Professional Documents
Culture Documents
Material Properties Column Properties: Reinforcement Details
Material Properties Column Properties: Reinforcement Details
LOGO Owner :
Location :
Check by : Engr. Mark Christian D. Esguerra
Mark :
Date :
F3
1/4/2023
CANTILEVER FOOTING
0.45 m
155.00 kPa Length = 2.25 m Cover (mm) =
2.25 m
γ= 18.00 kN/m3 Width = 1.50 m
Thickness = 0.35 m
0.175 m
Depth = 1.50 m
Applied forces:
Load Case Pu Mx My Fx Fy
qa factor
Units kN kN.m kN.m kN kN
Service Load = 144.79 0.39 10.30 5.13 9.73 1.33 1.5 m
Factored Load = 163.45 0.04 13.69 6.75 12.16 1.00
Check for Soil Pressures (Service Load) Check for Stability (Service Load)
Location Total Pressure Remark Overturning Sliding
Corner 1= 139.35 kPa x-x y-y
x-x y-y
Corner 2= 0.12 kPa Overturn Resisting Overturn Resisting
Corner 3= 9.13 kPa 3.80 187.92444 12.09 205.87012 Ratio Ratio
Corner 4= 139.35 kPa 49.46116676 17.02749158 30.57 18.37
0.12 kPa Ratio 0.68 Safe Safe Safe Safe
Ratio 49.46 Pu 6ey 6ex β= 2.57 ACI 11.11.2.1.a req'd n2 = 10.00 10.00 pcs
Formula q= 1± ±
Remark = Safe A B L αs = 30.00 ACI 11.11.2.1.b s (mm) = 112.40 129.29 mm
Overturning about y-y Corner Pressure 1 = 139.35 kPa b1 = 0.43 m
Moment = 12.09 Corner Pressure 2 = 0.12 kPa b2 = 0.58 m
Shear Force = 1.79 Corner Pressure 3 = 9.13 kPa bo = 1.59 m
Total = 12.09 Corner Pressure 4 = 139.35 kPa Critical Area = 0.25 mm2
Resisting about y-y Resultant = 41.99 kN
Footing Weight = 31.89 Check for Shear (Factored Load) γf = 0.64 x-x ACI 13.5.3.2
Soil Weight = 100.12 Wide Beam Shear γf = 0.56 y-y ACI 13.5.3.2
Bouyancy = (13.02) Shear Forces calculated as the volume of γv_x = 0.36 x-x ACI 11.11.7.1
Axial = 86.88 bearing pressures γv_y = 0.44 y-y ACI 11.11.7.1
Total = (11.58) Corner Pressure 1 = - MPa 𝐽ൗ 0.0755 N/mm2 x-x
𝑐1
Ratio = 17.03 Corner Pressure 2 = 0.240 MPa 0.0820 N/mm2 y-y
Remark = Safe Corner Pressure 3 = 0.300 MPa Vu = 0.40 ACI 11.11.5.2.a
Sliding Calculation Corner Pressure 4 = 0.290 MPa φVu = 1.72 ACI 11.11.5.2.b
kp = 2.78 Maximum Stress = 0.300 MPa Calculation of RC punching shear resistance
Pressure mid d = 83.75 without shear reinforcement (φVn = φVc)
Ultimate Shear Capacity
X-Passive Force = 43.97 Vc = φ0.166λ√f'c - ACI 22.5.5.1 Vc (N/mm2) = 1.38 ACI 11.11.2.1.a
Y-Passive Force = 65.95 Reduction factor φ = 0.750 Vc (N/mm2) = 2.62 ACI 11.11.2.1.b
Friction force = 112.75 λ= 1.000 Vc (N/mm2) = 1.51 ACI 11.11.2.1.c
Safe Factor x-x = 30.57 Vc = 0.584 MPa φVc (N/mm2) = 1.04
This spreadsheets is licensed only to
Safe Factor y-y = 18.37 Ratio = 0.513 Ratio = 0.386
Engr. Mark Christian D. Esguerra
Remark = Safe Remark = Safe for beam shear! Remark = Safe for punching shear!