Professional Documents
Culture Documents
03 December 2021
PAGE 1
Content
1 Collaboration 4 3 Support 28
1.1 Meeting Room - Small 4-6P 5 3.1 Concierge & Waiting Area 29
1.2 Meeting Room - Small 5P (D-End Table) 6 3.2 Mail Room / Concierge Store 30
1.3 Meeting Room - Medium 8P 7 3.3 IT Concierge 31
1.4 Meeting Room - Large 14P - Hybrid option available 8 3.4 IT Build Room 32
1.5 Meeting Room - Extra Large 18P 9 3.5 Servery Room 33
1.6 Open Collaboration - Small, High, Seated 10
1.7 Open Collaboration - D-End, Seated 11 4 Facility 34
1.8 Open Collaboration - Booth A 12
1.9 Open Collaboration - Booth B 13 4.1 Secure Lift Lobby & Wayfinding Screen 35
1.10 Open Collaboration - Medium, Seated 14 4.2 Printer Bay 36
1.11 Open Collaboration - Large, Seated/Standing 15 4.3 Wellness - First Aid Room 37
1.12 Open Collaboration - Standing 16 4.4 Wellness - Multifaith Room 38
1.13 Workshop 17 4.5 Wellness - Parents Room 39
1.14 Agile Flex Space 18 4.6 Wellness - Studio 40
1.15 Innovation Room 19 4.7 Storage - Open Plan Store Area 41
1.16 Town Hall - Combinable Rooms 20 4.8 Storage - Store Room 42
1.17 Ante Space 21 4.9 Storage - PPE Store Room 43
4.10 Storage - Furniture Storage 44
PAGE 2
Revisions
1.1 Meeting Room - Small 4-6P 5 2.4 Recording Booth 26 4.14 Community Hub - Large 48
Revision: v1.0 Revision Date: 03/12/2021 Revision: v1.0 Revision Date: 03/12/2021 Revision: v1.0
Revision Date: 03/12/2021
1.2 Meeting Room - Small 5P (D-End Table) 6 2.5 Training Room 27
Revision: v1.0 Revision Date: 03/12/2021 Revision: v1.0 Revision Date: 03/12/2021
1.4 Meeting Room - Large 14P - Hybrid option available 8 3.2 Mail Room / Concierge Store 30
Revision: v1.0 Revision Date: 03/12/2021 Revision: v1.0 Revision Date: 03/12/2021
1.8 Open Collaboration - Booth A 12 4.1 Secure Lift Lobby & Wayfinding Screen 35
Revision: v1.0 Revision Date: 03/12/2021 Revision: v1.0 Revision Date: 03/12/2021
1.10 Open Collaboration - Medium, Seated 14 4.3 Wellness - First Aid Room 37
Revision: v1.0 Revision Date: 03/12/2021 Revision: v1.0 Revision Date: 03/12/2021
1.14 Agile Flex Space 18 4.7 Storage - Open Plan Store Area 41
Revision: v1.0 Revision Date: 03/12/2021 Revision: v1.0 Revision Date: 03/12/2021
1.16 Town Hall - Combinable Rooms 20 4.9 Storage - PPE Store Room 43
Revision: v1.0 Revision Date: 03/12/2021 Revision: v1.0 Revision Date: 03/12/2021
PAGE 3
1 Collaboration
PAGE 4
1.1 Meeting Room - Small 4-6P
Revision: v1.0
Revision Date: 03/12/2021
Density:
• 2.8 - 6.3sqm per position Ergonomics/ OHS specific requirements:
• AS1428.2 accessibility requirements DDA bench height
• Opening clearance
Space Type:
• Enclosed Room with door (not lockable)
Finishes:
• Walls - Painted, whiteboard and acoustic wall panelling
Partitions: • Floor - Carpet Tile
• Solid with glazed panel to front • Ceiling - Base building Grid and Tile
AXONOMETRIC • Solid panel next to door for room booking panel (external)
SCALE : NTS and light switching (internal)
• Clear glazing with low privacy film Security:
• Solid swing door (typical) Glazed Sliding door alternative • None
option.
Signage:
AV, Power & Data: • Meeting room name/number
• 49” Display Screen mounted 100mm from table top edge • Refer to TfNSW Signage Standards for details
• Control Panel for screen sharing
1350mm • Wireless Presentation Other:
MIN. • Table box with HDMI cable • General base build lighting
• Power and Data, USB A & USB C • AV, Power & Data as a guide only, to be design by Services
Engineer
Acoustic Requirements:
• Rw45
• Reverberation: 0.2 to 0.4 - must comply with AS2107:2016
sound level & reverberation times
• Acoustic absorption (panelling) to minimum 2 walls
PLAN • Privacy level: Medium to Confidential
SCALE :NTS • Furniture/ Accessories
• Fixed table to suit room function with flush mounted power/
data outlet(s) and chairs to suit layout
EXEMPLAR FIT OUT LOCATION: ROOM NO TBC, LEVEL 3 MACQUARIE PARK • Chairs - upholstered seat, no arms, on glides
• Whiteboard- magnetic ‘glossy white’ writable wall
mounted panels. Must sit proud of any adjoining panelling.
Whiteboard must be min. H1200 x W1800mm. Magnetic pen/
PAGE 5
1.2 Meeting Room - Small 5P (D-End Table)
Revision: v1.0
Revision Date: 03/12/2021
1000 mm
MIN. • Clear glazing to front
• Solid swing door Ergonomics/ OHS specific requirements:
• AS1428.2 accessibility requirements DDA bench height
• Opening clearance
AV, Power & Data:
• 49” display screen mounted 100mm from table top edge
• Control panel from screen sharing Finishes:
• Wireless presentation • Walls - Painted, whiteboard and acoustic wall panelling
• Table box with power, data & HDMI cable • Floor - Carpet Tile
• Power & data in table box, USB A & USB C • Ceiling - Base building Grid and Tile
• General base build lighting
1500 mm
MIN.
Security:
Acoustic Requirements: • none
• Rw40
• Reverberation: 0.2 to 0.4 - must comply with AS2107:2016
Signage:
PLAN sound level & reverberation times
• Medium privacy film to be applied to clear glazing
SCALE :NTS • Acoustic absorption (panelling) to minimum 2 walls
• Meeting room name/number
• Privacy level: Medium to Confidential
• Refer to TfNSW Signage Standards for details
EXEMPLAR FIT OUT LOCATION: 07.MR.44, LEVEL 7, & 08.MR.31 MACQUARIE PARK
Other:
• AV, Power & Data as a guide only, to be design by Services
Engineer
PAGE 6
1.3 Meeting Room - Medium 8P
Revision: v1.0
Revision Date: 03/12/2021
- Materials:
MIN.
100mm
Partition:
100mm
1500 mm
MIN. • Solid with glazed panel to front Ergonomics/ OHS specific requirements:
• Solid panel next to door for room booking panel (external) • AS1428.2 accessibility requirements DDA bench height
and light switching (internal) • opening clearance
• Clear glazing to front
Finishes:
AV, Power & Data: • Walls - Painted and acoustic wall panelling
• 2 x 65” VC Screen mounted 1250mm FFL • Floor - Carpet Tile
• Cameras located below screen • Ceiling - Base building Grid and Tile
• For ‘hybrid meeting” type, an additional content camera
ceiling mounted directed at the white board wall
Security:
• Control Panel for screen sharing
• none
• Wireless Presentation
• Table box with HDMI cable
• Power and Data in table box, USB A & USB C Signage:
• General base build lighting • Meeting room name/number
• Hearing Loop for 10P and up • Refer to TfNSW Signage Standards for details
• Medium privacy film to be applied to clear glazing
PAGE 7
1.4 Meeting Room - Large 14P - Hybrid option available
Revision: v1.0
Revision Date: 03/12/2021
AXONOMETRIC
SCALE : NTS Space Type: Joinery:
• Enclosed Room with door (not lockable) • N/A
- Equipment:
- Fittings and fixtures:
Partition: - Materials:
1800 mm
• Solid with glazed panel to front
MIN.
• Solid panel next to door for room booking panel (external)
and light switching (internal) Ergonomics/ OHS specific requirements:
• Clear glazing to front • AS1428.2 accessibility requirements DDA bench height
• Solid swing door • Opening clearance
1200 mm
MIN. AV, Power & Data: Finishes:
• 2 x 85” VC Screen mounted 1250mm FFL • Walls/Wall panelling - Painted, whiteboard and acoustic
• Cameras located below screen panels
• Control Panel for screen sharing • Floor - Carpet Tile
• Wireless Presentation • Ceiling - Generally perforated plasterboard (acoustic)
• Table box with HDMI cable
• General base build lighting
Security:
• Power & data in table box, USB A & USB C
• None
• Hearing Loop
• Hybrid option includes: an additional content camera,
integrated with the AV platform & directed at the white Signage:
board wall • Meeting room name/number
PLAN • Refer to TfNSW Signage Standards for details
SCALE :NTS Acoustic Requirements: • Medium privacy film to be applied to clear glazing
• Rw45
• Reverberation: 0.2 to 0.4 - must comply with AS2107:2016 Other:
EXEMPLAR FIT OUT LOCATION: 07.MR.46, LEVEL 7, MACQUARIE PARK sound level & reverberation times • AV, Power & Data as a guide only, to be design by Services
• Acoustic absorption/panelling to minimum 2 wall Engineer
• Privacy level: Medium to Confidential
PAGE 8
1.5 Meeting Room - Extra Large 18P
Revision: v1.0
Revision Date: 03/12/2021
Area: Joinery:
• 70- 75m2 • Not required
- Equipment:
- Fittings and fixtures:
Capacity: - Materials:
• 18 pax (NB: non-COVID capacity)
Furniture/ Accessories:
Density: • Fixed table to suit room function with flush mounted power/
• 3.8 - 4 sqm per position
data table box outlet(s) and chairs to suit layout
• Chairs - upholstered seat, with arms, on glides or castors
Space Type: • Whiteboard (final locations dependant on project) - magnetic
• Enclosed Room with solid door (not lockable) ‘glossy white’ writable wall mounted panels Must sit proud
of any adjoining panelling. Whiteboard must be min. H1200 x
AXONOMETRIC W3000mm to 2 walls. Magnetic pen/eraser holder
SCALE : NTS Partitions • Credenza servery unit (not joinery) as necessary
• Solid with glazed panel to front
• Solid panel next to door for room booking panel (external)
and light switching (internal) Ergonomics/ OHS specific requirements:
1500 mm
• Clear glazing with low privacy film • AS1428.2 accessibility requirements DDA bench height
MIN.
Acoustic Requirements:
• Rw45 Signage:
• Reverberation: 0.2 to 0.4 - must comply with AS2107:2016 • Meeting room name/number
sound level & reverberation times • Refer to TfNSW Signage Standards for details
PLAN • Acoustic absorption to minimum 2 walls - acoustic wall
SCALE :NTS panelling Other:
• Privacy level: Medium to Confidential • General base build lighting
• AV, Power & Data as a guide only, to be design by Services
EXEMPLAR FIT OUT LOCATION: 07.MR.28 LEVEL 7, MACQUARIE PARK Engineer.
PAGE 9
1.6 Open Collaboration - Small, High, Seated
Revision: v1.0
Revision Date: 03/12/2021
Area: Joinery:
• 15-20m2 • Acoustic screening/writable magnetic whiteboard wall
- Equipment:
- Fittings and fixtures:
Capacity: - Materials: Laminate frame, acoustic panelling, gloss
• 2-5 pax (NB: non-COVID capacity)
whiteboard. Whiteboard must sit proud of any adjoining
panelling. Whiteboard must be min. H1200 x W1800mm.
Density: Magnetic pen/eraser holder.
• 3 -10sqm per position
Ergonomics/ OHS specific requirements:
Space Type: • AS1428.2 accessibility requirements DDA bench height
• Open space with work area, partially private/sheltered
Finishes:
Partition: • Floor - Carpet Tile
AXONOMETRIC • N/A
SCALE : NTS
Security:
AV, Power & Data: • none
• Low level GPO to power mobile AV screen
• Power & data (refer to Services details)
Signage:
• General base build lighting
• Joinery ID - refer to TfNSW Signage Standards for details
Furniture/ Accessories:
• Loose round high meeting table at 1050mm, with weighted
pedestal base
• High chairs with upholstered seat, seat at 760(h)mm, no
arms, on glides
• Loose freestanding whiteboard/s on castors
PLAN
SCALE :NTS
EXEMPLAR FIT OUT LOCATION: OPEN WORK ZONE, LEVEL 7, MACQUARIE PARK
PAGE 10
1.7 Open Collaboration - D-End, Seated
Revision: v1.0
Revision Date: 03/12/2021
Area: Joinery:
• 9 - 11m2 • NA - Acoustic screening/writable magnetic whiteboard wall
optional
- Equipment:
Capacity: - Fittings and fixtures:
• 2 - 6 pax (NB: non-COVID capacity)
- Materials:
Furniture/ / Accessories
• Fixed D-shaped table with pedestal base. Laminate top,
Powdercoated base.
• Seated height table top at H720mm
• Chairs - upholstered seat, no arms on glides
PLAN
SCALE :NTS
PAGE 11
1.8 Open Collaboration - Booth A
Revision: v1.0
Revision Date: 03/12/2021
Area: Joinery:
• 3 - 5 m2 • Built in seating and table, with laminated shroud
- Equipment: AV
- Fittings and fixtures:
Capacity: - Materials: upholstered seating, laminate table & shroud
• 2 - 4 pax (NB: non-COVID capacity)
PLAN DIAGRAM
SCALE :NTS SCALE :NTS
PAGE 12
1.9 Open Collaboration - Booth B
Revision: v1.0
Revision Date: 03/12/2021
Area: Joinery:
• 5 m2 • Built in seating and table
- Equipment: AV
- Fittings and fixtures:
Capacity: - Materials: Upholstered back and seat, laminate table &
• 2 - 4 pax (NB: non-COVID capacity)
seat base
PAGE 13
1.10 Open Collaboration - Medium, Seated
Revision: v1.0
Revision Date: 03/12/2021
Area: Joinery:
• 15 - 20 m2 • Fixed writable magnetic whiteboard wall on timber frame
(optional). Whiteboard must be min. H1200 x W1800mm.
Magnetic pen/eraser holder
Capacity: - Equipment:
• 8 pax (NB: non-COVID capacity)
- Fittings and fixtures: integrated GPO/data point
- Materials: gloss magnetic whiteboard/acoustic panel,
Density: timber frame
• 1.9 - 2.5sqm per position
Ergonomics/ OHS specific requirements:
Space Type: • AS1428.2 accessibility requirements DDA bench height
• Open space for presenting and collaboration, partially
screened
AXONOMETRIC Finishes:
SCALE : NTS • Walls finish - None
Partition: • Floor finish - Vinyl or Carpet Tile
• None • Ceiling - Varies - Base Building Grid and Tile or Exposed Slab
with Acoustic Spray
PLAN
SCALE :NTS
PAGE 14
1.11 Open Collaboration - Large, Seated/Standing
Revision: v1.0
Revision Date: 03/12/2021
Area: Joinery:
• 30 - 35m2 • Fixed writable magnetic whiteboard wall on timber frame
(optional). Whiteboard must be min. H1200 x W1800mm.
Magnetic pen/eraser holder
Capacity: - Equipment:
• 16 - 18pax (NB: non-COVID capacity)
- Fittings and fixtures: integrated GPO/data point
- Materials: gloss magnetic whiteboard/acoustic panel,
Density: timber frame
• 1.85 - 2.2 sqm per position
Ergonomics/ OHS specific requirements:
Space Type: • AS1428.2 accessibility requirements DDA bench height
• Open space for presenting and collaboration, partially
AXONOMETRIC
screened
SCALE : NTS Finishes:
• Walls finish - None
AV, Power & Data: • Floor finish - Vinyl or Carpet Tile
• Low level GPO or Floor Box for mobile screen • Ceiling - Varies - Base Building Grid and Tile or Exposed Slab
• Table box with HDMI cable with Acoustic Spray
• Power and Data, USB A & USB C
• Power to Lounge seat base
Security:
• none
Acoustic Requirements:
• None
Signage:
• Meeting room name/number
Furniture/ Accessories: • Refer to TfNSW Signage Standards for details
• Modular upholstered lounge with laminate back ledge/desk
at standing height (1050mm)
Other:
• High stools (750mm seat height) with upholstered seat/
• General base build lighting
back, sled base with slides
• AV, Power & Data as a guide only, to be design by Services
• Round upholstered modular seats/ottomans
Engineer
• Laptop tables of mixed height, 620mm & 720mm
• Locate away from work zones
• Mobile whiteboards on lockable castors
• Low round stool
PLAN • Loose free-standing whiteboard/s on castors
SCALE :NTS
PAGE 15
1.12 Open Collaboration - Standing
Revision: v1.0
Revision Date: 03/12/2021
PLAN Other:
SCALE :NTS • General base build lighting
• AV, Power & Data as a guide only, to be designed by Services
Engineer
EXEMPLAR FIT OUT LOCATION: L6, THE STORE, 6 STEWART AVE, NEWCASTLE
PAGE 16
1.13 Workshop
Revision: v1.0
Revision Date: 03/12/2021
1.13 Workshop
Open space for intensive small to medium team collaboration work and pin ups.
Medium to long term use, bookable.
PAGE 18
1.15 Innovation Room
Revision: v1.0
Revision Date: 03/12/2021
Density: Joinery:
• 2.5sqm per position (14p) • NA (unless specified to specific rooms i.e on shared meeting
floor)
Space Type: - Equipment:
• Enclosed Room with door (not lockable) - Fittings and fixtures:
- Materials:
AXONOMETRIC
SCALE : NTS Partitions:
• Solid with glazed panel to front with solid panel (external) Ergonomics/ OHS specific requirements:
and light switching (internal) next to door for room booking • AS1428.2 accessibility requirements DDA bench height
panel. • Opening clearance
• Clear glazing to front
Finishes:
AV, Power & Data: • Walls/ Wall panelling - Painted, whiteboard and acoustic
• 85” Interactive Screen mounted 780mm FFL. panels
• Floor boxes for laptop charging to allow for flexible work • Floor - Carpet Tile
settings • Ceiling - Base building Grid and Tile
• General base build lighting
• Allow for additional GPO outlets at low level throughout the Security:
room for mobile screens when required • None
Area: Joinery:
• 60 - 80m2 • Kitchen refresh joinery
• Equipment: ZIP filtered/chilled/hot water unit,
• 2 x dish drawer dishwasher
Capacity: • Fittings and fixtures: paper towel dispenser,
• 28 - 40 pax (NB: non-COVID capacity)
• double sink, integrated 3-stream bin drawer
• Materials: laminate joinery, solid surface
Density: • benchtop & splashback
• 1.5 - 2.8sqm per position • Touchdown benchtop with integrated planter and bin
drawers. Fixed bench with integrated planter and bench
seating
Space Type: • Equipment: N/A
• Semi-enclosed space with no door - Fittings and fixtures: Power outlet above benchtop;
AXONOMETRIC
- Power below bench seats & 3-stream waste bins
SCALE : NTS
Partition: - Materials: laminate finish with galvanised steel planter
• Solid partition
Ergonomics/ OHS specific requirements:
AV, Power & Data: • AS1428.2 accessibility requirements DDA bench height
• Power outlet to banquette base & above benchtop for laptop • Opening clearance
charging
Finishes:
Acoustic Requirements: • Walls - Painted & decorative panelling
• Must comply with AS2107:2016 sound level & reverberation • Floor - Vinyl & inset carpet tile
times • Ceiling - Exposed slab & plasterboard
• Privacy level: Low
Security:
Furniture/ Accessories • None
• Standing (1050mm) and sitting (720mm) height
• Upholstered bar stools and low stools (seat height 750mm / Signage:
350mm) with no back, on carpet slides • Joinery ID Signage, refer to TfNSW Signage Standards for
• Upholstered bar barstool with back rest, seat height 610mm, details
on carpet slides
• Upholstered armchairs, on carpet slides
PLAN • Pedestal base coffee table, 420dia, 400mm height Other:
SCALE :NTS • Not bookable
• AV, Power & Data as a guide only, to be design by Services
Engineer
EXEMPLAR FIT OUT LOCATION: OUTSIDE 08.MR.01, LEVEL 8, MACQUARIE PARK • Adjacent to Town Hall space
• Feature pendant and wall lighting optional
PAGE 21
2 Task Oriented
PAGE 22
2.1 Focus Room
Revision: v1.0
Revision Date: 03/12/2021
Area: Joinery:
• 5.5-7.5 m2 • N/A
- Equipment:
- Fittings and fixtures:
Capacity: - Materials:
• 1 pax
Furniture/ Accessories:
• Task chair
• Workstation type bench Fixed or Adjustable (sit to stand)
PLAN workstations, of sufficient depth to place laptop on
SCALE :NTS • 50/50 split fixed/adjustable, to be reviewed on project basis
• Refer to TfNSW workstation standards for details
• Workstation finish strategy below;
EXEMPLAR FIT OUT LOCATION: 08.FR.27, LEVEL 8, MACQUARIE PARK - Fixed Desk to have a white laminate table top
- Sit to Stand desk to have a wood look laminate table top
PAGE 23
2.2 Quiet Carriage - Type A/B
Revision: v1.0
Revision Date: 03/12/2021
Area: Joinery:
• 240 - 250m2 • N/A
- Equipment:
- Fittings and fixtures:
Capacity: - Materials:
• 48-54 pax (NB: non-COVID capacity)
Other:
Acoustic Requirements: • Not bookable
• Rw45
• Individual desk bookings
• Sound Reverberation 0.6 to 0.8
• AS2107:2016 sound level & reverberation times
• Acoustic absorption to minimum 2 walls
• Privacy level: Low
Furniture/ Accessories:
• Task chair
PLAN • Workstation type bench Fixed or Sit to Stand desk
SCALE :NTS (sufficient depth to place laptop on)
• Workstation finish strategy below;
- Fixed Desk to have a white laminate table top
EXEMPLAR FIT OUT LOCATION: ROOM #, LEVEL 3, MACQUARIE PARK - Sit to Stand desk to have a wood look laminate table top
• Focus Workstation with visually/acoustically private
upholstered screens
PAGE 24
2.3 Tender Evaluation
Revision: v1.0
Revision Date: 03/12/2021
Partition:
• Solid with glazed panel to front Ergonomics/ OHS specific requirements:
• Solid panel next to door for room booking panel (external) • AS1428.2 accessibility requirements DDA bench height
AXONOMETRIC • Opening clearance
and light switching (internal)
SCALE : NTS
• Solid swing door
Finishes:
AV, Power & Data: • Walls/Wall panelling - Painted, whiteboard and acoustic
• Power and data to workstations via floor recessed boxes. panels
• Power and Data, USB A & USB C • Floor - Carpet Tile
• Room booking panel • Ceiling - Base building Grid and Tile
• General base build lighting
Security:
1800mm Acoustic Requirements: • Lockable with swipe card access (Restricted Access)
MIN.
• Rw50
• Reverberation: 0.6 to 0.8 - must comply with AS2107:2016
sound level & reverberation times
Signage:
• Meeting room name/number
• Acoustic absorption/panelling to minimum 1 wall
• Refer to TfNSW Signage Standards for details
• Privacy level: Confidential
• High privacy film to be applied to clear glazing
• Room name/number
MIN.
PAGE 26
2.5 Training Room
Revision: v1.0
Revision Date: 03/12/2021
Density: Joinery:
• Wall mounted presenter credenza with drawers
• 3.6 - 4.5 sqm per position
- Equipment:
- Fittings and fixtures: top mounted GPO
AXONOMETRIC Space Type: - Materials: laminate
SCALE : NTS • Enclosed Room with door (not lockable) • Full height open shelving for personal belongings
- Equipment:
Partition: - Fittings and fixtures: top mounted GPO
• Solid panel next to door for room booking panel (external) - Materials: laminate
and light switching (internal)
• Clear glazing with medium privacy film Ergonomics/ OHS specific requirements:
• Operable wall • AS1428.2 accessibility requirements DDA bench height
• Opening clearance
AV, Power & Data:
• 85” display screen, wall mounted at height 1300mm AFF Finishes:
• Video camera mounted under display 1200mm AFF • Walls / wall panels - Painted, whiteboard and acoustic wall
• Presenter camera mounted on rear wall, at 2100mm AFF panelling
XXmm XXmm • Table box with power, data & HDMI cable • Floor - Carpet Tile
• Power & data in table box, USB A & USB C • Ceiling - Base building Grid and Tile
• 10” AV touch control, wall mounted beside screen
• Movable 50” interactive display, on castors
• Ceiling mounted microphone and loud speakers Security:
• Hearing loop • none
1400mm
1400mm
MIN.
MIN.
PAGE 28
3.1 Concierge & Waiting Area
Revision: v1.0
Revision Date: 03/12/2021
Area: Joinery:
• 200-450m2 • Concierge Pods - freestanding concierge pods (sit to stand)
*Note: areas will vary dependent on location - Equipment: fixed 24” monitor on arm
- Fittings and fixtures: lockable drawer, integrated desk
lamp, power/data supply
Capacity: - Materials: Timber veneer top on powdercoat steel base
• 20-60 pax (NB: non-COVID capacity)
• Touchdown bench & low seating with integrated planters
- Equipment: none
Density: - Fittings and fixtures: waterproof planter, power/data points
• 3.5- 20sqm per position to seat back
- Materials: laminate frame, upholstered seat cushions,
stainless steel planter trough
AXONOMETRIC Space Type:
SCALE : NTS • Open area, no door
Ergonomics/ OHS specific requirements:
• AS1428.2 accessibility requirements DDA bench height
Partition: • Opening clearance
• None
Finishes:
AV, Power & Data: • Walls - Painted or Feature Wall Panel
• Power & data to Concierge Pod • Floor - LVT
• Promotional display screen • Ceiling - Perforated set plasterboard
• Check-In Kiosks
Security:
Acoustic Requirements: • none
• None (open space)
• Must comply with AS2107:2016 sound level & reverberation
time Signage:
• Privacy level: Low • Room name/number
• Opening hours
• Directional Map
Furniture/ Accessories • Acknowledgement of Country
• Drafting Chair for the Concierge Pods • Refer to TfNSW Signage Standards for details
• A mix of casual seating to suit the space;
• Upholstered lounge chair with arms, on swivel base,
PLAN powdercoated legs Other:
SCALE :NTS • Upholstered modular lounge with low or high back, on • Concierge to be visible on arrival
powdercoated base • Feature Lighting above Concierge
• Round coffee table, dia.700mm, timber laminate top on • Adjacent to Mail Room/ Concierge Store with Printer
EXEMPLAR FIT OUT LOCATION: ROOM NO, LEVEL 1, MACQUARIE PARK weighted pedestal base • Adjacent to Speedstiles and Lifts
• Square & rectangular powdercoated steel planters, no
drainage holes, on stainless steel castors, various sizes
PAGE 29
3.2 Mail Room / Concierge Store
Revision: v1.0
Revision Date: 03/12/2021
Area: Joinery:
• 17-20m2 • Layout bench with storage cupboards and drawers below.
1800mm tall storage unit (full height optional) for stationary,
general storage. Adjustable open shelving.
Capacity: - Equipment: see furniture/accessories
• 1 - 2 pax
- Fittings and fixtures:
- Materials: Laminate with Pinboard
Density:
• 8.5- 20 sqm per position
Ergonomics/ OHS specific requirements:
• AS1428.2 accessibility requirements DDA bench height
Space Type: • Opening clearance
• Enclosed Room (lockable - swipe card access)
Finishes:
Partition: • Walls - Painted
• Solid partitions, with light switching (internal) • Floor - Carpet Tile
• Solid swing doors, swipe card access panel to external • Ceiling - Base building Grid and Tile
partition
AXONOMETRIC
SCALE : NTS Security:
AV, Power & Data: • Locking, swipe card access
• Above bench GPO
• Power and Data for MFD photocopier
Signage:
• General base build lighting
• Room name/number
• Joinery ID Signage
Acoustic Requirements: • Refer to TfNSW Signage Standards for details
1500mm
• Rw40
MIN.
Furniture/ Accessories:
• MFD photocopier (allow sufficient servicing area around the
copier as required by the manufacturer)
PLAN • Note: Fuji Xerox MFD min space is 3.2m per unit
SCALE :NTS • 2 x 240L bins (recycle/ secure)
• Space for 1 x bin for toner recycling (supplied by supplier)
• Bench space
EXEMPLAR FIT OUT LOCATION: ROOM NO, LEVEL 1, MACQUARIE PARK
PAGE 30
3.3 IT Concierge
Revision: v1.0
Revision Date: 03/12/2021
3.3 IT Concierge
Open, service desk for IT Assistance. Ergonomically set up for IT staff
to work at full time.
Area: Joinery:
• 20-25m2 • Optional full height Storage Cupboards (lockable) with
adjustable shelves.
- Equipment:
Capacity: - Fittings and fixtures:
• 2 - 4 pax (NB: non-COVID capacity)
- Materials:
Partition: Finishes:
• Open Area
• Floor - Carpet Tile
• Ceiling - Base building Grid and Tile
AXONOMETRIC Space Type:
SCALE : NTS • Open space with work area
Security:
• None
AV, Power & Data:
• 49” Display Screen mounted on the wall near by
Signage:
• Wireless Presentation
• Refer to TfNSW Signage Standards for details
• General base build lighting
• Power and data to workstations
Other:
• Adjacent to open work zones
Acoustic Requirements: • Centrally located in the floor plate and stack if the fit out is
• N/A
over multiple floors
• Privacy level: low
• Located near IT build room
PAGE 31
3.4 IT Build Room
Revision: v1.0
Revision Date: 03/12/2021
Partition: Signage:
• Solid partitions with light switching (internal) next to solid
• Room name/number
swing door
• Refer to TfNSW Signage Standards for detail
• Solid swing doors with Hold Open
AXONOMETRIC Other:
AV, Power & Data: • Coordinate joinery with services (power and data)
SCALE : NTS • Power & Data Rail
requirements
• General base build lighting
• Capacity provided for working on a maximum of 5 PCs at
one time
Acoustic Requirements: • Adjacent to IT Help Desk
• Rw40
• AS2107:2016 sound level & reverberation times
• Privacy level: Low
Furniture/ Accessories
• Open heavy duty high metal shelving (consideration of
dimensions to suit size of equipment) & storage of boxes
• Adjustable ergonomic task chair to suit joinery bench unit
• Lockable high cupboard
PLAN Joinery:
SCALE :NTS • Bench unit at 750mm height with space for working on
laptops
- Equipment: TBC
- Fittings and fixtures: GPOs/data to bench
EXEMPLAR FIT OUT LOCATION: ROOM NO, LEVEL TBC, STORE
- Materials: laminate
PAGE 32
3.5 Servery Room
Revision: v1.0
Revision Date: 03/12/2021
Area: Joinery:
• 20 - 30 m2 • Fixed bench space with overhead shelving and underbench
cupboards.
- Equipment: ZIP filtered/chilled/hot water unit, free
Capacity: standing dishwasher x 2., glass washer, reheat oven,
• 2 - 5 pax (NB: non-COVID capacity)
microwave, ice machine, glass door double fridge, glass
door single glass door freezer
Density: - Fittings and fixtures: wall mounted paper towel dispenser,
• 4 - 15sqm per position large single sink with extendible tap for cleaning,
integrated 3-stream bin drawer (optional), integrated soap
dispenser
Space Type: - Materials: laminate joinery, solid surface benchtop &
• Enclosed Room splashback
Signage:
Furniture/ Accessories: • Room
• Catering Trolley x 2 • Refer to TfNSW Signage Standards for details
• freestanding waste bins on wheels
Other:
PLAN • Kitchen appropriate smoke sensors
SCALE :NTS • Services as required for equipment
• Adjacent to the Townhall
• This is a reheat kitchen only and does not require services
EXEMPLAR FIT OUT LOCATION: 08.SV.15, LEVEL 8, MACQUARIE PARK designed for a commercial kitchen (eg exhaust)
PAGE 33
4 Facility
PAGE 34
4.1 Secure Lift Lobby & Wayfinding Screen
Revision: v1.0
Revision Date: 03/12/2021
Capacity: Joinery:
• 15 -30 pax (variable based on project) • N/A
- Equipment:
Density: Area: - Fittings and fixtures:
• 1- 5m2 (variable based on project) - Materials:
PLAN
SCALE :NTS
PAGE 35
4.2 Printer Bay
Revision: v1.0
Revision Date: 03/12/2021
Area: Joinery:
• 6-8m2 approx • Shroud around utilities, layout bench with inset stationary
tray on top and double door storage cupboards below
(approx. 1000mm internal width of underbench cupboard
Metric: min. x600mmD)
• 2-4 per typical work floor
- Equipment: see furniture/accessories
- Fittings and fixtures: inset stationary organiser
Density: - Materials: laminate
• 4.0 - 8.0sqm per position
Ergonomics/ OHS specific requirements:
• AS1428.2 accessibility requirements DDA bench height
Space Type:
• Semi enclosed space with entry top/bottom (no doors)
Finishes:
• Walls/Wall panelling - N/A
Partition:
• Floor- carpet tile or vinyl
• N/A
• Ceiling - Base building Grid and Tile
PLAN
SCALE :NTS
PAGE 36
4.3 Wellness - First Aid Room
Revision: v1.0
Revision Date: 03/12/2021
Area: Joinery:
• 15-17m2 • Kitchenette joinery unit with lockable storage cabinets for
medicine & sharps
- Equipment: ZIP filtered/chilled/hot water unit, bar fridge,
Capacity: microwave, sharps disposal system
• 1 - 2 pax
- Fittings and fixtures: integrated paper towel dispenser,
single sink with mixer tap, integrated bin drawer,
Density: integrated soap dispenser
• N/A - Materials: laminate joinery, solid surface benchtop &
splashback
Space Type:
• Enclosed Room with solid door (lockable) Ergonomics/ OHS specific requirements:
• Preferably with natural light (i.e. room located along • AS1428.2 accessibility requirements DDA bench height
perimeter wall) • First Aid kit/s (number dependant on size of workplace)
• Opening clearance
ELEVATION AXONOMETRIC
SCALE :NTS SCALE : NTS Partition:
• Solid painted partition. Light switching next to door (internal) Finishes:
• Solid lockable door • Walls- Painted
• Floor- Resilient floor
• Ceiling - Base building Grid and Tile
AV, Power & Data:
• Power & Data maybe required for charging equipment - refer
to Services details Security:
• Power for lamp & task light • Lockable
• General base build lighting • Privacy snib lock
PAGE 37
4.4 Wellness - Multifaith Room
Revision: v1.0
Revision Date: 03/12/2021
Area: Joinery:
• 24-27m2 • Not required
- Equipment:
- Fittings and fixtures:
Capacity: - Materials:
• 1 - 4 pax
PAGE 38
4.5 Wellness - Parents Room
Revision: v1.0
Revision Date: 03/12/2021
Area: Joinery:
• 10 -11m2 • Kitchenette joinery unit with lockable storage cabinets
- Equipment: ZIP filtered/chilled/hot water unit, bar fridge,
microwave
Capacity: - Fittings and fixtures: integrated paper towel dispenser,
• 1 - 2 pax
single sink with mixer tap, integrated bin drawer,
integrated soap dispenser
Density: - Materials: laminate joinery, solid surface benchtop &
• N/A splashback
PAGE 39
4.6 Wellness - Studio
Revision: v1.0
Revision Date: 03/12/2021
Area: Joinery:
• 110-120m2 • Change Room Partition System and Lockers
- Equipment:
- Fittings and fixtures:
Capacity: - Materials:
• 10 - 15 pax
ENTRY
AV, Power & Data: Security:
• Power & data (refer to Services details) • Swipe card access (not lock and key)
• General base build lighting - may be required to be dimable
• 65” Display Screen wall mounted
Signage:
• Speakers integrated into ceiling
• Room name/number
• Hearing Loop
• Refer to TfNSW Signage Standards for details
Furniture/ Accessories
• Bench seat with open storage for personal belongings
• Planters & Plants
PLAN
SCALE :NTS
PAGE 40
4.7 Storage - Open Plan Store Area
Revision: v1.0
Revision Date: 03/12/2021
Area: Joinery:
• 3 - 4m2 • 1800mm tall storage unit (full height optional) for stationary,
general storage, coat closet and hygiene station with bins
- Equipment:
Capacity: - Fittings and fixtures: coat rail and 3-stream bin inset
• approx. 6.5sqm internal capacity
- Materials: laminate
Furniture/ Accessories:
• N/A
Bin Drawers
ELEVATION
SCALE :NTS
EXEMPLAR FIT OUT LOCATION: OPEN WORK ZONES, LEVEL 7, MACQUARIE PARK
PAGE 41
D
FN:02
08
08
09
4.8 Storage - Store Room
FN:34a
FN:154
Revision: v1.0
x4
x4
7
FN:60
4.8 Storage - Store Room
FOCUS
FN:01
SY:04
07.11
FN:11b
x8 SY:01
FN:01
Enclosed room for storage items. Short term access/use.
FN:13a
FN:10b Area: Ergonomics/ OHS specific requirements:
FN:12c
FOCUS
• Approx. 16 - 18m2 • Opening clearance
FN:12c FN:57a
FN:57a
FN:10b
FN:58a
*Note: areas will vary dependent on location. Room
07.10
FN:01
SY:06
dimensions to suit efficient storage unit layout
Finishes:
FN:61
FN:12c
• Walls - Painted
Capacity: • Floor - Carpet Tile
FN:61
• N/A • Ceiling - Base building Grid and Tile
9000
Metric: Security:
• Nominate 1 x per typical floor • Swipe card access (not lock and key)
FN:01
x4
FN:01
x4
UTILITY/ LOCKERS
Space Type: Signage:
CW:21
SY:03
• Refer to TfNSW Signage Standards for details
Partitions:
SY:09
AXONOMETRIC
• Solid partitions. Light switching next to door (internal) Other:
07.09
SCALE : NTS
• Solid lockable swing door • Not bookable
• AV, Power & Data as a guide only, to be design by Services
Engineer
AV, Power & Data:
• Power & Data maybe required for charging equipment - refer
to Services details
CW:20
Acoustic Requirements:
8
• N/A
• Privacy level: Normal
FN:01
x8
Furniture/ Accessories (minimum requirements):
• Modular metal open high shelving, 2100H max. Open
adjustable shelving. Each room layout to be reviewed per
floor by TfNSW
SY:01
• Note: furniture store rooms may not require any shelving
(furniture, equipment or box store only)
CW:02
PLAN Joinery:
SCALE :NTS • Not required
*Note: specific room may require some built in joinery TBC.
- Equipment:
EXEMPLAR FIT OUT LOCATION: 07.ST.51, LEVEL 7, MACQUARIE PARK - Fittings and fixtures:
9000
- Materials:
FN:102 x5
x8
FN:01
PAGE 42
4.9 Storage - PPE Store Room
Revision: v1.0
Revision Date: 03/12/2021
Area: Joinery:
• 12 - 14m2 • Open joinery unit with bench seat and mix of adjustable
shelves and some coat rails. Provide fixed whiteboard panel
at the top of shelves to assign to teams names
Capacity: - Equipment:
• N/A
- Fittings and fixtures:
- Materials: Laminate, glossy magnetic whiteboard
Metric:
• Nominate 1 x office fit out
Ergonomics/ OHS specific requirements:
• Opening clearance
Space Type:
• Enclosed Room with door (lockable)
Finishes:
• Walls - Painted
Partition: • Floor - Carpet Tile
AXONOMETRIC • Solid partitions. Light switching next to door (internal) • Ceiling - Base building Grid and Tile
SCALE : NTS • Solid lockable swing door
Security:
AV, Power & Data: • Swipe card access (not lock and key)
• Power & Data maybe required for charging equipment - refer
to Services details
Signage:
• General base build lighting
• Room name/number
• Refer to TfNSW Signage Standards for details
Acoustic Requirements:
• N/A
Other:
• Privacy level: Normal
• not bookable
• AV, Power & Data as a guide only, to be design by Services
Furniture/ Accessories (minimum requirements): Engineer
• N/A
PLAN
SCALE :NTS
PAGE 43
4.10 Storage - Furniture Storage
Revision: v1.0
Revision Date: 03/12/2021
Area: Joinery:
• 15-20m2 • N/A
*Note: areas will vary dependent on location - Equipment:
- Fittings and fixtures:
- Materials:
Capacity:
• N/A
Ergonomics/ OHS specific requirements:
• AS1428.2 accessibility requirements DDA bench height
Density: • Opening clearance
• N/A
Finishes:
Space Type: • Walls - Painted
• Enclosed Room (lockable - swipe card access)
• Floor - Carpet Tile
• Ceiling - Base building Grid and Tile
Partition:
• Solid partitions with light switching (internal) next to solid
AXONOMETRIC
Security:
swing door
• Swipe card access (not lock and key)
SCALE : NTS • Double solid swing doors with Hold Open
Signage:
AV, Power & Data: • Room name/number
• Power & data may be required for charging equipment
• Refer to TfNSW Signage Standards for details
• General base build lighting
Other:
Acoustic Requirements: • Adjacent to Townhall or Multifunctional Rooms (preferable)
• None
• Sound Reverberation - N/A
• AS2107:2016 sound level & reverberation times
Furniture/ Accessories
• Metal open high shelving (optional)
• Note: furniture store rooms may not require any shelving
(furniture, equipment or box store only)
PLAN
SCALE :NTS
PAGE 44
4.11 Refresh / Hydration Point
Revision: v1.0
Revision Date: 03/12/2021
Area: Joinery:
• 3 - 4 m2 • Refresh / Hydration joinery
- Equipment: ZIP filtered/chilled/hot water unit with drip
base
Capacity: - Fittings and fixtures: integrated bin drawer - general waste
• 1 pax (NB: non-COVID capacity)
and recycling
- Materials: laminate joinery, solid surface benchtop
Density:
• 3 - 4 sqm per position
Ergonomics/ OHS specific requirements:
• AS1428.2 accessibility requirements DDA bench height &
Space Type: DDA accessible sink.
• Open area, walk through
Finishes:
Partition: • Floor - Resilient flooring
• N/A • Ceiling - Base building Grid and Tile
PLAN
SCALE :NTS
PAGE 45
4.12 Community Hub - Small
Revision: v1.0
Revision Date: 03/12/2021
Area: Joinery:
• 11-13 m2 • Kitchen refresh joinery
- Equipment: ZIP filtered/chilled/hot water unit, double dish
drawer dishwasher, 501L upright fridge
Capacity: - Fittings and fixtures: paper towel dispenser, double sink,
• 2 - 3 pax (NB: non-COVID capacity)
integrated 3-stream bin drawer
- Materials: laminate joinery, solid surface benchtop &
Density: splashback
• 3.6 - 6.5 sqm per position
Ergonomics/ OHS specific requirements:
Space Type: • AS1428.2 accessibility requirements DDA bench height &
• Open area, walkthrough DDA accessible sink.
• Allow for access crockery/cutlery storage at DDA suitable
height
Partition: • First Aid Kit stored in an easy to access location, clearly
• N/A signposted
AXONOMETRIC
SCALE : NTS AV, Power & Data: Finishes:
• Power & data (refer to Services details) • Walls - Painted
• General base build lighting • Floor - Resilient flooring
• Ceiling - Base building Grid and Tile & Specialty ceiling (refer
Acoustic Requirements: to ceiling schedule)
• None - open
Security:
Furniture/ Accessories: • none
• N/A
1500mm
Signage:
MIN.
Other:
• Not bookable
• AV, Power & Data as a guide only, to be design by Services
Engineer
PLAN
SCALE :NTS
PAGE 46
4.13 Community Hub - Medium)
Revision: v1.0
Revision Date: 03/12/2021
Area: • High stools to suit benches with full Upholstered banquette seating with
• 560 - 600 m2 height backs integrated planter
• Mix of round & square pedestal base - Equipment: None
dining tables. 700-900mm diameter/ - Fittings and fixtures: GPOs
Capacity: 900x900mm square, at 750mm integrated into upstand
• 180 - 220 pax height. - Materials: Laminate, vinyl
• Various dining chairs, seat height upholstered back and seat
Density: 450mm, with and without arms cushions, galvanised steel planter
• 2.5 -3.5sqm (NB: non-COVID • Banquette joinery; alternatively trough with waterproof lining
capacity) bench seat with upholstered vinyl
AXONOMETRIC seat pad, full height back rest, seat
SCALE : NTS height 450mm
Ergonomics/ OHS specific
Space Type: • Large dining table(s) for bookable requirements:
• Open space, partially separated areas • AS1428.2 accessibility requirements
from surrounding workspaces by DDA bench height
partitions and fixed full height • Kitchen Joinery (typical): • First Aid Kit stored in an easy to
joinery adjoining external glazing Provide duplicate kitchen settings access location, clearly signposted
as required for capacity, increase
proportionately for larger Hub types.
bookable dining Partition: Finishes:
For every approx. 60 people provide
space for 18pax • Solid partitions, no door • Walls - Painted and wall graphic
1 full height joinery piece + 1 double
• Floor - Resilient vinyl flooring
sided island piece.
• Ceiling - Suspended plasterboard &
AV, Power & Data: - 1x full height joinery piece
sprayed exposed slab
• Power (for cleaner) mounted at low contains: 1x double sink; 2x
height around room perimeter - refer microwaves; 4x upright fridges;
to Services details storage Security:
• General base build lighting - 1x double sided island piece • None
• Room booking panels for bookable contains: 2x double sinks
dining (including 1 accessible); 2 dish
• 49” Display Screen mounted on the drawer dishwashers, 2x toasters;
Signage:
• Joinery ID - refer to TfNSW Signage
wall with Free to Air TV 2x sandwich press; storage
Standards for details
bookable dining - Equipment: ZIP filtered/chilled/
space for 22 pax hot water unit, integrated single
Acoustic Requirements: dish drawer dishwasher. To full Other:
• None - open height sections only: multiple 501L • Feature light pendant over kitchen
• Acoustic insulation spray (with upright fridges and microwaves
PLAN counter & furniture settings - refer to
paint finish) applied to underside of - Fittings and fixtures: integrated
SCALE :NTS Services details
exposed slab over seating area paper towel dispenser, double sink, • Kitchen appropriate smoke sensors
• Privacy level: Low integrated 3-stream bin drawer, • Allow for space for vending
integrated soap dispenser machine(s)
EXEMPLAR FIT OUT LOCATION: LEVEL 8 (MOUNTAIN ZONE), MACQUARIE PARK
Furniture/ Accessories: - Materials: laminate joinery, solid • Planting
• 8P high benches (H1050mm) with surface benchtop & splashback • AV, Power & Data as a guide only, to
laminate top & lockable casters • Banquette Joinery: be design by Services Engineer
PAGE 48
PAGE 49