Material Properties Column Properties: Reinforcement Details
Material Properties Column Properties: Reinforcement Details
LOGO Owner :
Location :
Check by : Engr. Mark Christian D. Esguerra
Mark :
Date :
F2
1/4/2023
ISOLATED FOOTING
0.45 m
σall= 155.00 kPa Length = 1.50 m Cover (mm) = 75.00
1.5 m
γ= 18.00 kN/m3 Width = 1.50 m
Thickness = 0.30 m
Depth = 1.50 m 0.175 m
Applied forces:
Load Case Pu Mx My Fx Fy
qa factor
Units kN kN.m kN.m kN kN
Service Load = 219.50 27.64 5.71 14.39 1.77 1.33 1.5 m
Factored Load = 251.99 31.16 8.06 19.20 2.40 1.00
Check for Soil Pressures (Service Load) Check for Stability (Service Load)
Location Total Pressure Remark Overturning Sliding
Corner 1= 195.77 kPa x-x y-y
x-x y-y
Corner 2= 95.62 kPa Overturn Resisting Overturn Resisting
Corner 3= 59.96 kPa 28.17 215.77814 10.03 215.77814 Ratio Ratio
Corner 4= 160.12 kPa 7.660396646 21.51721646 11.57 94.08
Ratio 0.95 Safe Safe Safe Safe
Ratio 7.66 Pu 6ey 6ex β= 2.57 ACI 11.11.2.1.a req'd n2 = 5.00 7.00 pcs
Formula q= 1± ±
Remark = Safe A B L αs = 40.00 ACI 11.11.2.1.b s (mm) = 144.50 144.50 mm
Overturning about y-y Corner Pressure 1 = 195.77 kPa b1 = 0.38 m
Moment = 10.03 Corner Pressure 2 = 95.62 kPa b2 = 0.66 m
Shear Force = 4.32 Corner Pressure 3 = 59.96 kPa bo = 2.08 m
Total = 10.03 Corner Pressure 4 = 160.12 kPa Critical Area = 0.25 mm2
Resisting about y-y Resultant = 35.58 kN
Footing Weight = 12.15 Check for Shear (Factored Load) γf = 0.66 x-x ACI 13.5.3.2
Soil Weight = 43.97 Wide Beam Shear γf = 0.53 y-y ACI 13.5.3.2
Bouyancy = (4.96) Shear Forces calculated as the volume of γv_x = 0.34 x-x ACI 11.11.7.1
Axial = 164.62 bearing pressures γv_y = 0.47 y-y ACI 11.11.7.1
Total = (6.62) Corner Pressure 1 = 0.440 MPa 𝐽ൗ 0.0655 N/mm2 x-x
𝑐1
Ratio = 21.52 Corner Pressure 2 = 0.270 MPa 0.0858 N/mm2 y-y
Remark = Safe Corner Pressure 3 = 0.540 MPa Vu = 0.74 ACI 11.11.5.2.a
Sliding Calculation Corner Pressure 4 = 0.420 MPa φVu = 1.72 ACI 11.11.5.2.b
kp = 2.78 Maximum Stress = 0.540 MPa Calculation of RC punching shear resistance
Pressure mid d = 82.50 without shear reinforcement (φVn = φVc)
Ultimate Shear Capacity
X-Passive Force = 37.13 Vc = φ0.166λ√f'c - ACI 22.5.5.1 Vc (N/mm2) = 1.38 ACI 11.11.2.1.a
Y-Passive Force = 37.13 Reduction factor φ = 0.750 Vc (N/mm2) = 2.29 ACI 11.11.2.1.b
Friction force = 129.47 λ= 1.000 Vc (N/mm2) = 1.51 ACI 11.11.2.1.c
Safe Factor x-x = 11.57 Vc = 0.584 MPa φVc (N/mm2) = 1.04
This spreadsheets is licensed only to
Safe Factor y-y = 94.08 Ratio = 0.924 Ratio = 0.709
Engr. Mark Christian D. Esguerra
Remark = Safe Remark = Safe for beam shear! Remark = Safe for punching shear!