You are on page 1of 9

9 Nov 2018 10:23:34 - 1-np.

sm

Stanje 1
p1 8 MPa 80 bar t1 400 °C

Tabela 4.4.8. strana 88

kJ kJ
h1 3140.1 s1 6.367
kg kg K

Stanje 2
p2 0.4 MPa 4 bar x2 0.96

Tabela 4.4.7. strana 59


kJ kJ
h2' 604.7 h2'' 2738.5
kg kg

kJ
h2 h2' x2 h2'' h2' 2653.15
kg

Stanje 3
t3 280 °C p3 p2 400 kPa

Tabela 4.4.8. strana 68


kJ kJ
h3 3025.7 s3 7.4939
kg kg K

1/2
9 Nov 2018 10:23:34 - 1-np.sm

Stepen dobrote za turbinu visokog pritiska


Tabela 4.4.7. strana 59
kJ kJ kJ
s2i s1 6.367 s2' 1.7764 s2'' 6.8966
kg K kg K kg K

s2i s2'
x2i 0.89657
s2'' s2'

kJ
h2i h2' x2i h2'' h2' 2517.79
kg

h1 h2
ηd 0.7825
h1 h2i

Stanje 4
p4 4 kPa 0.004 MPa

Tabela 4.4.7. strana 59


kJ kJ kJ kJ
s4' 0.4224 s4'' 8.4747 h4' 121.41 h4'' 2554.1
kg K kg K kg kg

s4i s3

s4i s4'
x4i 0.8782
s4'' s4'

kJ
h4i h4' x4i h4'' h4' 2257.79
kg

kJ
h4 h3 ηd h3 h4i 2424.81
kg

h5 h4'

kJ
h6 h5 121.41
kg

h4 h5
ηt 1 0.3208
h1 h6 h3 h2

2/2
9 Nov 2018 10:23:51 - 2-np.sm

pmax 80 bar pmin 0.2 bar kg t1 540 °C


mp 282
s
po 10 bar

Stanje 1

t1 540 °C p1 pmax 80 bar

Prirucnik za TD, strana 89 Tabela 4.4.8.

kJ kJ
h1 3496.2 s1 6.8486
kg kg K

1/2
9 Nov 2018 10:23:51 - 2-np.sm

Stanje o

kJ po
so s1 6.8486 1 MPa
kg K

Prirucnik za TD, strana 71 Tabela 4.4.8. linearna interpolacija

2920.5 2897.9 kJ kJ
ho 2897.9 6.8486 6.8382 2903.19
6.8826 6.8382 kg kg

Stanje 2

kJ p2 pmin 0.02 MPa


s2 so 6.8486
kg K
Na osnovu podataka za entropiju v.p na liniji zas iz PTD, strana 58 Tabela 4.4.7.

6.8486 0.8321
x2 0.85014
7.9092 0.8321
kJ kJ
Prirucnik za TD, strana 58 Tabela 4.4.7. h2' 251.46 h2'' 2609.6
kg kg
kJ
h2 h2' x2 h2'' h2' 2256.2
kg
Stanje 3
h3 h2'

Stanje 4

-rad NP se zanemaruje
h4 h3

Stanje 5

Prirucnik za TD, strana 59Tabela 4.4.7.

kJ
h5 762.6
kg
Bilans mesnog zagrejaca

mo ho mp mo h4 mp h5

h5 h4 kg
mo mp 54.36
ho h4 s

Pturbine mp h1 ho mp mo ho h2 314.5 MW

mp mo h2 h3
ηc 1 0.40799
mp h1 h5

2/2
9 Nov 2018 10:24:04 - 3-np.sm

Stanje 1
6
p1 2.5 MPa 2.5 10 Pa t1 733 K 459.85 °C

PTD strana 79 Tabela 4.4.8.

vrednosti uzete za temperaturu od 460°C


kJ kJ
h1 3373.2 s 7.2062
kg 1 kg K

ηdtvp 0.9 kg
mp 12.5 PT 11 MW
s

1/2
9 Nov 2018 10:24:04 - 3-np.sm

Stanje o
po 0.3 MPa 300 kPa

kJ
soi s1 7.2062
kg K

Tabela 4.4.8 strana 67-lin. inter.

2824.3 2803.4 kJ kJ
hoi 2803.4 7.2062 7.1767 2816.7
7.2232 7.1767 kg kg

kJ
ho h1 ηdtvp h1 hoi 2872.3
kg

Stanje 3
p2 4 kPa 0.04 bar

p3 p2 0.004 MPa

Tabela 4.4.7. strana 58

kJ
h3 121.41
kg
rad napojne pumpe se zanemaruje

h4 h3

Stanje 5
p5 po 0.3 MPa

Tabela 4.4.7. strana 59

kJ
h5 561.4
kg

rad napojne pumpe se zanemaruje

h6 h5

h5 h4 kg
mo mp 1.9993 iz bilansa MZ
ho h4 s

PT mp h1 ho
kJ
h2 ho 2421
mp mo kg iz bilansa turbine

Qkd mp mo h2 h3 24.1475 MW

Qkd
ηt 1 0.313
mp h1 h5

2/2
9 Nov 2018 10:24:22 - 4-np.sm

1/3
9 Nov 2018 10:24:22 - 4-np.sm

Stanje 1
6 t1 460 °C
p1 6 MPa 6 10 Pa

PTD Tabela 4.4.8. strana 86


kJ kJ
h1 3326.8 s 6.7546
kg 1 kg K

Stanje o
po 0.3 MPa

kJ
so s1 6.7546
kg K

Na osnovu podataka iz tabele 4.4.7. na strani 59

6.7546 1.6717
xo 0.9552
6.9930 1.6717

kJ kJ
ho 561.4 xo 2725.5 561.4 2628.5
kg kg

Stanje 2

p2 40 kPa 0.4 bar

kJ
s2 s1 6.7546
kg K
Na osnovu podataka iz tabele 4.4.7. na strani 58

6.7546 1.0261
x2 0.8621
7.6711 1.0261
kJ kJ
h2 317.65 x2 2636.8 317.65 2316.9
kg kg

Stanje 3

Na osnovu podataka iz tabele 4.4.7. na strani 58


p3 p2 0.04 MPa

kJ
h3 317.65 kljucala tecnost!
kg

Stanje 4
h4 h3 zanemaruje se rad napojne pumpe

2/3
9 Nov 2018 10:24:22 - 4-np.sm

Stanje 5

po 0.3 MPa

tsat 133.54 °C
Tabela 4.4.7. strana 59

t5 133.54 13.54 °C 120 °C

t5 120 °C
p5 p1 6 MPa

Na osnovu tabele 4.4.8. na strani 84

kJ
h5 507.8
kg

Stanje kondenzata na izlazu iz povrsinskog razmenjivaca toplote


Tabela 4.4.7. strana 59
pkond po 0.3 MPa

kJ
hkond 561.4 kljucala tecnost!
kg

kg
mp 10
s
h5 h4 kg
mo mp 0.9199 iz bilansa Povr.zag.
ho hkond s

PT mp h1 ho mp mo ho h2 9812.01 kW

3/3

You might also like