ME-GI/GIE pump
vaporizer unit (PVU)
for marine systems
2 MAN Energy Solutions
ME-GI/GIE pump vaporizer unit 3

ME-GI/GIE
The ME-GI/GIE pump vaporizer unit (PVU) is a
standardized high quality pump unit for supply of
LNG or ethane to MAN B&W two-stroke ME-GI/GIE
engines. With a compact and intelligent design, the
PVU provide a more lean design and integration in

pump
the fuel gas supply system (FGSS).

vaporizer unit Key benefits Working principle

Marine systems
– Low Cost LNG/ethane PVU with The PVU is designed to supply LNG/ The pressurized LNG/ethane flows
embedded redundancy ethane to the pressure and temperature through a compact printed circuit heat
–A  utomatically controlled and required by the MAN B&W two-stroke exchanger, in which it is heated by
integrated in MAN-ES duel-fuel ME-GI/GIE engines. warm glycol water. Fine particles
control system present in the gas are caught by the
– Time between overhaul (TBO) The PVU receives cryogenic LNG/ high pressure filter, before the gas is
cryogenic parts is 6,000 running ethane supplied by a cryogenic directed towards the gas valve train
hours centrifugal pump and is subsequently (GVT) and the engine.
– TBO hydraulic parts is 32,000 pressurized by a high pressure
running hours reciprocating pump, consisting of three The gas pressure delivered to the
–C  ompact design providing minimal cylinders actuated by linear hydraulic engine is controlled by hydraulic flow
footprint and low weight pistons. control of the pump. Individual control
– Worldwide service 24/7 of the three cryogenic pumps heads,
each having 50% capacity of full engine
load. This means that the PVU can still
provide full capacity with only two
cold-ends in service, providing the
redundancy required by the market.
4 MAN Energy Solutions
ME-GI/GIE pump vaporizer unit 5

PVU highlights
Low cost with embedded
redundancy

With a compact and intelligent design,


the PVU introduces a considerable
saving in the complete (FGSS). This is
because of the simplifications
implemented in the design, resulting in
a reduced number of sub-systems and
components, and due to the cryogenic
pumps being actuated individually,
enabling embedded redundancy. This
means that one pump cylinder can be
taken out of service for overhaul, while Extended TBO Engine control integration
the remaining two are fully operational
still supplying 100% of the required The PVU also offers savings to the The PVU control system design is
capacity. In comparison, traditional vessels OPEX trough significant based on knowledge of the ME-GI
crankshaft driven pumps requires two increase in TBO compared to engine design and control system. This
complete units to allow system conventional high pressure pumps. For provides dedicated control with
redundancy. the cryogeninc parts the TBO is 6,000 integrated condition monitoring
running hours and for the hydraulic features. The engine gas pressure and
parts TBO is 32,000 running hours. mass flow demands are instantly
Compact and intelligent design transferred to the PVU control system
and further to the pump module. This
Compared to conventional systems, High reliability and easy results in a very stable and precise gas
the PVU offers a significant reduction maintenance pressure control, in which it secures
in weight and size. This offers a further efficient ramp up and ramp down in all
cost benefit considering installation The PVU is designed for the highest operating conditions. Further, the GVT
costs, such as foundations, piping, standards of quality hence ensuring the downstream of the PVU control system,
cabling, and deck stiffening best reliability on the marked. Easy ensures integrated control with the
maintenance is ensured by design with ME-GI engine. The PVU control system
the operators in mind, with easy access is based on the same hardware
to exchange of spare parts. platform as the ME engine control
system, which means that no extra
MAN-ES strives to use the same spare parts are required.
components on the PVU as use on the
ME-GI/GIE engines in order to minimize
the amount of spareparts onboard. As
an example the controllers (MPC’s) are
identical and interchangeable with
the once use on the main engine.
6 MAN Energy Solutions
ME-GI/GIE pump vaporizer unit 7

Scope
of supply
ME-GI/GIE pump vaporizer unit

Main PVU scope Additional scope offered


by MAN-ES:
–C  ompact vaporizer heated by
glycol water Main components Approval
–C  old-return line for continued – LNG tanks –F
 GSS class approval including PVU
PVU main data (LNG)
circulation – Bunkering station –O
 verall HazOp
(no suction drum needed) – Low pressure feed pump PVU size 1000 3000 5000 7000 8000
–B  low-off valve and safety valves – Glycol water system Control and safety system Nominal mass flow (*1) / m_N,PVU / [kg/h] 1383 2823 4667 6762 7629
–E  lectrical cabinet with 3 x MPC – Nitrogen supply system –F
 GSS safety system with input/output Max SMCR (*2) / max SMCR / [MW] 9,0 18,4 30,3 44,0 49,6
–S  tand-alone hydraulic power supply – Master gas valve from PVU control system, e.g. NG Glycol water flow / m_GW / [kg/h] 43610 81333 117180 176199 216324
(SHPS) (optional) – Low pressure vaporizer (if needed) outlet temperature and pressure Glycol water design heating duty / Q_GW / [kW] 300 600 980 1420 1700
–S  ensors for control and supervision – Gas compressor (if needed) Air consumption / [l/min] 390 l/min actual
–P  ump strainer (standard 160my) –P  iping and cabling Nitrogen consumption / [kg/h] 2-2.5 kg/h
–N  G filter after vaporizer (10my) – Electrical power switch board PVU skid dimensions L x W x H / [mm] 3700 x 2240 x 2000 5000 x 2240 x 2000
–F  ilter for glycol water (250my) PVU skid weight / [ton] 2.5-3.5 3.5-4.5 4-5 4-5 5.5-6
–F  ully automated PVU control system Installation
(*1) Nominal mass flow calculated at reference pressure: 4 bara (for PVU-1000:7000); 1.6bara (PVU-8000:10000)
including supervision of operational – Installation of PVU, electrical cabinet, (*2) Max SMCR based on LHV=48.7MJ/kg; SGC=140g/kWh
conditions HPS unit, glycol water system, MOP
–P  articipation in risk studies (HazOp) screen
–S  upervision of installation – Piping; LNG pipes, HP gas pipes, PVU main data (ethane)
– Commissioning glycol water pipes, control air etc.
–P  articipation of gas trial – Hydraulic hose between PVU and PVU size 2000 4000
–C  lass approval certificate for PVU HPS unit incl. heat tracing Nominal mass flow (*1) / m_N,PVU / [kg/h] 1714 3498
(HazOp/FMEA submission to class – Electrical cabling e.g. between PVU Max SMCR (*2) / max SMCR / [MW] 10,6 21,6
societies) and electrical cabinet Glycol water flow / m_GW / [kg/h] 28221* 52635*
– Installation and operation manuals Glycol water nominal heating duty / Q_GW / [kW] 185 370
–L  ist of capacities etc. Air consumption / [l/min] 390 l/min actual
Nitrogen consumption / [kg/h] 2-2.5 kg/h
PVU skid dimensions L x W x H / [mm] 3700 x 2240 x 2000
PVU skid weight / [ton] 2.5-3.5 3.5-4.5

(*1) Nominal mass flow calculated at reference pressure: 4 bara (for PVU-1000:7000)
(*2) Max SMCR based on LHV=47.5MJ/kg; SGC=152g/kWh
MAN Energy Solutions
MAN PrimeServ Copenhagen
2450 Copenhagen, Denmark
P + 45 33 85 11 00
F + 45 33 85 10 49
pvusales@man-es.com
www.man-es.com

All data provided in this document is non-binding.


This data serves informa­tional purposes only and
is not guaranteed in any way. Depending on the
subsequent specific indivdual projects, the
relevant data may be subject to changes and will
be assessed and determined individually for each
project. This will depend on the particular
characteristics of each individual project,
especially specific site and operational conditions.

Copyright © MAN Energy Solutions. 1510-0281-01