You are on page 1of 68

Expansion Joint systems

MasterFormat™ Division: 7
800.222.5556 | inprocorp.com/jointmaster

INTERIOR AND EXTERIOR


ARCHITECTURAL PRODUCTS
Why JointMaster?

At JointMaster® we protect buildings from natural shifting and movement with expansion joint
systems engineered to handle every condition. We realize that different buildings have different
needs, so we have a team of experts on hand to help with your project specific conditions.

Obsessively Engineered
We constantly test and review our systems to create
designs engineered to meet your needs. Whether
it’s applying tapered plates for maximum durability
and longevity, noise dampening elements in
consideration of noise pollution or using recycled
tires as an eco-friendly option – we continuously
innovate to provide you with the best solutions.

We Protect Every Building


From stadiums to schools, pediatric
centers to parking garages, you
can count on us to provide the
movement protection that your
building requires.

Experienced Experts
Let us eliminate your toughest challenges so you
can focus on more important things like your
building’s design and construction. Consult our
team of experts about joint system selection and
installation methods. We will even come to your
office or site.

2 800.222.5556 | Installation Hotline: 866.ezinpro


Expansion Joint Systems

Owensboro Medical Health Center, Owensboro, Kentucky


601 Stealth

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 3


Floor Systems

Joint Movement
System Type Series Models Loading Class
Opening +/-
Surface Mount, Flush Mount – Pages 10-15
101
103-110 1"-3"
25%
100 Series 120 25mm – Standard
of Joint Width
132/133 75mm
141
Recessed Mount – Pages 16-17

221 2"-36"
25%-100% Standard
200 Series 222 50mm –
of Joint Width Moderate
223 900mm

Glide Plate – Pages 18-19


300
2"-6"
304 50%-100%
300 Series 50mm – Standard
312 of Joint Width
150mm
320
Centering Bar – Pages 20-23
401
421/423/425 1"-18" Standard
50%-100%
400 Series 426/427/428 25mm – Moderate
of Joint Width
430/432 450mm Heavy Duty
441/461/471
Heavy Duty – Pages 24-26
721/723/725
2"-12" Standard
741 50%-100%
700 Series 50mm – Moderate
757/767 of Joint Width
300mm Heavy Duty
787
Standard Cover Plate – Pages 28-29
801
804 1"-12"
25%-100% Standard
800 Series 806 25mm –
of Joint Width Moderate
802/807 300mm
808
Single Sightline – Page 30

2"-4"
50%-100%
300 Series 316 50mm – Moderate
of Joint Width
100mm

Pan Systems – Page 31

2"-8"
501 50%-100% Moderate
500 Series 50mm –
502 of Joint Width Heavy Duty
200mm

4 800.222.5556 | Installation Hotline: 866.ezinpro


Wall and Ceiling Systems

Joint Movement
System Type Series Models Loading Class
Opening +/-
Drywall Finishes – Pages 34-37
101
112 1"-6"
25%-50%
100 Series 113 25mm – N/A
of Joint Width
114 150mm
611
Drywall Finishes, Flush Mount – Pages 38-40
221
223 2"-36"
50%-100%
200 Series 233 50mm – N/A
of Joint Width
243 900mm
253
Glide Plate – Pages 42-43

1"-6"
300 50%-100%
300 Series 25mm – N/A
318 of Joint Width
150mm

Centering Bar – Page 43

2"-24"
481 50%-100%
400 Series 50mm – N/A
491 of Joint Width
600mm

Expansion Joint Systems


Surface Mount – Pages 44-45

811 1"-6"
25%-100%
800 Series 104 25mm – N/A
of Joint Width
118 150mm

Acoustical Ceiling – Page 35

1"-2"
50%-100%
800 Series 821 25mm – N/A
of Joint Width
50 mm

Acoustical Ceiling – Page 36

2"-4"
50%-100%
100 Series 115 50mm – N/A
of Joint Width
100mm

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 5


Exterior Joint Systems

Joint Movement
System Type Series Models Loading Class
Opening +/-
Seal Systems – Pages 48-49

615
2"-36"
616 50%-100%
600 Series 50mm – N/A
620 of Joint Width
600mm
621

Surface Mount – Pages 50-51

2"-24"
601 Stealth™ 50%-100%
600 Series 50mm – N/A
651 of Joint Width
600mm

Metal Roofing System – Pages 52-53

651 2"-8"
50%
600 Series 661 50mm – N/A
of Joint Width
691 200mm

Bellow System – Page 54

2"-36"
672 50%-100%
600 Series 50mm – N/A
674 of Joint Width
900 mm

6 800.222.5556 | Installation Hotline: 866.ezinpro


Seals and Accessories

Joint Movement Load/Rating


System Type Series Models
Opening +/- Class
Foam Seals – Page 56

1/2"-20"
1200 25%-100%
1200 Series 12.7mm – N/A
1250 of Joint Width
508mm

Foam Seals – Page 57

1100 1"-12"
25%-100%
1100 Series 1150 25.4mm – Standard
of Joint Width
1175 304.8mm

Compression Seals – Page 58

AR 1"-4"
Compression 25%-50%
CR 25mm – Heavy Duty
Seals of Joint Width
DR 100mm

Fire Barriers – Pages 60-61

975
950 1"-36" 2hr
25%-100%

Expansion Joint Systems


900 Series 921/925 25.4mm – 3hr
of Joint Width
935 914.4mm 4hr
990/995

Vapor and Insulated Barriers – Page 62

1"-36"
IVB 25%-100%
Barriers 25.4mm – N/A
RVB of Joint Width
914.4mm

Facility Protection – Pages 63-65

Speed Guards
Tire Stop
Facility
Corner Guards N/A N/A N/A
Protection
Wall Guards
Dock Bumper

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 7


Model Number Guide

101 - A01 - 025 Condition Joint


Series/ Model
Number Width

CONDITION SEAL COLOR

FRAME
HEIGHT

JOINT
WIDTH

Series | Model Loading Definitions


100 Elastomeric Seal Systems for Floors / Walls / Ceilings Standard / Moderate / and Heavy Duty are designations
200 Dual Elastomeric Seal Systems for Floors / Walls / Ceilings as they relate to load ratings. These are provided as
300 Glide Plate Seismic Systems for Floors / Walls / Ceilings a guideline to assist in making a preliminary product
400 Center Bar Seismic Systems for Floors / Walls / Ceilings selection for a given application.
500 Seismic “Pop-up” Systems for Floors and Walls
600 Exterior Seismic Systems for Walls and Roofs ••“Standard” suggests use in common applications such
as typical office settings or other spaces where pedestrian
700 Heavy Duty Seismic Systems for Floors
traffic or occasional rubber-wheeled traffic like mail carts
800 Cover Plate Systems for Floors / Walls / Ceilings and light-weight cleaning equipment, luggage, etc. is
900 Fire Barrier Systems the norm.
1000 Exterior Compression Seals
••“Moderate” suggests applications where occasional heavier
1100 Foam Seals
maintenance equipment with soft rubber tires (such as
1200 Silicone Foam Seals light duty scissor lifts, motorized cleaning equipment, etc.)
would be added to the standard traffic. The systems in this
Location category are comprised of heavier aluminum extrusions,
A01 Floor to Floor with thicker walled extruded rubber inserts.
A02 Floor to Wall ••“Heavy Duty” is for applications where truly heavy loads
A07 Wall to Wall or Ceiling to Ceiling (such as vehicles) or high-point loads (such as gurneys,
A09 Wall to Corner or Ceiling to Wall mobile medical equipment, coin carts, materials handling
V18 Ceiling to Wall for Acoustical Ceiling Systems equipment, etc.) are the norm. They are capable of multi-
V24 Ceiling to Ceiling for Acoustical Ceiling Systems directional movements and are also available in surface or
G01 Curb to Curb or Roof to Roof blockout mounted variations.
G02 Curb to Wall or Roof to Wall ••Contact your JointMaster® representative for more details
on project specific loading conditions.
Joint Width
025 1" (25mm) 400 16" (400mm)
038 1½" (38mm) 450 18" (450mm)
050 2" (51mm) 500 20" (500mm)
075 3" (76mm) 600 24" (600mm)
100 4" (102mm)
150 6" (150mm)
200 8" (200mm)
300 12" (300mm)
350 14" (350mm)

8 800.222.5556 | Installation Hotline: 866.ezinpro


Floor Systems

JointMaster® offers a variety of Floor Systems for both Thermal and Seismic applications.
From minimal sightlines to high load ratings, JointMaster Floor Systems are designed to
perform no matter the challenge.

Expansion Joint Systems

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 9


Floor Systems - Surface Mount

••Dual durometer seal provides secure fit and optimal flexibility.


••Frames adaptable to multiple floor finishes including concrete, VCT,
Surface mount designs make systems ideal sheet vinyl and carpet.
for renovations. 100 Series systems allow for ••Snap-fit design for easy on-site assembly.
Standard loading conditions such as offices, ••Optional integral vapor barrier available.
restaurants, cafeterias and clean rooms. ••Integrates with the following wall and ceiling systems:
••101-A07/A09
••104-A07/A09
••112-A07/A09
% of MOVEMENT VAPOR BARRIER
±25% optional ••113-A07/A09
••118-A07/A09
JOINT WIDTH fire rated ••Mill finish standard.
1" (25mm) – 3" (76mm) optional
••Standard and custom seal colors available, see pages 66-67.

103 Series – VCT


A01 Floor/Floor A02 Floor/Wall
(2" (51mm) system shown) (2" (51mm) system shown)
S

S H2
H2
H1

H1
W
W

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
103-A01-025 1" 25 5/8" 16 1/8" 4 4" 102 * * 1/4" 6 1/4" 6
103-A01-038 1 1/2" 38 5/8" 16 1/8" 4 4 1/2" 114 * * 3/8" 10 3/8" 10
Floor to Floor 103-A01-050 2" 51 1" 25 1/8" 4 4 7/8" 124 * * 1/2" 13 1/2" 13
103-A01-075 3" 76 1 1/8" 28 1/8" 4 6" 152 * * 3/4" 19 3/4" 19
103-A02-025 1" 25 5/8" 16 1/8" 4 2 1/2" 64 * * 1/4" 6 1/4" 6
103-A02-038 1 1/2" 38 5/8" 16 1/8" 4 2 15/16" 75 * * 3/8" 10 3/8" 10
Floor to Wall 103-A02-050 2" 51 1" 25 1/8" 4 3 3/8" 86 * * 1/2" 13 1/2" 13
103-A02-075 3" 76 1 1/8" 28 1/8" 4 4 1/2" 114 * * 3/4" 19 3/4" 19

10 800.222.5556 | Installation Hotline: 866.ezinpro


104 Series – Sheet Vinyl or Concrete
A01 Floor/Floor A02 Floor/Wall
(2" (51mm) system shown) (2" (51mm) system shown)

S
H1
H1
W
Not available online: A02-025, A02-050 W

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
104-A01-025 1" 25 5/8" 16 * * 4 3/4" 121 * * 1/4" 6 1/4" 6
104-A01-038 1 1/2" 38 5/8" 16 * * 5 1/8" 131 * * 3/8" 10 3/8" 10
Floor to Floor 104-A01-050 2" 51 1" 25 * * 5 5/8" 143 * * 1/2" 13 1/2" 13
104-A01-075 3" 76 1 1/ 8" 28 * * 6 5/8" 169 * * 3/4" 19 3/4" 19
104-A02-025 1" 25 5/8" 16 * * 2 7/8" 73 * * 1/4" 6 1/4" 6
104-A02-038 1
1 /2" 38 5/8" 16 * * 3 5/16" 84 * * 3/8" 10 3/8" 10
Floor to Wall 104-A02-050 2" 51 1" 25 * * 3 3/4" 95 * * 1/2" 13 1/2" 13
104-A02-075 3" 76 1 1/ 8" 28 * * 4 3/4" 121 * * 3/4" 19 3/4" 19

105 Series – Sheet Vinyl


A01 Floor/Floor A02 Floor/Wall
(2" (51mm) system show) (2" (51mm) system shown)

S
H1 H2

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
105-A01-025 1" 25 5/8" 16 1/8" 3 1" 25 * * 1/4" 6 1/4" 6
105-A01-038 1 1/2" 38 5/8" 16 1/8" 3 1 1/2" 36 * * 3/8" 10 3/8" 10
Floor to Floor 105-A01-050 2" 51 1" 25 1/8" 3 2" 47 * * 1/2" 13 1/2" 13
105-A01-075 3" 76 1 1/8" 28 1/8" 3 3" 73 * * 3/4" 19 3/4" 19

Expansion Joint Systems


105-A02-025 1" 25 5/8" 16 1/8" 3 1" 25 * * 1/4" 6 1/4" 6
105-A02-038 1
1 /2" 38 5/8" 16 1/8" 3 1
1 /2" 36 * * 3/8" 10 3/8" 10
Floor to Wall 105-A02-050 2" 51 1" 25 1/8" 3 2" 47 * * 1/2" 13 1/2" 13
105-A02-075 3" 76 1 1/8" 28 1/8" 3 3" 73 * * 3/4" 19 3/4" 19

106 Series – Carpet


A01 Floor/Floor A02 Floor/Wall
(2" (51mm) system shown) (2" (51mm) system shown)

S
H1 H2

W
W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
106-A01-025 1" 25 5/8" 16 1/4" 6 1" 25 * * 1/4" 6 1/4" 6
106-A01-038 1 1/2" 38 5/8" 16 1/4" 6 1 1/2" 36 * * 3/8" 10 3/8" 10
Floor to Floor 106-A01-050 2" 51 1" 25 1/4" 6 2" 47 * * 1/2" 13 1/2" 13
106-A01-075 3" 76 1 1/8" 28 1/4" 6 3" 73 * * 3/4" 19 3/4" 19
106-A02-025 1" 25 5/8" 16 1/4" 6 1" 25 * * 1/4" 6 1/4" 6
106-A02-038 1 1/2" 38 5/8" 16 1/4" 6 1 1/2" 36 * * 3/8" 10 3/8" 10
Floor to Wall 106-A02-050 2" 51 1" 25 1/4" 6 2" 47 * * 1/2" 13 1/2" 13
106-A02-075 3" 76 1 1/8" 28 1/4" 6 3" 73 * * 3/4" 19 3/4" 19

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 11


Floor Systems - Flush, Recessed

••Surface mount design makes systems ideal for renovations


(132, 133, 141 systems).
Flush mount frames are adaptable to ••Dual durometer seal provides secure fit and optimal flexibility.
any floor finish. 100 Series systems are ••Snap-fit design for easy on-site assembly.
ideal for Standard loading conditions ••Optional integral vapor barrier (101 system) slides directly into
such as those encountered in showrooms, frame for easy installation.
restrooms and lobbies. ••Integrates with the following wall and ceiling systems:
••101-A07/A09
••112-A07/A09
••113-A07/A09
% of MOVEMENT VAPOR BARRIER
±25% optional ••118-A07/A09
••Mill finish standard.
JOINT WIDTH fire rated ••Standard and custom seal colors available, see pages 66-67.
1" (25mm) – 3" (76mm) optional

101 Series – Any Floor Type

A02 Floor/Wall
S
A01 Floor/Floor
(2" (51mm) system shown) (1" (25mm) system shown)

S
H1 H1
W
W

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
101-A01-025 1" 25 1 1/2" 38 * * 1" 25 2 1/2" 64 1/4" 6 1/4" 6
101-A01-038 1 1/2" 38 1 1/2" 38 * * 1 7/16" 36 2 1/2" 64 3/8" 10 3/8" 10
Floor to Floor 101-A01-050 2" 51 1 1/2" 38 * * 1 7/8" 47 2 1/2" 64 1/2" 13 1/2" 13
101-A01-075 3" 76 1 1/2" 38 * * 2 7/8" 73 2 1/2" 64 3/4" 19 3/4" 19
101-A02-025 1" 25 1 1/2" 38 * * 1" 25 2 1/2" 64 1/4" 6 1/4" 6
101-A02-038 1 1/2" 38 1 1/2" 38 * * 1 7/16" 36 2 1/2" 64 3/8" 10 3/8" 10
Floor to Wall 101-A02-050 2" 51 1 1/2" 38 * * 1 7/8" 47 2 1/2" 64 1/2" 13 1/2" 13
101-A02-075 3" 76 1 1/2" 38 * * 2 7/8" 73 2 1/2" 64 3/4" 19 3/4" 19
Standard frame height for recessed side 1 1/2" (38mm), 1" (25mm) and 2" (50mm) available.

12 800.222.5556 | Installation Hotline: 866.ezinpro


120 Series – Any Floor Type
A01 Floor/Floor A02 Floor/Wall SS
1" (25mm) system shown) 1" (25mm) system shown)
S

H1
H1
H1

W
W

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
120-A01-025 1" 25 1"-1 1/2"-2" 25-38-50 * * 1" 25 2 1/2" 64 1/4" 6 1/4" 6
Floor to Floor 120-A01-038 1 1/2" 38 1"-1 1/2"-2" 25-38-50 * * 1 3/8" 35 2 1/2" 64 3/8" 10 3/8" 10
120-A02-025 1" 25 1"-1 1/2"-2" 25-38-50 * * 1" 25 2 1/2" 64 1/4" 6 1/4" 6
Floor to Wall 120-A02-038 1 1/2" 38 1"-1 1/2"-2" 25-38-50 * * 1 3/18" 36 2 1/2" 64 3/8" 10 3/8" 10

Standard frame height for recessed side 1 1/2" (38mm), 1" (25mm) and 2" (50mm) available.

132 - Sheet Vinyl  133 - Carpet Series


133-A01 Floor/Floor 132-A02 Floor/Wall
2" (51mm) system shown)
2" (51mm) system shown)
H2
H2
SS H2
H2 SS

H1
H1
H1
H1

W
W
W
W

W H1 H2 S B Movement +/-

Expansion Joint Systems


Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
132-A01-050 2" 50 5/8" 16 1/8" 3 1 7/8" 47 2 1/2" 64 1/2" 13 1/2" 13
132-A01-075 3" 75 5/8" 16 1/8" 3 1 7/8" 47 2 1/2" 64 1/2" 13 1/2" 13
Floor to Floor 133-A01-050 2" 50 5/8" 16 3/8" 10 1 7/8" 47 2 1/2" 64 1/2" 13 1/2" 13
133-A01-075 3" 75 5/8" 16 3/8" 10 1 7/8" 47 2 1/2" 64 1/2" 13 1/2" 13
132-A02-050 2" 50 5/8" 16 1/8" 3 1 7/8" 47 2 1/2" 64 1/2" 13 1/2" 13
132-A02-075 3" 75 5/8" 16 1/8" 3 1 7/8" 47 2 1/2" 64 1/2" 13 1/2" 13
Floor to Wall 133-A02-050 2" 50 5/8" 16 3/8" 10 1 7/8" 47 2 1/2" 64 1/2" 13 1/2" 13
133-A02-075 3" 75 5/8" 16 3/8" 10 1 7/8" 47 2 1/2" 64 1/2" 13 1/2" 13

141 - Carpet and VCT


S
H1 H2
A01 Floor/Floor
2" (51mm) system shown)

W
W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
141-A01-025 1" 25 5/8" 16 * * 5 5/8" 142 2 3/4" 70 1/4" 6 1/4" 6
Floor to Floor 141-A01-038 1 1/2" 35 5/8" 16 * * 6" 153 2 3/4" 70 3/8" 10 3/8" 10
141-A01-050 2" 50 5/8" 16 * * 6 1/2" 164 2 3/4" 70 1/2" 13 1/2" 13

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 13


Floor Systems - New to Existing

••Dual durometer seal provides secure fit and optimal flexibility.


This series is designed for retrofits, additions ••Snap-fit design allows easy on-site assembly.
and renovations where blockout occurs on
••Optional integral vapor barrier slides directly into frame for
one side only. 100 systems allow for Standard easy installation.
loading conditions such as offices, cafeterias ••Integrates with the following wall and ceiling systems:
and clean rooms.
••101-A07/A09
••104-A07/A09
% of MOVEMENT VAPOR BARRIER ••112-A07/A09
±25% optional ••113-A07/A09
JOINT WIDTH ••Mill finish standard.
fire rated
1" (25mm) – 3" (76mm) optional ••Standard and custom seal colors available, see pages 66-67.

107 Series - Finished Concrete


A01 Floor/Floor
(1" (25mm) system shown) S
H1

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
107-A01-025 1" 25 1 1/ 2" 38 * * 2 7/8" 73 2 1/2" 64 1/4" 6 1/4" 6
107-A01-038 1 1/2" 38 1 1/ 2" 38 * * 3 5/16" 84 2 1/2" 64 3/8" 10 3/8" 10
Floor to Floor 107-A01-050 2" 51 1 1/ 2" 38 * * 3 3/ 4" 95 2 1/2" 64 1/2" 13 1/2" 13
107-A01-075 3" 76 1 1/ 2" 38 * * 4 3/ 4" 121 2 1/2" 64 3/4" 19 3/4" 19

Standard frame height for recessed side 1 1/2" (38mm), 1" (25mm) and 2" (50mm) available.

14 800.222.5556 | Installation Hotline: 866.ezinpro


108 Series - Sheet Vinyl
A01 Floor/Floor
(1" (25mm) system shown) S
H2
H1

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
108-A01-025 1" 25 1 1/2" 38 1/8" 3 1" 25 2 1/2" 64 1/4" 6 1/4" 6
108-A01-038 1 1/2" 38 1 1/2" 38 1/8" 3 1 1/2" 36 2 1/2" 64 3/8" 10 3/8" 10
Floor to Floor 108-A01-050 2" 51 1 1/2" 38 1/8" 3 2' 47 2 1/2" 64 1/2" 13 1/2" 13
108-A01-075 3" 76 1 1/2" 38 1/8" 3 3" 73 2 1/2" 64 3/4" 19 3/4" 19

Standard frame height for recessed side 1 1/2" (38mm), 1" (25mm) and 2" (50mm) available.

109 Series - Carpet


A01 Floor/Floor
(1" (25mm) system shown) S
H2
H1

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
109-A01-025 1" 25 1 1/2" 38 1/4" 6 1" 25 2 1/2" 64 1/4" 6 1/4" 6
109-A01-038 1 1/2" 38 1 1/2" 38 1/4" 6 1 1/2" 36 2 1/2" 64 3/8" 10 3/8" 10
Floor to Floor 109-A01-050 2" 51 1 1/2" 38 1/4" 6 2" 47 2 1/2" 64 1/2" 13 1/2" 13
109-A01-075 3" 76 1 1/2" 38 1/4" 6 3" 73 2 1/2" 64 3/4" 19 3/4" 19

Standard frame height for recessed side 1 1/2" (38mm), 1" (25mm) and 2" (50mm) available.

Expansion Joint Systems


110 Series - VCT
A01 Floor/Floor S
(2" (51mm) system shown) H2
H1

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
110-A01-025 1" 25 1 1/2" 38 1/8" 4 2 1/2" 64 2 1/2" 64 1/4" 6 1/4" 6
110-A01-038 1 1/2" 38 1 1/2" 38 1/8" 4 2 5/6" 75 2 1/2" 64 3/8" 10 3/8" 10
Floor to Floor 110-A01-050 2" 51 1 1/2" 38 1/8" 4 3 3/8" 86 2 1/2" 64 1/2" 13 1/2" 13
110-A01-075 3" 76 1 1/2" 38 1/8" 4 4 1/2" 113 2 1/2" 64 3/4" 19 3/4" 19

Standard frame height for recessed side 1 1/2" (38mm), 1" (25mm) and 2" (50mm) available.

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 15


Floor Systems - Recessed Mount

••Recessed mount frames for minimal sightline, adaptable with


Snap-fit design for easy on-site assembly. 200 many floor finishes.
Series systems allow for Moderate loading ••Dual durometer seal provides secure fit and optimal flexibility.
applications while meeting a wide range of ••Double seals absorb limited serviceable seismic movement.
joint sizes. ••Integrates with the following wall and ceiling systems:
••221-A07/A09
% of MOVEMENT VAPOR BARRIER ••223-A07/A09
±50% optional ••233-A07/A09
••Mill finish standard.
JOINT WIDTH fire rated
optional ••Standard and custom seal colors available, see pages 66-67.
2 " (50mm – 6" (150mm)

221 Series - Any Flooring Type (Flush)


A01 Floor/Floor
(4" (100mm) system shown) S
H1

W
W H1 S B Movement +/-
Application System Joint Width Frame Height 1 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm
221-A01-050 2" 51 5/8" 16 4 7/ 8 " 124 1 1/2" 13 1” 25 1” 25
221-A01-100 4" 102 5/8" 16 9 3/ 8 " 238 2 3/4" 70 2” 51 2” 51
221-A01-150 6" 152 5/8" 16 11 3/8" 289 2 3/4" 70 3” 75 3” 75
221-A01-200 8" 200 5/8" 16 18" 457 4 1/2" 114 4” 102 4” 102
Floor to Floor 221-A01-250 10" 250 5/8" 16 21" 533 4 1/2" 114 5” 125 5” 125
221-A01-300 12" 300 5/8" 16 24" 609 4 1/2" 114 6” 152 6” 152
221-A01-350 14" 350 5/8" 16 27" 686 4 1/2" 114 7” 178 7” 178
221-A01-400 16" 400 5/8" 16 30" 762 4 1/2" 114 8” 203 8” 203
221-A01-450 18" 450 5/8" 16 33" 838 4 1/2" 114 9” 228 9” 228
221-A02-050 2" 51 5/8" 16 3 1/ 2 " 89 1 1/2" 13 1/4" 6 1/4" 6
221-A02-100 4" 102 5/8" 16 6 5/ 8 " 168 2 3/4" 70 1/2" 13 1/2" 13
221-A02-150 6" 152 5/8" 16 8 5/ 8 " 219 2 3/4" 70 1/2" 13 1/2" 13
221-A02-200 8" 200 5/8" 16 13" 330 4 1/2" 114 2 51 2 51
Floor to Wall 221-A02-250 10" 250 5/8" 16 15 1/2" 394 4 1/2" 114 2 1/2" 64 2 1/2" 64
221-A02-300 12" 300 5/8" 16 18" 457 4 1/2" 114 3 76 3 76
221-A02-350 14" 350 5/8" 16 20 1/2" 521 4 1/2" 114 3 1/2" 89 3 1/2" 89
221-A02-400 16" 400 5/8" 16 23" 584 4 1/2" 114 4 102 4 102
221-A02-450 18" 450 5/8" 16 25 1/2" 648 4 1/2" 114 4 1/2" 114 4 1/2" 114
Larger sizes available

16 800.222.5556 | Installation Hotline: 866.ezinpro


222 Series - VCT
SS SS H2
H2

A01 Floor/Floor for VCT


4" (100mm) system shown) H1
H1

W
W

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
222-A01-050 2" 51 5/8" 16 1/8" 3 2" 51 1 1/2" 13 1” 25 1” 25
222-A01-100 4" 102 5/8" 16 1/8" 3 4" 102 2 3/4" 70 2” 51 2” 51
222-A01-150 6" 152 5/8" 16 1/8" 3 4" 102 2 3/4" 70 3” 75 3” 75
222-A01-200 8" 200 5/8" 16 1/8" 3 6" 152 4 1/2" 114 4” 102 4” 102
Floor to Floor 222-A01-250 10" 250 5/8" 16 1/8" 3 6" 152 4 1/2" 114 5” 125 5” 125
222-A01-300 12" 300 5/8" 16 1/8" 3 6" 152 4 1/2" 114 6” 152 6” 152
222-A01-350 14" 350 5/8" 16 1/8" 3 6" 152 4 1/2" 114 7” 178 7” 178
222-A01-400 16" 400 5/8" 16 1/8" 3 6" 152 4 1/2" 114 8” 203 8” 203
222-A01-450 18" 450 5/8" 16 1/8" 3 6" 152 4 1/2" 114 9” 228 9” 228
222-A02-050 2" 51 5/8" 16 1/8" 3 1" 25 1 1/2" 13 1/4" 6 1/4" 6
222-A02-100 4" 102 5/8" 16 1/8" 3 2" 51 2 3/4" 70 1/2" 13 1/2" 13
222-A02-150 6" 152 5/8" 16 1/8" 3 2" 51 2 3/4" 70 1/2" 13 1/2" 13
222-A02-200 8" 200 5/8" 16 1/8" 3 3" 152 4 1/2" 114 2 51 2 51
Floor to Wall 222-A02-250 10" 250 5/8" 16 1/8" 3 3" 152 4 1/2" 114 2 1/2" 64 2 1/2" 64
222-A02-300 12" 300 5/8" 16 1/8" 3 3" 152 4 1/2" 114 3 76 3 76
222-A02-350 14" 350 5/8" 16 1/8" 3 3" 152 4 1/2" 114 3 1/2" 89 3 1/2" 89
222-A02-400 16" 400 5/8" 16 1/8" 3 3" 152 4 1/2" 114 4 102 4 102
222-A02-450 18" 450 5/8" 16 1/8" 3 3" 152 4 1/2" 114 4 1/2" 114 4 1/2" 114

223 Series - Tile or Carpet (3/8"/10mm)


A01 Floor/Floor for 3/8" (10mm) Floor Finishes
(4" (100mm) system shown)

SS SS H2
H2

H1
H1

Expansion Joint Systems


W
W

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
223-A01-050 2" 51 5/8" 16 3/8" 10 2" 51 1 1/2" 13 1” 25 1” 25
223-A01-100 4" 102 5/8" 16 3/8" 10 4" 100 2 3/4" 70 2” 51 2” 51
223-A01-150 6" 152 5/8" 16 3/8" 10 4" 100 2 3/4" 70 3” 75 3” 75
223-A01-200 8" 200 5/8" 16 1/4" 7 6" 152 5" 114 4” 102 4” 102
Floor to Floor 223-A01-250 10" 250 5/8" 16 1/4" 7 6" 152 5 1/2" 114 5” 125 5” 125
223-A01-300 12" 300 5/8" 16 1/4" 7 6" 152 6" 114 6” 152 6” 152
223-A01-350 14" 350 5/8" 16 1/4" 7 6" 152 6 1/2" 114 7” 178 7” 178
223-A01-400 16" 400 5/8" 16 1/4" 7 6" 152 7" 114 8” 203 8” 203
223-A01-450 18" 450 5/8" 16 1/4" 7 6" 152 7 1/2" 114 9” 228 9” 228
223-A02-050 2" 51 5/8" 16 3/8" 10 1" 25 1 1/2" 13 1/4" 6 1/4" 6
223-A02-100 4" 102 5/8" 16 3/8" 10 2" 51 2 3/4" 70 1/2" 13 1/2" 13
223-A02-150 6" 152 5/8" 16 3/8" 10 2" 51 2 3/4" 70 1/2" 13 1/2" 13
223-A02-200 8" 200 5/8" 16 1/4" 7 3" 76 5" 114 2 51 2 51
Floor to Wall 223-A02-250 10" 250 5/8" 16 1/4" 7 3" 76 5 1/2" 114 2 1/2" 64 2 1/2" 64
223-A02-300 12" 300 5/8" 16 1/4" 7 3" 76 6" 114 3 76 3 76
223-A02-350 14" 350 5/8" 16 1/4" 7 3" 76 6 1/2" 114 3 1/2" 89 3 1/2" 89
223-A02-400 16" 400 5/8" 16 1/4" 7 3" 76 7" 114 4 102 4 102
223-A02-450 18" 450 5/8" 16 1/4" 7 3" 76 7 1/2" 114 4 1/2" 114 4 1/2" 114

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 17


Floor Systems - Glide Plate

••Exclusive patented “no-bump" configuration makes system ADA


compliant (patent #5384996).
Glide plate cover provides a smooth
••Cover plates rest on high durometer seals to eliminate system rattle.
and durable transition over expansion
joints. 300 Series systems meet ••Mill finish standard.
Standard to Moderate loading ••Available finish options on pages 66-67.
conditions, are seismic-capable and % of MOVEMENT VAPOR BARRIER
have unlimited shear movement. Ideal ±50% optional
for public areas such as schools, civic
centers and airports. JOINT WIDTH fire rated
1" (50mm) – 6" (152mm) optional

300 Series - Recessed Mount

Concealed hardware
configuration makes
system tamper proof for
public space applications.

Recessed frame accommodates


all floor finishes including
concrete, terrazzo, tile, VCT
and carpet.

Smooth transition ideal


for rolling carts.

A01 Floor/Floor S
(2" (51mm) system shown) A02 Floor/Wall
S (2" (51mm) system shown)
H1
H1

W
W
W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal
US mm US mm US mm US mm US mm US mm
300-A01-025 1" 25 1" 25 * * 3 1/4" 83 2 3/4" 70 1/2" 13
300-A01-050 2" 51 1" 25 * * 5 1/4" 133 3 1/4" 83 1" 25
Floor to Floor 300-A01-075 3" 76 1" 25 * * 7 1/8" 181 3 3/4" 95 1 1/2" 38
300-A01-100 4" 102 1" 25 * * 9 1/8" 232 4 1/4" 108 2" 51
300-A01-150 6" 152 1" 25 * * 13 1/8" 333 5 1/4" 133 3" 76
300-A02-025 1" 25 1" 25 * * 2 1/8" 5 2 3/4" 70 1/8" 3
300-A02-050 2" 51 1" 25 * * 3 5/8" 92 3 1/4" 83 3/8" 10
Floor to Wall 300-A02-075 3" 76 1" 25 * * 5" 127 3 3/4" 95 9/16" 14
300-A02-100 4" 102 1" 25 * * 6 5/8" 168 4 1/4" 108 3/4" 19
300-A02-150 6" 152 1" 25 * * 9 1/2" 241 5 1/4" 133 1 1/4" 31

18 800.222.5556 | Installation Hotline: 866.ezinpro


304 Series - Recessed Mount/VCT
A02 Floor/Wall
(2" (51mm) system shown) S
A01 Floor/Floor
(2" (51mm) system shown)
S H2 H2
H1 H1
W W
••1/8" (3mm) nosing designed
specifically for vinyl floors.

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal
US mm US mm US mm US mm US mm US mm
304-A01-025 1" 25 1" 25 1/8" 3" 2 5/8" 67 2 3/4" 70 1/2" 13
304-A01-050 2" 51 1" 25 1/8" 3" 3 5/8" 92 3 1/4" 83 1" 25
Floor to Floor 304-A01-075 3" 76 1" 25 1/8" 3" 4 5/8" 117 3 3/4" 95 1 1/ 2 " 38
304-A01-100 4" 102 1" 25 1/8" 3" 5 5/8" 143 4 1/4" 108 2" 51
304-A01-150 6" 152 1" 25 1/8" 3" 7 5/8" 194 5 1/4" 133 3" 76
304-A02-025 1" 25 1" 25 1/8" 3" 1 3/4" 44 2 3/4" 70 1/8" 3
304-A02-050 2" 51 1" 25 1/8" 3" 2 3/4" 70 3 1/4" 83 3/8" 10
Floor to Wall 304-A02-075 3" 76 1" 25 1/8" 3" 3 3/4" 95 3 3/4" 95 9/16" 14
304-A02-100 4" 102 1" 25 1/8" 3" 4 3/4" 121 4 1/4" 108 3/4" 19
304-A02-150 6" 152 1" 25 1/8" 3" 6 3/4" 171 5 1/4" 133 1 1/ 4 " 31

312 Series - Recessed Mount


A02 Floor/Wall
(2" (51mm) system shown)
A01 Floor/Floor S
(2" (51mm) system shown)

S
H1 H1
••Surface mount flanges conceal
damaged flooring edges. W W
W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal
US mm US mm US mm US mm US mm US mm
312-A01-050 2"
312-A01-050 51 1" 25 * * 10 1/8" 257 1 7/8" 48 1" 25
Floor to Floor 312-A01-075 3" 75 1" 25 * * 131/8" 332 2 7/8" 73 11/2" 38
312-A01-100 4" 102 1" 25 * * 14 1/8" 358 2 7/8" 73 2" 51

Expansion Joint Systems


312-A02-050 2" 51 1" 25 * * 6" 152 1 7/8" 48 3/8" 10
Floor to Wall 312-A02-075 3" 75 1" 25 * * 7" 178 1 7/8" 48 9/16" 14
312-A02-100 4" 102 1" 25 * * 9" 229 2 7/8" 73 3/4" 19

320 Series - New to Existing


A01 Floor/Floor
(2" (51mm) system shown)

S
H1

••Designed for retrofits, additions and renovations where


blockout occurs on one side only. W
••Optional integral vapor barrier slides directly into frame for
easy installation.

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
320-A01-025 1" 25 1" 25 * * 4 5/8" 117 2 3/4" 70 1/8" 3 1/4" 6
320-A01-050 2" 51 1" 25 * * 6 1/8" 156 3 1/4" 83 3/8" 10 1/2" 13
Floor to Floor 320-A01-075 3" 76 1" 25 * * 7 5/8" 194 3 3/4" 95 9/16" 14 3/4" 19
320-A01-100 4" 102 1" 25 * * 9 1/8" 232 4 1/4" 108 3/4" 19 1" 25
320-A01-150 6" 152 1" 25 * * 12 1/8" 308 5 1/4" 133 1 1/4" 31 1 1/2" 38

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 19


Floor Systems - Centering Bar

400 Series systems meet Moderate to Heavy Duty loading scenarios


such as warehouses, stadiums and auditoriums. The center bar and ••Highly modifiable systems can meet
compression spring assembly correctly reposition pan after thermal any project's loads, movement and
and seismic movement. finish requirements.

401 Series
A02 Floor/Wall
(2" (51mm) system shown)
••Perfect for carpeted conditions.
••Cost effective, surface mounted S
system with wide span
capability.
••Throat-mounted bracket allows
S your project's wall base to
H1
continue uninterrupted over
H1 the joint cover at floor/wall
A01 Floor/Floor conditions. W
(2" (51mm) system shown)
W
W H1 H2 S Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Horizontal Vertical
US mm US mm US mm US mm US mm US mm
401-A01-050 2" 51 1/8" 3 * * 8 1/2" 216 1" 25 1" 25
401-A01-100 4" 102 1/8" 3 * * 11 3/4" 298 2" 50 2" 50
Floor to Floor 401-A01-150 6" 152 3/16" 5 * * 14 1/2" 368 3" 75 3" 75
401-A01-200 8" 203 3/16" 5 * * 16 1/2" 419 4" 100 4" 100
401-A02-050 2" 50 1/8" 3 * * 5 1/4" 132 1" 25 1/2" 13
401-A02-100 4" 100 1/8" 3 * * 8" 202 2" 50 1” 25
Floor to Wall 401-A02-150 6" 150 3/16" 5 * * 10 1/4" 259 3" 75 1-1/2” 38
401-A02-200 8" 203 3/16" 5 * * 12 1/2" 419 4" 100 2” 51
Wider sizes available v

421 | 423 | 425 Series - Extra Wide


••Ideal for a wide range flooring conditions.
421 - A01 Floor/Floor
••Highly modifiable system – variable plate (14" (350mm) system shown)
thicknesses allow system to meet many load
scenarios.
S
S
••421 series contains all aluminum
components. H1
••Stainless steel plate available on 423 system.
••Stainless steel plate and wings available on W
W

425 system.

W H1 H2 S B Movement +/-
Application System
(421,423,425) Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
421-A01-300 12" 300 1 5/8" 43 * * 28 7/8" 735 8 7/8" 225 6" 152 6" 152
421-A01-350 14" 350 1 5/8" 43 * * 33 1/8" 843 10" 254 7" 178 7" 178
Floor to Floor 421-A01-400 16" 400 1 7/8" 48 * * 38 5/8" 983 11 3/4" 298 8" 203 8" 203
421-A01-450 18" 450 1 7/8" 48 * * 42 3/4" 1087 12 3/4" 324 9" 229 9" 229
421-A02-300 12" 300 1 5/8" 43 * * 20 1/2" 520 8 7/8" 225 3" 76 1 1/2” 38
421-A02-350 14" 350 1 5/8" 43 * * 23 5/8" 599 10" 254 3 1/2" 90 1 3/4” 44
Floor to Wall 421-A02-400 16" 400 1 7/8" 48 * * 27 3/8" 694 11 3/4" 298 4" 102 2” 51
421-A02-450 18" 450 1 7/8" 48 * * 30 3/8" 772 12 3/4" 324 4 1/2" 114 2 1/4” 57
Smaller and larger size configurations available

20 800.222.5556 | Installation Hotline: 866.ezinpro


426 | 427 | 428 Series - Extra Wide
••Full width cover plate creates a seamless transition over
wide structural gaps.
••Can be installed with VCT for a narrow sightline (427
System).
••Can be installed with carpet or tile for a narrow
sightline (428 System).
••Throat-mounted bracket allows your project's wall base
to continue uninterrupted over the joint cover at floor/
wall conditions.
S S
H2
S S
428 - A01 Floor/Floor for Carpet H2
(14" (350mm) system shown)
H1
H1

W W

427 - A01 Floor/Floor for VCT S


S H2
H2 S
S

(14" (350mm) system shown)


H1H1

W W

426 - A01 Floor/Floor


(14" (350mm) system shown)
SS H1
H1

W
W

426 - A02 Floor/Wall SS


(14" (350mm) system shown)

H1
H1

Expansion Joint Systems


W
W

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
426-A01-300 12" 300 1 5/8" 43 * * 28 1/8" 735 8 1/2" 216 6" 152 6" 152
426-A01-350 14" 350 1 5/8" 43 * * 33 1/8" 843 10" 254 7" 178 7" 178
426-A01-400 16" 400 1 7/8" 48 * * 38 5/8" 983 11 3/4" 298 8" 203 8" 203
426-A01-450 18" 450 1 7/8" 48 * * 42 3/4" 1087 12 3/4" 330 9" 229 9" 229
427-A01-300 12" 300 1 5/8" 43 1/8" 3 3 3/4" 95 10" 254 6" 152 6" 152
427-A01-350 14" 350 1 5/8" 43 1/8" 3 3 3/4" 95 10 1/2" 267 7" 178 7" 178
Floor to Floor 427-A01-400 16" 400 1 7/8" 48 1/8" 3 3 3/4" 95 12 1/8" 308 8" 203 8" 203
427-A01-450 18" 450 1 7/8" 48 1/8" 3 3 3/4" 95 13 1/8" 333 9" 229 9" 229
428-A01-300 12" 300 1 5/8" 43 3/8" 10 3 3/4" 95 10" 254 6" 152 6" 152
428-A01-350 14" 350 1 5/8" 43 3/8" 10 3 3/4" 95 11 1/8" 283 7" 178 7" 178
428-A01-400 16" 400 1 7/8" 48 3/8" 10 3 3/4" 95 12 3/4" 325 8" 203 8" 203
428-A01-450 18" 450 1 7/8" 48 3/8" 10 3 3/4" 95 13 3/4" 351 9" 229 9" 229
426-A02-300 12" 300 1 5/8" 43 * * 20 1/2" 520 8 7/8" 216 3" 76 3" 76
426-A02-350 14" 350 1 5/8" 43 * * 23 5/8" 599 10" 254 3 1/ 2" 90 3 1/2" 90
426-A02-400 16" 400 1 7/8" 48 * * 27 3/8" 694 11 3/4" 298 4" 102 4" 102
426-A02-450 18" 450 1 7/8" 48 * * 30 3/8" 772 12 3/4" 303 4 1/ 2" 114 4 1/2" 114
427-A02-300 12" 300 1 5/8" 43 1/8" 3 1 7/8" 47 10" 254 3" 76 3" 76
427-A02-350 14" 350 1 5/8" 43 1/8" 3 1 7/8" 47 10 1/2" 267 3 1/2" 90 3 1/2" 90
Floor to Wall 427-A02-400 16" 400 1 7/8" 48 1/8" 3 1 7/8" 47 12 1/8" 308 4" 102 4" 102
427-A02-450 18" 450 1 7/8" 48 1/8" 3 1 7/8" 47 13 1/8" 333 4 1/2" 114 4 1/2" 114
428-A02-300 12" 300 1 5/8" 43 3/8" 10 1 7/8" 47 10" 254 3" 76 3" 76
428-A02-350 14" 350 1 5/8" 43 3/8" 10 1 7/8" 47 11 1/8" 283 3 1/2" 90 3 1/2" 90
428-A02-400 16" 400 1 7/8" 48 3/8" 10 1 7/8" 47 12 3/4" 325 4" 102 4" 102
428-A02-450 18" 450 1 7/8" 48 3/8" 10 1 7/8" 47 13 3/4" 351 4 1/2" 114 4 1/2" 114
Smaller and larger size configurations available

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 21


Floor Systems - Centering Bar

••Mill finish standard.


400 Series systems meet Moderate loading
scenarios such as medical office buildings,
hospital corridors and school assembly spaces. % of MOVEMENT VAPOR BARRIER
The center bar and compression spring assembly ±50% optional
correctly reposition pan after seismic movement. JOINT WIDTH fire rated
1" (25mm) – 8" (200mm) optional

430 Recessed Mount - Hidden Fastener


432 Recessed Mount - Exposed Fastener

Industry unique,
tapered center plate
design creates an
extremely smooth
transition, ideal for
rolling loads.

Ideal for carpet, vinyl,


ceramic tile and other
floor finishes.
F looring may be inserted under
cover plate for reduced sightline.

430-A02 Floor/Wall Hidden Fastener Model 430-A01 Floor/Floor Exposed Fastener Model 432-A01 Floor/Floor
(2" (51mm) system shown) (2" (51mm) system shown) (2" (51mm) system shown)
SS S
1 78 ” S
[49mm]
H1 H1
H1H1

W
W
W W
W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
430-A01-025 1" 25 1 1/2" 38 * * 4 1/8" 105 3" 76 1/2" 13 1/4" 6
430-A01-050 2" 51 1 1/2" 38 * * 5 1/2" 140 3 1/4" 83 1" 25 1/2" 13
430-A01-075 3" 76 1 1/2" 38 * * 7 3/4" 197 4" 102 1 1/2" 38 3/4" 19
430-A01-100 4" 102 1 1/2" 38 * * 8 3/4" 222 4" 102 2" 51 1" 25
430-A01-150 6" 152 1 1/2" 38 * * 13 1/2" 343 1
5 /4" 133 3" 76 1 1/2" 38
430-A01-200 8" 203 1 1/2" 38 * * 18" 457 7" 178 4" 102 2" 51
Floor to Floor 432-A01-025 1" 25 1 1/2" 38 * * 4 1/8" 105 3" 76 1/2" 13 1/4" 6
432-A01-050 2" 51 1 1/2" 38 * * 5 1/2" 140 3 1/4" 83 1" 25 1/2" 13
432-A01-075 3" 76 1 1/2" 38 * * 7 3/4" 197 4" 102 1 1/2" 38 3/4" 19
432-A01-100 4" 102 1 1/2" 38 * * 8 3/4" 222 4" 102 2" 51 1" 25
432-A01-150 6" 152 1 1/2" 38 * * 13 1/2" 343 5 1/4" 133 3" 76 1 1/2" 38
432-A01-200 8" 203 1 1/2" 38 * * 18" 457 7" 178 4" 102 2" 51
430-A02-025 1" 25 1 1/2" 38 * * 2 1/2" 64 3" 76 1/4" 6 1/4" 6
430-A02-050 2" 51 1 1/2" 38 * * 3 3/4" 95 3 1/4" 83 1/2" 13 1/2" 13
430-A02-075 3" 76 1 1/2" 38 * * 5 3/8" 137 4" 102 3/4" 19 3/4" 19
Floor to Wall 430-A02-100 4" 102 1 1/2" 38 * * 6 3/8" 162 4" 102 1" 25 1" 25
430-A02-150 6" 152 1 1/2" 38 * * 9 3/4" 248 5 1/4" 133 1 1/2" 38 1 1/2" 38
430-A02-200 8" 203 1 1/2" 38 * * 13" 330 7" 178 2" 51 2" 51

22 800.222.5556 | Installation Hotline: 866.ezinpro


441 Series - Recessed Mount
S
441-A02 Floor/Wall
(2" (51mm) system shown)

H1

441-A01 Floor/Floor W
(2" (51mm) system shown) S
••Flooring may be inserted under plate for H1
reduced sightline.
••Exposed fastener makes maintenance easier.
W
W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
441-A01-050 2" 50 1" 25 * * 8 1/2" 216 3 1/4" 83 1" 25 1" 25
Floor to Floor 441-A01-100 4" 100 1" 25 * * 11 3/4" 298 3 1/4" 83 2" 50 2" 50
441-A01-150 6" 150 1" 25 * * 14 1/2" 368 3 1/4" 83 3" 75 3" 75
441-A02-050 2" 50 1" 25 * * 5 1/4" 132 3 1/4" 83 1" 25 1/2" 13
Floor to Wall 441-A02-100 4" 100 1" 25 * * 8" 202 3 1/4" 83 2" 50 1” 25
441-A02-150 6" 150 1" 25 * * 10 1/4" 259 3 1/4" 83 3" 75 1-1/2” 38
Other sizes and finishes available

461 Series - New to Existing


461-A01 Floor/Floor
(4" (100mm) system shown)
••Designed for retrofits, additions and renovations where S
blockout occurs on one side only. H2
••Tapered center plate design creates smooth transition.
H1
••Meets ADA requirements.
W

471 Series - Surface Mount


471-A01 Floor/Floor

Expansion Joint Systems


(4" (100mm) system shown)
S
H2

W
471-A02 Floor/Wall SS
••Surface mount ideal for retrofits, additions and renovations. (4" (100mm) system shown) 1 78 ”
[48MM]
••Flooring may be inserted under plate for reduced sightline.
••Exposed fastener makes maintenance easier. H1
H1
W
W

••Tapered center plate design creates smooth transition.

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
461-A01-075 3" 76 1 1/2" 38 1/4" 6 9 1/4" 235 4" 102 1 1/2" 38 3/4" 19
461-A01-100 4" 102 1 1/2" 38 1/4" 6 10 1/4" 260 4" 102 2" 51 1" 25
461-A01-150 6" 152 1 1/2" 38 5/16" 8 15 1/4" 387 5 1/4" 133 3" 76 1 1/2" 38
461-A01-200 8" 203 1 1/2" 38 5/16" 8 19 5/8" 498 7" 178 4" 102 2" 51
Floor to Floor 471-A01-075 3" 76 * * 1/4" 6 10 1/2" 267 * * 1 1/2" 38 3/4" 19
471-A01-100 4" 102 * * 1/4" 6 11 7/8" 302 * * 2" 51 1" 25
471-A01-150 6" 152 * * 5/16" 8 16 7/8" 430 * * 3" 76 1 1/2" 38
471-A01-200 8" 203 * * 5/16" 8 21 3/8" 543 * * 4" 102 2" 51
471-A02-075 3" 76 * * 1/4" 6 6 3/4" 171 * * 3/4" 19 3/4" 19
471-A02-100 4" 102 * * 1/4" 6 7 7/8" 200 * * 1" 25 1" 25
Floor to Wall 471-A02-150 6" 152 * * 5/16" 8 11 1/2" 292 * * 1 1/2" 38 1 1/2" 38
471-A02-200 8" 203 * * 5/16" 8 14 3/4" 375 * * 2" 51 2" 51

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 23


Floor Systems - Heavy Duty

700 Series systems meet Heavy Duty loading % of MOVEMENT VAPOR BARRIER
scenarios in many environments such as ±50% optional
open structures, stadium venues, parking
structures, airports and warehouses. JOINT WIDTH fire rated
1" (25mm) – 12" (300mm) optional

721 | 723 | 725 Series

••Highly modifiable system capable of meeting many


loading scenarios.
••Heavy Duty bearing system.
••Engineered for pneumatic and solid tires.
••Stainless steel plate available on 723 system.
••Stainless steel plate and wings available on 725 system.

721-A01 Floor/Floor
(4" (100mm) system shown)
SS
H1
H1

W
W
723-A01 Floor/Floor 725-A01 Floor/Floor
(4" (100mm) system shown) (4" (100mm) system shown)
Aluminum
S
Stainless Steel Aluminum Stainless Steel
S
Wing Plate Stainless Steel Stainless Steel
Coverplate Wing Plate Wing Plate
Coverplate Wing Plate

H1H1
H1H1

W
W W

W H1 S B Movement +/-
System 725-A01-100
Application
723-A01-100

(721,723,725) Joint Width Frame Height 1 Sightline Blockout Horizontal Vertical


US mm US mm US mm US mm US mm US mm
721-A01-050 2" 51 1 5/8" 40 8 1/2" 216 3 3/4" 95 1"" 25 1" 25
721-A01-100 4" 102 1 5/8" 40 12 1/2" 318 4 3/4" 121 2" 51 2" 51
Floor to
721-A01-150 6" 152 1 5/8" 40 16 1/2" 406 5 3/4"" 146 3" 76 3" 76
Floor
721-A01-200 8" 203 1 5/8" 40 20 1/2" 502 6 3/4" 171 4" 102 4" 102
721-A01-300 12" 305 1 5/8" 40 28 1/2" 705 8 3/4" 222 6" 152 6" 152
721-A02-050 2" 51 1 5/8" 40 5 1/4" 133 3 3/4" 95 1/2" 13 1/2" 13
721-A02-100 4" 102 1 5/8" 40 8 1/4" 210 4 3/4" 121 1" 25 1" 25

Floor to Wall 721-A02-150 6" 152 1 5/8" 40 11 1/4" 286 5 3/4" 146 1 1/2" 38 1 1/2" 38
721-A02-200 8" 203 1 5/8" 40 14 1/4" 362 6 3/4" 171 2" 51 2" 51
721-A02-300 12" 305 1 5/8" 40 20 1/4" 515 8 3/4" 222 3" 76 3" 76

Larger sizes available

24 800.222.5556 | Installation Hotline: 866.ezinpro


741-A01 Floor/Floor
741 Series (4" (100mm) system shown)

H1

••Cost-effective option for a high load bearing system.


••Engineered for pneumatic and solid tires. W
••Stainless steel plate available.
••System designed to be installed over finished flooring.

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
741-A01-050 2" 50 1" 25 * * 8 1/2" 216 3 1/4" 83 1" 25 1" 25
Floor to Floor 741-A01-100 4" 100 1" 25 * * 11 3/4" 298 3 1/4" 83 2" 50 2" 50
741-A01-150 6" 150 1" 25 * * 14 1/2" 368 3 1/4" 83 3" 75 3" 75

Other sizes and finishes available

757 | 767 Series

757-A01 Floor/Floor
(8" (200mm) system shown)
SS

H1
H1

••Flush, constant leveling, low profile design Optional vapor barrier shown
W

Expansion Joint Systems


allows for a smooth transition when W
traversing the joint system.
••Optional integral vapor barrier slides directly
767-A01 Floor/Floor
into frame for easy installation. (8" (200mm) system shown)
••767 series allows for additional hardware S
anchorage points in environments with high
vibration or vehicular loading. H1
••Utilizes elastomeric concrete system nosing
to reduce vibrations imposed on the system
resulting in extended-life of the components. Optional vapor barrier available W
••Mill finish standard.

W H1 H2 S B Movement +/-
System
Application Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
(757, 767)
US mm US mm US mm US mm US mm US mm US mm
757-A01-100 4" 100 2" 51 * * 13 1/2" 222 6 5/8" 102 2" 51 3/4" 152
Floor to Floor 757-A01-150 6" 150 2" 51 * * 15 1/2" 394 6 5/8" 206 3" 76 1 1/2" 178
757-A01-200 8" 200 2" 51 * * 17 1/2" 445 6 5/8" 206 4" 102 2" 203

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 25


Floor Systems - Heavy Duty Seismic

787 Series

Industry unique, low


profile design reduces
the lateral impact (shear
forces) encountered with
repeated vehicular traffic.

Tapered plate and frames


provide a seamless
design that constantly
levels itself and maintains Heavy Duty design uses a thick,
a flush condition. high strength centering bar and
spring assembly to resist vibrations, Serrated cover plate for
extending joint lifecycle. added slip resistance.

••Seismic capable system designed to meet the needs of an open


% of MOVEMENT VAPOR BARRIER structure and vehicular loading scenarios.
25%-50% optional
••1" [32mm] frame depth ensures no interference in rebar/cabling
JOINT WIDTH structures with concrete decks.
fire rated
4"-12" optional ••Integral high durometer seal acts as a noise dampener and deters water
from slipping beneath plate.
••Mill finish standard.

787-A01 Floor/Floor
787-A02 Floor/Wall
(4" (100mm) system shown)
S (4" (100mm) system shown)
S

H1 H1

W W
W H S B Movement +/-
Application System Joint Width Frame Height Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm
787-A01-100 4" 100 1" 25 13 1/2" 342 6" 152 2" 51 1" 25
787-A01-150 6" 150 1" 25 16 1/2" 419 6 1/2" 165 3" 76 1 1/2" 38
Floor to Floor 787-A01-200 8" 200 1" 25 18 1/2" 470 6 1/2" 165 4" 102 2" 51
787-A01-250 10" 250 1" 25 24 1/2" 622 8 1/2" 216 5" 127 2 1/2" 64
787-A01-300 12" 300 1" 25 26 1/2" 673 8 1/2" 216 6" 152 3" 76
787-A02-100 4" 100 1" 25 8 3/4" 222 6" 152 1" 25 1" 25
787-A02-150 6" 150 1" 25 11 1/4" 286 6 1/2" 165 1 1/ 2" 76 1 1/2" 38
Floor to Wall 787-A02-200 8" 200 1" 25 13 1/4" 337 6 1/2" 165 2" 102 2" 51
787-A02-250 10" 250 1" 25 17 1/4" 438 8 1/2" 216 2 1/2" 127 2 1/2" 64
787-A02-300 12" 300 1" 25 19 1/4" 489 8 1/2" 216 3" 152 3" 76

Different configurations and larger joint sizes available

26 800.222.5556 | Installation Hotline: 866.ezinpro


Floor Systems - Standard

••Mill finish standard.


The 800 Series is our most cost effective product line that is suitable
for many joint sizes in a variety of applications.

801 Series

A01 Floor/Floor A02 Floor/Wall


(1" (25mm) system shown) (2" (51mm) system shown)
S
S
H1

W
••Beveled edges provide pedestrian safety.
H1
••Pre-drilled, counter-sunk holes for easy
installation. W
••Available in stainless steel and other
custom finishes.

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
801-A01-025 1" 25 1/8" 3 * * 4 1/8" 105 * * 1/2" 13 * *
Floor to Floor 801-A01-050 2" 51 1/8" 3 * * 5 5/8" 143 * * 1" 25 * *
801-A02-025 1" 25 1/8" 3 * * 1 1/2" 38 * * 1/2" 13 * *
Floor to Wall 801-A02-050 2" 51 1/8" 3 * * 3" 76 * * 1" 25 * *

Additional sizes and finishes available

804 Series

Expansion Joint Systems


A01 Floor/Floor A02 Floor/Wall
(1" (25mm) system shown) (1" (25mm) system shown)

S
H1

••Spring clip design for easy on-site installation. W


••A07 Condition offers finish options on page 7.
••Designed to be installed over finished flooring.

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
804-A01-025 1" 25 1/8" 4 * * 3" 76 * * 1/4" 6 1/8" 3
Floor to Floor 804-A01-038 1 1/2" 38 1/8" 4 * * 3" 76 * * 3/8" 10 1/8" 3
804-A01-050 2" 51 1/8" 4 * * 4 1/2" 114 * * 1/2" 13 1/8" 3
804-A02-025 1" 25 1/8" 4 * * 2" 50 * * 1/4" 6 1/8" 3
Floor to Wall 804-A02-038 1 1/2" 38 1/8" 4 * * 2" 50 * * 3/8" 10 1/8" 3
804-A02-050 2" 51 1/8" 4 * * 3 1/4" 83 * * 1/2" 13 1/8" 3

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 27


Floor Systems - Standard Cover Plate

806 Series

Pre-drilled, counter-sunk
holes for easy installation
Designed for uneven slab
conditions and vertical Designed to be installed
shear conditions. over finished flooring.

A02 Floor/Wall
(2" (51mm) system shown)
A01 Floor/Floor S
(2" (51mm) system shown)

••Moderate loading capabilities. S


H1
••Unlimited lateral shear movement.
••Mill finish standard.
H1
W
W
W H1 H2 S B1 Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
806-A01-050 2" 51 1/4" 6 * * 7" 178 * * 1" 25 * *
806-A01-100 4" 102 1/4" 6 * * 10 1/2" 267 * * 2" 51 * *
Floor to Floor 806-A01-150 6" 152 1/4" 6 * * 13" 330 * * 3" 76 * *
806-A01-200 8" 203 5/16" 8 * * 17" 432 * * 4" 102 * *
806-A01-300 12" 305 5/16" 8 * * 23" 584 * * 6" 152 * *
806-A02-050 2" 51 1/4" 6 * * 4" 102 * * 1" 25 * *
806-A02-100 4" 102 1/4" 6 * * 7 1/2" 191 * * 2" 51 * *
Floor to Wall 806-A02-150 6" 152 1/4" 6 * * 10" 254 * * 3" 76 * *
806-A02-200 8" 203 5/16" 8 * * 13" 330 * * 4" 102 * *
806-A02-300 12" 305 5/16" 8 * * 19" 483 * * 6" 152 * *

28 800.222.5556 | Installation Hotline: 866.ezinpro


802 | 807 Series
A01 Floor/Floor H1 S H2
(2" (51mm) system shown)

W
A02 Floor/Floor
(2" (51mm) system shown)
1 58 “
S
S

[41mm]

••Design accommodates various flooring H2H2

thicknesses and finishes from carpet to VCT.


••Overlap design reduces sightline to only 2".
••Mill finish standard.
W
W

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
802-A01-050/3 2" 51 1/8" 3 1/8" 4 2" 51 * * 1/2" 13 * *
802-A01-050/6 2" 51 1/8" 3 1/4" 6 2" 51 * * 1/2" 13 * *
802-A01-050/10 2" 51 1/8" 3 3/8" 10 2" 51 * * 1/2" 13 * *
Floor to Floor 807-A01-050 2" 50 * * 1/8,3/8" 3,10 2" 50 * * 1" 25 1" 25
807-A01-075 3" 75 * * 1/8,3/8" 3,10 2" 50 * * 1" 25 1" 25
807-A01-100 4" 100 * * 1/8,3/8" 3,10 2" 50 * * 1" 25 1" 25
807-A01-150 6" 150 * * 1/8,3/8" 3,10 2" 50 * * 1" 25 1" 25
807-A02-050 2" 50 * * 1/8,3/8" 3,10 2" 50 * * 1" 25 1" 25
807-A02-075 3" 75 * * 1/8,3/8" 3,10 2" 50 * * 1" 25 1" 25
Floor to Wall 807-A02-100 4" 100 * * 1/8,3/8" 3,10 2" 50 * * 1" 25 1" 25
807-A02-150 6" 150 * * 1/8,3/8" 3,10 2" 50 * * 1" 25 1" 25

808 Series

A01 Floor/Floor
(2" (51mm) system shown)
S

H1
••Beveled edges and serrated plates provide traction
for pedestrian safety.
••Pre-drilled, counter-sunk holes for easy installation.
W

Expansion Joint Systems


••Designed to be installed over finished flooring.
••Mill finish standard.

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal
US mm US mm US mm US mm US mm US mm
808-A01-025 1" 25 1/4" 6 * * 6" 152 * * 1/2" 13
808-A01-050 2" 51 1/4" 6 * * 6" 152 * * 1" 25
Floor to Floor 808-A01-075 3" 76 1/4" 6 * * 10" 254 * * 1 1/2" 38
808-A01-100 4" 102 1/4" 6 * * 10" 254 * * 2" 51

University of Wisconsin Platteville, Platteville, WI


300 Series | 811 Series

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 29


Floor Systems - Narrow Sightline and Pan Systems

Virtually eliminates wide sightlines. Configurations % of MOVEMENT VAPOR BARRIER


±50% - 100% optional
allow for use in new construction or renovations.
These multifunctional designs provide alignment for JOINT WIDTH fire rated
floor and corner conditions. 2" (25mm) – 12" (300mm) optional

316 Series Single Sightline


A01 Floor/Floor
S
(2" (51mm) system shown)
H1

••Reduces 2-4" (102mm) gaps to only a 1" (25mm)


single sightline. A02 Floor/Wall
(2" (51mm) system shown) S
••Multifunctional design provides for alignment of
system sightlines at continuous Floor-to-Floor and
Floor-to-Wall conditions.
••Specifically designed for continuous flooring types
such as carpeting or vinyl sheet.
••Rated for high pedestrian load. H1
H1
W
W B 2"
[50mm]
min. blockout

W H1 S B Movement +/-
Application System Joint Width Frame Height 1 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm
316-A01-050 2" 51 2" 51 1" 25 4 1/2" 114 1" 25 1" 25
Floor to Floor 316-A01-075 3" 76 2" 51 1" 25 4 1/2" 114 1 1/2" 38 1 1/2" 38
316-A01-100 4" 102 2" 51 1" 25 4 1/2 114 1 1/2" 38 1 1/2" 38
316-A02-050 2" 51 2" 51 1" 25 4 1/2" 114 1" 25 1" 25
Floor to Wall 316-A02-075 3" 76 2" 51 1" 25 4 1/2" 114 1 1/2" 38 1 1/2" 38
316-A02-100 4" 102 2" 51 1" 25 4 1/2 114 1 1/2" 38 1 1/2" 38

30 800.222.5556 | Installation Hotline: 866.ezinpro


501 Series - "Pop-up" Pan System
Central pan rides up the frame under seismic movement
then returns to position to maintain egress routes.

501-A01-100-POPPED

A01 Floor/Floor
••The combined use of centerbars and compression (4" (100mm) system shown) S H2 S
spring components correctly reposition the pan after
seismic movement. H1
••The 501 system can reduce expansion joints of widths up to
8" (203mm) down to just two 1/2" (13mm) reveals.
••Ideal for carpeted areas where slim sightlines on larger
joints are required for aesthetic reasons.
••Floor-to-Floor applications only. W

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
501-A01-050 2" 51 2" 51 1 1/2" 38 1" 25 5" 127 4 3/8" 110 2" 6
501-A01-075 3" 76 2" 51 1 1/2" 38 1" 25 5" 127 4 3/8" 110 3" 13
Floor to Floor 501-A01-100 4" 102 2" 51 1 1/2" 38 1" 25 5" 127 4 3/8" 110 4" 19
501-A01-150 6" 152 2" 51 1 1/2" 38 1" 25 5" 127 4 3/8" 110 6" 25
501-A01-200 8" 203 2" 51 1 1/2" 38 1" 25 5" 127 7 1/2" 191 8" 38

502 Series - "Hinged" Pan System


A01 Floor/Floor
(4" (100mm) system shown) Hinged pan rides up the canted frame under
SS SS seismic movement then returns to position to
maintain egress routes.
H1

H2
H2

Expansion Joint Systems


Ideal for floor finishes with increased B
B W
W
depths such as marble, granite, A02 Floor/Wall S
limestone and paver systems. (4" (100mm) system shown)

••System provides for unlimited S


lateral movement. H1
••Pan profile provides a vertical surface
to abut tile against, eliminating the H
need to bevel flooring edges.
••Reveals align for Floor-to-Floor and
Floor-to-Wall applications.
B W
W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
502-A01-050 2" 51 2" 51 5 1/2" 139 1" 25 9 3/8" 238 1" 25 1" 25
502-A01-100 4" 102 2" 51 5 1/2" 139 1" 25 7 3/8" 187 2" 51 2" 51
Floor to Floor 502-A01-150 6" 152 2" 51 5 1/2" 139 1" 25 8 3/8" 222 3" 76 3" 76
502-A01-200 8" 203 2" 51 5 1/2" 139 1" 25 9 3/8" 238 4" 102 4" 102
502-A02-050 2" 51 2" 51 5 1/2" 139 1" 25 9 3/8" 238 1" 25 1" 25
502-A02-100 4" 102 2" 51 5 1/2" 139 1" 25 7 3/8" 187 2" 51 2" 51
Floor to Wall 502-A02-150 6" 152 2" 51 5 1/2" 139 1" 25 8 3/8" 222 3" 76 3" 76
502-A02-200 8" 203 2" 51 5 1/2" 139 1" 25 9 3/8" 238 4" 102 4" 102

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 31


Project Profile:
The Exploratorium® at Pier 15
San Francisco, California
Architect:
Esherick Homey Dodge & Davis
San Francisco, California

General Contractor:
Nibbi Brothers
San Francisco, California

Expansion Joint Contractor:


Expansion Specialties, Inc.
Henderson, Nevada

The Project
The $220 million Exploratorium is located
in the heart of San Francisco’s waterfront.
Hands-on exhibits explore biology, physics,
listening, cognition, visual perception,
social behavior and the environment.

The Challenge The Solution


After breaking ground in October 2010, the first phase JointMaster® provided the entire expansion joint and
of this project included refurbishing and seismically fire barrier package for the Exploratorium project.
upgrading the historic Pier 15 – spanning the length of Almost 1,500 linear feet of interior and exterior
almost three football fields over the water. Engineers seismic expansion joints are used throughout the
drove piles underneath the bay to replace, repair and/ building. Joint widths varied from 8" to as wide as 27".
or seismically upgrade, hundreds of dilapidated pilings Of that, nearly 95 percent of the joint systems were
and the substructure, some which date to the early custom designed and built, including several joints
20th century. incorporating 3/8" thick stainless steel diamond plate.
The built space of 330,000 square feet includes Because the Exploratorium is built over the water,
quintessential Exploratorium exhibits in four galleries; designers specified Kynar® coatings on many of the joint
space for professional teacher training, after-school systems to fight salt-water effects. In addition, waterproof
programs, educational camps and lifelong learning; a fire barrier was incorporated where specified.
theater; the Exploratorium store; and a café. And in the spirit and style of the Exploratorium, there
is a display dedicated to the expansion joints used,
helping visitors and students understand a building’s
constant battle with Mother Nature, and how
expansion joints help a building withstand thermal
and seismic movement.

32 800.222.5556 | Installation Hotline: 866.ezinpro


Wall and Ceiling Systems

JointMaster® offers a comprehensive line of Wall and Ceiling Expansion Joint Systems with
recessed and drywall options for both thermal and seismic conditions.

Expansion Joint Systems

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 33


Wall and Ceiling - Drywall Finishes

••Standard and custom seal colors available, see pages 66-67.

% of MOVEMENT VAPOR BARRIER


Cost effective systems with simple installations ±25% optional
assist in controlling project budgets.
JOINT WIDTH fire rated
1" (25mm) – 3" (76mm) optional

112 Series - Recessed Mount for 5/8" (16mm) Drywall

A07 Wall/Wall Ceiling/Ceiling A09 Wall/Corner Wall/Ceiling


(2" (51mm) system shown) (2" (51mm) system shown)
••Snap-in frame accepts 5/8" H1
(16mm) drywall. No finish
required, saving on site
installation costs.
W
••Clear anodized aluminum S
for a decorative finish. W S
••Available finish options, see
page 66-67.

H1

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
112-A07-025 1" 25 5/8" 16 * * 2" 51 * * 1/4" 6 1/4" 6
Wall to Wall 112-A07-038 1 1/2" 38 5/8" 16 * * 2 7/16" 62 * * 3/8" 10 3/8" 10
5/8" 2 7/8" 1/2" 1/2"
Ceiling to Ceiling 112-A07-050 2" 51
5/8"
16 * * 73 * *
3/4"
13
3/4"
13
112-A07-075 3" 76 16 * * 4" 102 * * 19 19
112-A09-025 1" 25 5/8" 16 * * 1 1/2" 38 * * 1/4" 6 1/4" 6
Wall to Corner 112-A09-038 1 1/2" 38 5/8" 16 * * 1 15/16" 49 * * 3/8" 10 3/8" 10
5/8" 2 3/8" 1/2" 1/2"
Wall to Ceiling 112-A09-050 2" 51
5/8"
16 * * 60 * * 13 13
112-A09-075 3" 76 16 * * 3 3/8" 86 * * 3/4" 19 3/4" 19

113 Series - Surface Mount


A07 Wall/Wall Ceiling/Ceiling A09 Wall/Corner Wall/Ceiling
(2" (51mm) system shown) (2" (51mm) system shown)

W S
W S

••Frame allows for finish with joint compound or wall covering.


••Dual durometer seal provides secure fit and optimal flexibility.
••Sightline reduced to width of flexible seals.

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
113-A07-025 1" 25 * * * * 1" 25 * * 1/4" 6 1/4" 6
Wall to Wall 113-A07-038 1 1/2" 38 * * * * 1 1/2" 36 * * 3/8" 10 3/8" 10
Ceiling to Ceiling 113-A07-050 2" 51 * * * * 2" 47 * * 1/2" 13 1/2" 13
113-A07-075 3" 76 * * * * 3" 76 * * 3/4" 19 3/4" 19
113-A09-025 1" 25 * * * * 1" 25 * * 1/4" 6 1/4" 6
Wall to Corner 113-A09-038 1 1/2" 38 * * * * 1 1/2" 36 * * 3/8" 10 3/8" 10
Wall to Ceiling 113-A09-050 2" 51 * * * * 2" 47 * * 1/2" 13 1/2" 13
113-A09-075 3" 76 * * * * 3" 73 * * 3/4" 19 3/4" 19

34 800.222.5556 | Installation Hotline: 866.ezinpro


101 Recessed Mount
A07 Wall/Wall Ceiling/Ceiling A09 Wall/Corner Wall/Ceiling
(2" (51mm) system shown) (2" (51mm) system shown)

H2 H2
H2

W S

••Recessed mount frame for minimal sightline. W


W SS
••Dual durometer seal provides secure fit and optimal
flexibility.
••Adaptable to any 5/8" (16mm) wall and ceiling finish,
including drywall, plaster and tile.
••Snap-fit design allows for easy on-site assembly.

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
101-A07-025 1" 25 3/4" 19 5/8" 16 1" 25 * * 1/4" 6 1/4" 6
Wall to Wall 101-A07-038 1 1/2" 38 3/4" 19 5/8" 16 1 7/16" 36 * * 3/8" 10 3/8" 10
Ceiling to Ceiling 101-A07-050 2" 51 3/4" 19 5/8" 16 1 7/8" 47 * * 1/2" 13 1/2" 13
101-A07-075 3" 76 3/4" 19 5/8" 16 2 7/8" 73 * * 3/4" 19 3/4" 19
101-A09-025 1" 25 3/4" 19 5/8" 16 1" 25 * * 1/4" 6 1/4" 6
Wall to Corner 101-A09-038 1 1/2" 38 3/4" 19 5/8" 16 1 7/16" 36 * * 3/8" 10 3/8" 10
Wall to Ceiling 101-A09-050 2" 51 3/4" 19 5/8" 16 1 7/8" 47 * * 1/2" 13 1/2" 13
101-A09-075 3" 76 3/4" 19 5/8" 16 2 7/8" 73 * * 3/4" 19 3/4" 19

821 Acoustical Ceiling

V24 Ceiling/Ceiling
(2" (51mm) system shown)

Expansion Joint Systems


S

V23 Ceiling/Wall
(2" (51mm) system shown)

••Pop-rivet design allows for easy on-site assembly.


••Co-extruded pleated vinyl allows fluid movement.
••Bright white seal only.
S

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
821-V24-025 1" 25 * * * * 1" 25 * * 1/2" 13 1/2" 13
Wall to Wall 821-V24-050 2" 51 * * * * 2" 51 * * 1" 25 1/2" 13
1/2" 1/2"
Ceiling to Ceiling 821-V23-025 1" 25 * * * * 1" 25 * * 13
1/2"
13
821-V23-050 2" 51 * * * * 2" 51 * * 1" 25 13
Standard color bright white

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 35


Wall and Ceiling - Drywall Acoustical, Flush Mount

••Standard and custom seal colors available, see pages 66-67.


Pleated Santoprene® seal design allows for fluid,
% of MOVEMENT VAPOR BARRIER
thermal and seismic movement during joint ±50% - 100% optional (114)
expansion, contraction, lateral and out-of-
plane movement. JOINT WIDTH fire rated
2" (50mm) – 6" (150mm) optional (144 & 611)

114 Series - Drywall


A07 Wall/Wall Ceiling/Ceiling A09 Wall/Corner Wall/Ceiling
(3" (75mm) system shown) (2" (51mm) system shown) W

••Frame allows for finish


with joint compound
or wall covering to W S
minimize sightline.

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
114-A07-050 2" 51 * * * * 2 1/8" 54 * * 1" 25 1" 25
Wall to Wall 114-A07-075 3" 76 * * * * 3 1/16" 78 * * 1 1/2" 38 1 1/2" 38
Ceiling to Ceiling 114-A07-100 4" 102 * * * * 4 1/8" 105 * * 2" 51 2" 51
114-A07-150 6" 152 * * * * 6 1/8" 156 * * 3" 76 3" 76
114-A09-050 2" 51 * * * * 2" 51 * * 1" 25 1" 25
Wall to Corner 114-A09-075 3" 76 * * * * 3" 76 * * 1 1/2" 38 1 1/2" 38
Wall to Ceiling 114-A09-100 4" 102 * * * * 4" 102 * * 2" 51 2" 51
114-A09-150 6" 152 * * * * 6" 152 * * 3" 76 3" 76

115 Series - Acoustical Ceiling

A24 Ceiling/Ceiling A18 Wall/Ceiling


(2" (51mm) system shown) (2" (51mm) system shown)

••Frame pop rivets to T-Bar profile in suspended


ceiling system. W W
••Seal design allows for seismic movement.

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
115-A24-050 2" 51 * * * * 2" 51 * * 1" 25 1" 25
Wall to Wall 115-A24-075 3" 76 * * * * 3" 76 * * 1 1/ 2" 38 1 1/ 2" 38
Ceiling to Ceiling 115-A24-100 4" 102 * * * * 4" 102 * * 2" 51 2" 51
115-A18-050 2" 51 * * * * 2" 51 * * 1" 25 1" 25
Wall to Corner 115-A18-075 3" 76 * * * * 3" 76 * * 1 1/ 2" 38 1 1/ 2" 38
Wall to Ceiling 115-A18-100 4" 102 * * * * 4" 102 * * 2" 51 2" 51

36 800.222.5556 | Installation Hotline: 866.ezinpro


611 Series - Flush Mount
A07 Wall/Wall Ceiling/Ceiling A09 Wall/Corner Wall/Ceiling
(2" (51mm) system shown) (4" (102mm) system shown)

••Sightline reduced to width


of flexible seal.
••Seals available in standard W S
and custom colors see W S
pages 66-67.

H1 H1
W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
611-A07-050 2" 51 2 3/8" 60 * * 2" 51 * * 1" 25 1" 25
Wall to Wall 611-A07-075 3" 76 2 3/8" 60 * * 3" 76 * * 1 1/2" 38 1 1/ 2" 38
Ceiling to Ceiling 611-A07-100 4" 102 2 3/8" 60 * * 4" 102 * * 2" 51 2" 51
611-A07-150 6" 152 2 3/8" 60 * * 6" 152 * * 3" 76 3" 76
611-A09-050 2" 51 2 3/8" 60 * * 2" 51 * * 1" 25 1" 25
Wall to Corner 611-A09-075 3" 76 2 3/8" 60 * * 3" 76 * * 1 1/2" 38 1 1/ 2" 38
Wall to Ceiling 611-A09-100 4" 102 2 3/8" 60 * * 4" 102 * * 2" 51 2" 51
611-A09-150 6" 152 2 3/8" 60 * * 6" 152 * * 3" 76 3" 76

612 Series - Flush Mount


A07 Wall/Wall Ceiling/Ceiling A09 Wall/Corner Wall/Ceiling
(12" (300mm) system shown) (10" (250mm) system shown)

W S W S

Expansion Joint Systems


••Industry-unique Santoprene® seal design
allows for fluid seismic movement during joint
expansion and contraction.
••Field heat-weldable Santoprene seals for weather
tight seams and crisp transitions.
••Seal walls are among the thickest in the industry
allowing our product to be used in soffits and
corridor ceilings with no sagging.
H1
H1
W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
612-A07-200 8" 200 3" 75 * * 8" 200 * * 4" 102 4" 102
612-A07-250 10" 250 3" 75 * * 10" 250 * * 5" 127 5" 127
Wall to Wall 612-A07-300 12" 300 3" 75 * * 12" 300 * * 6" 152 6" 152
612-A07-450 18" 450 3" 75 * * 18" 450 * * 9" 229 9" 229
612-A07-600 24" 600 3" 75 * * 24" 600 * * 12" 305 12" 305
612-A09-200 8" 200 3" 75 * * 8" 200 * * 4" 102 4" 102
612-A09-250 10" 250 3" 75 * * 10" 250 * * 5" 127 5" 127
Wall to Corner 612-A09-300 12" 300 3" 75 * * 12" 300 * * 6" 152 6" 152
612-A09-450 18" 450 3" 75 * * 18" 450 * * 9" 229 9" 229
612-A09-600 24" 600 3" 75 * * 24" 600 * * 12" 305 12" 305
Larger sizes available

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 37


Wall and Ceiling - Drywall Flush Mount

Accommodates large joint widths with narrow ••Center bar and compression spring assembly correctly reposition
sightlines for minimal aesthetic interruption. pan after seismic movement.
••Seal barbs provide secure engagement in frame, making
installation easier.
% of MOVEMENT VAPOR BARRIER ••Face of seal resists sagging and remains flat in ceiling conditions.
±50% optional ••Field heat-weldable Santoprene® seals for weather
tight transitions.
JOINT WIDTH fire rated •• Standard and custom seal colors available, see pages 66-67.
8" (200mm)-24" (600m) optional

221 Series - Aluminum Plate


A07 Wall/Wall Ceiling/Ceiling A09 Wall/Corner Wall/Ceiling H1
(8" (200mm) system shown) (8" (200mm) system shown)

W
H1 1 3/4”
[44mm]
S
W
W
••Intended for use on smaller joint sizes
where durability is required.
••Easy installation and maintenance.
••Anodized finish standard.

W H1 S B Movement +/-
Application System Joint Width Frame Height 1 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm
221-A07-050 2" 51 5/8" 16 4 7/8" 124 1 1/2" 13 1” 25 1” 25
221-A07-100 4" 102 5/8" 16 9 3/8" 238 2 3/4" 70 2” 51 2” 51
221-A07-150 6" 152 5/8" 16 11 3/8" 289 2 3/4" 70 3” 75 3” 75
Wall to Wall 221-A07-200 8" 200 5/8" 16 18" 457 4 1/2" 114 4” 102 4” 102
221-A07-250 10" 250 5/8" 16 21" 533 4 1/2" 114 5” 125 5” 125
221-A07-300 12" 300 5/8" 16 24" 609 4 1/2" 114 6” 152 6” 152
221-A09-050 2" 51 5/8" 16 3 1/2" 89 1 1/2" 13 1/4" 6 1/4" 6
221-A09-100 4" 102 5/8" 16 6 5/8" 168 2 3/4" 70 1/2" 13 1/2" 13
221-A09-150 6" 152 5/8" 16 8 5/8" 219 2 3/4" 70 1/2" 13 1/2" 13
Wall to Corner 221-A09-200 8" 200 5/8" 16 13" 330 4 1/2" 114 2 51 2 51
221-A09-250 10" 250 5/8" 16 15 1/2" 394 4 1/2" 114 2 1/2" 64 2 1/2" 64
221-A09-300 12" 300 5/8" 16 18" 457 4 1/2" 114 3 76 3 76
Larger sizes available - Custom joints up to 30" available

38 800.222.5556 | Installation Hotline: 866.ezinpro


223 Series
A07 Wall/Wall Ceiling/Ceiling
(8" (200mm) system shown) W
W

••Flat seal allows for 25% thermal


movement. H1
H1
••3/8" (10mm) Drywall within
SS H2 S
S
center pan cover to be painted or
wall covered to reduce sightline. A09 Wall/Corner Wall/Ceiling
(8" (200mm) system shown) W
W
••Intended for use on joints
with a high degree of thermal
movement.
H1
H1
H2 S
S

W H1 S B Movement +/-
Application System Joint Width Frame Height 1 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm
223-A07-150 6" 152 5/8" 16 6" 150 * * 2" 51 2" 51
223-A07-200 8" 200 5/8" 16 6" 150 * * 2" 51 2" 51
223-A07-250 10" 250 5/8" 16 6" 150 * * 2" 51 2" 51
Wall to Wall 223-A07-300 12" 300 5/8" 16 6" 150 * * 2" 51 2" 51
223-A07-350 14" 350 5/8" 16 6" 150 * * 2" 51 2" 51
223-A07-400 16" 400 5/8" 16 6" 150 * * 2" 51 2" 51
223-A07-450 18" 450 5/8" 16 6" 150 * * 2" 51 2" 51
223-A09-150 6" 152 5/8" 16 3" 75 * * 1" 25 1" 25
223-A09-200 8" 200 5/8" 16 3" 75 * * 1" 25 1" 25
223-A09-250 10" 250 5/8" 16 3" 75 * * 1" 25 1" 25
Wall to Corner 223-A09-300 12" 300 5/8" 16 3" 75 * * 1" 25 1" 25
223-A09-350 14" 350 5/8" 16 3" 75 * * 1" 25 1" 25
223-A09-400 16" 400 5/8" 16 3" 75 * * 1" 25 1" 25
223-A09-450 18" 450 5/8" 16 3" 75 * * 1" 25 1" 25
Larger sizes available

233 Series - Drywall


••Flat seal allows for 25% thermal A07 Wall/Wall Ceiling/Ceiling H1
H1
(8" (200mm) system shown) 5 /8” (16mm)
movement prior to engaging W
W
center bar spring which allows
for the full 50% movement. SS

Expansion Joint Systems


••3/8" (10mm) Drywall within H2
center pan cover to be
SS SS
painted or wall covered
H2
to reduce sightline. A09 Wall/Corner Wall/Ceiling W
W
(8" (200mm) system shown)
••Intended for use on joints
with both thermal and seismic
capable needs.

W H1 S B Movement +/-
Application System Joint Width Frame Height 1 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm
233-A07-150 6" 152 5/8" 16 6" 150 * * 3" 76 3" 76
233-A07-200 8" 200 5/8" 16 6" 150 * * 4" 102 4" 102
233-A07-250 10" 250 5/8" 16 6" 150 * * 5" 127 5" 127
Wall to Wall 233-A07-300 12" 300 5/8" 16 6" 150 * * 6" 152 6" 152
233-A07-350 14" 350 5/8" 16 6" 150 * * 7" 178 7" 178
233-A07-400 16" 400 5/8" 16 6" 150 * * 8" 203 8" 203
233-A07-450 18" 450 5/8" 16 6" 150 * * 9" 229 9' 229
233-A09-150 6" 152 5/8" 16 3" 75 * * 1 1/2" 38 1 1/2" 38
233-A09-200 8" 200 5/8" 16 3" 75 * * 2 51 2 51
233-A09-250 10" 250 5/8" 16 3" 75 * * 2 1/2" 64 2 1/2" 64
Wall to Corner 233-A09-300 12" 300 5/8" 16 3" 75 * * 3 76 3 76
233-A09-350 14" 350 5/8" 16 3" 75 * * 3 1/2" 89 3 1/2" 89
233-A09-400 16" 400 5/8" 16 3" 75 * * 4 102 4 102
233-A09-450 18" 450 5/8" 16 3" 75 * * 4 1/2" 114 4 1/2" 114
Larger sizes available. Custom size joints of 30"+ available.

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 39


Wall and Ceiling - Drywall Flush Mount

243 Series - Drywall


••Pleated seal allows for 50% W
movement within system prior to A07 Wall/Wall Ceiling/Ceiling
engaging center bar spring. (8" (200mm) system shown) H1
H1
••Ideal for environments where S H2 S
a high degree of both thermal
and seismic movement joint W
fluctuation is expected. A09 Wall/Corner Wall/Ceiling
(8" (200mm) system shown)
••3/8" (10mm) Drywall within
center pan cover to be painted or H1
wall covered to reduce sightline.
H2 S
W H1 S B Movement +/-
Application System Joint Width Frame Height 1 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm
243-A07-150 6" 152 5/8" 16 6" 150 * * 3” 76 3” 76
243-A07-200 8" 200 5/8" 16 8" 200 * * 4” 102 4” 102
243-A07-250 10" 250 5/8" 16 10" 250 * * 5” 127 5” 127
Wall to Wall 243-A07-300 12" 300 5/8" 16 12" 300 * * 6” 152 6” 152
243-A07-350 14" 350 5/8" 16 12" 300 * * 7” 178 7” 178
243-A07-400 16" 400 5/8" 16 12" 300 * * 8” 203 8” 203
243-A07-450 18" 450 5/8" 16 12" 300 * * 9” 229 9” 229
243-A09-150 6" 152 5/8" 16 3" 75 * * 1 1/2" 38 1 1/2" 38
243-A09-200 8" 200 5/8" 16 4" 100 * * 2 51 2 51
243-A09-250 10" 250 5/8" 16 5" 125 * * 2 1/2" 64 2 1/2" 64
Wall to Corner 243-A09-300 12" 300 5/8" 16 6" 150 * * 3 76 3 76
243-A09-350 14" 350 5/8" 16 6" 150 * * 3 1/2" 89 3 1/2" 89
243-A09-400 16" 400 5/8" 16 6" 150 * * 4 102 4 102
243-A09-450 18" 450 5/8" 16 6" 150 * * 4 1/2" 114 4 1/2" 114
Larger sizes available. Custom size joints of 30" available.

253 Series - Aluminum Plate


A07 Wall/Wall Ceiling/Ceiling
(8" (200mm) system shown)
w
W
••System allows for thermal and
seismic movement without H1
H1
the use of the Santoprene seals.
Ss
••Metal center pan can be A09 Wall/Corner Wall/Ceiling
fabricated to meet any joint width W
W (8" (200mm) system shown)
requirement. H1H1
5/8” (16mm)
••System can be utilized in exterior
environments as well as interior.
••Clear anodized finish standard.
SS
W H1 S B Thermal Movement +/- Seismic Movement +/-
Application System Joint Width Frame Height 1 Sightline Blockout Horizontal Vertical Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm US mm
253-A07-100 4" 102 5/8" 16 14 3/4" 375 * * 2" 51 2" 51 2" 51 2" 51
253-A07-150 6" 152 5/8" 16 17" 132 * * 2" 51 2" 51 3" 76 3" 76
Wall to Wall 253-A07-200 8" 200 5/8" 16 19" 483 * * 2" 51 2" 51 4" 102 4" 102
253-A07-250 10" 250 5/8" 16 21" 534 * * 2" 51 2" 51 5" 127 5" 127
253-A07-300 12" 300 5/8" 16 23" 585 * * 2" 51 2" 51 6" 152 6" 152
253-A09-100 4" 102 5/8" 16 9 1/4" 235 * * 1" 25 1" 25 1 25 1 25
253-A09-150 6" 152 5/8" 16 11 1/2" 289 * * 1" 25 1" 23 1 1/2" 38 1 1/2" 38
Wall to 253-A09-200 8" 200 5/8" 16 13 3/8" 340 * * 1" 25 1" 25 2 51 2 51
Corner 253-A09-250 10" 250 5/8" 16 16 1/8" 410 * * 1" 25 1" 25 2 1/2" 64 2 1/2" 64
253-A09-300 12" 300 5/8" 16 18 1/8" 460 * * 1" 25 1" 25 3 76 3 76

40 800.222.5556 | Installation Hotline: 866.ezinpro


Project Profile:
Owensboro Health
Owensboro, Kentucky
The Project
Owensboro Medical Health Center, Owensboro
Campus – Owensboro, Kentucky

HGA Architects designed the 780,000 square-


foot, 9-story tall Medical Center. The 145 acre
medical complex boasts a 447 bed inpatient
Tower, Diagnostics and Treatment Building,
Emergency Department, Women’s Center and
Heart Center.

The Challenge
Special treatment of the built environment was
the driving factor in many design decisions-
the goal was to create a warm, healing
environment that was welcoming to the
diverse patient population.

HGA consulted with a team of JointMaster®


engineers to explore expansion joint cover
options. The main focus was to reduce joint
systems sightlines to a bare minimum so as not
to detract from the richly finished aesthetic.
This was no small task considering expansion
joint structural gaps started at 4" on the

Expansion Joint Systems


ground floor and incrementally increased in
sizes up to 36" on the floor decks, interior walls,
exterior façade and roofs. In addition, there was mounting of drywall, so paint and wallcovering finishes continued
a requirement to design a 30" wide joint cover uninterrupted. Our wide, pleated seal products were utilized in the
that allowed for the exterior to be skinned in a ceilings as well.
continuously glazed curtain wall system as well The exterior system design was a true marvel with the development
as a stone veneer. The hurdles included heavy and release of the JointMaster 601 Stealth™ Series exterior system.
material weights, matching reveal patterns This allowed the architects to seamlessly incorporate façade
and incorporating an insulation system to help materials into the expansion cover. Spandrel glazing was mounted
reduce HVAC lifecycle costs. within the covers on the high profile, curvilinear veneer. Behind
The Solution the joint centerpan contained an Insulated Vapor Barrier system
JointMaster® met the challenge by developing maintaining an R-Value of 15+ while matching the vertical shear
seismic-capable joint covers that took on the movement capabilities of the Stealth cover.
adjacent finishes to mask their sheer size. JointMaster provided on-site support during construction to assist
Interior floor systems incorporated carpeting crews with installation. Systems utilized on this project include our
and ceramic tile. The interior walls contained 223 Floor joints, 243 Wall covers, 601 Stealth, 612 and 616 Series
recessed cover plates allowing for the Exteriors, as well as Foam Seals and the 975 Fire Barrier systems.

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 41


Wall and Ceiling - Glide Plate, Centering Bar

••Durably engineered systems hold up in interior and exterior


wall applications.
•• Provide crisp lines and shadows for a clean, finished look.
Clear anodized finish standard on these
systems. Provides a tough, durable finish that % of MOVEMENT VAPOR BARRIER
is easy to clean. ±50% optional

JOINT WIDTH fire rated


1" (25mm) – 12" (300mm) optional

300 Series - Glide Plate


A07 Wall/Wall Ceiling/Ceiling A09 Wall/Corner Wall/Ceiling
(2" (51mm) system shown) (2" (51mm) system shown)
H1 H1

S
W S
W
••5/8" recessed frame designed for inset into drywall installations
(can be surface mounted as well).
••Snap-fit cover designed for easy on-site assembly, no exposed
fasteners make system ideal for public/high abuse conditions.

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
300-A07-025 1" 25 5/8" 16 * * 5" 127 2" 51 1/2" 13 1/4" 6
300-A07-050 2" 51 5/8" 16 * * 6" 152 2" 51 1" 25 1/2" 13
Wall to Wall 300-A07-075 3" 76 5/8" 16 * * 9" 229 3" 76 1 1/2" 38 3/4" 19
Ceiling to Ceiling 300-A07-100 4" 102 5/8" 16 * * 10" 254 3" 76 2" 51 1" 25
300-A07-150 6" 152 5/8" 16 * * 14" 356 4" 102 3" 76 1 1/ 2" 38
300-A09-025 1" 25 5/8" 16 * * 2 3/8" 60 2" 51 1/4" 6 1/4" 6
300-A09-050 2" 51 5/8" 16 * * 3 3/8" 86 2" 51 1/2" 13 1/2" 13
Wall to Corner 300-A09-075 3" 76 5/8" 16 * * 5 3/8" 137 3" 76 3/4" 19 3/4" 19
Wall to Ceiling 300-A09-100 4" 102 5/8" 16 * * 6 3/8" 162 4" 102 1" 25 1" 25
300-A09-150 6" 152 5/8" 16 * * 9 3/8" 238 5" 127 1 1/2" 38 1 1/ 2" 38

42 800.222.5556 | Installation Hotline: 866.ezinpro


318 Series - Glide Plate
A07 Wall/Wall A09 Wall/Corner
(2" (51mm) system shown) (2" (51mm) system shown)

••Specifically designed for vinyl


wall covering, although can W W
be utilized in conjunction with
other finishes as well.
••Single narrow sightline
preferred by interior designers.

H1 H1

W H1 S B Movement +/-
Application System Joint Width Frame Height 1 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm
318-A07-050 2" 51 5/8" 16 1/8" 3 * * 1" 25 1/2" 13
Wall to Wall 318-A07-075 3" 76 5/8" 16 1/8" 3 * * 1 1/2" 38 3/4" 19
318-A07-100 4" 102 5/8" 16 1/8" 3 * * 2" 51 1" 25
318-A09-050 2" 51 5/8" 16 1/8" 3 * * 1" 13 1/2" 13
Wall to Corner 318-A09-075 3" 76 5/8" 16 1/8" 3 * * 1 1/2" 38 3/4" 19
318-A09-100 4" 102 5/8" 16 1/8" 3 * * 2" 51 1" 25

481 Series - Centering Bar


491 Series - Surface Mount Centering Bar
481 - A07 Wall/Wall Ceiling/Ceiling 491 - A07 Wall/Wall Ceiling/Ceiling 491 - A09
(4" (100mm) system shown) (4" (100mm) system shown) (6" (150mm) system shown)

H1 H1
H1

W S
W S SS
••Adaptable to many wall finishes, including W
W

drywall and tile.

Expansion Joint Systems


••491 systems designed for renovations and
surface mount installations, lowering on-site
installation costs. H1
W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
481-A07-050 2" 51 1 1/4" 32 * * 5 3/4" 146 * * 9/16" 14 1" 25
481-A07-075 3" 76 1 1/4" 32 * * 6 3/4" 171 * * 1 1/2" 38 1 1/2" 38
481-A07-100 4" 102 1 1/4" 32 * * 7 3/4" 197 * * 2" 51 2" 51
481-A07-150 6" 152 1 1/4" 32 * * 9 3/4" 248 * * 2 1/2" 64 3" 76
481-A07-200 8" 203 1 1/4" 32 * * 13" 330 * * 4" 102 4" 102
Wall to Wall 481-A07-300 12" 305 1 1/4" 32 * * 19" 483 * * 6" 152 6" 152
5/8" 5 3/4" 9/16"
Ceiling to Ceiling 491-A07-050 2" 51
5/8"
16 * * 146 * * 14 1" 25
491-A07-075 3" 76 16 * * 6 3/4" 171 * * 1
1 /2" 38 1
1 /2" 38
491-A07-100 4" 102 5/8" 16 * * 7 3/4" 197 * * 2" 51 2" 51
491-A07-150 6" 152 5/8" 16 * * 9 3/4" 248 * * 2 1/2" 64 3" 76
491-A07-200 8" 203 5/8" 16 * * 13" 330 * * 4" 102 4" 102
491-A07-300 12" 305 5/8" 16 * * 19" 483 * * 6" 152 6" 152
481-A09-050 2" 51 1 1/4" 32 * * 3 7/8" 98 * * 1/2" 13 1/2" 13
481-A09-075 3" 76 1 1/4" 32 * * 4 7/8" 124 * * 3/4" 19 3/4" 19
481-A09-100 4" 102 1 1/4" 32 * * 5 7/8" 149 * * 1" 25 1" 25
481-A09-150 6" 152 1 1/4" 32 * * 7 7/8" 200 * * 1 1/2" 38 1 1/2" 38
481-A09-200 8" 203 1 1/4" 32 * * 10 1/2" 267 * * 2" 51 2" 51
Wall to Corner 481-A09-300 12" 305 1 1/4" 32 * * 15 1/2" 394 * * 3" 76 3" 76
5/8" 3 7/8" 1/2" 1/2"
Wall to Ceiling 491-A09-050 2" 51
5/8"
16 * * 98 * * 13 13
491-A09-075 3" 76 16 * * 4 7/8" 124 * * 3/4" 19 3/4" 19
491-A09-100 4" 102 5/8" 16 * * 5 7/8" 149 * * 1" 25 1" 25
491-A09-150 6" 152 5/8" 16 * * 7 7/8" 200 * * 1 1/2" 38 1 1/2" 38
491-A09-200 8" 203 5/8" 16 * * 10 1/2" 267 * * 2" 51 2" 51
491-A09-300 12" 305 5/8" 16 * * 15 1/2" 394 * * 3" 76 3" 76
Larger sizes available

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 43


Wall and Ceiling - Surface Mount

% of MOVEMENT VAPOR BARRIER


Cost effective solutions for the many conditions ±25% to ±50% optional
encountered in interior walls. JOINT WIDTH fire rated
1" (25mm) – 4" (175mm) optional

811 Series - Variable Degree Cover


••Economical solution for retrofit/
surface mount installations.
••Snap-fit design for easy on-
site assembly.
••Clear anodized finish standard.

A07 Wall/Wall Ceiling/Ceiling


(1" (25mm) system shown)

H1

Unique ratcheted design


accommodates uneven or S
odd angle wall conditions. W

A09 Wall/Corner Wall/Ceiling


(2" (51mm) system shown)
H1

S
W

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout
811-A09-050
Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
811-A07-025 1" 25 3/8" 10 * * 3 1/8" 79 * * 1/2" 13 * *
Wall to Wall 811-A07-050 2" 51 3/8" 10 * * 4 5/8" 117 * * 1" 25 * *
Ceiling to Ceiling 811-A07-075 3" 76 3/8" 10 * * 6 1/8" 156 * * 1 1/2" 38 * *
811-A07-100 4" 102 3/8" 10 * * 7 5/8" 194 * * 2" 51 * *
811-A09-025 1" 25 3/8" 10 * * 1 3/4" 44 * * 1/4" 6 * *
Wall to Corner 811-A09-050 2" 51 3/8" 10 * * 3 1/4" 83 * * 1/2" 13 * *
Wall to Ceiling 811-A09-075 3" 76 3/8" 10 * * 4 3/4" 121 * * 3/4" 19 * *
811-A09-100 4" 102 3/8" 10 * * 6 1/4" 159 * * 1" 25 * *

44 800.222.5556 | Installation Hotline: 866.ezinpro


104 Series
A07 Wall/Wall Ceiling/Ceiling A09 Wall/Corner Wall/Ceiling
(2" (51mm) system shown) (2" (51mm) system shown)

S
W S
W

••Dual durometer seal provides secure fit and optimal flexibility.


••Designed for renovation and surface mount installations.
••Clear anodized finish standard.
••Adaptable to any wall finish.

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
104-A07-025 1" 25 * * * * 4 3/4" 121 * * 1/4" 6 1/4" 6
Wall to Wall 104-A07-038 1 1/2" 38 * * * * 5 1/8" 130 * * 3/8" 10 3/8" 10
Ceiling to Ceiling 104-A07-050 2" 51 * * * * 5 5/8" 143 * * 1/2" 13 1/2" 13
104-A07-075 3" 76 * * * * 6 5/8" 168 * * 3/4" 19 3/4" 19
104-A09-025 1" 25 * * * * 2 7/8" 73 * * 1/4" 6 1/4" 6
Wall to Corner 104-A09-038 1 1/2" 38 * * * * 3 5/16" 84 * * 3/8" 10 3/8" 10
Wall to Ceiling 104-A09-050 2" 51 * * * * 3 3/4" 95 * * 1/2" 13 1/2" 13
104-A09-075 3" 76 * * * * 4 3/4" 121 * * 3/4" 19 3/4" 19

118 Series

A07 Wall/Wall A09 Wall/Wall


(2" (51mm) system shown) (2" (51mm) system shown)

Expansion Joint Systems


W
W SS W
W SS

••Dual durometer seal provides secure


fit and optimal flexibility.
••Flush mount frame reduces sightline.
••Adaptable to any wall finish.

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
118-A07-050 2" 50 * * * * 1 7/ 8" 47 * * 1/2" 13 1/2" 13
Wall to Wall 118-A07-075 3" 75 * * * * 2 7/ 8" 73 * * 3/4" 19 3/4" 19
118-A09-050 2" 50 * * * * 1 7/ 8" 47 * * 1/2" 13 1/2" 13
Wall to Corner 118-A09-075 3" 75 * * * * 2 7/ 8" 73 * * 3/4" 19 3/4" 19

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 45


Project Profile:
Oregon Health & Science University
Collaborative Life Sciences Building
Portland, Oregon
Architect:
SERA Architects, Portland, Oregon

General Contractor:
JE Dunn Construction, Portland, Oregon

The Project
The $295 million, 500,000 sq. ft.
Collaborative Life Sciences Building will
place portions of Oregon Health & Science
University, Oregon State University and
Portland State University under one roof.
This project is anticipated to achieve LEED
Platinum certification, and will serve more
than 1,600 students annually.

JointMaster® products used


• 180 LF of floor systems
• 600 LF of interior/exterior wall systems
• 380 LF of roof systems
• R-15 insulated vapor barrier

46 800.222.5556 | Installation Hotline: 866.ezinpro


Exterior Joint Systems

Protect appearances by making expansion joints disappear with our exterior joint systems.
We've mastered this with our 601 Stealth™ Series. Seamlessly integrating into any façade and
eliminating sightline, the 601 Series is ideal for high-end exteriors.

Expansion Joint Systems

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 47


Exterior Joint Systems - Seal Systems

615 Series - Flush Mount


615 | 621 VAPOR BARRIER
% of MOVEMENT
••Industry unique seal profile holds tight, linear lines. optional EPDM (612)
±50%
••Linear Santoprene® seal design allows for fluid seismic movement Integral Backseal (616/621)
during joint expansion and contraction. JOINT WIDTH fire rated
••Field heat-weldable Santoprene seals for weather tight seams and 2" (51mm) – 24" (600mm) optional
crisp transitions.
••Seal walls are among the thickest in the industry allowing our
product to be used in soffits and corridor ceilings with no sagging.

Insulated Vapor Barrier A07 Wall/Wall Ceiling/Ceiling


(2" (51mm) system shown)
Option Available.

Throat mount
brackets reduce
W S
sightline to width
of seal only.

Pleated Santoprene® H1
seal design allows for
fluid seismic movement.

A09 Wall/Corner Wall/Ceiling


(3" (75mm) system shown)

W S

H1

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
615-A07-050 2" 51 2 3/8" 60 * * 2" 51 * * 1" 25 1" 25
Wall to Wall 615-A07-075 3" 76 2 3/8" 60 * * 3" 76 * * 1 1/2" 38 1 1/2" 38
Ceiling to Ceiling 615-A07-100 4" 102 2 3/8" 60 * * 4" 102 * * 2" 51 2" 51
615-A07-150 6" 152 2 3/8" 60 * * 6" 152 * * 3" 76 3" 76
615-A09-050 2" 51 2 3/8" 60 * * 2" 51 * * 1" 25 1" 25
Wall to Corner 615-A09-075 3" 76 2 3/8" 60 * * 3" 76 * * 1 1/2" 38 1 1/2" 38
Wall to Ceiling 615-A09-100 4" 102 2 3/8" 60 * * 4" 102 * * 2" 51 2" 51
615-A09-150 6" 152 2 3/8" 60 * * 6" 152 * * 3" 76 3" 76

48 800.222.5556 | Installation Hotline: 866.ezinpro


616 Series - Flush Mount
A07 Wall/Wall, ­Ceiling/Ceiling­
(12" (300­­mm) system shown) S

H1
H1

W
W
W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
616-A07-200 8" 200 3" 75 * * 8" 200 * * 4" 102 4" 102
616-A07-250 10" 250 3" 75 * * 10" 250 * * 5" 127 5" 127
Wall to Wall 616-A07-300 12" 300 3" 75 * * 12" 300 * * 6" 152 6" 152
616-A07-450 18" 450 3" 75 * * 18" 450 * * 9" 229 9" 229
616-A07-600 24" 600 3" 75 * * 24" 600 * * 12" 305 12" 305
616-A09-200 8" 200 3" 75 * * 8" 200 * * 4" 102 4" 102
616-A09-250 10" 250 3" 75 * * 10" 250 * * 5" 127 5" 127
Wall to Corner 616-A09-300 12" 300 3" 75 * * 12" 300 * * 6" 152 6" 152
616-A09-450 18" 450 3" 75 * * 18" 450 * * 9" 229 9" 229
616-A09-600 24" 600 3" 75 * * 24" 600 * * 12" 305 12" 305
Larger sizes available

620 Series - Surface Mount


A07 Wall/Wall A09 Wall/Corner
(2" (51mm) system shown) (3" (75mm) system shown) H2
•• Surface mount frame
design eases installation in
narrow joints and wall to W S W S
corner conditions.
•• Mill finish standard.

H1 H1
W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
620-A07-050 2" 51 2 3/8" 60 * * 5 13/16" 148 * * 1" 25 1" 25
Wall to Wall 620-A07-075 3" 76 2 3/8" 60 * * 6 13/16" 173 * * 1 1/2" 38 1 1/2" 38
Ceiling to Ceiling 620-A07-100 4" 102 2 3/8" 60 * * 7 13/16" 198 * * 2" 51 2" 51
620-A07-150 6" 152 2 3/8" 60 * * 9 13/16" 249 * * 3" 76 3" 76

Expansion Joint Systems


620-A09-050 2" 51 2 3/8" 60 4 3/8" 111 3 7/8" 98 * * 1" 25 1" 25
Wall to Corner 620-A09-075 3" 76 2 3/8" 60 4 3/8" 111 4 7/8" 124 * * 1 1/2" 38 1 1/2" 38
Wall to Ceiling 620-A09-100 4" 102 2 3/8" 60 4 3/8" 111 5 7/8" 149 * * 2" 51 2" 51
620-A09-150 6" 152 2 3/8" 60 4 3/8" 111 7 7/8" 200 * * 3" 76 3" 76

621 Series - Surface Mount


SS
A07 Wall/Wall, ­Ceiling/Ceiling­
(12" (300­­mm) system shown)
H1
H1

W
W
W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
621-A07-200 8" 200 3" 75 * * 12" 300 * * 4" 102 4" 102
621-A07-250 10" 250 3" 75 * * 14" 350 * * 5" 127 5" 127
Wall to Wall 621-A07-300 12" 300 3" 75 * * 16" 400 * * 6" 152 6" 152
621-A07-450 18" 450 3" 75 * * 22" 550 * * 9" 229 9" 229
621-A07-600 24" 600 3" 75 * * 28" 700 * * 12" 305 12" 305
621-A09-200 8" 200 3" 75 * * 10" 250 * * 4" 102 4" 102
621-A09-250 10" 250 3" 75 * * 12" 300 * * 5" 127 5" 127
Wall to Corner 621-A09-300 12" 300 3" 75 * * 14" 350 * * 6" 152 6" 152
621-A09-450 18" 450 3" 75 * * 20" 500 * * 9" 229 9" 229
621-A09-600 24" 600 3" 75 * * 26" 650 * * 12" 305 12" 305
Larger sizes available

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 49


Exterior Joint Systems - Flush Mount

% of MOVEMENT VAPOR BARRIER ••Ideal system for high-end exterior systems or conditions where
±50% optional the structural joint is located in a high profile position on the
building veneer.
JOINT WIDTH fire rated ••Flush mounted exterior system reduces sightline to two reveals of
12" (305mm) – 36"(914mm) optional approximately 1" (25mm) and 3" (76mm) dimensions.
••System is seismic-capable while allowing for daily thermal
601 Stealth™ Series movement and wind sway considerations.
••The Hinged Cover plate or ”pan” can be infilled with ••Compression spring shock absorption assembly correctly repositions
adjacent Architectural Systems to disguise the expansion the pan to the normal position after a system movement.
joint (Glazing, Metal panels and the Masonry units such as
Stone and Brick).

601 Stealth™ Series - Flush Mount

A07 Wall/Wall Ceiling/Ceiling


(2" (51mm) system shown)

W2
"A"
H1
Closed/Nominal Position

"A"

W1
Operational Position

Seismic Movement
W1 W2 H1 S1 S2 Thermal Movement +/-
+/-
Application System Joint Width Frame Height 1 Height 2 Sightline Sightline Horiz. Vert. Horiz. Vert.
US mm US mm US mm US mm US mm US mm US mm US mm
601-A07/A09-300 12" 305 17 1/2" 445 1 1/2" 38 1 3/16" 30 3 1/16" 78 1" 25 1" 25 6" 152
Wall to Wall 601-A07/A09-450 18" 457 23 1/2" 597 1 1/2" 38 1 3/16" 30 3 1/16" 78 1" 25 1" 25 9" 229
Ceiling to Ceiling 601-A07/A09-600 24" 610 29 1/2" 749 1 1/2" 38 1 3/16" 30 3 1/16" 78 1" 25 1" 25 12" 305
System available in any variation of size for 10" (250mm) -30" (750mm) expansion gaps

50 800.222.5556 | Installation Hotline: 866.ezinpro


Exterior Joint Systems - Surface Mount

651 Series - Surface Mount


A07 Wall/Wall A09 Wall/Corner
(2" (51mm) system shown) (2" (51mm) system shown)
H1 H1

••Surface mount frame accommodates uneven W S


joint widths. S W
••Rubberized washers prevent the elements from
penetrating the cover plate at anchor points.
••Factory formed transitions available. * Available with center bar (652)

••Mill finish standard – custom finishes available on


pages 66-67.

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
651-A07-050 651-A09-050
US mm US mm US mm US mm US mm US mm US mm
651-A07-025 1" 25 1 1/4" 32 * * 4 1/4" 108 * * 1/2" 13 1/2" 13
651-A07-050 2" 51 1 1/4" 32 * * 5 1/4" 133 * * 1" 25 1" 25
651-A07-075 3" 76 1 1/4" 32 * * 6 1/4" 159 * * 1 1/2" 38 1 1/2" 38
Wall to Wall 651-A07-100 4" 102 1 1/4" 32 * * 7 1/4" 184 * * 2" 51 2" 51
Ceiling to Ceiling 651-A07-150 6" 152 1 1/4" 32 * * 10 1/2" 267 * * 3" 76 3" 76
651-A07-200 8" 203 1 1/4" 32 * * 13 1/2" 343 * * 4" 102 4" 102
651-A07-300 12" 305 1 5/16" 33 * * 19 1/2" 495 * * 6" 152 6" 152
651-A09-025 1" 25 1 1/4" 32 * * 2 5/8" 67 * * 1/2" 13 1/2" 13
651-A09-050 2" 51 1 1/4" 32 * * 3 5/8" 92 * * 1" 25 1" 25
Wall to Corner 651-A09-075 3" 76 1 1/4" 32 * * 5" 127 * * 1 1/2" 38 1 1/2" 38
Wall to Ceiling 651-A09-100 4" 102 1 1/4" 32 * * 6 1/2" 165 * * 2" 51 2" 51
651-A09-150 6" 152 1 1/4" 32 * * 9 1/2" 241 * * 3" 76 3" 76
651-A09-200 8" 203 1 1/4" 32 * * 12 1/2" 318 * * 4" 102 4" 102
Larger sizes available

Expansion Joint Systems

University of Utah L.S. Skaggs, Salt Lake City, UT


601 Stealth™ Series

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 51


Exterior Joint Systems - Aluminum Roof Covers

% of MOVEMENT VAPOR BARRIER


Exterior roof systems available in standard hard- ±50% Included (661), Optional (672)
lid aluminum covers as well as flexible, closed
cell EPDM bellows configurations. JOINT WIDTH fire rated
1" (25mm) – 12"(300mm) optional

661 Series - Curb Mounted Centering Bar


A01 Roof/Wall A02 Roof/Wall
(2" (51mm) system shown) (8" (203mm) system shown)
S
H1 S

W
661 – 45° Curb Mounted
••Frame angled to assist in securing roofing A02 Roof/Wall H1
membrane down on 45° curb. (2" (51mm) system shown) S
••Moisture barrier included.
••Weather washers prevent leaking where H1
fasteners penetrate frames/covers.
••Factory preformed transitions available. W
••Mill finish standard.
W
••Custom options on pages 66-67.

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
661-A01-025 1" 25 1 1/4" 32 * * 4 1/4" 108 8 3/8" 213 1/2" 13 1/2" 13
661-A01-050 2" 51 1 1/4" 32 * * 5 1/4" 133 8 7/8" 225 1" 25 1" 25
661-A01-075 3" 76 1 1/4" 32 * * 6 1/4" 159 9 5/8" 244 1 1/2" 38 1 1/2" 38
Roof to Roof 661-A01-100 4" 102 1 1/4" 32 * * 7 1/4" 184 10 5/8" 270 2" 51 2" 51
661-A01-150 6" 152 1 1/4" 32 * * 10 1/2" 267 12 1/8" 308 3" 76 3" 76
661-A01-200 8" 203 1 1/4" 32 * * 13 1/2" 343 14 1/8" 359 4" 102 4" 102
661-A01-300 12" 305 1 3/8" 35 * * 19 1/2" 495 18 1/8" 460 6" 152 6" 152
661-A02-025 1" 25 1 1/4" 32 * * 2 5/8" 67 4 5/8" 117 1/2" 13 1/2" 13
661-A02-050 2" 51 1 1/4" 32 * * 3 5/8" 92 5 3/8" 137 1" 25 1" 25
661-A02-075 3" 76 1 1/4" 32 * * 5" 127 6 3/8" 162 1 1/2" 38 1 1/2" 38
Roof to Wall 661-A02-100 4" 102 1 1/4" 32 * * 6 1/2" 165 7 3/8" 187 2" 51 2" 51
661-A02-150 6" 152 1 1/4" 32 * * 9 1/2" 241 9 3/8" 238 3" 76 3" 76
661-A02-200 8" 203 1 1/4" 35 * * 12 1/2" 318 11 3/8" 289 4" 102 4" 102

Larger sizes available

52 800.222.5556 | Installation Hotline: 866.ezinpro


691 Series - Vertical Curb Mount
••Easy on-site assembly A01 Roof/Roof
and installation. (2" (51mm) system shown) A02 Roof/Wall
(2" (51mm) system shown)
••Multi-directional seismic movement.
S S
••Moisture barrier included.
••Neoprene weather washers prevent H1
leaking where fasteners penetrate H1
frames/covers.
••2x wood blocking mount.
••Factory formed transitions available.
••Cover plate available in stainless steel
or alternate secondary finishes. W W

W H1 S B Movement +/-
Application System Joint Width Frame Height 1 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm
691-A01-025 1" 25 1 1/4" 32 4 1/4" 108 8 3/8" 213 1/2" 13 1/2" 13
691-A01-050 2" 51 1 1/4" 32 5 1/4" 133 8 7/8" 225 1" 25 1" 25
691-A01-075 3" 76 1 1/4" 32 6 1/4" 159 9 5/8" 244 1 1/2" 38 1 1/2" 38
Roof to Roof 691-A01-100 4" 102 1 1/4" 32 7 1/4" 184 10 5/8" 270 2" 51 2" 51
691-A01-150 6" 152 1 1/4" 32 10 1/2" 267 12 1/8" 308 3" 76 3" 76
691-A01-200 8" 203 1 1/4" 32 13 1/2" 343 14 1/8" 359 4" 102 4" 102
691-A01-300 12" 305 1 3/8" 35 19 1/2" 495 18 1/8" 460 6" 152 6" 152
691-A02-025 1" 25 1 1/4" 32 2 5/8" 67 4 5/8" 117 1/2" 13 1/2" 13
691-A02-050 2" 51 1 1/4" 32 3 5/8" 92 5 3/8" 137 1" 25 1" 25
691-A02-075 3" 76 1 1/4" 32 5" 127 6 3/8" 162 1 1/2" 38 1 1/2" 38
Roof to Wall 691-A02-100 4" 102 1 1/4" 32 6 1/2" 165 7 3/8" 187 2" 51 2" 51
691-A02-150 6" 152 1 1/4" 32 9 1/2" 241 9 3/8" 238 3" 76 3" 76
691-A02-200 8" 203 1 1/4" 35 12 1/2" 318 11 3/8" 289 4" 102 4" 102
Larger sizes available

Available Transitions
••Metal and EPDM-Bellow Joint transitions available – Consult with your Sales Representative to determine which of our many
configurations apply to your unique building conditions.

Expansion Joint Systems

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 53


Exterior Joint Systems - Bellows Systems

672 | 674 Bellows


••Remains watertight during severe seismic movement.
••Splicing kits available for simple installation.
••Flanges available standard as galvanized optional stainless steel, copper, aluminum and EPDM as well.
••Expansion joints intersect and change directions. Ensure maximum flexibility, clean lines and waterproofing in these critical areas
with the application of factory-formed intersections and transitions.

672 Series - Bellows/Canted Roof


G01 Canted Roof/Roof G02 Canted Roof/Wall
(2" (51mm) system shown) (2" (51mm) system shown)

4”
[102mm]

W
W
W

W H1 H2 S B 672-A02-050
Movement +/-
Application System Joint Width
672-A01-050
Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
672-G01-050 2" 51 * * * * * * * * 1" 25 1" 25
672-G01-075 3" 76 * * * * * * * * 1 1/2" 38 1 1/2" 38
Roof to Roof 672-G01-100 4" 102 * * * * * * * * 2" 51 2" 51
672-G01-150 6" 152 * * * * * * * * 3" 76 3" 76
672-G01-200 8" 203 * * * * * * * * 4" 102 4" 102
672-G02-050 2" 51 * * * * * * * * 1" 25 1" 25
672-G02-075 3" 76 * * * * * * * * 1 1/2" 38 1 1/2" 38
Roof to Wall 672-G02-100 4" 102 * * * * * * * * 2" 51 2" 51
672-G02-150 6" 152 * * * * * * * * 3" 76 3" 76
672-G02-200 8" 203 * * * * * * * * 4" 102 4" 102

674 Series - Bellows/Curb Flange

G01 Curb Flange Roof/Roof G02 Curb Flange Roof/Wall


(2" (51mm) system shown) (2" (51mm) system shown)

2"
2"
2"
2"
W W

W H1 H2 S B Movement +/-
Application System Joint Width Frame Height 1 Height 2 Sightline Blockout Horizontal Vertical
US mm US mm US mm US mm US mm US mm US mm
674-G01-050 2" 51 * * * * * * * * 1" 25 1" 25
674-G01-075 3" 76 * * * * * * * * 1 1/2" 38 1 1/2" 38
Roof to Roof 674-G01-100 4" 102 * * * * * * * * 2" 51 2" 51
674-G01-150 6" 152 * * * * * * * * 3" 76 3" 76
674-G01-200 8" 203 * * * * * * * * 4" 102 4" 102
674-G02-050 2" 51 * * * * * * * * 1" 25 1" 25
674-G02-075 3" 76 * * * * * * * * 1 1/2" 38 1 1/2" 38
Roof to Wall 674-G02-100 4" 102 * * * * * * * * 2" 51 2" 51
674-G02-150 6" 152 * * * * * * * * 3" 76 3" 76
674-G02-200 8" 203 * * * * * * * * 4" 102 4" 102

54 800.222.5556 | Installation Hotline: 866.ezinpro


Seals

Our Compression Seals create crisp, linear sightlines with a patented design to eliminate
waviness. They’re also engineered to make installation easier and heat weldable. Both
Compression Seal and Foam Seal products are 100% weather tight, UV resistant and built to
last through extreme temperatures and chemicals.

Expansion Joint Systems

College of San Mateo


616 Joint System

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 55


W

1200
W SERIES

Foam Seals 2 3/16"


(60mm)

1250 Series 1250 Series


(2" (50mm) system shown) (2" (50mm) double-sided system shown)

W 1250
SERIES

2 3/16"
1250 Series

1200 Series – Seal


1200 Series 1200 Series (60mm)

(2" (50mm) system shown) (2" (50mm) double-sided system shown) (2" (50mm) Custom triple-sided system shown)

W W W W

1200
W
W SERIES

(2" (50mm) double-sided (2" (50mm) custom H1


2 3/16"
(60mm)
system shown) triple-sided system shown) (2" (50mm) system shown)
1250 Series 1250 Series

• Foam seals create a watertight, insulated seal.


(2" (50mm) system shown) (2" (50mm) double-sided system shown)
• 1200 foam seal comes pre-compressed and includes peel and
• Capable of handling vertical and horizontal joint movement.
W
stick adhesive sides, making installation easy.
• Available in 26 standard colors (custom colors available • Available in single, double or triple faced versions.
upon request). See pages 66-67 for color options. • Excellent sound attenuation qualities reaching an STC rating of 52.
W 1250
SERIES

W H1 Movement +/-
Application System Joint Width Seal Depth Horizontal Vertical
2 3/16"
1250 Series
(60mm)
US
(2" (50mm) Custom triple-sided system shown) mm US mm US mm US mm
1200-050 1/2" 13 1 1/2" 38 1/4" 6 1/4" 6
1200-100 1" 25 1 1/2" 38 1/2" 13 1/2" 13
W
1200-150 1 1/2" 38 2" 51 3/4" 20 3/4" 20
Floor to Floor 1200-200 2" 51 2" 51 1" 25 1" 25
Floor to Wall 1200-250 2 1/2" 64 2" 51 1 1/4" 32 1 1/4" 32
1 1
Wall to Wall 1200-300 3" 76 3" 76 1 /2" 38 1 /2" 38
1200-350 3 1/2" 89 3" 76 1 3/4" 44 1 3/4" 44
Wall to Corner 1200-400 4" 102 4" 102 2" 51 2" 51
1200-500 5" 127 4" 102 2 1/2" 64 2 1/2" 64
1200-600 6" 152 4" 102 3" 76 3" 76
Other sizes available

1250 Series – Seal 1250 Series


(2" (50mm) system shown)

• Foam seals create a watertight, insulated seal.


• Capable of handling vertical and horizontal joint movement.
• Available in 26 standard colors (custom colors available upon request). W
See pages 66-67 for color options.
• 1250 system is compressed in field and installed utilizing silicone or
epoxy adhesive (supplied by others).
• Good sound attenuation qualities. H1
(2" (51mm) system shown)

W H1 Movement +/-
Application System Joint Width Seal Depth Horizontal Vertical
US mm US mm US mm US mm
1250-050 1/2" 13 1 1/2" 38 1/8" 3 1/8" 3
1250-100 1" 25 1 1/2" 38 1/4" 6 1/4" 6
1250-150 1 1/2" 38 2" 51 3/8" 9 3/8" 9
Floor to Floor 1250-200 2" 51 2" 51 1/2" 13 1/2" 13
Floor to Wall 1250-250 2 1/2" 64 2" 51 5/8" 16 5/8" 16
3/4" 3/4"
Wall to Wall 1250-300 3" 76 3" 76 20 20
1250-350 3 1/2" 89 3" 76 7/8" 22 7/8" 22
Wall to Corner 1250-400 4" 102 4" 102 1" 25 1" 25
1250-500 5" 127 4" 102 1 1/4" 32 1 1/4" 32
1250-600 6" 152 4" 102 1 1/2" 38 1 1/2" 38
Other sizes available

56 800.222.5556 | Installation Hotline: 866.ezinpro


1100 Series – Seal
• High heat, weather and UV resistant.
• 100% watertight foam seal. H1
• Excellent for roof applications and under metal cover
plate systems.
• Allows for 50% Tension | 60% Compression | W
100% Shear movement.
• Available in Gray only. (2" (51mm) system shown)
• Field applied paint coating available (JPR007).
Movement + / -
Nominal Joint Width (W) Seal Depth (H)
Application System Compression Expansion
US mm US mm US mm US mm
1100-100 1" 25 2" 51 .4" 10 1.8" 46
1100-150 1 1/2" 38 2" 51 .8" 20 2.6" 66
1100-200 2" 51 2" 51 1.1" 27 3.6" 91
1100-250 2 1/2" 64 2" 51 1.3" 33 4.2" 107
Floor to Floor 1100-300 3" 76 3" 76 1.6" 40 5.2" 132
1100-350 3 1/2" 89 3" 76 1.8" 46 5.8" 147
1100-400 4" 102 4" 101 2" 51 6.5" 165
1100-450 4 1/2" 114 4" 101 2.2" 56 7.3" 185
1100-500 5" 127 4" 101 2.5" 64 8.1" 206
Other sizes available

1150 Series – Seal


• Chemical, weather and UV resistant.
• 100% watertight foam seal.
• Excellent when in contact with grade or oils.
H1
• Allows for 25% Tension | 50% Compression | 100% Shear
movement. W
• Ridged sides trap and pool epoxy (JPR003) providing superior
adhesion to the joint surface to resist imposed loads. (2" (51mm) system shown)
• Available in Gray only.
• Field applied paint coating available (JPR007).

Movement + / -
Nominal Joint Width (W) Seal Depth (H)
Application System Compression Expansion
US mm US mm US mm US mm
1150-100 1" 25 2" 51 .5" 13 1.25" 32
1150-200 2" 51 2" 51 1" 25 2.5" 64

Expansion Joint Systems


1150-300 3" 76 3" 76 1.5" 38 3.75" 95
1150-400 4" 102 4" 101 2" 51 5" 127
Floor to Floor 1150-500 5" 127 4" 101 2.5" 64 6.25" 159
1150-600 6" 152 5" 127 3" 76 7.5" 191
1150-700 7" 178 5" 127 3.5" 83 8.75" 222
1150-800 8" 203 5" 127 4" 89 10" 254

1175 Series – Seal

• Developed to meet DOT performance requirements. H1


• Allows for 100% shear movement.
• Seal is UV stable and resistant to solvents and fuels.
• Arrives to site pre-compressed and is installed with epoxy. W
• Available in Gray only. (2" (51mm) system shown)

Movement ±
Joint Width (W) Seal Depth (H)
Application System Compression/Expansion
US mm US mm US mm
1175-100 1" 25 1 1/2" 38 1/2" 13
1175-200 2" 51 2" 51 1175 1" 25
Floor to Floor SERIES
1175-300 3" 76 3" 76 1 1/2" 38
1175-400 4" 102 4" 102 2" 51
Larger sizes available

(OPTIONAL)FIRE BARRIER:
SELF-LEVELING SEALANT AND
inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions MINERAL WOOL SHOWN
57
Compression Seals - Parking and Open Structure

AR Series – Seal
• Heavy pedestrian/Moderate vehicle loading capabilities.
W
W
• Incorporation of ribs on side faces to aid in pooling epoxy
1/8"
and adding surface area for increased adhesion to deck.
• Installed with 2-part epoxy. H1
H1

• Field heat-welded seams provide 100% watertight conditions.


• Patent Pending (2" (51mm) system shown)

H1
Seismic Seismic
Nominal Joint Width
Application System Minimum Joint Width Maximum Joint Width
Seal Depth
US mm US mm US mm US mm
AR-100S 1” 25 3/4” 21 1-1/2” 39 2” 52
Architectural AR-200S 2" 50 1" 25 3" 75 2 3/16" 56
Compression AR-300S 3" 75 1 1/2" 38 4 1/2" 114 3 5/16" 84
Seals
AR-400S 4" 100 2" 51 6" 152 3 5/16" 84
*Industry best practices dictate seals should always be kept in compression.

CR Series – Seal
• Heavy Duty and high rate vehicular applications. W
W
1/8"
• Installed with a primer and Elastomeric concrete header at
the nosings for secure placement and impact resistance. H1
• Field heat welded seams provide 100% watertight conditions.
• Patent Pending (2" (51mm) system shown)

B H1
Nominal Joint Width Minimum Joint Width Maximum Joint Width
Application System Blockout Seal Depth
US mm US mm US mm US mm
CR-200S 2" 50 1 1/2" 38 2 1/2" 57 3" 75 2 3/16" 56
Architectural
Compression CR-300S 3" 75 2 1/4" 57 3 1/2" 89 3" 75 3 5/16" 84
Seals CR-400S 4" 100 3" 76 5" 127 3" 75 3 5/16" 84

DR Series – Seal
• Heavy Duty pedestrian/vehicular loading capabilities.
W
W
1/8"
• Appropriate for horizontal applications.
• Provides for fast installation utilizing a no-mix “Lubricant H1
Adhesive” (JPR009).
• Installation conditions are not weather sensitive.
.75" (19mm} system shown

H1
Nominal Joint Width Minimum Joint Width Maximum Joint Width
Application System Seal Depth
US mm US mm US mm US mm
DR-075 3/16" 19 7/16" 11 1 1/16" 27 1 1/16" 27
Architectural DR-100 1" 25 5/8" 16 1 3/8" 35 1 1/8" 29
Compression DR-125 1 1/4" 32 3/4" 19 1 3/4" 45 1 1/2" 38
Seals DR-150 1 1/2" 38 7/8" 22 2 1/8 54 2 1/2" 64
DR-175 1 3/4" 45 1 3/16" 30 2 9/16 65 2 1/2" 64

58 800.222.5556 | Installation Hotline: 866.ezinpro


Accessories

We cover all your building needs in one place with accessories to protect your structures
from damage. Whether it's Fire Barriers, Vapor Barriers or Parking Protection products, you
finally have a one-stop shop that can outfit you with a comprehensive line of industry-
leading solutions.

Expansion Joint Systems

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 59


Fire Barriers - 900 Series

We have Fire Barrier configurations available to meet any project’s needs. Building expansion joint and slab
openings inherently create a pathway for fire and smoke to travel and spread throughout the structure.
JointMaster’s broad array of Fire Barrier products provide protection for 2, 3 and 4-hour rated conditions to
keep the threat contained.

Fire Blankets

975 - Fire Blanket


••1, 2, 3 and 4 hour rated systems available. •• Mounting configurations available for both wall and floor
••Tested in accordance with: UL 2079/ ULC S-115 “FTH” (FTH: Rating conditions: -Top (flush) Mount -Low Profile (recessed) Mount
Fire, Temperature and Hose) -ASTM-E119/E1399/E1966. -Bottom Mount
••±50% movement. ••Factory fabricated horizontal and vertical transitions ensure
the fire rating requirements of UL 2079 are not compromised -
••Accommodates joint widths from 2” (51mm) to 27” (686mm) wide. Details & directions for field fabricated transitions also available.
••No fire caulk required at splices. •• Water Guard systems are available to protect the blanket
••Single sided installation. system and fire rating during and after construction of open
••Pre-attached flanges drastically reduce labor cost. structures such as parking facilities and stadiums. (Optional
drain tubes available.)
•• Product comes with factory made male to female splices,
eliminating the need for complex field manipulation at seams.

4" (102mm) 757-A01 Floor


4"(102mm) System
757-A01 Shown
floor system shown
(2" (51mm) floor system shown)
(Available only for 975) (Applied to 301-A01 system)
GALVANIZED STEEL
RETAINING FLANGE

HEX HEAD
CONCRETE SCREW

GALVANIZED STEEL FLANGE

HEAT SHIELD
20 GA. GALVANIZED RETAINER
MAIN BARRIER

Bottom Mount Surface Mount


950 - Fire Blanket
• Our most cost-effective large gap barrier. 4" (102mm) 221-A01 floor system shown
• 2 hour rated meeting UL2079, ASTM E-1399, ASTM 4"(102mm) 221-A01 floor system shown

E-1966.
• Meets “Hose Stream Test” for vertical wall applications.
• ±50% seismic movement.
• Installs with retaining flanges.
• Accommodates joint widths from 2" (50mm) to 24" GALVANIZED STEEL
FLANGE

(600mm). Low Profile


• Chase wall covers available.

60 800.222.5556 | Installation Hotline: 866.ezinpro


Fire Barriers

921 | 925 Mineral Wool and Sealant

(1" (25mm) floor system shown)


••Cost effective system for joint widths up (Applied to 106-A01 system)
to 3" (127mm).
••Mineral wool supplied in 4' (1.2m)
lengths and compressed into gap for 921 SILICONE
SEALANT

easy installation.
••Up to 3 hour rated meeting UL2079. 925 MINERAL WOOL

••System accommodates horizontal


movement to 25%.
••Meets “Hose Stream Test" for
masonry walls.
REACTOFIRE MINERAL WOOL AND
SILICONE SEALANT FIRE BARRIER SYSTEM
(OPTIONAL)

935 – Firestop System | 925 | 935 Mineral Wool and Sealant

(1" (25mm) floor system shown) (Applied to 106-A01 system)

ULTRA BLOCK SEALANT


INSULATED-WOOL 1/2” [13MM] DEEP

• Cost effective system for joint widths up to 3" (127mm). • System accommodates horizontal movement to 20%.
• Mineral wool supplied in 4’ (1.2m) lengths and • Meets “Hose Stream Test” for masonry walls.
compressed into gap for easy installation. • Concrete installations only.
• Up to 3 hour rated meeting UL2079.

Expansion Joint Systems


Fire Rated Foam

990/995 – Fire Rated Foam

••Provides a 2 or 3 hour fire rating in accordance with UL-2079 with either


25% or 50% movement capabilities.
••990 system does not rely on the silicone face for its rating. The foam
is impregnated with fire retardant material, meaning the rating is not
compromised due to vandalism or damage to the silicone face.
••Fire foam seals are watertight and also have sound attenuation qualities.
••Seal material is UV stable and resistant to solvents.
••Capable of handling vertical and horizontal joint movement.
••990 foam seal comes pre-compressed for installation ease.
••System is available in 26 standard colors (custom colors available).
See pages 66-67 for color options.

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 61


Vapor Barriers - Moisture Deterrent Membranes

Vapor Barriers are designed to resist the penetration of moisture through wall, ceiling and floor assemblies
of a structure. JointMaster’s systems are designed to meet the challenges of keeping the elements where
they belong- outside. Our membranes deter air currents, wind-driven rain and ensure for the weep of
condensation to the exterior.

Standard Vapor Barrier


••High performance, fiber-reinforced EPDM membrane.
••Provided in conjunction with any exterior joints, also available as an additional feature
to our complete line of products.
••Allows for joint movement matching the requirements of the Architectural Joint cover.
••Durable .045" (45mil) thick sheet good resists tearing, puncture and wear-through.

Insulated Vapor Barrier


With EJ cover frames

••Exterior grade system capable of


matching 50% joint movement.
H
••Consists of fiber-reinforced
EPDM membranes, sandwiching Appox. 1 1/2" [38mm]

commercial grade insulation, W


W Under Frame
With termination bar
adhered and pinned together to Termination Bar 1" [25mm] Wide
form a seismic-capable assembly. w/ 3/16" [4.8mm] Holes

••Maintains a minimum R-Value of 15. Fastener @12" [305mm] O.C. (By Others)

••Seams and directional transitions


designed to ensure a watertight seal H
and positive condensation drainage.

W
W

W H Movement ±
Application System Joint Width Insulated Vapor Barrier Depth
Compression/Expansion
US mm US mm US mm
JL006-IVB 6" 152 5" 127 3" 76
Wall to Wall JL008-IVB 8" 203 6" 152 4" 102
JL010-IVB 10" 254 7" 178 5" 127
Wall to Corner
JL012-IVB 12" 305 8" 203 6" 152
Roof to Roof JL018-IVB 18" 457 10" 457 9" 229
Roof to Wall JL024-IVB 24" 610 12" 305 12" 305
JL028-IVB 28" 711 14" 356 14" 356

62 800.222.5556 | Installation Hotline: 866.ezinpro


Facility Protection

JOS-SPD 1200/1800 – Speed Guard


• Reduces vehicle speeds to 2-5mph (3km/h-8km/h).
• Made of environmentally responsible shredded
tires, diverting 3.2 (SPD 1200) to 5.1 (SPD 1800)
tires from the landfill with every piece ordered.
• Reflective in-molded pavement marking strip
alerts driver of the tire stops presence in low light
situations.
• Luminous “Cat Eye” reflectors light up as
vehicles approach.
• Ideal for areas with heavy pedestrian flow such as End Cap
entrances or crosswalks. (Optional)

• Greatly reduces risks of pedestrian-car collisions.


• Highly resilient material resists U.V., moisture,

Expansion Joint Systems


oil and extreme temperatures and will never chip, 2.25
crack or fade. Plus it's capable of conforming to 12.00
[57mm]
9.00 72.00 / 48.00
uneven surfaces. [304mm] [228mm] [1.8m] [1.2m]

JOS-TRSTP 500/1800 – Tire Stop


• Tire stop is available in two (2) different lengths –
T1800: 6' (1.8M) and T500: 22" (.5m).
• Prevents drivers from over parking and encroaching into
walkways or other parking spots.
• Highly resilient material resists U.V., moisture, oil,
extreme temperatures and will never chip, crack, or fade;
plus its capable of conforming to uneven surfaces.
• Made of environmentally responsible shredded tires,
diverting 1 (TRSTP 500) to 3.4 (TRSTP 1800) tires from
the landfill with every piece ordered.
• Reflective in-molded pavement marking strip alerts Lag Bolt Mounting Hole
driver of the tire stops presence in low light situations.
• Available in three (3) colors to designate space type or 4”
for facility branding: Black, Blue and Terracotta. [100mm] In-Molded Reflective Strip

• Optional in-molded pavement strip colors: 6”


[154mm]
6’ [1.8m]
White or Yellow.

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 63


JPark-C-075 System Shown

.50
[13mm]
CONCRETE SCREW
ANCHOR
(3 PER WING)

EPDM
HIGH IMPACT
3.00 CORNER GUARD
[78mm]

JOS-CRNR 075 – Standard Corner Guards JPark-C-075S System Shown


JPark-C-075 System Shown (Optional High-Vis Strip Shown)

.50
[13mm]
CONCRETE SCREW
ANCHOR
(3 PER WING)

HIGH VISIBILTY
EPDM STRIP (OPTIONAL)
HIGH IMPACT
3.00 CORNER GUARD 1.00
[78mm] [25mm]

(JOS-CRNR 075 system shown)


(JOS-CRNR 075 system shown) (optional High-Visibility strip shown)
JPark-C-075S System Shown
(Optional High-Vis Strip Shown)

• Corner guard height: 39.3" (1m). • Capable of withstanding moderate impact from vehicles.
• Economic solution to protect column and wall corners • Optional: high visibility strip helps corner guard standout in
from impact. low light areas.
• Aids in preventing damage to customers' vehicles.
HIGH VISIBILTY
STRIP (OPTIONAL)

JOS-CRNR 090 – High Impact Corner Guards 1.00


[25mm]

.709"
[18mm]

3.54"
[90mm]

GALVANIZED
STEEL RETAINER HIGH IMPACT
EPDM CORNER
GUARD

• Corner guard height: 39.3" (1m). • Heavy Duty EPDM corner guard snaps onto aluminum
• The gold standard for corner protection. retainer clips.
• Easy to install and easy to replace if damaged. • Galvanized steel retainer clip protects the corner’s
structural integrity.
• Large collision chambers cushion door impacts better than
any other corner guard. Also, it is more forgiving on side
panels and plastic bumpers.

64 800.222.5556 | Installation Hotline: 866.ezinpro


JOS-WALL 200 – Wall Guard

1.25 1.25
[32mm] [32mm]

8.00 8.00
[203mm] [203mm]

• Wall guard length: 120" (3m). CONCRETE CONCRETE


SCREW ANCHOR SCREW ANCHOR
• The gold standard for heavy impact facility wall protection. (AS NEEDED) (AS NEEDED)
HIGH VISIBILITY HIGH VISIBILITY
• Capable of conforming to straight and curved wall conditions. STRIP (OPTIONAL) STRIP (OPTIONAL)

Expansion Joint Systems


• Can wrap circular columns the diameter of 18" (450mm)
and greater.
• Optional: High visibility strip helps wall guard stand out in (JOS-WALL 200 system shown) (JOS-WALL 200 system shown)
low light areas. (optional High-Visibility strip shown)

JOS-DOCK 075 – Dock Bumper

3.01
[76mm]

2.80
[71mm]

CONCRETE SCREW
ANCHOR

• Standard length of 24" (610mm).


• Dock Bumper is made of thick 3/4" (19mm) EPDM capable of withstanding the repeated forces encountered within loading docks.
• Mounted using Heavy Duty fasteners. Anchorage locations field drilled to meet project specific requirements.

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 65


Available Finishes

Stocked Finishes

Clear
Mill
Anodized

Custom Kynar® Color Coatings

Bone Light
Ivory Sandstone Burnt Sun Sierra Tan Beige
White Seawolf Beige

Charcoal Patine Hartford


Dove Gray Slate Gray Dark Ivy Interstate Blue
Gray Green Green

Military Colonial Sage


Boysenberry Quaker Bronze Black
Blue Red Brown

Custom Color Anodized Finishes

Medium Extra-Dark
Champagne Light Bronze Dark Bronze Black
Bronze Bronze

Due to the printing process, colors may vary. For more accurate color selection, please request samples.

66 800.222.5556 | Installation Hotline: 866.ezinpro


Seal Colors

Standard Santoprene® Seals

Bright White Off-White Beige Gray Black

Primary Silicone Seal Colors - Dow Corning® 790

Bright White Precast White Limestone Natural Stone Sandstone Adobe Tan Dusty Rose

Expansion Joint Systems


Rustic Brick Blue Spruce Bronze Charcoal Black Grey

Secondary Silicone Seal Colors - Pecora® 890 NST

Anodized Aluminum
Tru White Precast Beige Limestone Natural Stone
Aluminum Stone

Classic Hartford
Sandstone Charcoal Gray Black Red Rock
Bronze Green

"Primary" indicates standard cost and leadtime.


"Secondary" indicates standard cost and extended leadtime.
Due to the printing process, colors may vary. For more accurate color selection, please request samples.

inprocorp.com/jointmaster | Download BIM objects, specifications and installation instructions 67


inprocorp.com • 800.222.5556 • 262.679.9010 • World Headquarters S80 W18766 Apollo Drive, Muskego, WI 53150 USA

ISO 14001:2013 ISO 9001:2014


Printed with soy ink on recycled fiber including 10% post-consumer fiber. CERTIFIED CERTIFIED ©2015 Inpro Corporation / XX00

You might also like