Download the BEA DECODER app Opening & safety sensor
for a quick overview for automatic sliding doors
of settings
(according to EN 16005 and DIN 18650,
including emergency exits)
DESCRIPTION
6
1
2
3 7
4 8
5 9
1. LCD 6. cover
2. radar antenna (narrow field) 7. main connector
3. radar antenna (wide field) 8. main adjustment knob
4. IR-curtain width adjustment 9. IR-curtain angle adjustment knob
5. IR-lenses
ACCESSORIES
BA: Bracket accessory CA: Ceiling accessory RA: Rain accessory CDA: Curved door accessory
Retrofit interface Door bell + interface Smart Daisy Chain hub 9 V battery
HOW TO USE THE LCD?
DISPLAY DURING NORMAL FUNCTIONING
Opening Safety Negative display = active output To adjust contrast, push and turn
impulse the grey button simultaneously.
During normal function only.
NAVIGATING IN MENUS
CHANGING A VALUE
6 6
ZIP code ZIP code ZIP code ZIP code ZIP code
ZIP code
E24 1 56 KG4 E24 1 56-KG4 E24 1 56-KG4 H24 1 56-KG4 H24 1 56-KG4
ID # 01 0 800 02F 01 0 800/02F 01 0 800/02F 01 0 800/02F 01 0 800/02F
ZIP code ZIP code Validate the last digit in order to activate the new ZIP code:
... H24 1 56-KG4 - v = valid ZIP code, values will be changed accordingly
V - x = invalid ZIP code, no values will be changed
01 0 800/02D
- v/x = valid ZIP code, but from a different product.
Only available values will be changed.
ENGLISH
GREEN
12-24 V
AC-DC BROWN POWER SUPPLY
* YELLOW
WHITE OPENING INPUT
PINK
*
SENSOR
GREY SAFETY INPUT
** RED
max . 5 cm TEST
BLUE OUTPUT
YE/BK +
*** OPENING INPUT
WH/BK - FOR CURRENT
SOURCE
FREQUENCY OUTPUT
for emergency exits
immunity: 2 immunity: 2
2.2 m 2.2 m
field size: 9
WIDTH
field size: 9
immunity: 2 immunity: 2
2.2 m 2.2 m
CLOSER
max.
9 cm**
OR AWAY
Additional
adjustments
are possible by
LCD or remote
control
(see p. 5)
Part of the detection field can be masked to reduce it. Always verify the actual detection field width
The arrow position determines the width of the detection field. with a piece of paper and not the Spotfinder,
which detects the whole emitted field.
3.50
3,50 m
m 3,50 m
3.50 The size of the detection field varies according to the
Mounting Detection DIN 18650 EN 16005
mounting height and the settings of the sensor.
height width BS 7036 33 m
m 3m The full door width must be covered.
2.00 m 2.00 m 2.50
2,50 m
m 2,50 m
2.50
2.20 m 2.20 m 22 m
m 2m
2.50 m 2.50 m
3.00 m d max
3.50 m d max
dd max
max == 2.5
2,5 m
m d max = 3 m
5 SETTINGS OR
Choose one of the following presettings or adjust the sensor manually (see p.5):
SETUP 1 (QUICK)
reference picture
+ 2s
SETUP 2 (ASSISTED)
test of full door cycle + + + 4s
reference picture
TEST THE GOOD FUNCTIONING OF THE INSTALLATION BEFORE LEAVING THE PREMISES!
4
OVERVIEW OF SETTINGS
0 1 2 3 4 5 6 7 8 9
Back
More
factory values for radar immunity, IR immunity, IR number and redirection
shopping
PRESETTINGS standard critical street increased immunities, 1 curtain
env. increased immunities, redirection = motion and presence
RAD: FIELDSIZE small > > > > > > > large
BASIC
More
Back
excludes conformity of the door system according to EN
16005 / DIN 18650 / BS 7036. IR Immunity on values 4 or 5 is
factory value incompatible with IR presence time on value 0
not allowed when the sensor is used in emergency exits
Back
More
RAD: IMMUNITY low > > > > > > high
radar uni uni bi uni PRM PRM: for persons with reduced mobility
RAD: DIRECTION bi uni AWAY: unidirectional motion away from sensor
off PRM AWAY auto auto auto auto: automatic adaptation of field size (small shops)
SMART DAISY CHAIN* 1/2: 1st sensor in chain of 2; 2/2: 2nd sensor in chain of 2
off 1/2 2/2 1/3 2/3 3/3 1/3: 1st in chain of 3; 2/3: 2nd in chain of 3; 3/3: 3rd in chain of 3
ZIP CODE all parameter settings in zipped format POWERSUPPLY supply voltage at power connector
DIAGNOSTICS
(see application note on ZIP CODE) OPERATINGTIME power duration since first startup
ID # unique ID-number RESET LOG delete all saved errors
ERROR LOG last 10 errors + day indication PASSWORD LCD and remotre control password
IR: SPOTVIEW view of spot(s) that trigger detection (0000= no password)
IR: C1 ENERG signal amplitude received on curtain 1 LANGUAGE language of LCD-menu
IR: C2 ENERG signal amplitude received on curtain 2 ADMIN enter code to access admin mode
5
TROUBLESHOOTING
E2 ORANGE LED flashes 2 x. The power supply is too 1 Check power supply (in the diagnostics menu of the LCD).
2 low or too high. 2 Check wiring.
E4 ORANGE LED flashes 4 x. The sensor receives 1 Decrease the angle of the IR-curtains.
4 not enough IR-energy. 2 Increase the IR-immunity filter (values >2.8 m).
3 Deactivate 1 curtain.
ORANGE LED flashes 5 x. The sensor receives 1 Slightly increase the angle of the IR-curtains.
E5
5 too much IR-energy.
The sensor is disturbed by 1 Eliminate the cause of disturbance (lamps, rain cover,
external elements. door controller housing properly grounded).
ORANGE LED is on. The sensor encounters 1 Cut and restore power supply.
a memory problem. 2 If orange LED lights up again, replace sensor.
RED LED flashes The sensor sees the door 1 Move the IR-curtains away from the door.
quickly after an during the assisted setup. 2 Install the sensor as close to the door as possible.
assisted setup. If needed, use a bracket accessory.
3 Launch a new assisted setup.
RED LED lights up The sensor vibrates. 1 Check if the sensor is fastened firmly.
sporadically. 2 Check position of cable and cover.
The sensor sees the door. 1 Launch an assisted setup and adjust the IR angle.
The LCD or remote The sensor is protected by a 1 Enter the right password. If you forgot the code, cut
control does not react. password. and restore the power supply to access the sensor
without entering a password during 1 minute.
6
LED-SIGNAL
Motion Presence
detection detection
INSTALLATION
The sensor should be Do not cover the sensor. Avoid moving objects Avoid highly
fixed firmly to avoid and light sources in reflective objects in
extreme vibrations. the detection field. the infrared field.
MAINTENANCE
It is recommended to clean Do not use aggressive
the optical parts at least once products to clean
a year or more if required due the optical parts.
to environmental conditions.
SAFETY
The door control unit Only trained and Always test the good The warranty is invalid if
and the door cover qualified personnel functioning of the unauthorized repairs are
profile must be correctly may install and setup installation before made or attempted by
earthed. the sensor. leaving the premises. unauthorized personnel.
• The device cannot be used for purposes other than its intended use. All other uses cannot be
guaranteed by the manufacturer of the sensor.
• The manufacturer of the door system is responsible for carrying out a risk assessment and installing the
sensor and the door system in compliance with applicable national and international regulations and
standards on door safety.
• The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate
adjustments of the sensor.
7
TECHNICAL SPECIFICATIONS
Supply voltage: 12 V - 24 V AC +/-10% ; 12 V - 30 V DC +/-10% (to be operated from SELV compatible power supplies only)
Power consumption: < 2.5 W
Mounting height: 2 m to 3.5 m (according to the applicable laws and regulations)
Temperature range: -25°C to +55°C; 0-95% relative humidity, non condensing
Degree of protection: IP54
Noise: < 70 dB
Expected lifetime: 20 years
Applicable directives: RED 2014/53/EU; MD 2006/42/EC; ROHS 2 2011/65/EU
Output: Solid-state-relay (potential and polarity free) Solid-state-relay (potential and polarity free)
Max. contact current: 100 mA Max. contact current: 100 mA
Max. contact voltage: 42 V AC/DC Max. contact voltage: 42 V AC/DC
Holdtime: 0.3 to 1 s
- in switching mode: NO/NC
- in frequency mode: pulsed signal
(f= 100 Hz +/- 10%)
C
Z
H
H
BT
BT
05 50
E R L AU
E R L AU
160 186
T H
T H
EN DIN
W I
W I
E
E
C
C
E
N
E N A
N
N A A D
A D B L R
B L R E S O
E S O A C C
A C C
BEA SA | LIEGE Science Park | ALLÉE DES NOISETIERS 5 - 4031 ANGLEUR [BELGIUM] | T +32 4 361 65 65 | F +32 4 361 28 58 | INFO@BEA.BE | WWW.BEA-SENSORS.COM
BEA hereby declares that the IXIO-DT3 is in conformity with the basic requirements and the other relevant provisions of the directives
2014/53/EU and 2006/42/EC.
Notified Body for EC-type inspection: 0044 - TÜV NORD CERT GmbH, Langemarckstr. 20, D-45141 Essen
EC-type examination certificate number: 44 205 13089612
Angleur, September 2017 Pierre Gardier, authorized representative and responsible for technical documentation
The complete declaration of conformity is available on our website
Only for EC countries: According to the European Guideline 2012/19/EU for Waste Electrical and Electronic Equipment (WEEE)