You are on page 1of 9

User Total

Area Equipment Area


No. of Floor User
Room User/s needed (Furniture/ Needed
Users Area Floor
per user Fixture) per F/F
Subtotal Area

House

Petal 0.48 0 0 None 0


Lobby 2.4
Pivotal 0.6 4 2.4 None 0

Petal 0.48 0 0 Shelf 0.6


Garage 1.2
Pivotal 0.6 2 1.2 Car 6

Petal 0.48 0 0 None 0


Garden 2.4
Pivotal 0.6 4 2.4 None 0
None

Petal 0.48 0 Sofa 1.6


Living Area 2.4
Pivotal 0.6 4 2.4 Table 0.3
Chair 0.3

Petal 0.48 0 0 Table 0.3


Leisure Areas 2.4
Pivotal 0.6 4 2.4 Chair 0.16
Locker/
Cabinet/Shelf 0.6

Sofa 1.6

Petal 0.48 0 0 Table 1.2


Dining Area 2.4
Pivotal 0.6 4 2.4 Chair 0.6

Counter 1.6

Petal 0.48 0 0 Counter 1.6


Kitchen 1.2
Pivotal 0.6 2 1.2 Sink 0.5
Ref 1

Petal 0.48 1 0.48 Sink 0.25


Laundry Area 1.68
Pivotal 0.6 2 1.2 Shelf/Cabinet 0.6
Laundry 0.3
Machine
Chair 0.16
Petal 0.48 2 0.96 None 0
Pantry 0.96
Pivotal 0.6 0 0 Shelf/Cabinet 0.6

Petal 0.48 0 0 Lavatory 0.25


Powder Room 0.6
Pivotal 0.6 1 0.6 Toilet Cubicle 0.25

Office Petal 0.48 0 0 Desk 0.6


0.6
Pivotal 0.6 1 0.6 Chair 0.16
Shelves 0.6

T&B Petal 0.48 0 0 Lavatory 0.25


0.6
Pivotal 0.6 1 0.6 Toilet Cubicle 1.875
Bath 3

Petal 0.48 0 0 Bed 2


Bedroom 1.2
Pivotal 0.6 2 1.2 Chair 0.25
Shelf/Cabinet/
0.6
Table
Bathroom 2
Sofa 1.6
F/F Floor Total F/F Grand
Total Circulatio Number of
No. of F/F Area Floor Total Grand Total Area
Area n Area Rooms
Subtotal Area Area

0 0
0 0
0 2.4 0.72 3.12 1 3.12

2 1.2
2 12
13.2 14.4 4.32 18.72 1 18.72

0 0
0 0
0 2.4 0.72 3.12 1 3.12

2 3.2
1 0.3
4.7 7.1 2.13 9.23 1 9.23
4 1.2

2 0.6
4 0.64

2 1.2 4.04 6.44 1.932 8.372 3 25.116

1 1.6

1 1.2
6 3.6

1 1.6 6.4 8.8 2.64 11.44 1 11.44

1 1.6

2 1 4.6 5.8 1.74 7.54 1 7.54


2 2

1 0.25
2 1.2
2.37 4.05 1.215 5.265 1 5.265
2 0.6
2 0.32
0 0
1 2.808
2 1.2 1.2 2.16 0.648 2.808

1 0.25
1 1.43
1 0.25 0.5 1.1 0.33 1.43

1 0.6
2 5.096
1 0.16
1.36 1.96 0.588 2.548
1 0.6

1 0.25
2 14.885
1 1.875
5.125 5.725 1.7175 7.4425
1 3

2 4
2 0.5

2 1.2 9.3 10.5 3.15 13.65 3 40.95

1 2
1 1.6
TOTAL
AREA: 126.88
Ergonometric
Zoning and Special Anthropometric Light Ventilation Accoustics
Equipment

Natural &
High Ceiling,
Public Fluorescent Natural
Large doors
lighting

Natural &
Semi-Private Fluorescent Natural
lighting

Landscapping, Natural &


Public automated Fluorescent Natural
sprinkler lighting

Natural & Split-type and


Split-type
Public High Ceiling Fluorescent
aircon lighting Natural

Noises within
Split-type Natural &
Split-type and should stay
Public aircon, Fluorescent
Natural within as much as
Projector lighting
possible

Natural &
Public Fluorescent Natural
lighting

Natural &
Cooking
Semi-Private Fluorescent Natural
equipments
lighting

Overhead fans, Natural &


Semi-Private Laundry Fluorescent Natural
machines lighting
Natural &
Semi-private Fluorescent Natural
lighting

Natural &
Natural and
Public Exhaust fans Fluorescent
Exhaust fans
lighting

Natural &
Private Computer Fluorescent Window-type
and Natural
lighting

Natural &
Natural and
Semi-Private Exhaust fans Fluorescent Exhaust fans
lighting

Noises outside
window-type Natural & Window-type the room should
Private Fluorescent and Natural not be heard as
aircon
lighting
much as possible
Remarks
Should have an
odor
consideration

Should have an
odor
consideration
Room User/s Area Needed per user