REPLACEMENT PROCEDURE OF MAGNETRON FOR 2 UNIT X-RADAR Page 1

Turn the power off.

1.Location : Inside of Antenna Scanner on the fore


mast.

2. Switch off ANT MOTOR SW.

3. Remove 4 Pcs of Hexagonal Head Bolt from the


Stern side.
Open the cover, take care of the packing.

4. Disconnect the cable which is


connected to Performance Monitor.

5. Disconnect the high voltage (500V) cord.


Page 2

6.Disconnect the cable of PWR Power Circuit Board.

7. Disconnect the cable of Fan Motor.

8. Disconnect the Coaxial cable connector.

9. Disconnect the cable from terminal board.

10. Disconnect the Ground terminal.


Page 3

11.Remove 2 pcs of bolt, affixed from the transceiver


unit.

12.Remove 2 pcs of bolt, affixed from the


transceiver unit.

13. Take out Transceiver Unit.

14. Carry the trasceiver unit in a safe place


such as wheelhouse.

15. Disconnect the cable of Fan Motor.


Page 4

16. Turn over the Transceiver Unit.


Remove total 6 Pcs of screw.
Remove Protection Cover.

17. Record the position of color cable of


magnetron connecting to Pulse
Transformer.

18. Disconnect the cable of Magnetron


with Soldering iron.

19. Remove 4 Pcs of screw. Replace the


Magnetron.
Connect the cable of Magnetron by
Soldering iron.
Page 5

20. To put back reverse the sequence, and the unit


is assembled. Carry it to the fore mast.
Insert and fixed Transceiver Unit by 2 Pcs of bolt.

21. Connect Ground and High Voltage cord.

22. Connect the cable of Fan Motor and PWR Power


citcuit board

23. Connect the Coaxial Cable and cable


of Terminal Board.

24. Take care of the rubber packing.


Page 6

25. Confirm the rubber packing is correctly in the


ditch.
Close the cover and fixed with 4 Pcs of bolts.

26. ANT MOTOR SW On. Close Cap.

A. Turn the power on.


B. Wait for about 30 minutes in the ST-BY state.
C. ST-BY and TX are repeated five times or more, in the short range (0.5mile).
D. Wait for about 30 minutes in the send state.
E. Execute tune initialize in “[Menu] -> 1 -> 3:TUNE INITIALIZE”.
F. Reset each preset time to “0” in “[Menu]->0->4->8:ON TIME, 9:TX TIME”.

TUNE INITIALIZE

27. Performance Check. In "[Menu]->


Echo->PM->ON".
Check Performance Circle.
PM Check finish in "[Menu]->Echo->
PM->OFF".
Page 7
Page 1

REPLACEMENT PROCEDURE OF MAGNETRON FOR 3 UNIT X-RADAR

Turn the power of f.

1.Remove the Cover of the Transceiver Unit.

2. Disconnect the cable from terminal board.

3.Remove the Information Cover.


Page 2

4.Disconnect the cable of PWR Power Circuit Board.

5. Disconnect the Coaxial cable connector.

6. Disconnect the cable from the PCB.

7. Remove 2 pcs of bolt affixed


from the transceiver unit.
Page 3

8. Disconnect high voltage (500V) cord.

9. Disconnect cable of Fan Motor.

10. Record the position of color cable of


magnetron connecting to Pulse Transformer.

11. Disconnect cable of Magnetron with


Soldering iron.
Page 4

12. Remove 4 Pcs of screw. Replace the Magnetron.

Connect the cable of Magnetron by Soldering iron.

13. Connect the cable of Fan Motor.

14. To put back the transceiver unit


reverse the sequence.

15, Recover the Transceiver Unit


CAUTION : Gap of Wave Guide connectioin, less
than 1mm.

A. Turn the power on.


B. Wait for about 30 minutes in the ST-BY state.
Page 5

C. ST-BY and TX are repeated five times or more, in the short range (0.5mile).
D. Wait for about 30 minutes in the send state.
E. Execute tune initialize in “[Menu] -> 1 -> 3:TUNE INITIALIZE”.
F. Reset each preset time to “0” in “[Menu]->0->4->8:ON TIME, 9:TX TIME”.

TUNE INITIALIZE

6. Performance Check. In "[Menu]->


Echo->PM->ON".
Check Performance Circle.
PM Check finish in "[Menu]->Echo->
PM->OFF".