You are on page 1of 1

IS 269 :2015

J.K.SUPER CEMENT
J.K.CEMENT WORKS-NIMBAHERA

CM/L - 8217772

J.K.Cement Works Quality Control Laboratories


Kailash Nagar No.1- 312617
NIMBAHERA, Dist.-Chittorgarh (RAJ.),
Phone-01477-220087, 220098, 220562, E-mail: jkc.nbh@jkcement.com
TC-6535
INTERIM TEST REPORT
Description : 43 Grade Ordinary Portland Cement as per IS:269:2015
Customer Name & Address : Packing Plant JKCW-NBH/Marketing Sample ID : 43-OPC/W-49/97
Unique Lab Report : TC6535220000000220F Sample received date : 10.12.2022
Date of Performance of Testing : 10.12.2022 to 17.12.2022 Date of reporting : 17.12.2022
Location of Test Performed : Chemical Lab & Mechanical Lab Description of Sample : 24kg(approx.)
The test report pertains to the average sample of week no. : 49 ( 03.12.2022 to 09.12.2022 )
CHEMICAL ANALYSIS OF CEMENT:
S.NO SAMPLE TEST TYPE [UOM] TEST REQUIRMENT as IS METHOD
RESULTS per IS 269:2015
1 LOI [%] 3.41 Max. 5.0 IS: 4032:1985
2 Insoluble Residue [%] 3.10 Max. 5.0 IS: 4032:1985
3 SO3 [%] 2.57 Max. 3.5 IS: 4032:1985
4 MgO [%] 0.99 Max. 6.0 IS: 4032:1985
5 Total Alk. as Na2O** [%] 0.43 - IS: 4032:1985
6 Chloride [%] 0.030 Max. 0.1 IS: 4032:1985
7 LSF = [CaO -(0.7xSO3)/ 0.86 0.66-1.02 -
((2.8xSiO2)+(1.2xAl2O3)+(0.65xFe2O3))]
8 A/F = [(Al2O3/Fe2O3)] 1.37 Min. 0.66 -
9 Performance Improver (Lime Stone) [%] 4.96 Max. 5.0 -
MECHANICAL TESTS OF CEMENT:
1 Fineness [M2/Kg] 280.00 Min. 225 IS: 4031 P-2: 1999
2 Standard Consistency [%] 28.00 - IS: 4031 P-4: 1988
3 Soundness
a Le-Chatelier [mm] 1.00 Max. 10.0 IS: 4031 P-3: 1988
b Autoclave Expansion [%] 0.03 Max. 0.8 IS: 4031 P-3: 1988
4 Setting time
a Initial Setting Time [Minute] 140.00 Min. 30 IS: 4031 P-5: 1988
b Final Setting Time [Minute] 180.00 Max. 600 IS: 4031 P-5: 1988
5 Compressive Strength
a 3 Days (72 ± 1 Hrs.) [Mpa] 33.50 Min. 23 IS: 4031 P-6: 1988
b 7 Days (168 ± 2 Hrs.) [Mpa] 43.00 Min. 33 IS: 4031 P-6: 1988
c 28 Days (672 ± 4 Hrs.) [Mpa] U/T Min. 43 & Max.58 IS: 4031 P-6: 1988

Remarks:
1. Environmental Condition: Temperature: - 27±20C; Humidity: - Not less than 65%
2. The results listed refer only to the tested sample(s) and parameter(s). Authorized Signatory
3. This report is not to be reproduced wholly or in part and cannot be used as evidence in the Court of law P.K. SANCHETI
and should not be used in any advertising media without our special permission in writing. ( TM / QM )
4.** Not in NABL Scope (Chemical & Mechanical Section)
5. ULR- Unique Lab Report.
6.Humidity for Fineness 65% Max
Documnet No.-TR/23A Amendment No.- 09 Date of Issue-01.04.2013 Page No.- 1 of 1
END of Report