DIVISION 33 UTILITIES KEMPTOWN COMMUNITY PARK REHABILITATION PROIECT SECTION 33 40 00 - STORM DRAINAGE PART | - GENERAL 1 A 16 RELATED DOCUMENTS Drawings and general provisions ofthe Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this Section, SUMMARY ‘This Section includes storm drainage outside the building. DEFINITIONS: PE: Polyethylene plastic. PVC: Polyvinyl chloride plastic RCCP: Reinforced circular conerete pipe, PERFORMANCE REQUIREMENTS (SECTION NOT USED) SUBMITTALS Shop Drawings: Include plans, elevations details, and attachments for the following: 1, Precast concrete manholes and other steuctures, including frames, covers, and arate. 2. Castin-place concrete manholes and other structures, including frames, covers, and grates. 3, Polyethylene manholes and drains, including frames covers and grates. Coordination Drawings: Show manholes and other structures, pipe sizes, locations, and elevations. Include details of underground structures and connections. Show other Piping in same trench and clearances from sewerage system piping. Indicate interface ‘and spatial relationship between piping and proximate structures. Design Mix Reports and Calculations: For each class of east-in-place concrete. Field Test Reports: Indicate and interpret test results for compliance with performance requirements DELIVERY, STORAGE, AND HANDLING STORM DRAINAGE, 334000-1 7 KEMPTOWN COMMUNITY PARK REHABILITATION PROJECT Do not store plastic structures, pipe, and fitings in dret sunlight Protect pipe pipe fitings, and seals frm dir and damage. Handle precas concrete manholes and other sricures according to manufacturer's wien sigging instructions PROIECT CONDITIONS Site Information: Perform site survey, research public utility records, and. verify ‘existing ullty locations, Locate existing structures and piping to be closed and abandoned. Existing Utilities: Do not interupt utilities serving facilities occupied by Owner o ‘others unless permitted under the following conditions and then only after arranging to provide temporary uly services according to requirements indicated 1, Notify Engineer not less than two days in advance of proposed ut interruptions. PART 2 - PRODUCTS 2u A 22 PIPING MATERIALS Refer to Part3 "Piping Applications" Antcle for applications of pipe and fiting ‘materials. PIPES AND FITTINGS ‘Corrugated PE: Drainage Tubing and Fittings: AASHTO M 252, Type S, with smooth ‘waterway for coupling joints. |. Siltight Couplings: PE sleeve with ASTM D 1056, Type2, Class A, Grade 2 ‘gasket material that mates with tube and fittings to form siltight joints. ‘Corrugated PE Pipe and Fittings: AASHTO M 294, Type S, with smooth waterway for coupling joints. Siltight Couplings: PE sleeve with ASTM D 1056, Type 2, Class A, Grade 2 gasket material that mates with pipe and fittings to form sitight joints. PVC Sewer Pipe and Fittings: According othe followin 1. PVC Sewer Pipe and Fittings, NPS 15 (DN375) and Smaller: ASTM D 3034, SDR 35, for solvent-cemented or gasketed joints, ‘STORM DRAINAGE 33.4000-2 23 24 25 KEMPTOWN COMMUNITY PARK REHABILITATION PROJECT a. Gaskels: ASTMF 477, elastomeric seals 2, PVC Sewer Pipe and Fittings, NPS 18 (DN4S0) and Larger: ASTM F 679, T-1 ‘wall thickness, bell and spigot for gasketed joints, a Gaskets: ASTM F 477, elastomer seals. Reinforeed-Conerete Sewer Pipe and Fittings: ASTM C 76 (ASTM C 76M), Ciass 1V, Wall B, for gasketed joints. 1. Gaskets: ASTM C 443 (ASTM C 443M), rubber. Reinforced Conerete Low-head Pressure for Principle Spillway L Pipe: ASTM C361 with watertight joints in size indicated on the plans. 2. Joints: Push-on with rubber gasket seal MANHOLES ‘Manholes, both precast and castin-place conerete, shall be constructed as per current ‘Maryland State Highway Administration standards. Manhole Frames and Covers: ASTM A536, Grade 60-40-18, ductile-iron castings designed for heavy-duty serviee, Include indented top design with lettering "STORM, SEWER” cast into cover CATCH BASINS Catch Basins, both precast and cast current Maryland State Highway Administration standards Prames and Grates: constructed as per current Maryland State Highway Adi standards, ‘STORMWATER INLETS Curb Inlets: Made with vertical curb opening, of materials and dimensions according to ccurtent Maryland State Highway Administration standards, Gutter Inlets: Made with horizontal gutter opening, of materials and according to Curent Maryland State Highway Administration standards, Include heavy-duty frames and grates. ‘Combination Inlets: Made with vertical curb and horizontal gutter openings, of ‘materials and dimensions according to current Maryland State Highway Administration standards.. Include heavy-duty frames and grates STORM DRAINAGE, 3340 00-3 | 26 KEMPTOWN COMMUNITY PARK REHABILITATION PROJECT Frames and Grates: Heavy-duty frames and grates according to current Maryland State Highway Administration standards Gray-lton Treach Drains: ASME A112.21.1M, G-inch- (150-mm-) wide top surface, rectangular body with anchor flange or other anchoring deviee, and rectangular, secured arate. Include units of total lengths indicated and number of bottom outlets with inside ‘alk or spigot connections, of sizes indicated. Use units with top-loading classifications according (othe following applications: 1. Exta-Heavy Duty: In roads, HS-25 loading STORMWATER DETENTION STRUCTURES, Castin-Place Concrete, Stormwater Detention Structures: Construct of reinforced- ‘concrete bottom, walls, and top; designed according to ASTM C 890 for A-I6, heavy- ttalfi, structural loading: of depth, shape, dimensions, and appurtenances indicated |. Ballast: Increase thickness of coneret, as required to prevent flotation 2 Steps: Manufactured ftom deformed, 1/2-inch (13-mm) steel reinforcement rod ‘complying with ASTM.A 615/A 615M and encased in polypropylene complying with ASTM D 4101. Include pattern designed to prevent lateral slippage off step. Cast or anchor into sidewalls with steps at 12-to 16-inch (300- to 400-mm) intervals. Omit steps for structures less than 60 inches (1500 mm) deep. Manhole Frames and Covers: ASIM A536, Grade 60-40-18, ductile-iron castings designed for heavy-duty service. Include indented top design with lettering "STORM. SEWER" cas into cover, Sand Filter: Materials shall comply with Maryland Stormwater Design Manual 1, Sand shall be clean AASHTO M-6 or ASTM C-33 concrete sand with the grain size between 0,02" and 0.04", Calcium carborated or dolomitie sand are not permitted, 2, Peat: reed-sedge hemic peat, shredded, uncompacted, uniform and clean, ash content: < 15% b. pel range: 5.21049 ©. loose bulk density 0.12 10 O.15 glee 3, Underdrain Gravel: AASHTO M-43, size between 0375" to 0.75" 4. Geotextile Fabric: ASTM D-4833, puncture strength 125 tb, 0.08” thick equivalent opening, Minimum 125 gpm per sq.ft. flow rate 5. Underdrain piping: AASHTO M-278, rigid schedule 40 PVC, 3/8” perforations @ 6° holes per row; minimum of 3 gravel over pipes 6, Conerete: MSHA Mix No, 3 7. Reinforcing Steel: ASTM 615-60 (grade 60) 8, Non-ebar steel: ASTM A-36, hot dipped galvanized ASTM A-123, STORM DRAINAGE 33.4000-4 27 KEMPTOWN COMMUNITY PARK REHABILITATION PROJECT CONCRETE. 1. General: Castin-place sitework concrete according to current Maryland State Highway Administration standards, PART 3- EXECUTION 34 A 32. A B c. EARTHWORK Excavating, trenching, and backfilling are specified in Division 31 "Earthwork", Section 3123 00 “Excavating and Backtilling” PIPING APPLICATIONS General; Include watertight, siltight, or soilkight joints, unless watertight or slight joints are indicated. Refer to Part 2 of this Section for detailed specifeations for pipe and fitting products listed below. Use pipe, fittings, and joining methods according to applications indicated, Gravity-Flow Piping: Use the following 1, NPS3 (DN80}:ABS, SDR 35, sewer pipe and fittings; solvent cemented joints; or gaskets and gasketed joints 2, NPS and NPS6 (DNIOO and DN150}: Corrugated PE drainage tubing, and fitting, soitight couplings, and coupled joints 3. NPS4 and NPS6 (DNIO0 and DN150): Corrugated PE drainage tubing and Fittings, sltight couplings, and coupled joins. 4, NPS and NPS 6 (DNI00 and DN130): Cellular-core PVC pipe, PVC sewer pipe fitings, and sotvent-cemented joints. 5. NPS4 and NPS 6 (DN100 and DN150): PVC sewer pipe and fitings, solvent. ‘cemented joints, or gaskets and gasketed joints. 6. NPS8 to NPS15 (DN200 to DN375): Corrugated PE drainage tuhing and fittings, soiltight couplings, and coupled joints in NPS 8 and NPS 10 (DN200 and DN250)._ Use comugated PE pipe and fitings, soiltight couplings, and coupled joints in NPS 12 and NPS 15 (DN300 aed DN375).. 7. NPS8 to NPS 15 (DN200 to DN375): Corrugated PE drainage tubing and fitings,siltipht couplings, and coupled joints in NPS 8 and NPS 10 (DN200 and DN2S0). Use corrugated PE. pipe and fittings, siltight couplings, and coupled joints in NPS 12 and NPS 15 (DN300 and DN375).. 8. NPS8 to NPS 15 (DN200 to DN375): PVC sewer pipe and fitings, solvent. ‘cemented joins, or gaskets and gasketed joins. 9, NPS 8 to NPS 15 (DN200 to DN375):_ NPS 12 and NPS 15 (DN300 and DN375) reinforeed-concrete sewer pipe and fitings, gaskets, and gasketed joints, Do not STORM DRAINAGE 33.40 00-5 33 34 © KEMPTOWN COMMUNITY PARK REHABILITATION PROJECT use nonteinforced pipe instead of reinforced conerete pipe in NPS 8 and NPS 10 (DN200 and DN2S0), INSTALLATION, GENERAL General Locations and Arrangements: Drawing plans and details indicate general location and arrangement of underground storm drainage piping. Location and arrangement of piping layout take design considerations into account. Install piping as indicated, to extent practical. Install piping beginning at low point, tue to grades and alignment indicated with unbroken continuity of invert. Pluce bell ends of piping facing upstream. Install ‘gaskets, seals, sleeves, and couplings according to manufacturer's writen instructions {or use of lubricants, cements, and other installation requirements. Maintain swab or

You might also like