You are on page 1of 2

VP40, 2/2 - Proportional flow control valve

Direct actuated poppet valve (stainless steel)

>> Port size: G1/4 (ND 4) >> Short switching time


>> Low hysteresis >> Compact design
>> Good repeatability >> Conforms with RoHS
>> High flow rate
>> High sensitivity
response

Technical features
Medium: Pressure setting p2: Repeatability *1): Materials:
Compressed air, filtered (40µm), 1 ... 16 bar (14 ... 232 psi) <1% (p2 max) Body: stainless steel
lubricated or non-lubricated, water Port size: Degree of protection: Seals: FPM
Operation: G1/4 IP65 with connector
Proportional solenoid Voltage: Ambient/Media temperature: Drive electronics:
Flow direction: 12 V d.c. -10 ... +40°C (+14 ... +104°F) pQ05 See datasheet 7.5.100
Fixed Nominal power (PN): Air supply must be dry enough to pQ11 See datasheet 7.5.115
Mounting: 22 W avoid ice formation at temperatures pQ12 See datasheet 7.5.120
Any, but preferably with Resistance (R20): below +2°C (+35°F)
solenoid vertical 6,5 Ω
Operating pressure p1: Duty cycle: *1) Values at 20°C (+28°F) with
20 bar ( 290 psi) max. 100 % dither 15% at 40 Hz
Hysteresis *1):
<3% (at max. p2)

Technical data, standard model


Symbol Offrice Port Pressure setting p2 Operating pressure p1 Rated current * Weight Model
(mm) size (bar) max. (bar) In (mA) (kg)
4 G 1/4 1 ... 16 20 1800 1,35 4088126707901200

1 2

* These are typical values depending on ambient temperature and valve tolerances.

Accessory
Connector
DIN EN 175301-803, form A

Model
0570275

Our policy is one of continued research and development. We therefore reserve the right to amend, 3/15
without notice, the specifications given in this document. (2014 - 6004b) © 2014 Norgren GmbH en 6.6.02401
VP40, 2/2 - Proportional flow control valve
Direct actuated poppet valve (stainless steel)

Characteristic flow curves at p1 20 bar *,


Medium: Compressed air

p2 (bar)

p2 = f (I)
18

16

14

12

10

0 160 320 480 640 800 960 1120 1280 1440


Q (l/min)

* The values are serve for the basic Furthermore a deviation of the values
illustration and could be different to during the operating time should be
the end product due to the device expected. This characteristic can be
tolerances. avoided by a regulated configuration.

Dimensions Dimensions in mm
Projection/First angle

L 12
45 57 Pg 11
36,5

133,5

135
G1/8

6,5

3
64,5
G1/4

1
52,5

38
25

2
50 G1/4
34
50

Warning
These products are intended for use in industrial compressed air The system designer is warned to consider the failure modes of all
systems only. Do not use these products where pressures and component parts used in fluid power systems and to provide adequate
temperatures can exceed those listed under safeguards to prevent personal injury or damage to equipment in the
»Technical features/data«. event of such failure.
Before using these products with fluids other than those specified, System designers must provide a warning to end users in the system
for non-industrial applications, life-support systems or other instructional manual if protection against a failure mode cannot be
applications not within published specifications, consult IMI NORGREN. adequately provided.
System designers and end users are cautioned to review specific
Through misuse, age, or malfunction, components used in fluid warnings found in instruction sheets packed and shipped with these
power systems can fail in various modes. products.

Our policy is one of continued research and development. We therefore reserve the right to amend, 
en 6.6.02402 without notice, the specifications given in this document. (2014 - 6004b) © 2014 Norgren GmbH 3/15