You are on page 1of 2

TECTUM® Create!


Direct-Attach
Standard & Custom Ceiling Panels
coarse texture

CAD/Revit® drawings at:


armstrongceilings.com

Tectum®
Direct-Attach
Panel

1X Furring
Strips
24" O.C. or
Equal Laid On 3/4"
Furring Strips

23.75" 23.75"

47.75" 47.75"
48" 48"

5334W2L04T10CXWA 5334W2L04T10CXWB
2' x 4' Steady Wave 2' x 4' Steady Wave
Panel A Panel B
23.75" 23.75" 96" A
96" B C D A B C

A B C D A B
48" 48"
1" thick Tectum Create! Direct-Attach 47-3/4" x 96" ceiling and wall panels in standard Rustic Plank design

5334W4L08T10CXWA A 5334W4L08T10CXWA
B C D A B
Transform interior spaces with distinctive image depth and personality on5334W2L04T10CXWC
texture-rich Tectum5334W2L04T10CXWD
® Create!™ Direct-Attach ceilings
4' x 8' Steady panels. 4' x 8' Steady Wave
Wave
2' x 4' Steady Wave 2' x 4' Steady Wave Panel A Panel B
Panel C Panel D
KEY SELECTION ATTRIBUTES 23.75" 23.75" Steady Wave 23-3/4" x 48" Steady Wave 47-3/4"
A B x 96"
C D A B
95" 95.5"
• Now, 1" thick Tectum Create! Direct-Attach • Great retrofit solution for

panels are available in four standard designs, noise reduction


or submit your own custom artwork • CleanAssure

family of 47.75"
products –
48" 48" 47.75"
• Repeat panel patterns can span surfaces includes disinfectable panels, 48" 2' x 4' Steady Wave Pattern Repeat
in both vertical and horizontal directions suspension systems, and trim
• Excellent sound absorption – NRC up • Tectum panels are part of
® 96"
to 0.85 (mounting method dependent)
5334W2L04T10CXWA the Sustain® portfolio and meet
5334W2L04T10CXWB
• Panel sizes include 23-3/4" x 48" 2' x 4' Steady Wave 2'the most
x 4' stringent
Steady Waveindustry
Panel A
and 47-3/4" x 96" with long and short beveled sustainability
Panel B compliance 2' x 4' Steady Wave Pattern Size
23.75"
edges (No additional custom sizes available)
23.75"
standards today 96" 96" A B C D A B C

• Create your one-of-a-kind


• Panels can be directly attached to a wide variety

of interior surfaces acoustic artwork! To get 4' x 8' Steady Wave Pattern Size
48"
started,
48"
contact A B C D A B
ASQuote@armstrongceilings.com A B A B A
STANDARD DESIGNS
A B C D A B
Multiple panels are used to create5334W2L04T10CXWC
full patterns. 5334W4L08T10CXWA 5334W4L08T10CXWA
5334W2L04T10CXWD 4' x 8' Steady Wave 4' x 8' Steady Wave
2' x 4' Steady Wave 2' x 4' Steady Wave Panel A Panel B A B A B
Panel C Panel D
A B C D A B
95" 95.5"

Textured Hex Exposed Brick Rustic Plank Steady Wave


(CXH) (CXB) 48"
(CXP) (CXW) A B A B
2' x 4' Steady Wave Pattern Repeat

DETAILS 96"

1. Rustic Plank design on multiple Tectum Create! Direct-Attach panels viewed from greater than 5' 4' x 8' Steady Wave Pattern Repeat
2' x 4'
2. Steady
Close-upWave Pattern
of Rustic PlankSize
Tectum Create! image from Detail 1
NOTE: For optimal visual, product is best viewed at a distance with direct lighting. Panel face and bevel
are printed, while vertical edges are painted white. Custom solid color edge painting is available
1 2 upon request. 4' x 8' Steady Wave Pattern Size

TechLine 877 276-7876


armstrongceilings.com/tectumcreate
®
WELL LEED
LBC
For LEED contribution visit

®
TECTUM Create!
armstrongceilings.com/greengenie

LEED
® ™


Direct-Attach

producer resp.

raw materials

low emitting/
management
construction
waste mgmt

sourcing of
recyclable/

(for wood)

ingredient
design for

acoustics
materials

materials

materials
extended

reporting
Standard & Custom Ceiling Panels

biobased
flexibility

recycled

material
regional

content

lighting
energy

quality
FSC ®
EPD
coarse texture ▲
LOCATION DEPENDENT

Dots represent high


VISUAL SELECTION PERFORMANCE level of performance. ACOUSTICAL INFORMATION
Bio- Humi- CleanAssure™ DURABILITY
Block Guard+ Disinfectable Panels

Panel Mounting

Anti-Mold/
Thickness Methods

Mildew

Impact
Rating

Resist
Dimensions

Sag
Fire

Fog
Nominal 1" 0.40 A
Item WxLxH 0.45 D-20
No. ◆ (Inches)
0.80 C-20
TECTUM Create!
® ™5334W2L04T10_ _ _ _ 23-3/4 x 48 x 1" Class A • • • •

Direct-Attach 0.85 C-40
Standard Ceiling Panels •

Long Edges
5334W4L08T10_ _ _ _ 47-3/4 x 96 x 1" Class A • • • •
Beveled/
Short Edges
Beveled*
* Printed image will continue on beveled edge. Vertical edge of panel will be painted Tectum White (TWH) unless specified otherwise.
◆ When specifying or ordering, include the appropriate 3-digit design suffix (CXH = Textured Hex, CXB = Exposed Brick, CXP = Rustic Plank,
CXW = Steady Wave) and panel identifier = A-D (e.g. 5334W2L04T10 C X B C )

Tailor Designs with Custom Tectum Create! Ceiling Panels


Create beautiful, unique spaces with printed imagery on Direct-Attach ceiling panels

Higher resolution files will have best results. The rich texture of the panels enhances images with high contrast, and appears almost three-dimensional when viewed from greater than 5'.
Raster Images: Digital photographs should be created Vector Graphics: Logos and illustrations should
in a raster based program such as Adobe® Photoshop®. be created in a vector-based program such as
Image must be 150 dpi at full print size
•  Adobe® Illustrator®.
• Acceptable file types:
Acceptable file types:
• 
- Encapsulated PostScript – .eps * Armstrong will not be held liable for
- Joint Photographic Experts Group – .jpg artwork color variances from computer
- Tagged Image File Format – .tiff - Scalable Vector Graphics – .svg screen to completed project, or between
•  Acceptable color mode: CMYK runs of similar material.
• Acceptable color mode: RGB

ACOUSTICAL MOUNTING METHODS

DIRECT-TO-STRUCTURE – Standard
Based on desired final aesthetic, installer may want to field-color screw heads using permanent markers (by others) to coordinate with image colors.
Mounting A Mounting D-20 Mounting C-20 Mounting C-40

Tectum® Tectum®
Tectum® Direct-Attach
Direct-Attach Direct-Attach
Tectum® Panel
Direct-Attach Panel Panel
1X Furring 2X Furring
Panel Strips Laid on 1-1/2"
1X Furring Strips Laid on 3/4"
24" O.C. Furring Strips 24" O.C. Furring Strips
Strips
Or Equal With 1", 3 lb. Or Equal With 2-1/2"
24" O.C. Laid On 3/4"
Or Equal Density Fiberglass Batt Insulation
Furring Strips

PHYSICAL DATA Installation Considerations Application Considerations


The face and bevels of the panel are printed. Vertical edges of the Color variation among panels is common due to the natural
Material panel are painted Tectum White (TWH). Custom solid colors may be characteristics of the wood.
Cementitious Wood Fiber available upon specification. Tectum Create! is not for use in exterior spaces.
Surface Finish Viewing angles and direct light will impact the viewing surface. The rich texture of the panels enhances images with high contrast, and
Factory-applied latex paint with powerful LED curing The surface has a great deal of texture and results may vary. appear almost three-dimensional when viewed from greater than 5'.
technology. Primary (Embodied) Energy Cleaning and Disinfecting
Fire Performance See all LCA information on our EPDs. Cleaning and CDC recommended disinfecting options
Class A. Flame Spread Index 25 or less and Smoke Developed Design Considerations available on armstrongceilings.com/cleaning
Index 50 or less when tested in accordance with ASTM E84. For touch-up solutions, use colored permanent markers to touch-up Seismic Restraint
Humidity/Sag Resistance any defects on the board or to blend white or unfinished screw Tectum Direct-Attach panels are approved for application
HumiGuard® Plus performance panels are recommended faces. in all seismic areas when installed per the seismic guidelines
for areas subject to high humidity, up to, but not including, For each design, the standard order quantity is 128 square feet: in the Armstrong Ceilings & Walls Installation Instructions.
standing water and outdoor applications. four 2 x 4' panels or two 4 x 8' panels. Panels may be ordered Weight, Pcs and SF/Pallet
Anti-Mold/Mildew individually, however a minimum order quantity fee applies to any 1" – 1.65 lbs/SF
Ceiling panels with BioBlock® performance resist the growth order under 128 square feet.
of mold and mildew on the panel surface. For optimal visual, product is best viewed at a distance.
Imagery with linear patterns may not align perfectly, panel to panel.

LEED® is a registered trademark of the U.S. Green Building Council; Declare® and Living Building Challenge™ (LBC) are
TechLine / 1 877 276-7876 trademarks of the International Living Future InstituteSM; WELL™ and WELL Building Standard™ are trademarks of the International
armstrongceilings.com/tectumcreate WELL Building Institute; Adobe®, Illustrator®, and Photoshop® are trademarks of Adobe in the United States and/or other countries;
Revit® is a registered trademark of Autodesk, Inc.; UL and UL Certified are registered trademarks of UL LLC; all other
BPCS-6600-821 trademarks used herein are the property of AWI Licensing LLC and/or its affiliates © 2021 AWI Licensing LLC

You might also like