Norcure® Realkalization constructive solutions

The Norcure realkalisation system is an


electrochemical treatment for reinstating
passive layer around steel reinforcing

Description of alkalisation Advantages

Norcure realkalisation is a non-destructive treatment  Norcure realkalisation offers major advantages over
which: other methods of concrete repair.

 Restores the alkalinity of carbonated concrete; and  The cause of reinforcement corrosion is addressed
and removed
 Reinstates the passivity of steel reinforcement
 The success of the treatment is easily provable by
 Increases structural service life simple tests

Realkalisation is carried out by applying a safe electric  All rebar within the realkalised treatment zone is
current between the reinforcement in the concrete and a repassivated
temporary, externally mounted anode mesh. During 
treatment, an alkaline electrolyte solution is transported  The non-destructive nature of the treatment which
into the concrete by a process of electro-osmosis, means:
increasing the alkalinity of the cover zone. At the same - major time-savings
time, electrolysis at the reinforcement surface produces a - no noise, dust or environmental pollution
high pH environment, which repassivates the steel - no need for expensive structural support
reinforcement. - no risk of inducing micro-cracks
- minimal disturbance to structure users or residents

 The realkalisation process is silent

 The need for permanent electronic monitoring is


eliminated

 Architectural and exposed aggregate finishes can be


Mechanisms of realkalisation maintained

Concrete

Page 1
Norcure® Realkalization
General technical specification 
 The leads from the reinforcement shall be connected to
Anode : Conductive mesh temporarily the negative pole of the rectifier unit(s)
mounted on concrete surface
Cathode : Existing steel reinforcement  The leads from the mesh shall be connected to the
Electrolyte : Norcure ERA electrolyte, an aqueous positive pole of the rectifier unit(s)
pH controlled solution
Current :  A voltage shall be adjusted to give approximately 1 Amp
Typically 1 A/m2 of concrete surface
density per square metre of concrete surface
Treatment time : Typically 7 - 10 days although
 Current, voltage and efficiency of the anode system
dependant upon steel and concrete
shall be controlled and, if necessary, adjusted
density
throughout the treatment
Applied : Between 10 and 40 V DC
voltage
Testing
pH restoration : > 10 
 Concrete samples shall be taken at intervals to
Preparation prior to treatment determine the degree of realkalisation

 Any existing surface finishes shall be removed  Phenolphthalein indicator shall be used to measure the
depth of realkalisation.
 Any special characteristics of the concrete/structure
shall be determined Post-treatment

 Any cracks, spalls and delaminations shall be located  When sufficient realkalisation is achieved, the anode
and repaired using an approved product from the system shall be removed and the concrete surface
Renderoc Xtra range cleaned and allowed to dry
 All metallic features on the concrete surface shall be  If so required, the concrete surface shall be treated with
located and insulated, or removed an approved, compatible, protective/decorative coating
system
 The thickness of the concrete cover shall be determined
and built up to a minimum of 25 mm if necessary

 Reinforcement continuity shall be examined and, if


necessary, improved to give full continuity
Norcure is a registered trade mark of Vector Corrosion
Treatment Technologies Limited

Installation

 Treatment sections shall be identified to ensure even
current distribution within each section

 Electrical connections to the reinforcement shall be


established Test locations for concrete sampling shall be
determined and marked

 The chosen anode system, consisting of an anode mesh


and an alkaline reservoir, shall be installed

 Electrical connections to the anode mesh shall be


established

Important note:
Fosroc products are guaranteed against defective materials and manufacture and are sold subject to its standard Conditions
for the Supply of Goods and Services, copies of which may be obtained on request. Whilst Fosroc endeavours to ensure that
any advice, recommendation, specification of information it may give is accurate and correct, it cannot, because it has no direct
or continuous control over where or how its products are applied, accept any liability either directly or indirectly arising from the
use of its products, whether or not in accordance with any advice, specification, recommendation of information given by it.

Fosam Company Limited


Telephone: +966 2 637 5345 Fax: +966 2 637 5891 email: fosam@fosroc.com
Head Office
Post Box 11081 Regional Offices
Jeddah Sales Office Tel: (02) 6080999 Fax: (02) 635 3330 Yanbu Tel: (04) 322 4280 Fax: (04) 391 2980
Jeddah – 21453
Jeddah Showroom Tel: (02) 665 0787 Fax: (02) 667 4884 Makkah Tel: (02) 542 0869 Fax: (02) 542 0869
Saudi Arabia Riyadh Tel: (01) 482 9303 Fax: (01) 482 7562 Medinah Tel: (04) 855 0091 Fax: (04) 855 0047
Dammam Tel: (03) 814 1282 Fax: (03) 814 1581 Jubail Tel: (03) 362 3904 Fax: (03) 362 3875

www.fosroc.com Khamis Mushayt Tel: (07) 250 0469 Fax: (07) 250 0469 CSD Tel: (02)637 5345 Fax: (02) 638 0693

Registered Office: Industrial Area, Phase 4, Road No. 414, Street No. 407
Page 2 FO SA/NCRA/09/A

You might also like