38YRA

030-042 Series 1
208/230-1-60

Wiring Diagram

CONNECTION DIAGRAM SCHEMATIC DIAGRAM


L1 DSV (LADDER FORM)
RED or BLK RED
DSV
COMP
*CH BLK CONT R
COMP BLU BLU C L2
RED or BLK RED BLK BLK S CAP 11 21
L1 BLK C S
208/230 1Ø 11 21 R YEL 5 2 *SC
POWER L2 YEL
BRN 1 H
SUPPLY 23 23 YEL *SC EQUIP CONT
EQUIP *SR
GND OFM GND
CONT 1 2 *CH C
BRN 23 23
BLK 5 OFM
YEL DR F
BLK *SR
CAP
YEL
BRN OF1 OF2
*LPS *DTS *HPS RVS
BLK BLU BLU or YEL C
YEL BLK
YEL BLU or YEL O O DR
DR 90 W2
50
OF1 30
R R
TEST
C DFT
BRN DFT
C
LOGIC
DFT LOGIC
OF2
T1 Y Y

T2
YEL DR
CTD
CTD T1 T2 C
LOGIC Y RVS
C Y O W2 R O BLK BLK
or or *LPS *DTS *HPS LOGIC CONT
R ORN
ORN C
CB YEL WHT BLK BLK
BLK ORN RED or or
PNK PNK
DFT
C Y O W2 R E L W3 G INDOOR UNIT
TERMINAL BLOCK
NOTE
THIS DEFROST CONTROL BOARD CONTAINS A FIVE MINUTE
C Y O W2 R E L G SHORT CYCLE PROTECTOR. A FIVE MINUTE DELAY WILL
INDOOR THERMOSTAT (NOTE #5)
OCCUR BETWEEN COMPRESSOR OFF/ON CYCLES.

90
50 FIELD SELECTED TIME PERIOD NOTES:
BETWEEN DEFROST CYCLES (MINUTES) 1. COMPRESSOR AND FAN MOTOR
30 FURNISHED WITH INHERENT THERMAL
PROTECTION.
TEST JUMPERED TEST PINS (USE METAL OBJECT), FIELD SPEED-UP CYCLE 2. TO BE WIRED IN ACCORDANCE WITH
HEAT CYCLE: 90 MIN. ACCELERATED TO 21 SEC. NATIONAL ELECTRIC CODE (N.E.C.) AND
50 MIN. ACCELERATED TO 12 SEC. LOCAL CODES.
30 MIN. ACCELERATED TO 7 SEC. 3. N.E.C. CLASS 2, 24 V CIRCUIT,
DEFROST CYCLE: 10 MIN. ACCELERATED TO 2 SEC. MIN. 40 VA REQUIRED.
4. USE COPPER CONDUCTORS ONLY FROM
-LEGEND- DISCONNECT TO UNIT.
5. MUST USE THERMOSTAT AND SUB-BASE
FACTORY POWER WIRING AS STATED IN PRE-SALE LITERATURE.
COMP COMPRESSOR 6. IF INDOOR SECTION HAS A TRANSFORMER
FIELD POWER WIRING CTD COMPRESSOR TIME DELAY WITH A GROUNDED SECONDARY,
FACTORY CONTROL WIRING CONT CONTACTOR CONNECT THE GROUNDED SIDE TO "C"
FIELD CONTROL WIRING CB CIRCUIT BOARD ON THE CIRCUIT BOARD.
DFT DEFROST THERMOSTAT 7. IF ANY OF THE ORIGINAL WIRE, AS
CONDUCTOR ON CIRCUIT BOARD
DR DEFROST RELAY AND CIRCUITRY SUPPLIED, MUST BE REPLACED, USE THE
COMPONENT CONNECTION SAME OR EQUIVALENT WIRE.
DSV DISCH. SOLENOID VALVE (WHEN USED)
1/4-INCH QUICK CONNECT 8. CHECK ALL ELECTRICAL CONNECTIONS
*DTS DISCHARGE TEMP. SWITCH
INSIDE CONTROL BOX FOR TIGHTNESS.
TERMINALS *HPS HIGH PRESSURE SWITCH
9. DO NOT ATTEMPT TO OPERATE UNIT
FIELD SPLICE *LPS LOW PRESSURE SWITCH UNTIL SERVICE VALVES HAVE BEEN
JUNCTION OFM OUTDOOR FAN MOTOR OPENED.
RVS REVERSING VALVE SOLENOID 10. WHEN DTS, LPS AND HPS ARE NOT
CAP CAPACITOR (DUAL RUN)
*SC START CAPACITOR REQUIRED, A JUMPER WILL BE INSTALLED
*CH CRANKCASE HEATER *SR START RELAY BETWEEN Y AND T1 ON THE DEFROST
BOARD.
* MAY BE FACTORY OR FIELD INSTALLED 320506-401 REV. E

A93424
Fig. 1—38YRA030-042 208/230v, 1 Phase, 60 Hertz

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1 4 PC 101 Catalog No. 533-831 Printed in U.S.A. Form 38YRA-2W Pg 1 5-94 Replaces: New
Tab 5a 5a
Copyright 1994 CARRIER Corp. • 7310 W. Morris St. • Indianapolis, IN 46231 43031c

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1 4 PC 101 Catalog No. 533-831 Printed in U.S.A. Form 38YRA-2W Pg 2 5-94 Replaces: New