically
powered hoists or lifting equipment are used, electrically powered
hoists or lifting equipment is disconnected during processing, or
Nadcap AC7108/2 Revision G -8-
3.3.7.1 Are power supplies equipped with calibrated ammeters, voltmeters and YES NO
ramp rate controls (if equipped with ramp rate control)?
Compliance Assessment Guidance: For those tanks equipped with
digital or paper chart recorders documenting voltage/ amperage, and
time, calibration of the ramp rate control is not required provided the
ramp rate can be verified from the recorded data.
3.3.7.2 Does each tank have dedicated meters that monitor actual power at the YES NO
tank?
Compliance Assessment Guidance: Some rectifiers power more than
one tank or more than one station within a tank. Each tank or station
must have its own meters so that each job can be separately tracked.
3.3.7.3 Is the resolution of the power meters sufficient for the voltage and YES NO
amperage range specified in the shop paper/traveler?
Compliance Assessment Guidance: Resolution of ammeter/voltmeter
needs to be sufficient to properly control processing. For example, an
ammeter with a scale of 0-3000 amps in 100 amp increments would not
provide sufficient resolution to verify that 64 amps are being applied.
3.3.7.4 Are rectifiers identified to the tank which they service, or if not does YES NO
each tank have individual rheostat?
Compliance Assessment Guidance: If multiple rectifiers per tank or
portable rectifiers are used, the rectifier must be traceable to individual
hardware.
3.3.7.5 If a power failure occurs, is there a mechanism that requires the YES NO
operator to physically restart the power supply?
Compliance Assessment Guidance: Process must not be allowed to
restart on its own without operator knowledge or part damage could
result from extended processing.
Momentary contact type switches break the circuit when power is lost;
toggle or rotary snap type switches do not.
3.3.7.6 For Blue Etch Anodize, is the power supply ripple level controlled at 6% YES NO NA
maximum at 30V, and no load?
Compliance Assessment Guidance: NA applies if Blue Etch Anodize is
not in the scope of the audit.
Nadcap AC7108/2 Revision G -9-
3.3.7.7 For Blue Etch Anodize, are power supplies capable of increasing YES NO NA
voltage from 0 to 30V in 1 to 3 seconds?
Compliance Assessment Guidance: NA applies if Blue Etch Anodize is
not in the scope of the audit.
If voltage control has a ramp rate control, it must be able to change the
voltage from 0 to 30V in 1 to 3 seconds.
Manual controls and automatic voltage-hold controls should be able to
meet this requirement.
3.3.7.8 For Blue Etch Anodize, are power supplies equipped with a ramp YES NO NA
control or a resistor with automatic cut-out to minimize arcing?
Compliance Assessment Guidance: NA applies if Blue Etch Anodize is
not in the scope of the audit.
A non-ramp-controlled rectifier should be equipped with a time actuated
switch that, in less than three seconds after turning on the current, cuts
out a 1.2-ohm resistor installed in series with the load. The resistor
reduces the initial surge of current and thereby reduces the chance of
arcing.
A ramp-controlled rectifier should have a voltage/current regulation with
an adjustable current ramp regulator that has a zero to maximum rise
time between one and three seconds.
3.3.8.1 Is fixturing and rack design, and the arrangement of workbars and YES NO
anodes/cathodes, such that electrical contacts are solid but preclude
potential pressure damage or electrical arcing?
3.3.8.2 Are tanks equipped with cathodes that can be reconfigured as needed, YES NO NA
or are conforming auxiliary electrodes used, for processing hardware
with variable geometric configuration or for variable lot sizes?
Nadcap AC7108/2 Revision G - 10 -
3.3.8.3 Are there procedures in place to ensure that, unless otherwise YES NO
specified, the part is not introduced, moved, or removed from the
etching process when current is applied (power on)?
3.3.8.4 Are fixtures designed to preclude the possibility of electrical contact YES NO
(short circuit) between the hardware and the opposite charged
electrode?
Compliance Assessment Guidance: Short circuits can cause arcing and
damage parts
Fixtures should hold hardware in an orientation that prevents parts from
coming into contact with electrodes.
Nonconductive shields may also be used between electrodes and parts
to prevent arcing.
3.3.8.5 Are contacts of sufficient area to carry the required current load without YES NO
overheating/deteriorating?
Compliance Assessment Guidance: Contacts should be designed and
maintained to obtain sufficient contact area and contact pressure.
Observe contact areas on parts for signs of arcing, heat discoloration or
other surface degradation.
3.3.8.6 If required by the customer, are contact locations in the specified area? YES NO NA
Compliance Assessment Guidance: This question is NA if contact
locations are not specified by the customer.
Contract review and planning procedures must address contact
locations.
Shop papers must show contact locations or call out specific fixture
with contacts in correct locations.
Review specification and engineering drawing for contact locations and
observe that fixture contacts are in the specified area.
3.3.8.7 Are fixture contact locations cleaned periodically to ensure that YES NO
corrosion, dirt, and grease are removed?
Compliance Assessment Guidance: Fixture contacts must be
maintained to prevent arcing.
Maintenance procedures must address fixture maintenance.
Look for records of fixture maintenance and observe fixture contacts for
signs of corrosion, dirt, grease or other contamination.
Nadcap AC7108/2 Revision G - 11 -
3.3.9 Ovens for Thermal Treatments at a set point above 250°F (121°C). SECTION NA
Compliance Assessment Guidance: NA applies if processing does not
require thermal treatments at a set point above 250°F (121°C), or if the
same oven has been audited in conjunction with an AC7108 Audit
Criteria.
See AC7108 for definition of Thermal Treatment. Part drying is not
considered a Thermal Treatment.
The only pyrometry requirements to be verified are those required to
answer the following questions.
3.3.9.1 For each oven that operates at a set point above 250ºF (121ºC), does YES NO
the Auditee identify?
3.3.9.2 Does the defined operating range and uniformity requirement meet YES NO
specification requirements for which the oven is used?
3.3.9.3 Are parts only placed within the defined working volume of the oven? YES NO
3.3.9.4 Does the oven have at least one control sensor in each control zone, YES NO
attached to a control instrument that displays and controls
temperature?
3.3.9.5 Does the oven have a recording instrument that records the displayed YES NO
temperature for each control zone?
3.3.9.6 Does the oven have over-temperature protection in each control zone? YES NO
3.3.9.8 Is instrument calibration accuracy ±2°F (±1.1°C) and is sensitivity within YES NO
3°F (2°C)?
3.3.9.10 Are chart recorder (circular and strip) speed(s) calibrated/verified at YES NO NA
least annually and accurate to within ±3 minutes per hour?
Compliance Assessment Guidance: NA applies if temperature recorder
is electronic/digital data collection type.
3.3.9.11 Is resolution of the chart recorder equal to or better than ±10ºF (6ºC)? YES NO NA
Compliance Assessment Guidance: NA applies if temperature recorder
is electronic/digital data collection type.
3.3.9.12 Are system accuracy tests (SATs) carried out in accordance with, or YES NO
certified to, AMS2750?
Compliance Assessment Guidance: Also called a Probe Check.
3.3.9.12.1 Is a SAT performed after any maintenance that could affect the SAT YES NO
result?
Compliance Assessment Guidance: Examples include replacement of
thermocouple(s) and re-calibration of the instrument when any
adjustment has been made.
3.3.9.12.2 Are SATs performed every two weeks unless requirements in YES NO
AMS2750 for less frequent SATs are met?
Compliance assessment Guidance: SATs may be done less frequently,
e.g. monthly, if the oven control, maintenance and use meets
requirements in AMS2750 for the frequency used. It is the Auditee’s
responsibility to demonstrate compliance to requirements if less
frequent SATs are done.
If an oven is used infrequently at a set point above 250°F (121°C) then
check that an SAT has been done no more than 2 weeks prior to use.
3.3.9.14 Are temperature uniformity surveys (TUSs) carried out in accordance YES NO
with, or certified to, AMS2750?
3.3.9.14.1 If the highest and lowest test temperatures are more than 600°F YES NO NA
(335°C) apart, are uniformity surveys performed at a temperature within
each range as defined during the initial survey?
Compliance Assessment Guidance: NA applies if the qualified
operating range is not more than 600°F (or 335°C).
3.3.9.14.2 Over a period of 12 months, are TUSs performed at the minimum and YES NO NA
maximum temperatures of the qualified operating range?
Compliance Assessment Guidance: NA applies if an oven operates at a
single set point.
3.3.9.14.4 Do TUS results show uniformity to meet the process specification YES NO
requirements?
Compliance Assessment Guidance: If the process specification
requires the parts to be treated at 275-300°F (135-149°C) then check
the set point plus the uniformity and the set point minus the uniformity
are within 275-300°F (135-149°C).
3.3.9.15 Does the Auditee have a procedure(s)/instruction(s) for the pyrometry YES NO NA
test(s) (instrument calibration, SAT, TUS) that are performed internally
and are they compliant to AMS2750 and indicate compliance to
AMS2750?
Compliance Assessment Guidance: NA applies if all pyrometry tests
are done by a sub tier provider.
3.3.10 Ovens for Thermal Treatments with a set point at or below 250F (121C) SECTION NA
or for miscellaneous Heating Processes, e.g. Part Drying.
Compliance Assessment Guidance: NA applies if no thermal
treatments at or below 250ºF (121ºC) or other miscellaneous heating
processes are performed within the scope of the audit, if these
treatments are performed in an oven controlled to section 3.3.9, or
done in conjunction with an AC7108 Audit Criteria.
Equipment that is not fully enclosed but provides this type of thermal
treatment shall be considered as an oven for the purpose of this audit.
3.3.10.2 Do procedures require and records show a periodic check is performed YES NO
to ensure the minimum (if specified) and maximum temperatures within
the working zone meet requirements?
Compliance Assessment Guidance: The working zone is defined by
the placement of the thermocouples used to do the periodic check,
parts must be placed within this zone.
For certain equipment (e.g. spin dryers, conveyor ovens) a periodic
temperature survey is not feasible and periodic testing of parts on
removal from the dryer is acceptable to prove the temperature does not
exceed requirements.
If there is no minimum temperature requirement and the drying space is
fed by heated air, then a periodic check of the input air temperature is
acceptable.
Nadcap AC7108/2 Revision G - 14 -
3.4.1 Are there assigned responsibilities for review and approval of analysis YES NO
results, authorization of reanalysis, calculation of process solution
additions and corrections, and the preparation and approval of analysis
procedures as required?
3.4.2 Are these responsibilities performed by a qualified individual and are YES NO
their job responsibilities, job specification and qualifications
documented?
Compliance Assessment Guidance: If there is no on-site technical
expertise in simple chemical analysis techniques, witness a typical
titration or other test to confirm minimal skill levels in using a pipette,
reading a burette, standardizing a pH meter, etc.
3.4.3 If solution analysis, or testing of periodic process control test pieces YES NO NA
(e.g. IGA/EGP testing), is subcontracted, is the sub tier provider
approved by the Subscriber for analysis and testing, or accredited to
AC7101/1, or accrdedited to ISO17025 for analysis or testing by an
ILAC Registrar, or accredited to AC7108/4?
Compliance Assessment Guidance: NA applies if no sub-contract
analysis and no sub-contract testing of periodic process control test
pieces.
For AC7108/4, the sub-tier’s scope of accreditation shall cover solution
analysis (if applicable) and any applicable test method (IGA/EGP
testing is covered by AC7108/4 App B3, Metallography).
3.4.5 Do the solution control records contain the following information for YES NO
each tank monitored:
Nadcap AC7108/2 Revision G - 15 -
3.4.5.6 Are operating tolerances based on, multiple where applicable, YES NO
specification / technical datasheet requirements, e.g. temperature
range, composition range(s), pH range, conductivity range, etch rate?
Compliance Assessment Guidance: The Chemical Process Audit
Handbook provides an example of a Solution Matrix which may be
used as a tool to help meet this requirement.
3.4.6 Do records show that corrections are made in a timely manner and that YES NO
the solution is maintained to defined requirements?
3.4.8.2 Sample collection which assures that the sample is representative of YES NO
the bath solution and operating condition and precludes sample
contamination?
Compliance Assessment Guidance: Bath should be at correct level,
agitated and at correct temperature prior to sampling.
3.4.9 Are chemicals used as reagents during analysis General Laboratory YES NO NA
Reagent Grade or better according to customers/ National
requirements?
Compliance Assessment Guidance: NA applies if solution analysis is
performed by a sub tier provider.
3.4.11 Does water used for analysis and test purposes meet the definition of YES NO NA
Laboratory Water, see AC7108 section 2.4, and do records support it,
e.g. certificate of analysis, test log?
Compliance Assessment Guidance: NA applies if solution analysis is
performed by a sub tier provider.
3.4.12 Are standards with a limited shelf life properly labeled to preclude YES NO NA
usage after expiration date?
Compliance Assessment Guidance: NA applies if solution analysis
performed by a sub tier provider.
3.4.13 Are shelf-life disciplines documented and maintained for standards YES NO
susceptible to deterioration (e.g., evaporation of liquid standards,
reaction with glass storage containers, photochemical reactions)?
3.4.14 Are titration solutions certified and traceable to national standards or YES NO NA
standardized against appropriate documented, certified reference
standards, and are they monitored for stability and protected against
degradation?
Compliance Assessment Guidance: NA applies if solution analysis is
performed by a sub tier provider.
Nadcap AC7108/2 Revision G - 17 -
3.4.15.1 Is standardization of the pH meter carried out daily, prior to first use, YES NO
using a minimum of two buffer solutions that represent both the acid
and/or alkali range as applicable?
Compliance Assessment Guidance: The pH buffers used to
standardize the meter need to represent the acid and/or alkali ranges
but do not need to bracket the full pH range of samples being tested.
Typical pH kits include pH 4, 7 and 10 buffer solutions and the use of
the most appropriate two is acceptable.
3.4.15.2 Are certified, commercial-grade or better buffer solutions within shelf- YES NO
life expiration date?
3.4.16.1 Are stock removal (etching) rates determined and posted, or logged, in YES NO
a manner readily accessible by the operator?
Compliance Assessment Guidance: Determine that the procedure or
work instructions call out etch rates and how they are to be recorded.
Some Primes require daily etch rate data to be posted.
3.4.16.2 Are stock removal rates determined daily prior to processing hardware YES NO
unless alternate frequency is permitted by the specification?
Compliance Assessment Guidance: Specific shop paperwork defining
and recording the processing of etch rate test pieces (except immersion
times) is not required.
3.4.16.3 Are stock removal (etch rate) panels, made from the same (or similar) YES NO
alloy, temper and surface finish as applicable to customer
requirements?
Compliance Assessment Guidance: Not all customer specifications
require the same temper and surface finish for etch rate panels,
however if specified, the Auditee must address this in their stock
removal rate process.
3.4.16.4 If the Auditee re-uses etch rate test panels is the re-use compliant with YES NO NA
specification?
Compliance Assessment Guidance: NA applies if the Auditee does not
re-use etch rate test panels or if the specification is silent on the re-use
of etch rate test panels.
Nadcap AC7108/2 Revision G - 18 -
3.4.16.5 If the Auditee re-uses etch rate test panels is re-use of test panels YES NO NA
controlled to ensure consistent etch results when compared to new test
panels?
Compliance Assessment Guidance: NA applies if the Auditee does not
re-use etch rate test panels or if done per customer requirements.
Auditee should be able to provide data that demonstrates the etch rate
of a panel used the maximum number of times is similar to the etch rate
of new test panels.
3.4.16.6 Is etch rate determined by weight loss unless otherwise specified by the YES NO
customer?
3.4.16.7 Is etch immersion time and weight loss data recorded? YES NO NA
Compliance Assessment Guidance: NA applies if the cognizant
engineering authority has specifically stated that the process
parameters need not be recorded.
3.4.16.8 Is equipment used for determination of etch rate calibrated over its YES NO
range of use and to an accuracy that is better than 0.5 of a decimal
place of the required measurement unit, or if not defined better than 5%
of the delta being measured?
Compliance Assessment Guidance: If the specification requires the
measurement instrument to measure to 0.001 units then it must be
accurate to ≤0.0005 units
If the specification is silent on instrument accuracy then it must be
better than 5% of the minimum expected delta. For example, if the
difference of the before and after measurement delta, based on the
slowest etch rate, is 0.137 units then it must accurate to 0.007 units.
3.4.17.1 Is there an internal procedure covering the test method that identifies YES NO NA
the specifications to which it is compliant?
Compliance Assessment Guidance: NA applies if the test is performed
by a sub tier provider.
3.4.17.2 Is the person doing the testing identified as trained/competent to do the YES NO NA
test?
Compliance Assessment Guidance: NA applies if the test is performed
by a sub tier provider.
3.4.17.5 Are precautions taken to prevent cutting or grinding induced specimen YES NO NA
damage?
Nadcap AC7108/2 Revision G - 19 -
3.4.17.6 Do metallographic mounts display good edge retention with minimal YES NO NA
edge rounding and with no gap between specimen and mount media?
Compliance Assessment Guidance: NA applies if the test is performed
by a sub tier provider.
3.4.17.8 Does the test procedure specify the magnification to be used for YES NO NA
dimensional measurement?
Compliance Assessment Guidance: NA applies if the test is performed
by a sub tier provider.
3.4.17.9 Are the filar eye-pieces used for thickness measurement calibrated YES NO NA
using stage micrometers?
Compliance Assessment Guidance: NA applies if the test is performed
by a sub tier provider.
3.4.17.11 Does the review also include trend analysis and action if negative YES NO NA
trends are identified?
Compliance Assessment Guidance: NA applies when the test is done
as a batch/lot acceptance test and not a periodic process performance
test.
3.4.17.12 If testing is performed by a sub tier provider is the sub tier provider YES NO NA
listed on the Auditee's Approved Supplier List and is it approved by
customer if required.
Compliance Assessment Guidance: NA applies if the test is performed
in-house.
3.4.18.2 Is there specific shop paperwork (router, etc.) which is traceable to the YES NO
standards, or known defect test pieces, which specifies how they are to
be processed and which tank they are processed in?
Nadcap AC7108/2 Revision G - 20 -
3.4.18.3 Are the process parameters listed in AC7108 Appendix D recorded for YES NO
the processing of Etch Inspection standards and known defect test
pieces?
3.4.19.1 Has the competency for all personnel functions affecting conformity to YES NO
chemical process requirements been defined, including processing
personnel, testing/inspection personnel and planning personnel?
3.4.19.2 For those functions identified in 3.3.19.1, do records show that training YES NO
or other actions were taken to achieve the necessary competence?
3.4.19.3 Is there evidence that the effectiveness of these actions was YES NO
evaluated?
3.4.19.4 Does the Auditee define and operate a system to ensure competencies YES NO
are maintained?
3.5.1.1 Are parts moved between tanks without undue delay such that process YES NO
quality is not affected?
Compliance Assessment Guidance: Time delay between certain
process steps may be critical.
It is acceptable for parts to dry back from edges in a regular pattern,
particularly when removed from hot tanks or on vertical surfaces.
3.5.1.2 Are test pieces processed through the cleaning solutions with the YES NO NA
hardware they represent?
Compliance Assessment Guidance: NA applies if test pieces aren't
required, e.g. testing may be performed on hardware.
Nadcap AC7108/2 Revision G - 21 -
3.5.1.3 Are cleaning materials compatible with the parts being processed? YES NO
Compliance Assessment Guidance: Refer to specifications for
acceptable cleaning solutions. Pay particular attention to assemblies
that are made up of different materials, previously deposited coatings,
and braze/solder joint material.
3.5.2.1 Is cathodic cleaning prohibited with high strength steels of 180 ksi and YES NO NA
greater, unless otherwise approved by the customer?
Compliance Assessment Guidance: NA applies if high strength steels
are not processed or if Auditee does not possess cathodic cleaning
capability.
3.5.2.2 Does the processor have adequate controls in place to ensure water YES NO NA
break free surfaces are obtained prior to continuation of processing?
Compliance Assessment Guidance: NA applies only for barrel and/ or
automated lines unless the specification specifically requires a water
break free test.
Some customers or specifications may require documentation of the
water break free test.
3.5.3.1 Are procedures and controls in place to assure proper grit size and YES NO
media type are used?
3.5.3.2 Are procedures and controls in place to assure proper particle size YES NO NA
distribution is maintained within requirements?
Compliance Assessment Guidance: NA applies if mechanical cleaning
other than abrasive blasting is performed.
Nadcap AC7108/2 Revision G - 22 -
3.5.3.3 Are procedures and controls in place to minimize cross contamination YES NO
of alloys during mechanical cleaning (e.g., aluminum and iron based
alloys)?
Compliance Assessment Guidance: This can be accomplished through
media changeout, dedicated blast equipment, etc.
3.5.3.4 When abrasive blast techniques are used, are off-set distances, YES NO NA
pressures, and media recorded?
Compliance Assessment Guidance: NA applies if mechanical cleaning
other than abrasive blasting is performed or if the cognizant
engineering authority has specifically stated that the process
parameters need not be recorded.
If these parameters are not defined by customer specification,
appropriate parameters may be derived from test results or references
such as MIL-STD-1504, that will provide this information for various
alloy types and media types. For manual blasting, recording offset as a
range is acceptable.
Offset distance does not need to be recorded if it is controlled by
fixturing or visual aids, see the Chemical Processing Audit Handbook
3.5.3.5 Are standards used to evaluate surface finish as required by customer YES NO NA
or specification?
Compliance Assessment Guidance: NA applies if no surface finish
requirements are imposed.
Visual comparison standards are acceptable, as well as profilometer
measurements.
3.5.3.6 Has hardware been visually checked and documented to verify YES NO
corrosion, oxides, scale, and abrasive media have been removed?
Compliance Assessment Guidance: Visual in-process inspection must
be performed and recorded prior to the next operation.
3.5.4.1 Are procedures in place for masking prior to cleaning, for visual YES NO
inspection of adequate masking before and after cleaning, and for re-
masking when damaged during mechanical cleaning?
Compliance Assessment Guidance: Planning procedures must address
masking sequence, inspection and repair.
3.5.4.3 Are masking materials specifically defined on shop papers or called out YES NO
in referenced instructions?
Nadcap AC7108/2 Revision G - 23 -
3.5.4.4 If masking materials are not specifically defined on shop papers, are YES NO NA
the actual masking material types used recorded and traceable to the
route card?
Compliance Assessment Guidance: NA applies if the masking
materials to be used are specifically called out on the shop papers.
3.5.4.5 Is masking material compatible with hardware and process conditions? YES NO
3.5.4.6 Are adhesives, masking material, markings, and residual chemicals YES NO
removed after processing?
Compliance Assessment Guidance: Maskants that are compatible with
thermal operations may be removed after thermal processing, else they
shall be removed before thermal processing
3.5.5.1 Do procedures provide for surface activation of cobalt and nickel base YES NO NA
alloys prior to etching?
Compliance Assessment Guidance: NA applies if nickel and cobalt
alloys are not processed.
3.5.5.2 Have all surfaces to be etched had oxide and scale removed prior to YES NO NA
etching?
Compliance Assessment Guidance: NA applies if parts are free from
oxide and scale.
3.5.5.3 When etching surfaces consisting of two different alloys with different YES NO NA
etching times specified, is the shorter etching time used?
Compliance Assessment Guidance: NA applies if surfaces with differing
etch rates are not processed together.
Only applies to joined assemblies which require etching as an
assembly.
3.5.5.5 When performing local etching, is used etch solution discarded? YES NO NA
Compliance Assessment Guidance: NA applies if local etching is not in
the scope of the audit, or the used etch solution is taken from, and
returned to, an etch immersion tank.
3.5.5.6 When performing local etching, is fresh solution kept in contact with the YES NO NA
metal surface for the required amount of time?
Nadcap AC7108/2 Revision G - 24 -
<Comment Box>
4.1.2 The Auditee’s written procedure for qualifying and certifying Etch
Inspection personnel shall address, or provide traceability to, the
following:
Compliance Assessment Guidance: Customers with more restrictive
requirements would issue supplemental Audit Criteria. Subscribers
have agreed that a supplemental Audit Criteria may be required to
address more restrictive requirements.
4.1.2.2 Formal training requirements for personnel shall be two hours minimum YES NO
for each Etch Inspection method performed?
4.1.2.5 Practical exams for programs that comply to SAE ARP1923 use at least YES NO NA
three (3) specimens representative of actual etched products?
Compliance Assessment Guidance: NA applies only if program is to
comply with NAS410/EN4179. For Anodic Etch and Blue Etch, if the
test parts do not have defects then suitable photographic images with
defects are required.
4.1.2.6 Practical exams for programs that do comply to NAS410/EN4179 use YES NO NA
at least two (2) test specimens representative of actual etched products
containing known indications?
Compliance Assessment Guidance: NA applies only if program is to
comply with SAE ARP1923.
For Anodic Etch and Blue Etch, if the test parts do not have defects
then suitable photographic images with defects are required.
4.1.2.7 The requirement that the candidates have to achieve a passing grade YES NO
of 70% or greater for the Anodic Etch, Blue Etch Anodize and Macro
Etch exam, 80% or greater for the Temper (Nital) Etch exam, and have
to detect all discontinuities, flaws or conditions specified by the
examiner in the applicable practical exams?
4.1.2.9 The requirement that the inspection personnel can distinguish and YES NO
differentiate between the colors/contrast used in the method for which
certification is sought?
Compliance Assessment Guidance: Any limitations in color/contrast
perception shall be evaluated by the individual responsible for the
process or the Responsible Level 3 prior to certification and must be
approved in writing.
4.1.2.10 The requirement that the tests shall be administered by trained YES NO
personnel designated by the Responsible Level 3, or the exam is
performed by a medically qualified individual?
Compliance Assessment Guidance: To clarify when a designation letter
is needed by the Responsible Level 3 to identify and approve those
who are not medically qualified with a statement that they have been
trained in accordance with NAS410/EN4179 versus those who are
medically qualified and do not need to have a letter.
Nadcap AC7108/2 Revision G - 26 -
4.1.2.11 The requirement that all records associated with training and YES NO
certification be maintained?
4.1.2.12 The re-examination requirements for personnel not meeting / failing YES NO
qualification criteria?
Compliance Assessment Guidance: Re-examination is required after
additional documented training in the area/s found to be deficient, 25%
new questions on the new exam.
4.1.2.13 Evidence that Etch Inspection personnel were requalified and/or YES NO
recertified in accordance with the written practice?
4.1.3.1 Were examiners and personnel who administered exams certified for YES NO
the method to which the exam applied?
4.1.3.3 Where NAS410/EN4179 are not the controlling specifications, does the YES NO NA
practical exam have at least three (3) test specimens representative of
actual etched products?
Compliance Assessment Guidance: NA applies only if program is to
comply with NAS410/EN4179
4.1.3.4 Where NAS410/EN4179 are the controlling specifications, does the YES NO NA
practical exam have at least two (2) test specimens representative of
actual etched products containing known indications?
Compliance Assessment Guidance: NA applies only if program does
not need to comply with NAS410/EN4179.
4.1.3.5 Did the candidates achieve a passing grade of 70% or greater for the YES NO
Anodic Etch, Blue Etch Anodize and Macro Etch exam, 80% or greater
for the Temper (Nital) Etch exam, and did they detect all discontinuities,
flaws or conditions specified by the examiner in the applicable practical
exams?
4.1.3.6 Did the candidates achieve an average score of no less than 80%? YES NO
Compliance Assessment Guidance: The average score is determined
by adding the results of the written exam(s) and the practical exam then
dividing by the number of exams given.
4.1.3.7 Is there evidence that personnel who did not pass the written exam(s) YES NO NA
and/or practical exam; received additional documented training or
completed self-study before repeating the applicable exam?
Nadcap AC7108/2 Revision G - 27 -
4.1.4.1 Do the Auditee’s certification records for all Etch Inspection personnel
include the following:
4.1.4.1.1 Date of qualification for each Etch Inspection method performed? YES NO
4.1.4.1.2 A minimum of two hours formal training for each Etch Inspection YES NO
method performed?
4.1.4.1.3 A minimum of twenty hours on-the-job training for each Etch Inspection YES NO
method performed?
4.1.4.1.4 Results of physical test; i.e., Tumbling E in accordance with ISO 18490, YES NO
20/25 (Snellen) at 16 inches (40.64cm), +/- 1 inch (2.54cm)*, or Jaeger
No 1 at not less than 12 inches (30.48 cm)*, in at least one eye either
natural or corrected?
4.1.4.1.5 Vision examination records indicating they can distinguish and YES NO
differentiate between the colors/contrast used in each Etch Inspection
method performed?
4.1.4.1.6 Evidence that the vision tests were administered by a trained individual, YES NO
or medically qualified individual?
4.1.4.1.7 Requalification and/or recertification for each Etch Inspection method YES NO NA
performed in accordance with written practice and the referenced
customer specifications?
Compliance Assessment Guidance: NA applies if there have been no
requalification or certification exams. Personnel responsible for
processing may be qualified only.
4.2.1 Is the calibration of the light meter performed at least semi-annually or, YES NO
with adequate documentation, extended as allowed by the governing
standard but not to exceed 12 months when 4 consecutive acceptable
calibrations and adequate documentation is available to support the
extended frequency?
4.2.3 Is the light meter accurate to within ± 5% of the standard reading? YES NO
Compliance Assessment Guidance: Note that the value of ±5% is in
reference to a comparison of the light meter being calibrated to another
calibrated (traceable to NIST or other National Standard) light meter. It
is not meant to represent a “true” ±5% calibration tolerance.
4.3.1 Is 100 ft-candles/1000 lux of white light, or more, available at the part YES NO
surface for visual verification of indications?
4.3.2 Is the check of the white light intensity being performed at least weekly YES NO
or prior to use, and after equipment maintenance?
4.3.3 Did the facility properly demonstrate and record this check? YES NO
4.4.1 Is 100 ft-candles/1000 lux of white light, or more, available at the part YES NO
surface for visual verification of indications?
4.4.2 Is the check of the white light intensity being performed at least weekly YES NO
or prior to use, and after equipment maintenance?
4.4.3 Did the facility properly demonstrate and record this check? YES NO
4.5.1 Is 100 ft-candles/1000 lux of white light, or more, available at the part YES NO
surface for visual verification of indications?
4.5.2 Is the check of the white light intensity being performed at least weekly YES NO
or prior to use, and after equipment maintenance?
4.5.3 Did the facility properly demonstrate and record this check? YES NO
4.6.1 Is 100 ft-candles/1000 lux of white light, or more, available at the part YES NO
surface for visual verification of indications?
4.6.2 Is the check of the white light intensity being performed at least weekly YES NO
or prior to use, and after equipment maintenance?
4.6.3 Did the facility properly demonstrate and record this check? YES NO
5. COMPLIANCE JOB 1
a. In-Process
b. Historic
5.2.3 Is the part controlled under U.S. Export Control Regulations as YES NO
declared by the Auditee?
Compliance Assessment Guidance: A NO answer does not require an
NCR
5.2.13 (EC) Other Purchase Order Requirements and any approved deviations
to specification requirements.<Comment Box>
Nadcap AC7108/2 Revision G - 33 -
5.3.1.1 Are part numbers, specifications, and revision levels flowed down YES NO
correctly?
5.3.1.2 Are frozen processes identified and if so, has customer approval been YES NO NA
obtained?
Compliance Assessment Guidance: NA applies if not a frozen process.
5.3.1.4 Does the shop paper provide traceable part identification? YES NO
5.3.2.1 Was receiving inspection correctly carried out as defined by shop YES NO NA
papers?
Compliance Assessment Guidance: NA applies if parts transferred
between departments and receipt inspection is not required.
5.3.2.2 Was pre-process cleaning carried out as defined by shop papers? YES NO NA
Compliance Assessment Guidance: NA applies if this step is not
required.
5.3.2.4 Are fixtures and masking designed to assure part area to be processed YES NO NA
is exposed and all other areas precluded as required by the customer?
Compliance Assessment Guidance: NA applies if masking was not
required.
Particular attention should be given to threaded holes, fayed surfaces
and joints of assemblies prior to welding or brazing, and assemblies
such as bearing raceways.
Nadcap AC7108/2 Revision G - 34 -
5.3.2.5 Was the part racked and fixtured as defined by shop papers? YES NO
5.3.2.6 Are fixtures, workbars, electrical connections, and hard masking free of YES NO NA
corrosion and physical damage detrimental to the process while in use?
Compliance Assessment Guidance: NA applies for processes that do
not use these devices.
5.3.2.7 Was cleaning, e.g. alkaline cleaning and cleanliness verification, carried YES NO
out as defined by shop papers?
5.3.2.9 Was a water break free surface observed after the cleaning cycle? YES NO NA
Compliance Assessment Guidance: NA applies only for barrel and/or
automated lines unless the specification specifically requires a water
break free test.
Unless the specification defines when the water break free test is done
it may be done after cleaning or after deoxidation.
5.3.2.10 Were the etching steps carried out as defined by shop papers? YES NO
5.3.2.13 After etching, are the etched and previously masked surfaces (if any) YES NO
thoroughly rinsed to remove any remaining etchant?
5.3.2.14 Are parts promptly and thoroughly rinsed after etch so as to preclude YES NO
local over-etching?
Compliance Assessment Guidance: Local over etching can be seen as
metallic streaks running down the part surfaces.
5.3.2.15 Were any post main process steps (e.g. de-smut) carried out as defined YES NO NA
by shop papers?
Compliance Assessment Guidance: NA applies if this step is not
required.
5.3.2.16 Was post process de-masking and cleaning carried out as defined by YES NO NA
shop papers?
Compliance Assessment Guidance: NA applies if this step is not
required.
Nadcap AC7108/2 Revision G - 35 -
5.3.2.17 Were post-processing thermal and forced drying treatments carried out YES NO NA
as defined in shop papers?
Compliance Assessment Guidance: NA applies if this step is not
required.
5.3.3 Are all process parameters defined in AC7108 App D recorded and YES NO NA
traceable to the route card/traveler?
Compliance Assessment Guidance: NA applies if the design authority
has specifically stated that the process parameters need not be
recorded.
5.3.5 Are all operations done in sequence recorded or traceable to specific YES NO
process lines/workstations, operator/technician?
5.3.7 Are all process control and process monitoring/recording equipment YES NO
calibrated?
<Comment Box>
5.3.10 Are all operations properly stamped off or signed off and dated, as YES NO
required, by the correct operator or department?
5.4.4 Was inspection carried out under the correct light intensity? YES NO
5.4.7 Were all inspection results properly recorded and traceable to the YES NO
parts?
5.4.9 Was part protection and packing per defined requirements? YES NO NA
Compliance Assessment Guidance: NA applies if parts are moved
within the same facility.