You are on page 1of 2
1116/22, 605 PM Hybrid Controls (ALL agnostic Trouble Cades ( DTC )- ALLDATA Repair 2007 Saturn Truck VUE FWD L4-2.4L Hybrid Vehicle > ALL Diagnostic Trouble Codes ( DTC) > Testing and Inspection > P Code Charts > P1AB1 HYBRID CONTROLS DTC P1AB1 \gnostic Instructions. * Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. See: Vehicle > Initial Inspection and Diagnostic Overview * Review Strategy Based Diagnosis for an overview of the diagnostic approach * Diagnostic Procedure Instructions provides an overview of each diagnostic category. DTC Descriptor DTC PIABI - Starter/Generator Phase U-V-W Current Sensor Overcurrent Cir uuit/System Description The starter/generator control module (SGCM) monitors the phase U/V/W current sensor to detect 3 phase overcurrent and to protect the MOSFET. Conditions for Running the DTC * Engine running. * Wake up signal is ON. Conditions for Setting the DTC Over current signal set for 20 ms. ‘Action Taken When the DTC Sets * Stop PWM (MGU shutdown) * APM PWM OFF * Battery disconnection (disconnect SW on/off) Conditions for Clearing the DTC Over current signal not valid. Diagnostic Aids * Possible MGU winding short to other winding or short to case. * Possible FET breakdown or gate driver circuit fault hitps://my alldata.com/repai/#/repar/anticle/43840/component/3926/typel423/nonstandard/'1279730/selfRetLineale we 1116022, 6:05 PM Hybrid Controls (ALL Diagnostic Trouble Codes ( DTC) - ALLDATA Repair Circuit/System Testing Caution: To help avoid personal injury, additional precautions must be taken prior to working on the generator control module or the generator starter. After removing the 36V battery cables from the generator battery, remove both engine wiring harness connectors from the generator control module. Wait at least 5 minutes and then remove the generator control module cover. Verify voltage levels at all 36V, 12V, and 3-phase connections, are less than 3 volts using a DMM before proceeding. 1. Disconnect the 3-phase cables from the SGCM. 2. Test each of the 3:phase cables for a short to ground, * [fall circuits test normal, replace the SGCM, 3. Disconnect the 3-phase cables from the MGU. 4, Test each of the 3-phase cables individually for a short to ground. + Ifall circuits test normal, replace the MGU + Ifany circuit does not test normal, replace the 3-phase cable assembly. Repair Instructions Perform the Diagnostic Repair Verification after completing the diagnostic procedure. See: AL L Diagnostic Trouble Codes (DTC) > Verification Tests Control Module References for SGCM replacement, setup, and programming Generator Control Module 3-Phase Cable Assembly Replacement. Generator with Starter Replacement hetps://my.alldata.com/repai/#/repar/anicle/43840/component/3926/itypel423/nonstandard/1279730/selfRetLinealse 22

You might also like