VACUTAP® VR® (Next Generation) Flyer IN5062036 03 en
VACUTAP® VR® (Next Generation) Flyer IN5062036 03 en
MAXIMUM PERFORMANCE.
MAXIMALLY TESTED.
W WW.R EIN HAU S E N.COM
VACUTAP ® VR ®
Several tenthousand VACUTAP® VR® units are currently Reliable. Rugged. Economical.
demonstrating their value for our customers around
the world. Our engineers incorporated this one-of-a-kind These three traits are the essence of our VACUTAP®
operating experience into the development of the technology. And the VACUTAP® VR® takes advantage of the
VACUTAP® VR®. The result is sure to impress: Optimization enormous versatility offered by this technology. It is ideal
of the design allowed us to increase the permitted values for all operating applications:
for step voltage and switching capacity once again.
I Grid
The combination with the R-selector provides additional I Electric arc furnace
advantages. The R-selector displays these advantages I HVDC
through the significantly increased tap-changing capacity I Variable shunt reactors
of the change-over selector and higher permissible I Phase shifters
operating and testing voltages. This means that higher
power requirements are ideal for taking full advantage of In terms of economy, the VACUTAP® VR® makes no
the strengths of this combination. In addition, the Active compromises, enabling 300,000 tap change operations
Gas Inhibition System®* can be used to reduce gas gene- with-out any maintenance. The diverter switch insert
ration in the transformer tank caused by tap selector can be used for 1.2 million tap changes before needing
operations by up to 90 percent. replacement.
3
VACUTAP ® VR ®
4
VACUTAP® VR® WITH R-SELECTOR* -
A FUTURE-DEFINING COMBINATION.
The R-selector and the VACUTAP® VR® are an unbeatable team for high
power capacities. The generation of selectors features more than just
an increased switching capacity of the change-over selector.
The R-selector combines high economy with maximum durability.
Optimized handling
Customer requests were consistently implemented in the design of the
R-selector. This made it possible to improve the handling significantly.
This enables shorter lead times for transformer manufacturers and ultimately
reduces costs. Lifting the selector to the diverter switch oil compartment
(using a forklift or scissors lift) is also made easier, since the bottoms of the
tap selectors and change-over selectors are on the same level. This means
improved handling as well as increased work safety when connecting to the
diverter switch. Selector take-off leads on the interior side and the resulting
simplification of the cable routing guarantee more space and flexibility for
the connecting leads. The contacts are also more accessible and provide a
larger connection surface.
*
VACUTAP® Ir Phases Selector
VRS®/VRM®/VRL®/VRH® 700...1300 A I + II + III R-selector up to 6 levels
1600 A III (Y) E-selector with 6 levels
1600 A I
VRL® R-selector with 4 levels
1800...2400 A I
2401...3200 A I R-selector with 6 levels
VACUTAP® VR® –
TECHNICAL DATA.
VRM I 26221)
VRS III 700 Y
VRM II 1002
VRM II 1302
VRS I 26221)
VRM I 1001
VRM I 1301
VRS II 1002
VRS II 1302
VRM II 702
VRS I 1001
VRS I 1301
VRM I 701
VRS II 702
VRS I 701
Designation
Max. rated through-current I r (A) 700 1000 1300 2600 700 1000 1300 2600
Max. rated step voltage U ir (V) 4500 4500 4500 4500 4500 4500 4500 4500
VRH II 13022)
VRS III 700 Y
VRM II 1002
VRM II 1302
VRH II 6522)
VRS II 1002
VRS II 1302
VRL II 1302
VRM II 702
VRS II 702
Designation
Highest voltage for equipment
72,5 123 170 245 72,5 123 170 245 300 362
Um (kV)
Rated lightning impulse withstand
350 550 750 1050 350 550 750 1050 1050 1175
voltage (kV, 1.2|50 µs)
Rated short-duration power frequency
140 230 325 460 140 230 325 460 460 510
withstand voltage (kV, 50 Hz, 1 min.)
1)
Forced current splitting by two parallel winding branches required. Not for electrical arc furnace operation.
2)
Special applications on request
6
VACUTAP ® VRL® I / II / III VACUTAP ® VRH ® / VRX® I / II / III 3)
VRL III 1600 Y4)
VRH I 26221)
VRL I 16014)
VRL I 26221)
VRH II 1302
VRL II 1302
VRH I 1301
VRX I 1302
VRL I 1301
VRL I 1801
VRL I 2001
VRL I 2401
VRL I 2601
VRL I 3001
VRL I 3201
VRH II 652
VRH I 651
VRX I 652
1300 1600 1800 2000 2400 2600 3000 3200 650 1300 2600 650 1300
16 16 19 24 24 25/26 30 32 10 16 26 10 16
3 3 3 3 3 3 3 3 3 3 3 3 3
40 40 47,5 60 60 65 75 80 25 40 65 25 40
6000
4500 4500 6000 6000 6000 6000 6000 6000 6000 6000 120002) 120002)
4500
48002)3) 10000
5850 10000 10000 10000 10000 10000 3000 6000 12000 6000 12000
6000 2) 11700
50...60 50...60
without change-over selector: max. 18, without change-over selector: max. 18,
with change-over selector: max. 35 with change-over selector: max. 35
ETOS® ETOS®
VRH I 26221) 2)
26221) 2)
26221)
32 012)
VRH I 13012)
VRX I 13022)
26221)
26012)
30012)
1001
1301
VRH I 6512)
VRX I 6522)
1001
1301
1301
1601
1801
2001
2401
701
701
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
VRM
VRM
VRM
VRM
VRS
VRS
VRS
VRS
VRL
VRL
VRL
VRL
VRL
VRL
VRL
VRL
VRL
7
8
Rated step voltage Uir [V] Rated step voltage Uir [V]
VACUTAP ® VR ®
0
500
1000
1500
2000
2500
3000
3500
4000
0
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
5500
6000
6500
0
100
100
200
200
300
300
1500 kVA
400
400
VRH I 651*
VRH II 652*
VRH III 650Y*
500
500
600
VRS I 701 VRM I 701
Step capacity diagram for VR® grid
600
2100 kVA
VRS II 702 VRM II 702 VRS I 701 VRM I 701
2100 kVA
VRS III 700Y VRM III 700Y VRS II 702 VRM II 702
VRS III 700Y VRM III 700Y
700
700
Existing range
Existing range
3000 kVA
1000
4800 kVA
VRS I 1301 VRM I 1301 VRL I 1301 VRS I 1301 VRM I 1301 VRL I 1301
VRS II 1302 VRM II 1302 VRL II 1302 VRS II 1302 VRM II 1302 VRL II 1302
6000 kVA
VRS III 1300Y VRM III 1300Y VRL III 1300Y VRS III 1300Y VRM III 1300Y VRL III 1300Y
VACUTAP® VR® – TECHNICAL DATA.
1300
1300
1400
1400
VRL I 1601
VRL III 1600Y
1600
VRL I 3001
VRL I 2001
VRL I 2601
VRL I 2401
VRL I 3201
VRL I 1801
Performance upgrade
6000 kVA
*) I r > 2400 A on request
VRL I 3201*
VRL I 2001
VRL I 2401
VRL I 1801
Performance upgrade
9
VACUTAP ® VR ®
VACUTAP® VR® –
TECHNICAL DATA.
Grid with forced current splitting VR®
step capacity diagram
6500
6000
12000 kVA
VRH I 2622*
5500
5000
4500
Rated step voltage Uir [V]
10000
9000
Rated step voltage Uir [V]
8000
7000
6000
5000
4000
3000
2000
1000
0
0 50 100 150 200 250 300 350 400 450 500 550 600 650
Rated through-current Ir [A]
11
Maschinenfabrik Reinhausen GmbH
Falkensteinstrasse 8
93059 Regensburg, Germany