You are on page 1of 4

BOSMAL/P-7-01/22 (F6e)

TEST REPORT Page: Pages:

Number: BOS/4047/BM/22 2 4

1. DESCRIPTION AND IDENTIFICATION OF TESTED PART

MUT 1.5 (3248025); fig. 1


Quantity: 1 pc.
Delivery date: 04.07.2022

c
Fig. 1 a…c View of Sample before the Test
BOSMAL/P-7-01/22 (F6e)

TEST REPORT Page: Pages:

Number: BOS/4047/BM/22 3 4

2. RANGE OF THE TEST


Corrosion Test according to DIN 50018:2013-05

3. TEST DESCRIPTION
The Test was performed in corrosion chamber (fig. 2).
Test description:
- 1 cycle:
- application of 0.67% SO2 into the chamber: DIN 50018:2013-05 – AHT 1.0 S
- humidity phase: 40±3oC / ~100 % CH / 8 h,
- ambient phase: 18 to 28oC / max. 75 RH / 16 h,
- chamber volume: 400 L
- duration: 2 cycles

Fig. 2 View of Sample in Corrosion chamber

Testing and measuring equipment

Name Number Accuracy Calibration date Next calibration


Corrosion chamber VLM 400L X/2170/BMT ± 0.5oC 12.2021 12.2022
Thermo-hygrometer L/1324/BMT ± 2% 09.2021 09.2023

4. TEST RESULTS
Views of samples are presented in fig. 3.

We have noticed the base material oxidation on copper wire as a layer


BOSMAL/P-7-01/22 (F6e)

TEST REPORT Page: Pages:

Number: BOS/4047/BM/22 4 4

c
Fig. 3 a…c View of Sample after the Test

End of „Test Report”