You are on page 1of 2

eGrout MC50 constructive solutions

Non shrink electrochemical grout

Uses Instructions for use

eGrout MC50 is used to grout the annular space in Fosroc Preparation


Life Jackets system providing a concrete repair and
electrochemical function simultaneously. The substrate must be free from oil grease or any loosely
adhering material. If concrete surfaces are defective or
Advantages have laintance, they must be cut back to a sound base.

 Non shrink and non metallic. Pre-soaking

 High compressive strength. Generally the repair will be soaked as a result of tidal
actin, if not, soak concrete substrates for a minimum of
 Fluid. two hours continuously prior to placing the grout.
Immediately before placement all free water should be
 Can be pumped or poured. removed.

 Chloride free. Mixing and placing

 Electrochemically compatible with Fosroc Life Jacket For best results a mechanically powered grout mixer
system. should be used. When quantities up to 60 kg are used, a
slow speed drill fitted with a high shear mixer is suitable.
Description Larger quantities will require a high shear vane mixer. Do
not use a colloidal impeller mixer.
eGrout MC50 is supplied as a ready to use dry powder.
To enable the grouting operation to be carried out
The addition of a controlled amount of clean water will
continuously, it is essential that sufficient mixing capacity
produce a fluid grout for pouring or pumping into voids.
and labour are available. The use of a grout holding tank
with provision to gently agitate the grout may be required.
eGrout MC50 is a blend of Portland cements, graded
aggregates and additives. The low water requirement
Consistency of grout mix
produces a fluid grout of high strength with good
workability.
The quantity of clean water required to be added to a 20
kg bag to achieve the desired consistency is given below:
Specification
Flowable: 3.0 litres
All repair grouting within the confines of the Fosroc Life
Jacket system must be carried out with a pre-bagged, non The water should be accurately measured into the mixer.
shrink, electrochemically compatible cementitious grout The total contents of eGrout MC50 bag should be slowly
supplied by a registered firm under the ISO 9002 Quality added and continuous mixing should take place for 5
Assurance Scheme. The compressive strength of the minutes. This will ensure that the grout has a smooth
2
grout shall be at least 60 N/mm at 28 days. even consistency.
The grout must be stored, handled and placed in strict Placing
accordance with the manufacturers instructions. No site
batched additions to the pre-bagged grout shall be o
At 35 C place the grout within 10 minutes of mixing to gain
allowed. the full benefit of the expansion process.
Properties EGrout MC50 can be placed in single pour.
o
At a water powder ratio of 0.15 at 20 C: Pour or pump eGrout MC50 from one point only to
eliminate the entrapment of air. For pumping advice
Test methods Typical result please contact Fosroc.
2
Compressive strength: 12 N/mm at 1 day Curing
2
(BS1881 Part 116) 45 N/mm at 7 days
2
55 N/mm at 28 days After grouting all exposed areas should be cured by
Expansion characteristics: covering with polythene sheet securely taped down at all
(ASTM C827-87) Up to 2% at 24 hours edges.
Electrical resistivity
at 28 days: 9,800 – 11,100 Ohm-cm

Page 1
eGrout MC50
Cleaning Storage

eGrout MC50 should be removed from all tools and Shelf life
equipment with clean water immediately after use.
eGrout MC50 has a shelf life of 12 months if kept in a dry
Cured product can be removed mechanically or with Fosroc store in sealed bags.
Acid Etch.
Storage conditions
Sampling procedure
Store in a cool place and out of direct sunlight. Storage at
Cementitious grouts cannot be tested as concrete. Special high temperature any reduce shelf life.
sampling procedures are required, refer to your local Fosroc
office for further details. Precautions

Technical support Health and safety

Fosroc offers a comprehensive technical support service to eGrout MC50 contains cement powders that when mixed or
specifiers, end users and contractors. It is also able to offer become damp, release alkalis that can be harmful to the
on-site technical assistance, an AutoCAD facility and skin. During use, avoid inhalation of dust and contact with
dedicated specification assistance in locations all over the skin and eyes. Wear suitable protective clothing, gloves,
world. eye protection and a dust mask. The use of a barrier cream
provides additional skin protection. In case of contact with
Limitations eyes, rinse immediately with plenty of clean water and seek
medical advice. In case of contact with skin, rinse with
o
At ambient temperatures above 35 C, the mixed grout plenty of clean water, then cleanse with soap and water. If
should be placed immediately after mixing. Water with a swallowed, seek medical attention immediately – do not
o
temperature less than 20 C should be used for mixing. induce vomiting.

Estimating

Supply

eGrout MC50: 20 kg bags

Yield

Flowable: 10 litres per 20 kg bag

Important note:
Fosroc products are guaranteed against defective materials and manufacture and are sold subject to its standard Conditions
for the Supply of Goods and Services, copies of which may be obtained on request. Whilst Fosroc endeavours to ensure that
any advice, recommendation, specification of information it may give is accurate and correct, it cannot, because it has no direct
or continuous control over where or how its products are applied, accept any liability either directly or indirectly arising from the
use of its products, whether or not in accordance with any advice, specification, recommendation of information given by it.

Fosam Company Limited


Telephone: +966 2 637 5345 Fax: +966 2 637 5891 email: fosam@fosroc.com
Head Office
Post Box 11081 Regional Offices
Jeddah Sales Office Tel: (02) 6080999 Fax: (02) 635 3330 Yanbu Tel: (04) 322 4280 Fax: (04) 391 2980
Jeddah – 21453
Jeddah Showroom Tel: (02) 665 0787 Fax: (02) 667 4884 Makkah Tel: (02) 542 0869 Fax: (02) 542 0869
Saudi Arabia Riyadh Tel: (01) 482 9303 Fax: (01) 482 7562 Medinah Tel: (04) 855 0091 Fax: (04) 855 0047
Dammam Tel: (03) 814 1282 Fax: (03) 814 1581 Jubail Tel: (03) 362 3904 Fax: (03) 362 3875

www.fosroc.com Khamis Mushayt Tel: (07) 250 0469 Fax: (07) 250 0469 CSD Tel: (02) 608 0999 Fax: (02) 638 0693

Registered Office: Industrial Area, Phase 4, Road No. 414, Street No. 407
Page 2 FO SA/EGROUT MC50/09/A

You might also like