Professional Documents
Culture Documents
Technical features
Medium: Maintenance free life time: Temperature: Materials:
Compressed air, 40 μm filtered, Typically exceeds 25 Million cycles Ambient: Housing and covers: Aluminium
non-lubricated Operating pressure: +10 ... +50°C (+50 ... +122°F) anodised
Pre-lubrication of the static 3 ... 40 bar (43 ... 580 psi) Media: Valve piston: FDA compliant
sealing: Port size: 0 ... +50°C (+32 ... +122°F) max. synthetic material
USDA H1 compliant G1/4 ... G1 1/4 Air supply must be dry enough to O-ring: NBR
(registered NSF class H1) Mounting: avoid ice formation at temperatures
Operation: Line mounted below +2°C (+35°F)
Check Valve (no spring)
Technical data
Symbol Port size Nominal Ø Kv Weight Model
(mm) (m3/h) (kg)
G1⁄4 8 1,2 0,04 VSP152226
G3⁄8 10 1,9 0,07 VSP152227
G1⁄2 13 3,2 0,17 VSP152035
1 2
G3/4 19 6,7 0,29 VSP152036
G1 25 10,0 0,64 VSP152037
G1 1/4 31 18,0 0,78 VSP152038
Our policy is one of continued research and development. We therefore reserve the right to amend, 5/15
without notice, the specifications given in this document. (2013 - 5236b) © 2015 Norgren Switzerland en 5.10.363.01
VSP152...
SBM technology, 40 bar check valve
Dimensions Dimensions in mm
Projection/First angle
1 2
B
B
D
G1/2 ... G1 1/4
C
1 2
B
Warning
These products are intended for use in industrial compressed air The system designer is warned to consider the failure modes of all
systems only. Do not use these products where pressures and component parts used in fluid power systems and to provide adequate
temperatures can exceed those listed under safeguards to prevent personal injury or damage to equipment in the
»Technical features/data«. event of such failure.
Before using these products with fluids other than those specified, System designers must provide a warning to end users in the system
for non-industrial applications, life-support systems or other instructional manual if protection against a failure mode cannot be
applications not within published specifications, consult IMI NORGREN. adequately provided.
System designers and end users are cautioned to review specific
Through misuse, age, or malfunction, components used in fluid warnings found in instruction sheets packed and shipped with these
power systems can fail in various modes. products.
Our policy is one of continued research and development. We therefore reserve the right to amend,
en 5.10.363.02 without notice, the specifications given in this document. (2013 - 5236b) © 2015 Norgren Switzerland 5/15