Professional Documents
Culture Documents
Wga200359 CL ST 0001 (A)
Wga200359 CL ST 0001 (A)
FOR
AT
Prepared by:
WALLBRIDGE GILBERT AZTEC
60 Wyatt Street, Adelaide SA 5000
Ph: (08) 8223 7433
REV: [A]
DATE: 20/04/2020
APPROVAL REGISTER
The following Australian Standards have been used in the preparation of this design:
Designer HAB
Date 20/04/2020
Page Number W1
In accordance with Australian/New Zealand Standard AS/NZS 1170.2:2011 - Structural design actions Part 2: Wind Actions
Height: z = 3m
Site wind speed (Limit State): Vsit = 40.95 m/s Section 2.2
Minimum Wind Speed (Limit State): Vmin = 30 m/s Section 2.3
DESIGN WIND SPEED (Limit State): Vdes = 41.0 m/s Section 2.3
Design wind pressure (Ultimate), p = C fig.C dyn. 1.01 kPa Section 2.4
= User Input
Inputs
o
Internal Angle of Friction (φ) 30 0.52 rad
Unit Weight ϒsoil 18 kN/m3
Surcharge (Q) 0 kPa
Allowable Bearing (q) 75 kPa
Wind Pressure 1.01 kPa
o
0 0.00 rad
Wall/Fence Dimensions
Permeability 0.3
HeightFENCE 2.8 m
Spacing of Posts 3.5 m
Width (B) 0.3 m
Outputs
Ka 0.33
Kp 3.00
c/h 1.00
Cp,n x Kp 0.36
Pwind(ult) 3.56 kN
Pwind(serv) 2.39 kN
ΣP 3.56 kN
HW 1.70 m