Introduction
• Soft Keys
• Menu

CONNECT W ITH THE BEST


Soft Keys

DN: firmware upgrade and log data download (USB


flash driver)
OK Key MENU BACK Power
PC: operating via PC (USB serial
cable)

Management Port LED Arrow Number


Display Keys Keys
FUNCTION

© 2014 Intellian Proprietary 4 Connect with the best


Menu

Touch Key Function

OK Key Enter next step, or menu

MENU Enter SETUP mode

• In SETUP mode, returns to previous menu or option, or saves the


adjusted settings.
BACK
• In NORMAL mode, returns to the first page of antenna current
status.
Moves cursor to an alternative option to select, or increase and
Arrow keys
decrease the selected character to a desired value.

FUNCTION Saves the adjusted settings.

Numbers keys Inputs numbers.

© 2014 Intellian Proprietary 5 Connect with the best


Normal Mode
• System Initialization
• Monitoring Current Antenna Status

CONNECT W ITH THE BEST


System Initialization I
1. The data communication is being established between the antenna and the ACU.

2. The ACU receives antenna information.


Antenna is
uploading the data
from ACU.
3. The elevation angle is initialized.

Elevation 45°
=>
Sensor box 0°
4. The azimuth angle is initialized.

Go to home sensor

5. The antenna returns to the target satellite position.

© 2014 Intellian Proprietary 7 Connect with the best


System Initialization II

6. The antenna is searching for the target satellite.

7. The antenna has locked onto the satellite.

© 2014 Intellian Proprietary 8 Connect with the best


8
Monitoring Current Antenna Status
Current Tracking Status

Current IF signal level is displayed.


SIG when tracking DVB carrier ;
AGC when tracking NBD (SCPC) carrier.
If the signal is strong enough to be locked on, it shows  .
VL refers to Vertical Low.
Local frequency is decided by the
Name of tracked satellite supplied voltage from the LNB:
• VL: 13V + 0 KHz, HL: 18 V + 0 KHz,
• VH: 13V + 22 KHz, HH: 18 V + 22 KHz

Elevation Angle LNB Skew Angle


True azimuth degree:
(Relative azimuth degree + ship’s heading)

© 2014 Intellian Proprietary 9 Connect with the best


Monitoring Current Antenna Status
Save Current Satellite Information

Az (True Azimuth): ---.- will be displayed at ACU when,


• GYRO TYPE is set to NONE.
• GYRO TYPE is set to NMEA without receiving a proper input
signal.

Touch FUNCTION key to save current satellite (BOW OFFSET) information


or abort/ return to the main display.

© 2014 Intellian Proprietary 10 Connect with the best


Monitoring Current Antenna Status
Current Tracking Status, Tracking and Heading Information

Touch right arrow key to display NBD, GPS and Ship’s Heading Information.

 NBD IF tracking frequency: 1247000 KHz.


 Detected band width: 1000 KHz
 SIG: 301 (when NBD mode for tracking signal is chosen).
 W (West)/ E (East) longitude: 4.53 East
 N (North)/ S (South) latitude: 52.22 North
 HDG (ship’s heading): 90
 LNB local: 1000 MHz

© 2014 Intellian Proprietary 11 Connect with the best


Monitoring Current Antenna Status
Antenna and ACU’s Voltage and Version

Touch right arrow key to display:


 Antenna part number, antenna serial number, PCU and stabilizer firmware version
 ACU part number, ACU serial number, ACU firmware version and library version.

Touch BACK key to return to the first page of the antenna current status.

© 2014 Intellian Proprietary 12 Connect with the best


Monitoring Current Antenna Status
USB Flash Driver Function

Touch right arrow key to display the USB FUNCTION. This menu will be
displayed automatically if USB flash driver is plugged into the USB port in
the front panel of the ACU.
 UPGRADE FIRMWARE and COPY LOG DATA.

Touch OK key to select a menu.

© 2014 Intellian Proprietary 13 Connect with the best


Monitoring Current Antenna Status
Error Message of the USB Flash Driver Function
 UPGRADE FIRMWARE
 FIRMWARE FILE NOT FOUND
 INVALID FIRMWARE
 MORE THAN 1 FILE EXIST
 CHECK USB CONNECTION

 COPY LOG DATA:


 COPY LOG DATA TO USB [30%]
 NOT ENOUGH SPACE IN USB
 CHECK USB CONNECTION

© 2014 Intellian Proprietary 14 Connect with the best


Monitoring Current Antenna Status
Real-time Diagnostic and Erase Error Messages

Touch right arrow key to display the real-time diagnostic result.

The real-time diagnostic code will be displayed automatically only if


there is any error found during the system operation.

Touch FUNCTION key to erase diagnostic error message.

© 2014 Intellian Proprietary 15 Connect with the best


Menu Tree – Installation & System
Depth 0 Depth 1 Depth 2 Depth 3 Depth 4 Depth 5
INFO. ANTENNA SET LOCAL LOCAL 13+0
DISPLAY
LOCAL 18+0

SATELLITE LOCAL
13+22
LOCAL
SETUP 18+22
SET
LOCATION GYRO TYPE

BAUDRATE

LATITUDE
SYSTEM
LONGITUDE

HEADING - NONE / NMEA / NMEA2000 / GROUND TEST


USE
MEDIATOR - NO / MEDIATOR-ANT / MEDIATOR-MODEM/ MEDIAOTR-ALL
MODEM PORT MODEM TYPE - IDREICT-IO/IDIRECT-AMIP/COMTECH-IO/COMTECH-ROSS/HUGHES/SATLINK/ELEKTRIKOM/
GILAT-SE-II/USER
MEDEM PORT - ETHERNET / RS 232 / RS 422
PROTOCOL - I/O CONSOLE / OPEN AMIP / SERIAL GPS/ ROSS/ VACP/ ELEKTRIKOM-AMIP/ GILAT-SE-II
GPS OUT
SENTENCE - GPGLL / GPGGA / SIMPLE GPGGA
USE TX MUTE

USE EXT.
LOCK
BACKUP USER DATA
EXT. LOCK
ACTIVE RESTORE USER DATA
TX MUTE DEFAULT ACU-REMOTE
MANAGEMNET ACTIVE UPGRADE FROM USB
TYPE COPY LOG TO USB
BACKUP TO USB
KEY LOCK YES/NO RESTORE FROM USB
UPGRADE ACU-REMOTE
PASSWD
GYRO BOW
INSTALLATION SATELLITE LATITUDE LONGITUDE
TYPE OFFSET
LOCAL LOCAL LOCAL LOCAL MODEM
18+22 13+22 18+0 13+0 TYPE

© 2014 Intellian Proprietary 16 Connect with the best


Menu Tree – Satellite
Depth 0 Depth 1 Depth 2 Depth 3 Depth 4 Depth 5

INFO. ANTENNA …
DISPLAY

LOAD SAT. LOAD SAT.


SETUP

SELECT
EDIT SAT. LONGITUDE.
SAT.
SATELLITE
EDIT NAME

DVB
VERIFY
SKEW
OFFSET
SELECT
LOCAL
ADD SAT. TRACK
SIGNAL
RX POL
TX POL.
DVB FREQ.

SYMBOL
CHECK NID
NID

NBD FREQ

SYSTEM … BANDWIDTH

INSTALLATION …

© 2014 Intellian Proprietary 17 Connect with the best


Menu Tree – Antenna
Depth 0 Depth 1 Depth 2 Depth 3 Depth 4 Depth 5
INFO. ANTENNA MANUAL STEP SIZE
DISPLAY SEARCH
AZIMUTH
ELEVATION CALIBRATION

AGC MANUAL
SET ANGLE ADJUST
SETUP POL ANGLE MENU RESET
WAIT TIME MECHANICAL
INCR. OFFSET
SEARCH
STEP
SATELLITE PARAM AZ. RANGE
SEARCH 1
SEARCH 2 EL. RANGE
SEARCH 3
DETECT
LEVEL
SYSTEM SET
TRACKING
PARAMETER
LEVEL
INSTALLATION DETECT
LEVEL NBD
SAVE
TRACKING
LEVEL NBD IDLE
BOW
OFFSET REBOOT
EL. ADJUST

OPERATION

BLOCK ZONE ACTIVE

AZ START

AZ END

EL LIMIT

DIAGNOSTIC TEST ITEM

18 RESULT
© 2014 Intellian Proprietary 18 Connect with the best
Setup Mode
• Entering Setup Mode

CONNECT W ITH THE BEST


Entering Setup Mode

 While the antenna is in SEARCHING/ TRACKING mode, touch MENU


key to enter SETUP mode.
 The * (asterisk) indicates key pad lock function is on.

 Enter the password (1590) to enter into the SETUP mode.


 If the key pad lock function is off, access to the SETUP mode directly.

© 2014 Intellian Proprietary 20 Connect with the best


Installation Settings
• Initial Setup for Satellite
• Initial Setup for Bow Offset and Gyro
• Initial Setup for Modem Interface

CONNECT W ITH THE BEST


Initial Setup for Satellite

Select INSTALLATION.

Choose the satellite.

Enter current latitude (N/ S)


and longitude (E/ W) unless
GPS operates.

© 2014 Intellian Proprietary 22 Connect with the best


Initial Setup for Bow Offset and Gyro

GYRO Type:
• None
• NMEA
• NMEA2000
• Ground Test

Setting of Heading Device

Existence of Heading Data No Device NMEA/ NMEA2000 Ground Test

With Heading Data Search 1 Search 3 Search 3

Without Heading Data Search 1 Search 1 Search 3

 Search pattern 1 and 3 will be initiated in accordance with GYRO type and the existence of GYRO input.
 The BOW OFFSET is to offset the angle difference between the antenna’s bow and the ship’s bow.
(Range 0 to 360).

NOTE: The bow offset will not be saved automatically if Search 1 pattern is initiated. In this case,
the antenna will need to retarget the desired satellite using Search 1 every time the antenna restarts.

© 2014 Intellian Proprietary 23 Connect with the best


Initial Setup for Modem Interface I

Modem interface setting will be set automatically once the modem type is
selected. The options on the next page will be displayed and required to be set
if USER SETTING is selected.

Modem Type
 USER SETTING  HUGES
 IDIRECT-I/O  SATLINK-SERIAL
 IDIRECT-AMIP  SATLINK-VACP
 COMTECH-I/O  ELEKTRIKOM-AMIP
 COMTECH-ROSS

© 2014 Intellian Proprietary 24 Connect with the best


Initial Setup for Modem Interface II

Touch BACK key to load the current setting or abort and return to the main display.

 Setting is being loaded to the system.


 The ACU will restart the system automatically after uploading the setting.
 DO NOT TURN OFF ACU POWER while the data is being uploaded.

Antenna has locked onto the target satellite.

© 2014 Intellian Proprietary 25 Connect with the best


Antenna Settings
• Manual Search
• Set Pol. Angle
• Search Param
• Set Parameters
• Block Zone
• Diagnosis
• Diagnosis Code

CONNECT W ITH THE BEST


Manual Search

Select
ANTENNA

Select
MANUAL SEARCH

Adjust azimuth and elevation angles.


Press FUNCTION key to save the settings once
the maximum AGC/ SIG signal level is founded.

© 2014 Intellian Proprietary 27 Connect with the best


Manual Search
Save Current Satellite

 If the current settings are able to locate the satellite, touch FUNCTION key to save
current satellite information.
 This will help to reduce the satellite acquisition time after restarting the system.
 Touch left arrow key to move cursor to YES and touch the OK key to save the settings.

NOTE: If the GYRO type is not NMEA or the GYRO is not connected to the
ACU, the information cannot be saved.

© 2014 Intellian Proprietary 28 Connect with the best


Set Pol. Angle

 Touch up and down arrow keys to the SELECT LNB POL. ANGLE MENU and touch
OK key to run CALIBRATION or MANUAL ADJUST.
 If the control board, LNB pol potentiometer or belt is replaced, calibrate LNB POL ANGLE.
NOTE:
LNB POL ANGLE menu
will be displayed only
if MANUAL ADJUST is
selected.
Touch up and down arrow keys to increase or decrease the LNB POL ANGLE manually
and the correspondent SIGNAL level will be displayed next to it. Touch BACK key to
return to the main display.

© 2014 Intellian Proprietary 29 Connect with the best


Search Param
Define Search Range, Step, Wait Time

Define the time-out for automatic initiation of a search after the signal level drops below
the pre-defined threshold value. (Range: 1 second to 120 second)

This parameters should only be changed by an authorized service


technician. Improper setting of these parameters will cause your
system to perform improperly.

© 2014 Intellian Proprietary 30 Connect with the best


Search Param
Search 1

 Will be automatically initiated when the ship’s heading


input does not exist or is failed.
 The search cycle will repeat until the antenna receives
the lock signal from the modem or the DVB transponder
of the target satellite is decoded by the antenna.
 A search pattern 1 or 3 will be initiated according to
selected GYRO type and the existence of GYRO
input.ini.

© 2014 Intellian Proprietary 31 Connect with the best


Search Param
Search 1
 If the desired signal is found and is above the predefined
detect level, the ACU will enter to Search 3.

© 2014 Intellian Proprietary 32 Connect with the best


Search Param
Search 1

Search1
(GYRO Free)
Search Pattern
EL Position

AZ Direction

Search1
Antenna Motion
Target EL Angle Target EL Angle + 0.5 Target EL Angle - 0.5
Turn 1 Turn 2 Turn 3

© 2014 Intellian Proprietary 33 Connect with the best


Search Param
Search 3
Azimuth (AZ) Range

0.5

Elevation (EL) Range

Search3
Search Pattern

 Search 3 will automatically be initiated when AGC/ SIG falls below the current tracking level
threshold value.
 If the desired signal is found and above the predefined tracking level, the ACU will terminate
Search3 and go into TRACKING mode.

© 2014 Intellian Proprietary 34 Connect with the best


Set Parameters I

 Define signal detecting and tracking threshold level.


 Adjust BOW and elevation angle offset.
 Release motor brakes.
 Adjust tilt bias.

Enter password if KEY PAD LOCK is ON.


(Default password: 1590)
This parameters should only be changed by an authorized service technician.
Improper setting of these parameters will cause your system to perform improperly.

© 2014 Intellian Proprietary 35 Connect with the best


Set Parameters II

 DETECT DVB and TRACKING DVB should be defined when DVB was chosen for
TRACKING SIGNAL.
 DETECT NBD and TRACKING NBD should be defined when NBD (SCPC) was chosen
for TRACKING SIGNAL.

Peak Level

Tracking Level
TRACKING DVB/ NBD
Detect Level
DETECT DVB/ NBD
Noise Level

© 2014 Intellian Proprietary 36 Connect with the best


Set Parameters III

Offset the angle difference between the mechanical elevation angle and actual elevation angle.
(Range: 0 to 360 )

Offset the angle difference between the antenna’s bow and the ship’s bow.
(Range:  5)

© 2014 Intellian Proprietary 37 Connect with the best


Set Parameters IV

 SAVE: Save and execute current settings.


 IDLE ON/ OFF: Release motor brakes.
 RATE SENSOR BIAS: Calibrate rate sensors
 REBOOT: Reboot the system.
 TILT BIAS: Adjust tilt bias.

ADJUST TILT BIAS

Utilize LEVEL VIAL to adjust tilt bias.

© 2014 Intellian Proprietary 38 Connect with the best


Block Zone

 Up to 5 block zones are allowed to be programmed with relative azimuth


and elevation sectors.
 AZ. 1 START and AZ.1 END: This is clockwise of the tow points.
 AZ.1 START is where the relative azimuth starts and AZ.1 END is where the
relative azimuth ends.

© 2014 Intellian Proprietary 39 Connect with the best


Diagnosis

Choose from
two options
to execute
: FULL TEST
and SINGLE TEST.

© 2014 Intellian Proprietary 40 Connect with the best


Diagnosis Code
The data communication between the
CODE 101 CODE 109 The sensor box motor is tested.
antenna and the ACU is tested.

CODE 102 The azimuth motor is tested. CODE 110 The LNB is tested.

CODE 103 The elevation motor is tested. CODE 111 The LNB skew motor is tested.

CODE 104 The cross-level motor is tested. CODE 112 The Sub-Reflector is tested.

CODE 105 The azimuth encoder is tested. CODE 113 The antenna power is tested.

CODE 106 The cross-level encoder is tested. CODE 114 The ACU power is tested.

CODE 107 The GYRO sensor is tested. CODE 115 The receiver power is tested.

CODE 108 The tilt sensor is tested. CODE 116 The home sensor is tested.

Example of Test Result: ●2●●●●●●●●●−●●−

Test is skipped. (112 and 115 will only be applied to


● Test is passed. −
Intellian TVRO antenna systems.)
Refer to diagnosis code 102 as shown above for occurred
? Test is under process. 2
error explanation.

© 2014 Intellian Proprietary 41 Connect with the best


Satellite Settings
• Load Sat.
• Edit Sat.
• Add Sat.
• Check NID

CONNECT W ITH THE BEST


Load Sat.

 Select a desired satellite from the programmed library to


track.

Touch right arrow key to move cursor to SATELLITE and touch OK key.

Touch OK key to enter LOAD SAT menu.

 Touch up and down arrow keys to select the satellite you wish to track.
 Touch OK key to load the selected satellite.

© 2014 Intellian Proprietary 43 Connect with the best


Edit Sat. I

Touch right arrow key to move cursor to SATELLITE and touch OK key to enter it.

Touch right arrow key and OK key to enter EDIT SAT menu.

Touch up and down arrow keys to select the satellite that you wish to edit and
touch OK key to edit the selected satellite.

Edit satellite orbit position, LONGITUDE and satellite name.

© 2014 Intellian Proprietary 44 Connect with the best


Edit Sat. II

 Edit satellite DVB VERIFY(1) method and SKEW OFFSET.


 DVB VERIFY will be only activated and applied when DVB mode of TRACKING
SIGNAL is chosen.
 Touch up and down arrow keys to select DVB VERIFY and touch OK key to set
the parameter.

 DVB VERIFY(1)
 AGC− Use only Freq. for satellite tracking.
 DVB Lock− Use Freq./ Symbol for satellite tracking.
 DVB Decode− Use Freq./ Symbol/ NID for satellite tracking.
 DSS Decode− Use DSS Decode for satellite tracking.

© 2014 Intellian Proprietary 45 Connect with the best


Edit Sat. III

(1)

 Set SELECT LOCAL(1) frequency and TRACKING SIGNAL(2) .


 Touch left and right arrow keys until the desired character is selected.
 Touch up and down arrow keys to select the LNB local frequency from the
installed LNB. Or touch NUMBER keys to set the desired value directly.
 Touch OK key to set the parameter.

SELECT LOCAL(1) TRACKING SIGNAL(2)

The selectable LNB frequencies NBD


are depended on the installed DVB
LNB type.

© 2014 Intellian Proprietary 46 Connect with the best


Edit Sat. IV

 Set RX POL and TX POL which are the polarity of RX and TX.
 Touch up and down arrow keys to select VERTICAL or HORIZONTAL.
 Touch OK key to set the parameter.

 Set DVB FREQ., SYMBOL, and NID in accordance with the given satellite information.
 45,000 is the maximum symbol rate value.
 NID ranges from 0 x 0000 to 0 x FFFF (hexadecimal digit).

Set NBD IF FREQUENCY and BANDWIDTH when NBD mode of TRACKING SIGNAL.

© 2014 Intellian Proprietary 47 Connect with the best


Add Sat. I

Touch right arrow key to move cursor to SATELLITE and touch OK key to enter it.

Touch right arrow key and OK key to enter EDIT SAT menu.

Set satellite LONGITUDE and satellite name.

© 2014 Intellian Proprietary 48 Connect with the best


Add Sat. II

 Edit satellite DVB VERIFY(1) method and SKEW OFFSET.


 DVB VERIFY will be only activated and applied when DVB mode of TRACKING
SIGNAL is chosen.
 Touch up and down arrow keys to select DVB VERIFY and touch OK key to set
the parameter.

 DVB VERIFY(1)
 AGC− Use only Freq. for satellite tracking.
 DVB Lock− Use Freq./ Symbol for satellite tracking.
 DVB Decode− Use Freq./ Symbol/ NID for satellite tracking.
 DSS Decode− Use DSS Decode for satellite tracking.

© 2014 Intellian Proprietary 49 Connect with the best


Add Sat. III

 Set SELECT LOCAL(1) frequency and TRACKING SIGNAL(2) .


 Touch left and right arrow keys until the desired character is selected.
 Touch up and down arrow keys to select the LNB local frequency from the
installed LNB. Or touch NUMBER keys to set the desired value directly.
 Touch OK key to set the parameter.

SELECT LOCAL(1) TRACKING SIGNAL(2)

The selectable LNB frequencies NBD


are depended on the installed DVB
LNB type.

© 2014 Intellian Proprietary 50 Connect with the best


Add Sat. IV

 Set RX POL and TX POL which are the polarity of RX and TX.
 Touch up and down arrow keys to select VERTICAL or HORIZONTAL.
 Touch OK key to set the parameter.

 Set DVB FREQ., SYMBOL, and NID in accordance with the given satellite information.
 45,000 is the maximum symbol rate value.
 NID ranges from 0 x 0000 to 0 x FFFF (hexadecimal digit).

 Set NBD IF FREQUENCY and BANDWIDTH when NBD mode of TRACKING SIGNAL.

© 2014 Intellian Proprietary 51 Connect with the best


Check NID

 Verify NID (Network ID) of the current tracking frequency.

Touch DOWN arrow key and OK key to enter CHECK NID menu.

 CHECK NID is to verify the NID of the current tracking transponder.


 Touch OK key to verify the NID [0 x 0000] only when PRESS OK function is
activated.
 PRESS OK function will only be activated when DVB Lock signal is confirmed by
the antenna.
 However, NO LOCK message will be displayed if DVB Lock signal can’t be
confirmed.

© 2014 Intellian Proprietary 52 Connect with the best


System Setting
• Set Local
• Set Location
• Modem Port
• Management
• Key Lock

CONNECT W ITH THE BEST


Set Local I

 Set up the LNB local frequency for each corresponded


LNB voltage power.

Touch DOWN arrow key to move cursor to SYSTEM and touch OK key to enter it.

Touch OK key to enter SET LOCAL menu to set the LNB local frequency.

© 2014 Intellian Proprietary 54 Connect with the best


Set Local II

 Set LNB local oscillator frequency for each correspondent voltage power.
:13V +0 kHz, 18V +0 kHz, 13V +22 kHz, 18V +22 kHz
 Touch BACK key and touch left and right arrow keys to select the parameter
you wish to edit.
 Touch OK key to edit parameter. Or touch BACK key again to return to the
main display.
 LNB LOCAL: The selectable LNB frequencies are depended on the installed
LNB type.

© 2014 Intellian Proprietary 55 Connect with the best


Set Location I

Touch right arrow key to move cursor to SET LOCATION and touch OK key.

 A search pattern 1 or 3 will be initiated in accordance with the selected GYRO type
and the existence of the GYRO input.
 Choose from the options below depending on your device: 4800, 9600, 19200 and
38400
GYRO Type Baud Rate

No device 4800
NMEA 9600
NMEA2000 19200
Ground test 38400

© 2014 Intellian Proprietary 56 Connect with the best


Sat Location II
Current Position

Set the current LATITUDE and LONGITUDE.

 Entry of ship’s heading.


 Ensure that the supported Gyro Type is set correctly.
 If ship's gyrocompass output is other than NMEA(2000), a purchase of a GYRO
converter is required.

© 2014 Intellian Proprietary 57 Connect with the best


Modem Port I

Touch DOWN arrow keys to move cursor to MODEM PORT menu and touch OK key.

• Choosing USE MEDIATOR enables the use of Intellian Mediator if the antenna
is connected to the Intellian Mediator.
• It must be disabled if the Intellian Mediator is not connected to the ACU.
Improper setting of this parameter will cause your ACU’s modem interface
working incorrectly.

Modem Type
USER SETTING HUGHES
IDIRECT-I/O SATLINK-SERIAL
IDIRECT-AMIP SATLINK-VACP
COMTECH-I/O ELEKTRIKOM-AMIP
COMTECH-ROSS

© 2014 Intellian Proprietary 58 Connect with the best


Modem Port II

(1) (2)

• If MODEM TYPE is set to USER SETTING, MODEM PORT(1) of ACU must


be selected from the followings for a proper data communication with
modem: Ethernet, RS232/ 422, and Console.

© 2014 Intellian Proprietary 59 Connect with the best


Modem Port III
• PROTOCOL(2) is selected from the following table to interface with the modem.
PROTOCOL(2)

SERIAL GPS Sends GPS Out information from ACU (through RS232/ 422 port) to modem.

ROSS ROSS Open Antenna Management (ROAM). Comtech EF Data Cooperation developed.
Offers common management interface for Comtech EF Data's Roaming Oceanic Satellite
Server (ROSS) and ACU.
VCAP Interfaces between SatLink mobile VSAT IDU and the Intellian antenna controllers for
Intellian mobile antennas.
ElektrikomAMIP Is an OpenAMIP based protocol, and proceed the additional protocol.

Gilat SkyEdge II Is an NMEA0183 based protocol to monitor the status of the antenna and the modem. It
is passed through the Gilat SkyEdgeII modem RS232 serial port.
I/O CONSOL Interchanges information (GPS Out, TX mute, modem lock) between ACU (through
console port) and modem.
OpenAMIP ASCII based protocol. iDIRECT developed. Interchanges information between ACU and
modem. OpenAMIP is only intended to allow ACU and modem to perform synchronized
Automatic Beam Switching (ABS).

© 2014 Intellian Proprietary 60 Connect with the best


Modem Port IV

• Select the type of GPS OUT SENTENCE.


• Choose YES or NO to use the function of USE TX MUTE from the satellite
modem.
• A transmit inhibit output from the ACU will disable or mute the modem
transmit via a voltage whenever the antenna is blocked, searching, or is miss-
pointed 0.5 degrees from the peak satellite position.

GPS OUT SENTENCE

GPGLL
GPGGA
SIMPLE GPGGA

© 2014 Intellian Proprietary 61 Connect with the best


Modem Port

 USE EXT. LOCK is to select whether or not to use external lock signal coming from the
satellite modem. USE EXT. LOCK menu will only be activated when PROTOCOL is set as I/O
CONSOLE.
 EXT. LOCK ACTIVE is referred to identify modem which is locked on the correct satellite.
The modem lock output from the modem provides a logic input of 5 V (HIGH) or 0 V (LOW)
to ACU.
 EXT. LOCK ACTIVE menu will only be activated when PROTOCOL is set to I/O CONSOLE.

 TX MUTE ACTIVE is a transmit inhibit output coming from ACU to disable or mute the
modem transmit through 5 V (HIGH) or 0 V (LOW) whenever the antenna is blocked,
searching, or is miss-pointed 0.5º from peak satellite position.
 TX MUTE ACTIVE item will only be activated when PROTOCOL is set to I/O CONSOLE.

© 2014 Intellian Proprietary 62 Connect with the best


Management I

Touch arrow keys to move cursor to MANAGEMENT menu and touch OK key.

Choose proper process type from the table shown in the next slide.

© 2014 Intellian Proprietary 63 Connect with the best


Management II

SELECT PROCESS TYPE


BACKUP USER DATA Stores the current setting of antenna up to the ACU.
Restores the antenna status by using the backup data stored in the
RESTORE USER DATA
ACU.
DEFAULT ACU-
Returns ID and Password of the Web Server to a default values.
REMOTE P/W
UPGRADED FROM Upgrades the system by using firmware files from a specified folder in
USB the USB flash drive.
COPY LOG TO USB Copies the antenna log data from the system to the USB flash drive.
BACKUP TO USB Stores the antenna setting to a specified folder in the USB flash drive.
Restores the antenna by using the user data stored in a specified
RESTORE FROM USB
folder of USB flash drive.
UPGRADE ACU- Upgrades the system using the Remote Access firmware file (FWP)
REMOTE from a specified folder in the USB flash drive.

© 2014 Intellian Proprietary 64 Connect with the best


Key Lock

 Touch down arrow key to move cursor to SYSTEM menu and press OK key.

 Touch arrow key to move cursor to KEY LOCK menu and press OK key.

 Touch up and down arrow keys to define the usage of KEY PAD LOCK
menu when entering SETUP mode or saving the satellite information.
 Set up the password for entering the key pad lock.
 The factory default is 1590.

© 2014 Intellian Proprietary 65 Connect with the best