Alignment Sheet For ONGC

The document lists intersection points along a path, including the latitude and longitude of each point, the deflection angle between points, and the distance in meters between points. There are a total of 7 intersection points listed with their associated details.

Uploaded by

Saravanan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
801 views1 page

Alignment Sheet For ONGC

The document lists intersection points along a path, including the latitude and longitude of each point, the deflection angle between points, and the distance in meters between points. There are a total of 7 intersection points listed with their associated details.

Uploaded by

Saravanan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
  • Engineering Drawing Overview

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

INTERSECTION POINTS (IP/TP)


TPO TP1 TP2 TP2/1 TP3 TP4 TP4/1 TP4/2 TP4/3 TP4/4 TP4/5 TP4/6 TP5 TP6 TP7

85'52'5" L 53'11'56" R 14'07'12" 03'41'02" 0'19'55" 0'19'53" 39'29'28"


DEFLECTION ANGLE
P P

18.84

11.43
DISTANCE BETWEEN IPs (m) 30.28 109.97 57.63 285.90 164.48 142.11 38.71 213.87 75.55 257.13 102.89 128.18 113.03

STATE AND DISTRICT TAMILNADU , NAGAPATTINAM DISTRICT

N
O O

liya
m
1K
Koo

2.1
To
PLANIMETRY
Mainly Paddy Field

ayar
To Pazh
7.63 Km
N N
SCALE
ALONG THE ALIGNMENT 1 : 2500
ACROSS THE ALIGNMENT 1 : 2500

p
Bus Sto
STARDING PONT TPI - P15
TEMPLE CS - 007
TP TABLE CONNECTIVITY OF ONGC TPI - P13
Ch:1636.97
TPI - P6 TPI - P11 Ch:1497.36
TP0 - P1 CH: 0.00
TP NO EASTING NORTHING Ch:502.62m
TPI - P8 Ch:1137.34m BH7
M TPI - P7 BH6 M
TP 0 369683.269 1249779.545 TPI - P3 TPI - P4
Ch:667.10m
Ch:809.21m BH5
TPI - P14
Ch:49.12m Ch:159.09m e TPI - P12
BH4 elin CS - 006 Ch:1508.79m
TP 1 369669.901 1249760.230 BH1
CS - 001 TPI - P10 CS - 005 GC
Pip Ch:1394.47m 11kv Power Line
TPI - P9 ch ON
Ch:1061.79m 4 In Height 6.341m
TP 2 369695.165 1249739.904 BH2
CS - 004 Ch:847.92m

ver
Cart Track CS - 003

Nala

Nala
TP 3 369689.321 1249574.288

yar Ri

Road
11kv Power Line

ad

Manniyar Channel
Height 6.413m
TP 4 369749.347 1249294.290

ayar Ro

manni

Asphalt
TPI - P2

Fie
CS - 002 TPI - P5

ld
TP 5 369894.902 1248310.432 Ch:18.84m Ch:216.72m

ch
Pudu
- Pazh

an
ne
TP 6 369896.512 1248299.111

l
u
L ONGC MADANAM ONGC MADANAM FIELD L

To Alangad
Puthur
TP 7 369915.334 1248172.306

ack
Mainly Paddy Field

2.35 Km

MDNM/CPF/PL/6072/ALI (SH.02 OF 17)


Cart Tr

MATCH LINE FOR CONT. REFER


TO S.V STATION MEMATHUR
CAUVERY BASIN
FROM CONNECTIVITY OF
ONGC MADANAM FIELD
To Puthur
11.20 Km

11KV POWER LINE HEIGHT 6.341M CH. 1+454.31

11KV POWER LINE HEIGHT 6.413M CH. 1+469.63


K K
ASPHALTED ROAD CH. 0+166.01

UNC MANNIYAR CHANNEL CH. 0+828.57

4 INCH ONGC PIPELINE CH. 1+315.37

ASPHALTED ROAD CH. 1+505.52


PUTHUMANNIYAR RIVER CH. 0+180.96

CART TRACK CH. 0+192.26

CART TRACK CH. 0+305.53


START POINT CH 0+000.00

FIELD CHNNEL CH. 1+505.52


GROUND PROFILE

NALA CH. 0+530.17

NALA CH. 1+131.49


J SCALE: J

HORIZONTAL 1 : 2500
VERTICAL 1 : 250

I DATUM w.r.t MSL : -6m I

GROUND LEVELS
-0.531
-0.045

0.654

0.599

0.570

0.577

0.592

0.563

0.516

0.510

0.548
0.518

0.043
0.069
1.172
0.823
1.501

1.494

1.383

1.334

0.918

0.350

0.463

0.871

0.782

0.840
0.945
1.128

1.641
1.557
0.504
0.639
0.639
1.002
0.756

0.606

0.628

0.658

0.674

1.622
2.608
2.672
2.090

2.387
1.678
1.673
1.624

0.545

0.509

0.553

0.600

0.491

0.501
0.582

0.576

0.530
1.043
1.016
0.693

0.655

0.658

0.709

0.731
0.732

0.723
0.713

0.659

0.621

0.601

0.581

0.583

0.594
1.800
1.844
1.701

1.782

1.548

1.417
1.811
1.008
1.023

1.076

1.216

1.396

1.396
(IN METERS)
18.839

30.280

28.990

29.030

21.550

30.400

15.240
10.850

42.690

29.230

16.890

15.660

28.520

29.730

31.250

30.630

23.550

19.220

11.190

14.730
10.300

14.380

39.150

32.180

28.040

20.660

31.630

25.600

29.680

24.360

30.840

14.380

61.020

27.720

31.580

28.020

28.950

24.640

11.940

28.270

36.130

56.990

23.800

28.040

32.630

35.290

53.680

19.220

32.360

27.480

15.320

27.730

10.640

49.080

29.540

28.410

10.510

12.390
15.080

28.420

28.930

18.490
DISTANCE BETWEEN LEVEL
4.210
5.420
1.530
9.670
6.250
3.420

7.340

5.040

4.980

8.240
4.200
6.910

2.720
5.100
3.330

7.480

1.580

9.720
POINTS (IN METERS)

SURFACE / TERRAIN DETAILS

0.000
H H
0+000.00

0+018.84

0+049.12

0+078.11

0+107.14

0+128.69

0+159.09
0+166.01
0+171.29
0+180.96
0+187.21
0+192.26

0+205.87
0+216.72

0+259.41

0+288.64

0+305.53

0+321.19

0+349.71

0+379.44

0+410.69

0+441.32

0+464.87

0+484.09
0+495.28
0+502.62

0+517.35
0+527.65
0+532.69
0+547.07

0+586.22

0+618.40

0+646.44

0+667.10

0+698.73

0+724.33

0+754.01

0+778.37

0+809.21
0+814.19
0+828.57
0+836.81
0+841.01
0+847.92

0+908.94

0+936.66

0+968.24

0+996.26

1+025.21

1+049.85
1+061.79

1+090.06

1+126.19
1+131.49
1+137.34

1+194.33

1+218.13

1+246.17

1+278.80
1+286.28

1+321.57

1+375.25

1+394.47

1+426.83

1+497.36
1+503.83
1+508.79
1+519.43

1+568.51

1+598.05

1+626.46
1+636.97
1+646.69

1+659.08

1+674.16

1+702.58

1+731.51

1+750.00
CUMULATIVE CHAINAGE
(KM METERS)
(000 + 000)

CLASS / ZONE CLASS / ZONE

DESIGN FACTOR
G WALL THICKNESS (mm) G

OD (mm) / MATERIAL AND GRADE

DESIGN CUMULATIVE CHAINAGE


(KM METERS)
( 000 + 000 )
SPECIAL PROVISIONS
F F
PIPE LINE COVER
MINIMUM ( METERS)
SPECIAL INSTALLATIONS /
FITTING / MARKERS
CS - 002

CS - 003

CS - 004

CS - 005

CS - 002

CS - 007
CS - 001

CTR

FC
CROSSINGS P P

E E

COATING
CATHODIC PROTECTION
INSTALLATIONS

SOIL RESISTIVITY @ 150MM (OHM-M)


0.0
DEPTH IN 'm'

D D

(CH.1000)

(CH.1750)
(CH.1250)
BH NO 1

BH NO 2

BH NO 3

BH NO 4

BH NO 5

BH NO 6

BH NO 7

BH NO 8
(CH.1520)
(CH.500)
(CH.250)

1.0
(CH.750)
(CH.5)

SOIL STRATIFICATION 2.0

3.0

TOPOGRAPHIC SYMBOLS PIPELINE SYMBOLS SOIL SYMBOLS NOTES : BILL OF MATERIAL FOR THIS DRAWING REFERENCE DRAWINGS PROJECT TITLE:
TREE
PROPOSED PIPELINE
BRIDGE / CULVERT
UNCASED CROSSING
CLAY HIGH PLASTICITY 1. ALL dimentions are in metres unless mentioned. DRAWING TITLE DRAWIMG. NO.
MADANAM CPF & PIPELINES PROJECT
EXISTING PIPELINE CASED CROSSING
SLITY CLAY 2. For crossing details refer specific Crossing drawing. (CAUVERY ASSET)
TURNING POINT (TP) POWER LINE ROUTE MAP SCALE (1.50000) TPL/23U4/05/28/M/1024 (SH. 01 OF 01)
C CONTINUOUS CONCRETE 3. All levels are with respect to M.S.L. C
ROAD TELEPHONE LINE
WEIGHTING
GRAVEL - SAND -CLAY MIX (GC) PUTHUR - PAZHAYAR ROAD CROSS SECTION TPL/23U4/05/28/M/1023 (SH. 01 OF 84) CLIENT:
HIGH TENTION LINE
4.The coordinates indicated at GPS satation are in UTM.
RCC ROAD PUDUMANNIYAR RIVER CROSS SECTION
RAILWAY OFC LINE
CONCRETE BLOCKS
GRAVEL - SAND - SILT MIX (GM)
5. KM markers shall be installed at every one Km interval and NALA CROSS SECTION
TPL/23U4/05/28/M/1023 (SH. 02 OF 84)
TPL/23U4/05/28/M/1023 (SH. 03 OF 84)
OIL AND NATURAL GAS CORPORATION LTD.
CART TRACK FENCE ZINC GROUNDING CELL GRAVEL - SAND MIX (GP)
other markers shall be installed as per Technical Spec.no. MANNIYAR CHANNEL CROSS SECTION TPL/23U4/05/28/M/1023 (SH. 04 OF 84) ONSHORE ENGG. SERVICES, DELHI
DIVIDER INTERMEDIATE SCRAPER LATERITE (LA) MEC/S/05/21/10 and standard drawings.
SIGNAL POST NALA CROSS SECTION TPL/23U4/05/28/M/1023 (SH. 05 OF 84)
STATION CLAYEY SILT (MI)
NALA / STREAM / CATHODIC PROTECTION TEST 6. Pipline warning signs shall be installed as given blow or 4 INCH ONGC PIPELINE CROSS SECTION TPL/23U4/05/28/M/1023 (SH. 06 OF 84) CONTRACTOR:
STATION SECTIONALISING VALVES as per instruction of EIC.
CANAL / RIVER PEBBLES (PC) ASPHALT ROAD CROSS SECTION TPL/23U4/05/28/M/1023 (SH. 07 OF 84)
B POND POTENTIAL GRADIENT INSULATION JOINT
SAND - CLAY MIX (SC)
NH/SH - 2 Nos PROJECTS LIMITED B
KM STONE CONTROL MAT (PGCM) Rly xing - 2 Nos
SCRAPER TRAP MUMBAI
TRANSFORMER RECTIFIER SAND SILT MIX (SM)
FURLANG STONE Major water xing - 2 Nos
K K.M MARKER
ROW LIMIT SAND (SP)
AC INTEFERANCE MITIGATION For other details refer tecnical Spec. no. SECTION
TEMPLE Zn RIBBON PARALLEL TO PIPE
W PIPELINE WARNING SIGN CLAYEY SILT LOW PL (ML) MEC/S/05/21/10 for Pipeline Markers. LOCATION
GATE - COPOUND WALL ANODE GROUND BED
WEATHERED ROCK (WR) DESIGNED
BUILDING
7. For casing detail, refer relevant document/drawing enclosed elsewhere ALIGNMENT SHEET
EXISTING CABLE / A AERIAL MARKER DRAWN
WELL PIPELINE CROSSING REFUSAL in tender document.
A
HAND PUMP NAVIGABLE WATERWAY
CHECKED 0.00 km to 1.75 km A
HOT BEND (R = 6 D) N (WT) WATER TABLE 8. For other required material , refer relevant Plot Plan , Piping GAD etc. AND
LAMP POST PIPELINE WARNING SIGN VERIFIED
CS CONDUIT FOR OFC 9. Hot bends shall be decided at site after pre - construcion survey. APPROVED SHEET REV
MAN HOLE D D DIRECTION MARKER
OFC PULLING PIT
WATER KUNDI DATE DRG.NO. MDNM/CPF/PL/6072/ALI/001 01 OF 17 0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16