COMPACT CATALOGUE
CONNECTO RS • TE RMI N ATI O N S • J O IN T S • J U M P ER S
CONNECTI O N TE CH N O LOGY • TO O L S
© gjp311 / Fotolia
LET’S GET CONNECTED!
Nexans Power Accessories is the leading European specialized innovator, manufacturer
and distributor of low, medium and high voltage accessories as well as connection
technology for energy transmission and distribution networks.
Nexans is a key driver for the world’s transition to a more connected Wherever electricity is conducted through
and sustainable energy future. For over 120 years, the Group has cables and wires. Wherever cables are
brought energy to life by providing customers with advanced cable connected or energy transmission and dis-
technologies for power and data transmission. The Group designs tribution is required. Wherever safety and
solutions and services along the entire value chain in four main bu- quality have priority.
siness areas: Building & Territories (including utilities and e-mobility),
High Voltage & Projects (covering offshore wind farms, subsea in- WE PROVE COMPETENCE.
terconnections, land high voltage), Telecom & Data (covering data Nexans products ensure operational reli-
transmission, telecom networks, hyperscale data centers, LAN) and ability as network utilisation increases. Our
Industry & Solutions (including renewables, transportation, Oil & references are more than 12 million con-
Gas, automation). nectors and cable lugs, 1.1 million pre-
manufactured accessories and around
Nexans Power Accessories has been a leader in pre-assem- 134,000 jumpers per year.
bled cable accessories for more than 60 years. The company is
represented in more than 40 countries worldwide. WE TAKE RESPONSIBILITY.
As the Centre of Competence for cable
The standard product range of GPH® compression or mechan- accessories, our engineers and technicians
ical connectors and cable lugs is developed and produced have taken on responsibility for cable con-
as well as customized solutions. Nexans also manufactures nection technologies in the Nexans Group.
ready-to-install pre-assembled cable lengths and factory tested
cable bridges for industrial applications. STANDARDS ARE IMPORTANT TO US.
Our accessories meet the requirements of
With the brand name EUROMOLD® we are a European mar- the following standards: EN 61442,
ket leader for medium voltage accessories. We offer the entire HD 629.1, HD 629.2, EN 50180, EN
portfolio of separable connectors for interfaces A to F in 50181, IEC 60137, IEEE 386 & 404,
proven EPDM technology with at least 3 mm conductive jacket. In IEC 61238-1, VDE 0220 T100, etc.
this scope, longtime know-how and technological advance was
successfully transferred into high voltage applications. We WE ARE CERTIFIED.
provide a complete range of cold-shrinkable and slip-on DIN EN ISO 9001:2015,
accessories up to 72.5 kV. For the connection of low and medi- DIN EN ISO 14001:2015,
um voltage cables, a series of Nexans heat-shrinkable termina- DIN EN ISO 50001,
tions and joints up to 42 kV are available. An extensive range of OHRIS
additional equipment and a variety of dedicated installation
training and tooling make Nexans a strong partner in the trans-
mission and distribution of energy.
1
POWER ACCESSORIES FOR ENERGY CABLES
A compact selection of our accessories
up to 42 kV, 1250 A
Examples of application 5
PITO-E - Termination 12
Overview Interface C 35
Slip-on terminations up to 42 kV
2
POWER ACCESSORIES FOR ENERGY CABLES
A compact selection of our accessories
up to 42 kV, 1250 A
Page
Ready-to-install, pre-assembled cables up to 42 kV 52
Tools
Cable preparation tools 84
3
POWER ACCESSORIES FOR ENERGY CABLES
EPDM (ethylene propylene diene monomer)
in connection technology
Why is EPDM used for slip-on accessories all over the world?
EPDM has been used success- to the material caused by elec- stable EPDM material, it is
fully as an insulating and con- tric discharges between the sur- not possible to mount the pin
trol material for several million face of the connector / air and contact in a wrong place, which
of cable connectors worldwide the surface of the connector / often happens using "softer"
for more than 55 years. Com- metal (earthed system parts) materials, even with a built-in
pared with the frequency of is impossible. The EPDM ma- anti-twist safeguard in the cable
which other materials, such as terial does not release any vo- lug area.
silicone, are used for separa- latile substances accumulating
ble connectors, EPDM reaches on the surface having negative • Due to the hard, smooth sur-
more than 95%. Separable effects on the conductivity of the face of the EPDM material,
connectors are used at voltage shielding after a longer period damage caused by animals
levels from 3.6/6 kV to of time. is not known. In this respect,
26/45 kV (52 kV) in the medi- operational reliability in endan-
um voltage range for all possi- • Connectors made of EPDM gered areas is ensured.
ble applications, such as switch meet all international standard
gears, motors, transformers, testings to the utmost satisfac- • Thanks to innovative techno-
trains etc. in both indoor and tion, including the reignition logical advance of the EPDM
outdoor facilities. Outer cone test for detecting a fault, even material and the connector
solutions have also been used at low operating voltages, e.g. designs, multirange connectors
for connecting high-voltage 6/10 kV. are available today that are
installations up to 220 kV for characterised by their ease of
roughly 15 years. • Problems when removing installation.
connectors (if systems are
The following advantages set replaced or moved, even after From an objective point of view,
EPDM in the pole position as decades) caused by the mate- the EPDM material has clear
the insulating and control ma- rial sticking to the bushing of advantages in connector tech-
terial for separable connectors. the system are impossible. The nology over all other materi-
silicone based lubricant that is als, just as silicone for slip-on
• Thick-walled conductive used when assembling the terminations.
EPDM jacket with high mechan- connector, does not diffuse into
ical load capacity. A metal the material, but remains in the
housing is not necessary. gap between connector and
bushing. De-energised con-
• The function of the earth nectors can be removed at any
connection to the conductive time, if required.
EPDM jacket of the connector is
always ensured so that damage • Due to the dimensionally
25-02-2021
4
POWER ACCESSORIES FOR ENERGY CABLES
Examples of application
AIS20 with mechanical cable lug PITO-E on transformer with bushings Transformer connection with 158LR
Transformer connection with 200LR SF-6 system connection with 480TB SF-6 system connection with 480TB+800SA
TS-24CSJ hybrid transition joint AFN10 as a transformer connection AIP20 as a transformer connection
AFN20 for smaller and larger cross-sections GTS1 heat-shrinkable straight joint 24CSJA-S cold-shrinkable straight joint
25-02-2021
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
5
6
25-02-2021
EUROMOLD®
SEPARABLE CONNECTORS
up to 42 kV
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
7
200LR/G
EUROMOLD® Elbow connector
Interface A
up to 24 kV, 250 A
Design 110 mm
1. Conductive EPDM insert with
integrated anti-twist and
locking system
2. Conductive EPDM jacket
3. Insulating EPDM layer
between insert and jacket
(with voltage detection point) 4
4. Type A interface as 1
described by CENELEC
EN 50180 and 50181 5
5. Bolted conductor contact 2
6. Earthing lead 200 mm
3
7. Cable reducer
6
7
Specifications and
standards
The elbow connector 200LR/G
meets the requirements of
CENELEC HD 629.1.
8
Kit contents The kit also comprises:
+ installation instructions
The complete (K)200LR/G
+ silicone grease
elbow connector kit comprises
+ wipers
3 x the following components: + screen wire cable lugs
Conductor contact
200LRMC-25.95
+ + + +
Ordering instructions
Indicate the part number
Dia. over core
when ordering (see table). Ordering part number for (K)200LR/G
Cross- insulation
with mechanical conductor contact LRMC
section (mm)
(mm2)
Order example:
1 elbow connector kit for min. max. without voltage detection point with voltage detection point
12/20 kV, for 35-95 mm² Nominal voltage U0 /U 6/10 kV
with mechanical conductor 25
contact. 35
Order according to the table: 50 13.0 21.0 501470 502527
1 kit – K200LR/G with 70
part number 501471. 95
120
17.0 25.0 502535 502539
Note: The assignment only 150
Nominal voltage U0 /U 12/20 kV (K)
applies to XLPE-insulated
cables (dimensions according 35
to DIN VDE 0276-620) with 50
17.5 25.0 501471 502528
70
extruded conductive screen and
95
stranded conductors. For
120
use with other cable designs 21.5 28.5 502536 502540
150
contact our sales representative.
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
9
200SR/G
EUROMOLD® Straight connector
Interface A
up to 24 kV, 250 A
Design Ø 55 mm
1. Conductive EPDM insert with
integrated anti-twist and
locking system
4
2. Conductive EPDM jacket 6
3. Insulating EPDM layer
between insert and jacket 1
(with voltage detection point)
5
4. Type A interface as
described by CENELEC
EN 50180 and 50181
5. Bolted conductor contact 3
6. Earthing lead
2 280 mm
7. Cable reducer
Specifications and
standards
The straight connector 200SR/G
meets the requirements of
CENELEC HD 629.1.
10
Kit contents The kit also comprises:
+ installation instructions
The complete (K)200SR/G
+ silicone grease
straight connector kit comprises
+ wipers
3 x the following components: + screen wire cable lugs
Conductor contact
200SRMC-25.95
+ + +
Ordering instructions
Indicate the part number Dia. over core
Ordering part number for (K)200SR/G
when ordering (see table). Cross- insulation
mechanical conductor contact SRMC
section (mm)
(mm2)
Order example:
min. max. without voltage detection point with voltage detection point
1 straight connector kit for
Nominal voltage U0 /U 6/10 kV
12/20 kV, for 35-95 mm² with
25
mechanical conductor
35
contact.
50 13.0 21.0 501472 502529
Order according to the table:
70
1 kit – K200SR/G with 95
part number 501473. 120
17.0 25.0 502537 502541
150
Note: The assignment only Nominal voltage U0 /U 12/20 kV (K)
applies to XLPE-insulated ca- 35
bles (dimensions according to 50
17.5 25.0 501473 502530
DIN VDE 0276-620) with 70
extruded conductive screen and 95
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
11
PITO-E
EUROMOLD® Termination
Interface A
up to 24 kV, 250 A
Design Ø
Specifications and
standards
The PITO-E can be used with
equipment interface parts
type A that correspond to the
international standard for outer
cone systems according to
CENELEC EN 50180 and
EN 50181.
ØØ
Ordering instructions
Plug-in termination PITO-E up
to 24 kV.
Dedicated fastening
material:
+ 2 polyamide bolts,
+ 2 polyamide nuts,
+ 2 metal pins. Ø 90
Ø 110
Part number
type U0 /U (kV) In (A) (mm)
PITO-E 12.7/22 250 510 70275
12
CONNECTING POSSIBILITIES
EUROMOLD® PIN-CONNECTOR SYSTEM
Interface A
Dia. 44.5± 0.2
+0.1
Dia. 31 - 0.3
Dia. for
Pin 7.9 +0.02
- 0.05
0
48
U0 / U (Um )
- 0.2
6/10 (12) kV
Interface A 6.35/11 (12) kV
9 min.
250 A outer cone acc. to 8.7/15 (17.5) kV
CENELEC EN 50180 and 12/20 (24) kV
Dia. 48.5 ± 0.2 EN 50181 12.7/22 (24) kV
Bushings
Bushings // Accessories
Accessories// Connection
Connection Connectors //
Connectors
Connectors
Connectors typetype Accessories
Accessories
(K)200LR/G
(K)150DP Elbow connector
Dead-end plug
cable
insulation
(K)151SOP
Stand-off plug
(K)200SR/G
250GP cable Straight connector
Earthing plug earthing
(K)400RTPA tap-off
Reducing tap plug 630/250 A
(K)158LR(/G)
(K)676RTPA tap-off Elbow connector
Reducing tap plug 1250/250 A
(K)152SR(/G)
Straight connector
25-02-2021
Products displayed in grey are generally available, but not part of this catalogue.
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
13
400LR/G
EUROMOLD® Elbow connector
Interface B
up to 36 kV, 400 A
Design 210 mm
1. Conductive EPDM insert
2. Conductive EPDM jacket
3. Insulating EPDM layer
moulded between the insert
and the jacket
4. Type B - 400 A interface
as described by CENELEC
EN 50180 and 50181 4
5. Bolted or crimp conductor
contact 5
6. Cable reducer
1
7. Earthing lead
2
The screen break design 365 mm
enables cable outer sheath 3
testing without removing or
dismantling the connector.
Specifications and
standards 7
The separable connector
400LR/G meets the
requirements of
6
CENELEC HD 629.1.
14
Kit contents The kit also comprises:
+ installation instructions
The complete (K)(M)400LR/G + silicone grease
elbow connector kit comprises + wipers
the following components: + screen wire cable lugs
+ + or + +
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
15
CONNECTING POSSIBILITIES
EUROMOLD® PIN-CONNECTOR SYSTEM
Interface B
6/10 (12) kV
40
min.
6.35/11 (12) kV
8.7/15 (17.5) kV
Interface B 12/20 (24) kV
90± 0.2
400 A outer cone acc. to 12.7/22 (24) kV
CENELEC EN 50180 and 18/30 (36) kV
EN 50181 19/33 (36) kV
11 min.
Equipment
interface dead-ending
of equipment
(K)(M)400DR/G
Dead-end receptacle
(K)(M)400AR-2
Equipment bushing
(K)(M)400T1
Equipment bushing
(K)(M)400AR-1
Equipment bushing
(K)(M)400TE/G
Tee connector
cable
isolation
(K)(M)400SOP
Stand-off plug
cable
earthing
400GP
Earthing plug
25-02-2021
Products displayed in grey are generally available, but not part of this catalogue.
16
INSTALLATION OVERVIEW
Interface C
480TB/G
EUROMOLD® Compact tee connector for application in multiple voltage levels
Connector installation
on the cable
The locking device on the
mechanical conductor
connector TMBC prevents the cable connector
connector housing from sliding reducer housing
back.
lubricate
mechanical
locking device conductor lubricate
conductor
lubricate connector clean up
core
insulation cable cable
extruded reducer reducer
conductive screen
Mechanical conductor
connector
TMBC
on the bushing
clamping socket basic socket
lubricate screw wrench insulating wrench
equipment 22 plug 22
bushing
torque torque
connector
wrench wrench
housing
Earthing and
cable fixing
conductive
rubber
cap
earthing
lead
cable
clamp
25-02-2021
ground
potential
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
17
480TB/G
EUROMOLD® Compact tee connector
for multiple voltage levels
Interface C
up to 42 kV, 630 A/1250 A1)
Design 185
185 mm
mm
1. Conductive EPDM insert
2. Conductive EPDM jacket
3. Insulating EPDM layer
4. Type C1+C2 interface as Dia. 80
described by CENELEC
EN 50180 and 50181
5. Bolted or crimp conductor contact
6. Basic insulating plug 4 9
(with voltage detection point,
standard from 30 kV) 8
5
7. Cable reducer
8. Conductive rubber cap 1 6
9. Clamping screw 430 TCS
(optional M16 stud with spring 320 mm
290 mm 2
washer and nut) Dia. 652)
10. Earth lead 3
7
Specifications and
standards
The 480TB/G separable connector
meets the requirements of 2)
The indicated diameter is a die dimension. Depending on the conductor
CENELEC HD 629.1. ATEX version cross-section used, a deviation of up to +5 mm is possible.
can be delivered on request.
18
Lieferumfang
Kit contents The kit alsoZu einem Satz gehören auch:
comprises:
+ installation instructions
+ Montageanweisung
Theeinem
Zu completeSatz(K)(M)(P)480TB/G tee connector
(K)(M)(P)480TB/G + silicone grease
+ Silikonfett
kit comprises 3 x the following
Kompakt-T-Stecker
Lieferumfang gehören components: + wipers + Reinigungstücher
Zu einem Satz gehören auch:
+ Montageanweisung + screen wire cable lugs
3 x folgende Komponenten:
Zu einem Satz (K)(M)(P)480TB/G + Silikonfett
+ Kabelschuhe für den Schirm
Kompakt-T-Stecker gehören + Reinigungstücher Standard delivery
3 x folgende Komponenten: = gehören auch:
Zu einem Satzrange
+ Kabelschuhe für den Schirm Standard-
=
Lieferumfang + Montageanweisung lieferprogramm
Cable reducer = lieferprogramm
Standard-
Conductor
Zu einem
Schraubkontakt
Clamping
Satz (K)(M)(P)480TB/G Feldsteuereinsatz
CA0 contact Silikonfett For application
+ Schraubanschluss
TMBC
Schraubkontakt
Kompakt-T-Stecker
screw 430TCS
430TCS + gehören + CA0 +
Feldsteuereinsatz Schraubanschluss
TMBC +
CA0 Für die Anwendung+ TMBCwith a compres-
Reinigungstücher
Für die Anwendun
430TCS
+
3 x folgende Komponenten: ++ + + + + mit Pressanschluss
+ sion mit Pressanschlus
conductor
+ Kabelschuhe für den Schirm
sind bei Bestellung
sind bei Bestellun
contact, the cable
die Kabeldaten mit
data, including
die the
Kabeldaten m
Standard-
=
Angabe der Leiter-
M16 Gewinde-
Schraub-
Basic insulating
abschlusseinsatz
= form, des Leiter-
querschnitts und
= shape, cross-section
Angabe der Leiter
lieferprogramm
M16 stud with plug Steckergehäuse and materialform,
of the des Leiter-
bolzen mit Flansch-
flange nut or
Schraubkontakt
M16
mutter Gewinde-
und Feder-
mit Kappe Schraub-
+ rubber cap
abschlusseinsatz
(K)800BIPR/ (K)(M)(P)480BT/G
Feldsteuereinsatz
Connector housing 430CA
Pressanschluss
Cable
des Leitermaterials
TBCFeldsteuereinsatz
reducer erforderlich.Conductor Schraubanschluss
conductor, must
querschnitts und
=
spring
ring washer
und Mutter
bolzen430TCS
mit Flansch- (K)800BIPR/
(M)(P)800BIPA
mit Kappe (K)(M)(P)480BT/G
Steckergehäuse 430CA CA0 TMBCbe indicated Für
Feldsteuereinsatz contactPressanschluss when die Anwendun
des Leitermaterial
and nut
mutter und Feder- +
(M)(P)800BIPA
(K)800BIPR/ + (K)(M)(P)480BT/G + 430CA TBC +TBC
ordering. mit Pressanschlus
erforderlich.
Bestellangaben (M)(P)800BIPA
sind bei Bestellun
ring und Mutter
Bei Bestellung die Artikel- Leiterquer-
Zulässiger Ø
die Kabeldaten m
über der Mehrbereichszuordnung
Ordering
nummer instructions
für Mehrbereichs- schnitt
des
geschälten
Aderisolierung
Artikelnummer für (K)(M)(P)480TB/G mit
Schraubanschluss TMBC
Multirange assignment
Angabe der Leiter
Bestellangaben
anwendung angeben
Indicate the part number for
(siehe Tabelle).
M16 Gewinde-
Schraub-
abschlusseinsatz
Kabels
(mm ) 2
min.
(mm)
Cross-
max.
Dia. over
insulation
core
Zulässiger
(mm)430TCS/mit
mit Schraubkontakt
Ordering part number for (K)(M)(P)480TB/G
Ø M16 Gewindebolzen
form, des Leiter-
querschnitts und
=
multirange application when section
Bei
bolzen Bestellung
mit Flansch- die Artikel- mit Kappe Leiterquer-
Steckergehäuse
(mm 2Nennspannung U
) über
0
der
/U 6/10
with mechanical connector TMBC
Feldsteuereinsatz
kV Mehrbereichszuordnung
Pressanschluss des Leitermaterial
Bestellbeispiel
ordering (see table). (K)800BIPR/ 25 (K)(M)(P)480BT/G schnitt501125/geschälten 430CA Artikelnummer für (K)(M)(P)480TB/G mit
1nummer für Mehrbereichs- 13,0 15,2 TBC
mutter
Satzund Feder-
Kompakt-T-Stecker für 35 14,1
min.
16,3 des 501126
max.
Aderisolierung
with clamping screw 430TCS / with M16 stud
Schraubanschluss TMBC erforderlich.
anwendung
ring
12/20 und 95-300 angeben
kV,Mutter mm² mit(M)(P)800BIPA 50 15,3 17,5
Kabels Nominal voltage U0 /U 6/10 kV
(mm)
70 17,0 19,2
OrderTabelle).
(siehe example:
Schraubanschluss und 95 17,9 25
20,8 )
(mm 213.0 15.2 501127/
Schraubkontakt 430TCS. min. max. 501125/
mit Schraubkontakt 430TCS/mit M16 Gewindebolzen
1 compact tee connector kit
Bestellangaben
120 19,4 22,8
35 14.1 16.3 501128
Bestellen Sie laut Tabelle: 150 20,9 24,3 501126
50 15.3 17.5 Nennspannung U0 /U 6/10 kV
for
Satz 12/20
1BestellbeispielkV, unter
- K480TB/G for 95-300 mm² 185 22,5 25,9 Zulässiger Ø
Bei Bestellung
Artikelnummer
diederArtikel-
501133.conductor
240 25,0 70
28,4 17.0
Leiterquer-
25
19.2
13,0über der
15,2
501129/
501130 Mehrbereichszuordnung
with mechanical
1nummer
Satz Kompakt-T-Stecker 300
für 27,7 95
30,4
schnitt17.9 20.8
geschälten 501125/ 501127/ für (K)(M)(P)480TB/G mit
Artikelnummer
für Mehrbereichs- 35
Nennspannung 14,1
U /U 16,3
12/20
120 des19.4 Aderisolierung
22.8 kV (K)
501126 501128
connector
12/20
Anmerkung: and
kV, 95-300
Die clamping
Zuordnung screw
mm² mit 35 50 20.9 15,3
0
17,5 Schraubanschluss TMBC
anwendung angeben 150
18,3
20,5
Kabels 501131/24.3(mm)
430
gilt nur TCS. Order according
für VPE-isolierte
Schraubanschluss Kabel
und to the50 21,7 70 222.5
185
19,5
(mm ) 501132 17,0
25.9 19,2
(siehe Tabelle).
(Abmessungen 70 21,2
23,4 501129/
table: 1 kitnach DIN VDE
– K480TB/G with 95 25,0 95
240
22,8
25.0 17,928.4 max.
min. 20,8 501127/
mit Schraubkontakt 430TCS/mit M16 Gewindebolzen
Schraubkontakt
0276-620) 430TCS.
mit abschälbaren 120 300
27,012027.7
23,6 30.4 22,8
19,4 501128
501130
part number 501133.
Leitschichten und mehrdrähtigen Nennspannung U /U 6/10 kV
Bestellen
Bestellbeispiel
Leitern.
Sie laut Tabelle: 150
185
25,1
28,5150
26,7 30,1
20,9Nominal voltage U0 /U 12/20
501133/
24,3 0 kV (K)
501134
32,6185 25 18.3 13,0 20.5 15,2
22,5 25,9 501125/
1
3) Satz - K480TB/G unter der
Kompakt-T-Stecker
Da die Abmessungen für für 240 29,2 35
34,6240 35 14,1
25,0 16,3
28,4
501135/
501131/ 501136 501129/
Note: The classification does 300 31,2
50 19.5 21.7 501126
Artikelnummer
Kabel
12/20 der Spannungsebene
kV, 95-300 501133. mm²insulated
mit 50 21.2 15,3
Nennspannung
70 300 U
23.4 17,5
27,7
0
/U 18/30 kV
30,4 501132
(M) 501130
only apply
20,8/36 (42) kVfor polymeric
noch nicht 50 23,8 26,7 70 22.8
95 17,0
25.0 19,2
Schraubanschluss
standardisiert
XLPE cables sind, sind dieund acc.
(dimensions 70 25,5 28,4
120 95 23.6 501137/
17,9
27.0 20,8
Nennspannung U0 /U 12/20 kV (K)
501127/
Anmerkung:
in der Tabelle
Schraubkontakt angegebenenDie
430TCS. Zuordnung 95 27,1
28,6 150
30,0
32,0120
501138
35 25.1 19,4 18,3
28.5 22,8 20,5
to DIN VDE 0276
Leiterquerschnitte und deren 620) with 120 501131/ 501133/ 501128
gilt nur für
Bestellen SieVPE-isolierte
laut Tabelle: Kabel 150 30,1 185 33,5150 50 26.7 20,9 30.1 24,3
19,5 21,7 501132 501134
extrudedder
Zuordnung conductive
Durchmesser screen and 185 31,7 240 35,1
70
185 29.2 22,5 32.6 25,9
21,2 501139/
23,4 501135/
1(Abmessungen
über Satz -
Isolierung nur alsnach
K480TB/G Richt-unter DIN der VDE 240 34,2 37,6 501140 501141/ 501129/
stranded conductors. 300 36,9 300 39,6240 95 31.2 25,0 34.6 25,0
22,8 28,4 501142 501136
werte
0276-620) zu betrachten.
mit Bei der
abschälbaren
Artikelnummer
3)
Since the dimensions
Garniturenbestellung 501133.
für diese for 120
300
Nennspannung 23,6
U27,7
0
Nominal
/U 20,8/36
3)
27,0
30,4 kV (P)voltage U 0
/U 18/30 kV (M) 501130
Leitschichten
Kabel
cables bitten atwir und
Sie, denlevel
voltage mehrdrähtigen
über- 20.8/36 50 23,8 50
26,7 150 23.8 25,1
26.7 28,5
Nennspannung U0 /U 12/20 kV (K) 501133/
Leitern.
prüften Durchmesser über Ader- 70 25,5 70 18525.5 501143/
28,4 26,7
28.4 30,1501137/ 501134
Anmerkung:
(42) kVmit are Die Zuordnung
not yet standardised,120 95 27,1 30,0
95 24035 27.1 18,3
501144
30.0 20,5
29,2 32,6 501138501131/
isolierung anzugeben. 28,6 32,0 501135/
3)
gilt
theDanur diefür
conductor Abmessungen
VPE-isolierte
cross-sections für
Kabel and150 30,1 120 33,5300 50 28.6 19,5 32.0 21,7
31,2 34,6 501136
185 31,7 150 35,1 501132
501145/
Kabel
(Abmessungen
their assignmentder Spannungsebene
nach DIN VDE 240
of diameters 34,2 37,6
70 30.1 21,2 33.5 23,4
Nennspannung 501146 U /U 18/30 kV (M)
185 95 31.7 22,8 35.1 25,0 0501139/
20,8/36
over core(42)
0276-620) mitkVabschälbaren
insulation noch given nicht
in 240 120 5034.2 23,6 37.6 27,0
23,8 26,7 501140 501141/
standardisiert
Leitschichten
the table are to sind,
und sind die
be mehrdrähtigen
considered
300 7036.9 25,5
150 39.6 28,4
25,1 28,5 501137/ 501133/501142
inapproximate
der Tabellevalues.
Leitern. angegebenen When 18595 27,1
26,7Nominal 30,0
30,1 voltage U501138
0
/U 20.8/36 kV3) (P) 501134
120
24023.8 29,2 28,6 32,0
32,6 501135/
Leiterquerschnitte
3)
Da
ordering
Für die Abmessungen
Kupferband- accessories, und
Bei anderen wederen
für Freiluftanwendung
would Für
50
Wird eine ATEX-Zertifizierung
150
300
26.7
30,1 Alle Garnituren sind
33,5 Einsetzbar bis 1250 A
schirm bitte mit Kabeln bitten wir um für 70
Stecker kV benötigt,31,2
bis 1225.5 28.4 34,6
mit Schraub- oder Press- 501143/
bei Verwendung 501136
Zuordnung
Kabel
like to der
KIT MT bestellen. derWerksrückfrage.
you toDurchmesser
ask Spannungsebene indicate the geeignet. 185 27.1 um 31,7
95Werksrückfrage.
bitten wir vor Bestellung 30.0anschluss 35,1lieferbar.
Nennspannung
entsprechender
501144 U0 /U 18/30
Durchführung. 501139/
kV (M)
über
20,8/36
checked
Nexans
Isolierung
diameters
Power Accessories
nur
(42) kVGermany nochoverals Richt-
nicht
core
GmbH
120 24028.6 34,2 32.0 37,6
• Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Tel.: +49 9281 8306-0 501140 501141/
150 300 5030.1 23,8 33.5 26,7
36,9 39,6 501142
werte
standardisiert
insulation. zu betrachten.sind, sind Bei dieder
info.power-accessories@nexans.com • www.nexans-power-accessories.com
185 7031.7 25,5 35.1 28,4 501137/ 501145/
Nennspannung U /U 20,8/36 501146
kV 3)
(P)
Garniturenbestellung
in der Tabelle angegebenen für diese 240 9534.2 27,1 37.6 30,0 5011380
120 28,6 32,0 19
Kabel bitten
Leiterquerschnitte und derenwir Sie, den über- 50 23,8 26,7
15070 30,1
25,5 33,5
28,4 501143/
prüften Durchmesser
Zuordnung der Durchmesser über Ader- 18595 31,7
27,1 35,1
30,0 501144 501139/
isolierung
über Isolierungmit anzugeben.
nur als Richt- 240
120 34,2
28,6 37,6
32,0 501140 501141/
300
150 36,9
30,1 39,6
33,5 501142
werte zu betrachten. Bei der 501145/
For use with For use with For outdoor 185 If an ATEX 31,7 35,1
certification for
Nennspannung All accessories
U available
/U 20,8/36 kVWhen
3) installed on
(P)
Garniturenbestellung fürtypesdiese 501146
25-02-2021
Design
1. Interface designed to fit
480TB/G, 484TB/G or
489TB/G tee connector
2. Bus for 800PB/G
3. Bolted or crimp conductor
contact
4. Conductive EPDM insert
5. Conductive EPDM jacket
6. Insulating EPDM layer
moulded between the insert
and the jacket
7. Cable reducer 320 mm
Specifications and
standards (K)(M)(P) 480TB/G
Compact tee connector
(K)(M)(P) 800PB/G
Coupling connector
(K)(M)(P) 800PB/G
Coupling connector
The 800PB/G coupling connector
meets the requirements of 2)
The indicated diameter is a die dimension. Depending on the conductor
CENELEC HD 629.1. ATEX version cross-section used, a deviation of up to +5 mm is possible.
can be delivered on request.
6/10
K800PB/G 12/20 630/12501) 35 300
M800PB/G 18/30 630/12501) 50 300
P800PB/G 20.8/36 630/12501) 50 240
1)
When installed on appropriate equipment bushing.
20
Kit contents The kit also comprises:
+ installation instructions
The complete (K)(M)(P)800PB/G coupling + silicone grease
connector kit comprises 3 x the following + wipers
components: + screen wire cable lugs
Ordering instructions
Indicate the part number for Dia. over core Multirange assignment
Cross-
multirange application when section insulation (mm) Ordering part number for (K)(M)(P)800PB/G
ordering (see table). (mm2)
min. max. with mechanical connector TMBC
Order example: Nominal voltage U0 /U 6/10 kV
1 coupling connector kit for 25 13.0 15.2
35 14.1 16.3 501147
12/20 kV, for 95-300 mm² with 50 15.3 17.5
mechanical conductor connector. 70 17.0 19.2
Order according to the 95 17.9 20.8
120 19.4 22.8 501148
table: K800PB/G with part 150 20.9 24.3
number 501151. 185 22.5 25.9
240 25.0 28.4 501149
300 27.7 30.4
Note: The classification does Nominal voltage U0 /U 12/20 kV (K)
only apply for polymeric 35 18.3 20.5
50 19.5 21.7 501150
insulated XLPE cables (dimen-
70 21.2 23.4
sions acc. to DIN VDE 0276 95 22.8 25.0
620) with extruded conductive 120 23.6 27.0
150 25.1 28.5
screen and stranded conductors. 185 26.7 30.1 501151
3)
Since the dimensions for 240 29.2 32.6
501152
300 31.2 34.6
cables at voltage level 20.8/36
Nominal voltage U0 /U 18/30 kV (M)
(42) kV are not yet standard-
50 23.8 26.7
ised, the conductor cross- 70 25.5 28.4
sections and their assignment of 95 27.1 30.0 501153
For use with For use with All accessories available When installed on
25-02-2021
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
21
484TB/G
EUROMOLD® Compact tee connector
for multiple voltage levels
Interface C
up to 42 kV, 630 A/1250 A1)
Design 185 mm
1. Conductive EPDM insert
2. Conductive EPDM jacket
3. Insulating EPDM layer
Dia. 80
moulded between the
insert and the jacket
4. Type C - interface as
described by CENELEC
4 9
EN 50180 and 50181
8
5. Bolted or crimp conductor 5
contact 6
1
6. Basic insulating plug (with
voltage detection point) 2
7. Cable reducer 360 mm
8. Conductive rubber cap 3
9. Clamping screw M16 with
spring washer and nut Dia.
10. Earth lead 802)
10
The screen break design enables
cable outer sheath testing without
removing or dismantling the connector.
7
Specifications and
standards
The 484TB/G separable connector
meets the requirements of
2)
The indicated diameter is a die dimension. Depending on the conductor
CENELEC HD 629.1. ATEX version
cross-section used, a deviation of up to +5 mm is possible.
can be delivered on request.
22
Kit contents The kit also comprises:
+ installation instructions
The complete (K)(M)(P)484TB/G + silicone grease
tee connector kit comprises + wipers
+ screen wire cable lugs
3 x the following components:
Standard delivery
range
Conductor
contact For application with a
TMBC compression conductor
connector, the cable
data, including the
shape, cross-section
M16 Basic insulating
Conductor and material of the
stud with plug
contact conductor, must be in-
spring washer (K)(M)(P)800BIPA Connector housing Cable reducer
TBC dicated when ordering.
and nut + rubber cap (K)(M)(P)484BT/G 611CA
Ordering instructions
Indicate the part number for
multirange application when Cross- Dia. over core Multirange assignment
section insulation (mm) Ordering part number for (K)(M)(P)484TB/G
ordering (see table). (mm2)3) min. max. with mechanical connector TMBC
Nominal voltage U0 /U 6/10 kV
Order example:
240 25.0 28.4
1 compact tee connector kit 57381
300 27.7 30.4
for 12/20 kV, for 240-400 mm² 400 30.9 33.6 57382
500 33.7 36.4
with mechanical conductor 57383
630 37.1 40.8
connector. Nominal voltage U0 /U 12/20 kV (K)
240 29.2 32.6
Order according to the 300 31.2 34.6 57387
table: K484TB/G with part 400 34.4 37.8
500 37.2 40.6 57388 57388
number 57387. 630 41.3 45.0 57461
Nominal voltage U0 /U 18/30 kV (M)
Note: The classification does 240 34.2 37.6
300 36.2 39.6 57391
only apply for polymeric 400 39.4 42.8
insulated XLPE cables 500 42.2 45.6
630 46.3 50.0 57392
(dimensions acc. to Nominal voltage U0 /U 20.8/36 kV4) (P)
DIN VDE 0276 620) with 240 34.2 37.6
extruded conductive screen and 300 36.2 39.6 57395
400 39.4 42.8
stranded conductors. 500 42.2 54.6
57396
4)
Since the dimensions for 630 46.3 50.0
For use with For use with All accessories available When installed on
For outdoor
25-02-2021
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
23
804PB/G
EUROMOLD® Coupling connector
for 480TB/G, 484TB/G and 489TB/G
Interface C
up to 42 kV, 630 A/1250 A1)
Design 400 mm
1. Interface designed to fit 290 mm 110 mm
480TB/G, 484TB/G or
489TB/G tee connector
2. Bus for 804PB/G
3. Bolted or crimp conductor
contact
4. Conductive EPDM insert 2
5. Conductive EPDM jacket
6. Insulating EPDM layer 3 8
moulded between the insert 4
1
and the jacket 9
5
7. Cable reducer
8. Conductive EPDM cap 360 mm
6
9. Basic insulating plug Dia.
(with voltage detection point) 802)
10. Earth lead
The screen break design
enables cable outer sheath
testing without removing or 7
10
dismantling the connector.
Specifications and
standards 110 mm 110 mm 110 mm
The 804PB/G coupling connector (K)(M)(P) 484TB/G (K)(M)(P) 804PB/G (K)(M)(P) 804PB/G
Compact tee connector Coupling connector Coupling connector
meets the requirements of
CENELEC HD 629.1. ATEX 2)
The indicated diameter is a die dimension. Depending on the conductor cross-section
version can be delivered on used, a deviation of up to +5 mm is possible.
request.
24
Kit contents The kit also comprises:
+ installation instructions
The complete (K)(M)(P)804PB/G coupling + silicone grease
connector kit comprises 3 x the following + wipers
components: + screen wire cable lugs
Standard delivery
range
Conductor
contact TMBC For application with a
compression conductor
connector, the cable
data, including the
shape, cross-section
M16 and material of the
Contact rod Connector housing Cable reducer Conductor conductor, must be in-
and stud (K)(M)(P)804BP/G 611CA contact TBC dicated when ordering.
Ordering instructions
Indicate the part number for
Cross- Dia. over core Multirange assignment
multirange application when insulation (mm) Ordering part number for (K)(M)(P)804PB/G
section
ordering (see table). (mm2)3) min. max. with mechanical connector TMBC
Nominal voltage U0 /U 6/10 kV
Order example: 240 25.0 28.4
57399
1 coupling connector for 12/20 300 27.7 30.4
kV, for 240-400 mm² with 400 30.9 33.6 57400
500 33.7 36.4
mechanical conductor connector. 630 37.1 40.8
57401
Order according to the Nominal voltage U0 /U 12/20 kV (K)
table: K804PB/G with part 240 29.2 32.6
300 31.2 34.6 57405
number 57405. 400 34.4 37.8
500 37.2 40.6 57406 57388
Note: The classification does 630 41.3 45.0 57462
Nominal voltage U0 /U 18/30 kV (M)
only apply for polymeric
240 34.2 37.6
insulated XLPE cables 300 36.2 39.6 57409
(dimensions acc. to 400 39.4 42.8
500 42.2 45.6
DIN VDE 0276 620) with 630 46.3 50.0 57410
extruded conductive screen and Nominal voltage U0 /U 20.8/36 kV4) (P)
stranded conductors. 240 34.2 37.6
4)
Since the dimensions for 300 36.2 39.6 57413
400 39.4 42.8
cables at voltage level 20.8/36 500 42.2 54.6
57414
(42) kV are not yet standardised, 630 46.3 50.0
the conductor cross-sections and 3)
Other cross-sections available on request.
their assignment of diameters
over core insulation given in
the table are to be considered
approximate values. When
ordering accessories, we would
like to ask you to indicate the
checked diameters
over core insulation.
For use with For use with All accessories available When installed on
For outdoor
25-02-2021
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
25
489TB/G
EUROMOLD® Compact tee connector
for multiple voltage levels
Interface C
up to 42 kV, 630 A/1250 A1)
Design 185 mm
1. Conductive EPDM insert
2. Conductive EPDM jacket
3. Insulating EPDM layer
Dia. 80
moulded between the insert
and the jacket
4. Type C - interface as
described by CENELEC 4 9
EN 50180 and 50181 8
5
5. Bolted or crimp conductor
contact 6
1
6. Basic insulating plug
(with voltage detection point) 2
7. Cable reducer 460 mm
3
8. Conductive rubber cap
9. M16 Clamping screw with Dia. 10
spring washer and nut 1102)
10. Earth lead
The screen break design
enables cable outer sheath
testing without removing or
dismantling the connector. 7
Specifications and
standards
The 489TB/G separable connector 2)
The indicated diameter is a die dimension. Depending on the conductor
meets the requirements of cross-section used, a deviation of up to +5 mm is possible.
CENELEC HD 629.1.
26
The kit also comprises:
Kit contents + installation instructions
The complete (K)(M)(P)489TB/G + silicone grease
tee connector kit comprises 3 x + wipers
+ screen wire cable lugs
the following components:
Standard delivery
range
Conductor
contact
For application with a
TMBC
compression conductor
connector, the cable
data, including the
M16 Basic insulating shape, cross-section
stud with plug Conductor and material of the
spring washer (K)(M)(P)800BIPA Connector housing Cable reducer contact conductor, must be in-
and nut + rubber cap (K)(M)(P)489BT/G 911CA TBC dicated when ordering.
Ordering instructions
Indicate the part number for Dia. over core Article classification
Cross-
multirange application when section insulation (mm) Ordering part number for (K)(M)(P)489TB/G
ordering (see table). (mm2)3)
min. max. with mechanical connector TMBC
Nominal voltage U0 /U 6/10 kV
Order example:
1 compact tee connector kit for 800 40.0 44.6
57199
1000 43.8 48.0
12/20 kV, for 800 mm² with
1200 On request
mechanical conductor connector. Nominal voltage U0 /U12/20 kV (K)
Order according to the
800 44.2 48.0 57200
table: K489TB/G with part
1000 47.8 52.8 57201
number 57200.
1200 On request
Nominal voltage U0 /U 18/30 kV (M)
Note:
800 49.2 53.8 57202
The classification does only
1000 53.0 57.8 57203
apply for polymeric insulated
1200 On request
XLPE cables (dimensions acc.
Nominal voltage U0 /U 20.8/36 kV4) (P)
to DIN VDE 0276 620) with
800 49.2 53.8 57204
extruded conductive screen and
1000 53.0 57.8 57205
stranded conductors.
1200 On request
4)
Since the dimensions for
3)
Other cross-sections available on request.
cables at voltage level 20.8/36
(42) kV are not yet standardised,
the conductor cross-sections and
their assignment of diameters
over core insulation given in
the table are to be considered
approximate values. When
ordering accessories, we would
like to ask you to indicate the
checked diameters over core
insulation.
For use with For use with copper wire For use with For outdoor Components can be When installed on
25-02-2021
copper tape other cable types applications. ordered individually. appropriate equipment
screened cables no earthing
screened cables. please contact our bushing: 1250 A
device is necessary. continuously.
Order: Kit MT. representative.
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
27
809PB/G
EUROMOLD® Coupling connector
for 480TB/G, 484TB/G and 489TB/G
Interface C
up to 42 kV, 630 A/1250 A1)
Design 420 mm
1. Interface designed to fit 300 mm 120 mm
480TB/G, 484TB/G and
489TB/G tee connector
2. Bus for 809PB/G
3. Bolted or crimp conductor
contact
4. Conductive EPDM insert
3 8
5. Conductive EPDM jacket
6. Insulating EPDM layer 4
9
1
moulded between the insert 2
and the jacket 5
7. Cable reducer 460 mm
8. Conductive rubber cap 6
28
Kit contents The kit also comprises:
+ installation instructions
The complete (K)(M)(P)809PB/G + silicone grease
coupling connector kit comprises + wipers
+ screen wire cable lugs
3 x the following components:
Conductor
contact For application with a
TMBC compression conductor
connector, the cable
data, including the
shape, cross-section
and material of the
M16 Conductor conductor, must be indi-
Contact rod Connector housing Cable reducer contact cated when ordering.
and stud (K)(M)(P)809BP/G 911CA TBC
Ordering instructions
Indicate the part number for Dia. over core Article classification
Cross-
multirange application when section insulation (mm) Ordering part number for (K)(M)(P)809PB/G
ordering (see table). (mm2)3)
min. max. with mechanical connector TMBC
For use with For use with copper wire For use with For outdoor When installed on
25-02-2021
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
29
800SA
EUROMOLD® Surge arrester for
480TB/G, 484TB/G and 489TB/G Compact tee connector
Interface C
up to 42 kV, 630 A/1250 A
Design
1. Conductive EPDM insert 110 mm
30
Ordering instructions Order example: Note:
Indicate the type of surge For a max. operating voltage of The order information only
arrester when ordering (see 24 kV and a nominal discharge applies to the use in compen-
table). The part numbers each current of 10 kA, order accord- sated, high-impedance net-
apply to one kit consisting of ing to the table: Surge arrester works.
three surge arresters. type 800SA-10-30N Products for divergent parame-
with part number 85813. ters available on request.
Kompakt- Überspannungs-
(K)(M)(P)484TB/G 800SA Durchführungs-
(K)(M)(P)480BE/G Koppel-
(K)(M)(P)809PB/G Überspannungs-
800SA
T-Stecker verlängerung stecker ableiter
Compact tee connectorableiter
Surge arrester Bushing extender Coupling connector Surge arrester
Typ 484TB/G Typ 800SA Typ 480BE Typ (K)(M)(P)809TB/G Typ 800SA
25-02-2021
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
31
480BE/G
EUROMOLD® Asymmetrical bushing extender
Interface C
up to 42 kV, 1250 A1)
Design 109,3 mm
178,7 mm
69,4 mm
1. Conductive EPDM insert
2. Conductive EPDM jacket
3. Insulating EPDM layer
moulded between the insert
and the jacket 71,4 mm
4. Type C1 + C2 - interface as
described by CENELEC
EN 50180 and 50181
5. Earth lead
4 3 1 2
5
For use with coupling connectors
with compact plug and interface C
equipment bushing as described by
CENELEC EN 50180 and EN 50181.
Specifications and
standards
The 480BE/G bushing extender
meets the requirements of
CENELEC HD 629.1.
32
400TR/800TR/800TR-A
EUROMOLD® Test rod for cable testing
Interface C
400TR 800TR
Design
1. Conductive EPDM insulating
shroud
2. Threaded rod for test
connection
3. M12 nuts for connecting
the lest lead
4. Insulation 1
1
5. Copper test rod stem M12 M12
2
2
3 40 40
3
Installation
The test rod is screwed into the
480
connector instead of the basic 480 800TR-A
insulating plug. Then the test
Screwed adapter
lead is connected to the thread-
800TR-A to be
ed stem and the insulating used with test rod
shroud moved to its final posi- 280 400TR.
tion. 4 280
4
5 M16
Ordering instructions 5
Simply specify test rod 400TR, 4
800TR or screwed adapter
5 110
800TR-A
400TR 36 kV 96 kV 95 kV 70126
800TR 36 kV 96 kV 95 kV 85830
25-02-2021
800TR-A 36 kV 96 kV 95 kV 87493
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
33
POSSIBLE ARRANGEMENTS
Interface C
Schraub-
Basic Basic Schraub-
Basic
abschluss- Schraub-
insulating insulating abschluss-
insulating
einsatz abschluss-
plug plug plug
einsatz
einsatz
Überspannungs-
Surge arrester
Compact Coupling ableiter
800SA
Kompakt-
tee connector Koppel-
connector 800SA
T-Stecker
480TB/G stecker
800PB/G
480TB/G Coupling
800PB/G Koppel-
connector
Compact stecker
800PB/G
Kompakt- 800PB/G
tee connector
T-Stecker
480TB/G Compact
480TB/G Kompakt-
tee connector
T-Stecker
480TB/G
110 480TB/G
Basic Schraub-
Basic
Schraub- Basic
abschluss-
abschluss-
insulating insulating
insulating
einsatz
einsatz
plug plug
plug
Compact Compact
tee connector tee connector
489TB/G Kompakt-T-Stecker
489TB/G
489TB/G
110 110 120 110 120
34
CONNECTING POSSIBILITIES
EUROMOLD® BOLTED CONNECTOR SYSTEM
Interface C
U0 / U (Um )
Dia. 22
min. 0
M16 x 2 - 6H 1.5 - 0.5
6/10 (12) kV
29
min.
6.35/11 (12) kV
8.7/15 (17.5) kV
12/20 (24) kV
90± 0.2
Interface C1+C2 12.7/22 (24) kV
630 A / 1250 A outer cone 18/30 (36) kV
acc. to CENELEC EN 50180 19/33 (36) kV
and EN 50181 20.8/36 (42) kV
11 min.
Equipment dead-ending
interface of equipment (K)(M)400DR-B
Dead-end receptacle
Dia. 70 ± 0.2
(K)(M)400AR-3
Equipment bushing
(K)(M)400AR-4 (K)400LB/G
Equipment bushing Elbow connector
cable to
(K)(M)400AR-5 equipment
Equipment bushing
(K)(M)400SFR-B
Equipment bushing
cable
(K)(M)400SOP-B isolation
Stand-off plug
cable
400GP-B earthing
Earthing plug
(K)(M)(P)440TB/G
Compact tee connector
400PB-XSA
Surge arrester
tap-off
(K)400RTPA 630/250A
Reducing tap plug
in-line
(K)(M)400CP-SC junction
Connecting plug
(K)(M)(P)480TB/G (K)(M)(P)800PB/G
Compact tee connector Coupling connector
in-line (K)(M)(P)484TB/G (K)(M)(P)804PB/G 800SA
junction Compact tee connector Coupling connector Surge arrester
(K)(M)440CP
Connecting plug (K)(M)(P)489TB/G (K)(M)(P)809PB/G
Compact tee connector Coupling connector
25-02-2021
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
35
36
25-02-2021
SLIP-ON TERMINATIONS
up to 42 kV
© zhangyang135769 / Fotolia
25-02-2021
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
37
AIS
Indoor slip-on termination
up to 24 kV
Application U0 / U (Um )
The AIS 20 termination is Another benefit given by using the
suitable for indoor installation AIS termination is the quick and 6/10 (12) kV
on polymeric insulated medium easy assembly. The conductor can 6.35/11 (12) kV
voltage cables with extruded be connected with mechanical 8.7/15 (17.5) kV
easy strip conductive screen cable lugs. The termination is 12/20 (24) kV
or bonded extruded conductive available with additional splitting 12.7/22 (24) kV
screen. With this high quality accessories for three-core, copper
silicone termination, a wide wire screened or copper tape
range of cross-sections screened and armored cables.
is covered per voltage level.
Design
1. Longitudinally sealed
mechanical cable lug
2. Integrated silicone tube
as sealing element when
using mechanical cable lugs
3. High flexibility silicone
rubber housing, ensuring a
perfect fit to the cable even
during load changes
4. Integrated conductive rubber
insert
5. Earth cable lug
6. Heat-shrinkable tube
7. Heat-shrinkable break-out
Specifications and
standards
Meets the requirements of
CENELEC HD 629.1
1)
Other cross-sections are available on request.
2)
When using mechanical cable lugs for conductor cross-section greater than 240 mm2, an additional sealing element is required.
38
Kit contents
• 3 termination housings • 3 mechanical screen wire cable lugs • Additional sealing element
• 3 mechanical cable lugs • Installation instructions for 300 mm2 application
for the conductor • Silicone grease
• Assembly incidentals
150
185 500025 500293
240
150 20.9 35.0 AIS 20
185
5002924) 5000264)
240
300
Nominal voltage U0 /U (Um) 12/20 (24) kV
70
95
120
500027 500268
150
185
240
20.9 35.0 AIS 20
95
120
150
5002944) 5000284)
185
240
300
3)
The indicated diameter is a mould dimension. Depending on the conductor
cross-section used, a deviation of up to +5 mm is possible.
4)
Supplied with additional sealing element.
Note: The classification does only apply for polymeric insulated XLPE
cables (dimensions acc. to DIN VDE 0276 620) with extruded conductive
screen and stranded conductors. Please contact our sales representative,
when using other cable types.
25-02-2021
For use with copper wire For use with copper For use with three-core cables For use with other cable
screened cables no earthing tape screened cables. please contact our types please contact our
device is necessary. Order : KIT MT. representative. representative.
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
39
AIP
Indoor slip-on termination
up to 24 kV
Application U0 / U (Um )
The AIP 20 termination is Another benefit given by using the
suitable for indoor installation AIP termination is the quick and
6/10 (12) kV
on polymeric insulated medium easy assembly. The conductor can 6.35/11 (12) kV
voltage cables with extruded be connected with compression 8.7/15 (17.5) kV
easy strip conductive screen cable lugs. The termination is 12/20 (24) kV
or bonded extruded conductive available with additional splitting 12.7/22 (24) kV
screen. With this high quality accessories for three-core, copper
silicone termination, a wide wire screened or copper tape
range of cross-sections screened and armored cables.
is covered per voltage level.
Design 1
1. Longitudinally sealed
compression cable lug
2. High flexibility silicone
rubber housing, ensuring a 2
1
perfect fit to the cable even
during load changes 3
3. Integrated conductive rubber
insert
4. Earth cable lug
5. Heat-shrinkable tube
6. Heat-shrinkable break-out
2 5
Specifications and 6
standards
Meets the requirements of
CENELEC HD 629.1
4
1)
Other cross-sections are available on request.
40
Kit contents
• 3 termination housings • 3 compression screen wire cable lugs
• 3 compression cable lugs • Installation instructions
for the conductor • Silicone grease
• Assembly incidentals
3)
The indicated diameter is a mould dimension. Depending on the conductor
cross-section used, a deviation of up to +5 mm is possible.
Note: The classification does only apply for polymeric insulated XLPE
cables (dimensions acc. to DIN VDE 0276 620) with extruded conductive
screen and stranded conductors. Please contact our sales representative,
when using other cable types.
For use with copper wire For use with copper For use with three-core cables For use with other cable
25-02-2021
screened cables no earthing tape screened cables. please contact our types please contact our
device is necessary. Order : KIT MT. representative. representative.
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
41
AIN
Indoor slip-on termination
up to 24 kV
Design
1. Longitudinally sealed
mechanical or compression
cable lug
1
2. Silicone tube or cap as
1
additional sealing at the 2
transition of cable lug to the
3
termination housing when
using mechanical cable lugs 2 4
3. High flexibility silicone
rubber housing, ensuring a
perfect fit to the cable even
3
during load changes
4. Integrated conductive rubber
insert 6
5. Earth cable lug
6. Heat-shrinkable tube 4
7. Heat-shrinkable break-out
Specifications and
standards 7
Meets the requirements of
CENELEC HD 629.1
5
42
Kit contents
• 3 termination housings • 3 mechanical or compression screen wire cable lugs
• 3 mechanical or compression • Installation instructions
cable lugs for the conductor • Silicone grease
• Assembly incidentals
2)
Since the dimensions for cables at voltage level 20.8/36 (42) kV are not yet standardised, the
conductor cross-sections and their assignment of diameters over core insulation given in the
table are to be considered approximate values. When ordering accessories, we would like to ask
you to indicate the checked diameters over core insulation.
ØD
Note: The classification does only apply for polymeric insulated XLPE
cables (dimensions acc. to DIN VDE 0276 620) with extruded conductive
screen and stranded conductors. Please contact our sales representative,
when using other cable types.
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
43
Table 2 - Ordering part number
44
AFS
Outdoor slip-on termination
up to 24 kV
Application U0 / U (Um )
AFS terminations are suitable for benefit is the quick and easy 6/10 (12) kV
outdoor installation on polymeric assembly. The conductor is
6.35/11 (12) kV
insulated medium voltage cables connected with mechanical cable
lugs. Available with additional
8.7/15 (17.5) kV
with extruded easy strip conductive
screen or bonded extruded con- splitting accessories for three-core
12/20 (24) kV
ductive screen.This high-quality cables. 12.7/22 (24) kV
silicone termination covers a large
range of cross-sections with just
two sizes per voltage level. Another
Design
1. Longitudinally sealed 1
mechanical cable lug 2
1
2. Integrated silicone tube
as sealing element
3. High flexibility silicone
2
rubber housing, ensuring a 3
perfect fit to the cable even
during load changes 4
4. Integrated conductive rubber
insert 3
5. Earthing clamp
6. Earthing cable lug
7. Heat-shrinkable tube
8. Heat-shrinkable break-out 7
5
5
Specifications and
standards
This termination meets the
6
requirements of 8
CENELEC HD 629.1.
1)
Other cross-sections are available on request.
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
45
Kit contents
• 3 termination housings • 3 mechanical screen wire cable lugs
• 3 mechanical cable lugs • Installation instructions
for the conductor • Silicone grease
• Assembly incidentals
For use with copper wire For use with copper For use with three-core cables For use with other cable
screened cables no earthing tape screened cables. please contact our types please contact our
device is necessary. Order : KIT MT. representative. representative.
46
AFN
Outdoor slip-on termination
up to 42 kV
Design
1. Longitudinally sealed
mechanical or compression
1
cable lug
1
2. Silicone tube or cap as 2
additional sealing at the
transition of cable lug to the 2
3
termination housing when
using mechanical cable lugs 4
3. High flexibility silicone
rubber housing, ensuring a
perfect fit to the cable even 3
Specifications and
standards 9
Meets the requirements of
CENELEC HD 629.1
7
47
Kit contents
• 3 termination housings • 3 mechanical or compression screen wire cable lugs
• 3 mechanical or compression • Installation instructions
cable lugs for the conductor • Silicone grease
• Assembly incidentals
2)
Since the dimensions for cables at voltage level 20.8/36 (42) kV are not yet standardised, the
conductor cross-sections and their assignment of diameters over core insulation given in the
table are to be considered approximate values. When ordering accessories, we would like to ask
you to indicate the checked diameters over core insulation.
ØD
Note: The classification does only apply for polymeric insulated XLPE
cables (dimensions acc. to DIN VDE 0276 620) with extruded conductive
screen and stranded conductors. Please contact our sales representative,
when using other cable types.
25-02-2021
48
Table 2 - Ordering part number
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
49
50
25-02-2021
READY-TO-INSTALL,
PRE-ASSEMBLED CABLES
up to 42 kV
25-02-2021
© artjazz / Fotolia
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
51
READY-TO-INSTALL, PRE-ASSEMBLED CABLES
Interface A to F connectors and terminations
up to 42 kV
Application U0 / U (Um )
Pre-assembled cables are of accessories. The cables 6/10 (12) kV
polymeric insulated medium and flexible cables, primarily 6.35/11 (12) kV
voltage cables, equipped with checked by us, are assembled with 8.7/15 (17.5) kV
connectors and terminations. different conductor cross-sections 12/20 (24) kV
They can be used for and accessories, depending on
connecting transformers and
12.7/22 (24) kV
customer’s application.
switchgears. We manufacture
18/30 (36) kV
the pre-assembled cables 19/33 (36) kV
specifically customized in 20.8/36 (42) kV
terms of cable length and type
Accessory A Accessory B
See table for accessory selection. See table for accessory selection.
Indoor slip-on
Elbow connector termination
K200LR AIS 20
25-02-2021
Dimensioning basis
for wire/cable length
52
Example request
Please fill in what is applicable.
Accessory A
Accessory B
PD
yes / no yes / no yes / no yes / no
sample test
Accessory selection
We also assemble accessories not listed here.
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
53
54
25-02-2021
STRAIGHT JOINTS
TRANSITION JOINTS
up to 42 kV
25-02-2021
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
55
GTS1
Single-core straight joint
Heat-shrink technology
up to 42 kV
Application U0 / U (Um )
The heat-shrinkable straight with different conductor sizes or
joint type GTS1 is suitable for conductor materials becomes fast
6/10 (12) kV
jointing polymeric insulated and easy.
6.35/11 (12) kV
medium voltage cables with 8.7/15 (17.5) kV
extruded easy strip conductive 12/20 (24) kV
screen or bonded extruded 12.7/22 (24) kV
conductive screen. With regards 18/30 (36) kV
to the mechanical conductor 19/33 (36) kV
connector, supplied in the 20.8/36 (42) kV
joint kit, jointing of cables
Design
1. Dual wall tube
2. Stress control tube
3. Stress control mastic 8
4. Overall protection tube 5
5. Sealing mastic
2
6. Screen continuity (copper mesh)
7. Conductor connector 3
8. Screen wire connector
(optionally roll springs) 7
6
9. Sealing mastic 9 3
10. Insulation sleeve 10
(only for cross-sections >630 mm2, L 7
36GTS1 and 42GTS1)
1
Specifications and 4
standards
The heat-shinkable straight joint
GTS1 meets the requirements of
CENELEC HD 629.1.
56
Kit contents The kit also comprises:
+ mechanical conductor connector
The complete GTS1 joint kit + mechanical screen wire connector
comprises the following components: + installation instructions
+ field control mastic
+ wipers
+ silicone grease
+ assembly incidentals
+ + + + + + + = GTS1
Stress Sealing Stress Insulation sleeve Dual Overall Copper mesh Mechanical
control mastic control tube (only for cross-section wall tube protection tube tape connector
mastic >630 mm2, 36GTS1
and 42GTS1)
For use with copper wire For use with copper tape For use with other For use with three-core Jointing cables of Can be used with
25-02-2021
screened cables no further earth- screened cables, endorse "A" cables types cables see GTS3. different sizes possible. all common types of
ing device is necessary. to the part number. please contact our conductor connectors.
(e.g. 24GTS1.240A) representative.
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
57
CSJ
Single-core straight joint
Cold-shrink technology
up to 36 kV
Application U0 / U (Um )
The cold-shrinkable straight different conductor sizes or 6/10 (12) kV
joint type CSJ is suitable for conductor materials becomes
6.35/11 (12) kV
jointing polymeric insulated fast and easy.
medium voltage cables with
8.7/15 (17.5) kV
extruded easy strip conductive
12/20 (24) kV
screen or bonded extruded 18/30 (36) kV
conductive screen. With regards 19/33 (36) kV
to the mechanical conductor
connector, supplied in the
joint kit, jointing of cables with
4
Specifications and
standards 7
The cold-shrinkable straight
joint CSJ meets the requirements 5
of CENELEC HD 629.1.
8
58
Kit contents The kit also comprises:
+ installation instructions
The complete joint kit CSJ + silicone grease
comprises the following + white pen
components: + gloves
+ assembly gauge
+ adhesive tape
+ rubber rings
+ assembly incidentals
24CSJ
+ + + + = or
36CSJ
Nominal
voltage Conductor cross-section (mm2) Dia. over core Max. dia. over
Joint type U0 /U insulation outer sheath
35 50 70 95 120 150 185 240 300 400 500 630 800 1000 (mm) (mm)
(kV)
24CSJ-2 Gr. 1 6/10 537522) 18-23 46
24CSJ-2 Gr. 2 6/10 59088 23-33 46
24CSJ-2 Gr. 1 12/20 59087 18-23 46
24CSJ-2 Gr. 2 12/20 48136 3)
23-33 46
24CSJ-3 12/20 52650 3)
30-54 57
24CSJ-3 12/20 51800 3)
30-54 57
36CSJ-2 Gr. 2 18/30 537382) 23-36 48
36CSJ-2 Gr. 2 18/30 53737 23-36 48
36CSJ-3 18/30 57216 30-50 57
36CSJ-3 18/30 57217 3)
30-50 57
2)
Applicable for aluminum conductors up to 150 mm² and copper conductors up to 120 mm2.
3)
Please consider the maximum outer cable diameter.
For use with Alupe cables For use with other cable For use with Can be supplied as stop For use with fabric tape
25-02-2021
please contact types please contact three-core cables joint. Please contact (graphite) screened cables
our representative our representative see TT-24CSJ. our representative order additional semi-
conductive tape.
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
59
24CSJA-S
Compact single-core straight joint
Cold-shrink technology
up to 24 kV
Application U0 / U (Um )
The cold-shrinkable straight with different conductor 6/10 (12) kV
joint 24CSJA-S is used for sizes or conductor materials 6.35/11 (12) kV
jointing medium voltage cables becomes fast and easy. 8.7/15 (17.5) kV
with a copper wire screen and 12/20 (24) kV
extruded conductive screen. 12.7/22 (24) kV
This product can be installed
where installation space is
limited. With regards to the
mechanical conductor
connector, jointing of cables
1
Specifications and
4
standards
The cold-shrinkable 24CSJA-S
7
joint meets the requirements of
CENELEC HD 629.1.
5
60
Kit contents The kit also comprises:
+ installation instruction
The complete joint kit 24CSJA-S + silicone grease
comprises the following + wipers
components: + installation hook
+ assembly incidentals
+ conductive tape
CSJA-H 24CSJA-S
Cold-shrinkable
joint kit
Highlights
• Compact dimensions allow the easy and space-saving installation.
• LowFor usenumber
with copper wire
of components
For use with
due to pre-assembled
For use with fabric tape For use with French extruded
In case of outer sheathtriple
with
NF C 33-226 cables. conductive layer
layer EPDM device is joint screened
screened cables.
No earthing body cables.on support
copper tape
tube. Order: -AT45
(graphite) screened cables.
Order additional Order additional
necessary. semi-conductive tape: semi-conductive tape
• Fast and easy installation by pulling -SCJ out the support tube(typein TSC)a single movement.
• All joint bodies are electrically tested prior to leaving the factory.
• Cold-shrinkable joints 24CSJA-S exceed international performance standards
including CENELEC HD 629.1 and IEC 60502-4.
• Mechanical connectors and cable lugs supplied in the joint kit are tested and
certified acc. to IEC 61238-1-A.
• No special tools or flame required.
• Advanced screen connection system.
• Cold-shrinkable joints can be energized immediately after installation.
Nominal Conductor cross-section (mm2) Dia. over core Max. dia. over
Joint type voltage insulation outer sheath
U0 /U (kV) 35 50 70 95 120 150 185 240 300 (mm) (mm)
For use with copper wire For use with copper tape For use with Alupe cables Jointing cables of For use with other cable
25-02-2021
screened cables no further screened cables, endorse "A" please contact different sizes possible. types please contact
earthing device is necessary. to the part number. our representative our representative
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
61
GTM3.1
Three-core transition joint
Heat-shrink technology
up to 42 kV
Application U0 / U (Um )
Heat-shinkable transition joint 6/10 (12) kV
for jointing three-core paper
6.35/11 (12) kV
cables to three single-core
polymeric cables. For use
8.7/15 (17.5) kV
with belted or screened
12/20 (24) kV
cables with a common or 12.7/22 (24) kV
individual lead sheath. This 18/30 (36) kV
transition joint is fully screened, 19/33 (36) kV
submersible and suitable to be 20.8/36 (42) kV
directly buried.
Design
1. Dual wall tube
2. Stress control tube
3. Protection tube
4. Field control mastic
5. Sealing mastic
6. Screen wire connector
7. Mechanical conductor
connector
8. Semi-conductive heat-
shinkable breakout
(17GTM3.1)
9. Semi-conductive tube
(17GTM3.1)
10. Barrier tube
11. Heat-shrinkable breakout
Specifications and
standards
The heat-shrinkable transition
joint GTM3.1 meets the
requirements of
CENELEC HD 629.2.
62
Kit contents The kit also comprises:
+ installation instructions
The complete joint kit + mechanical conductor connector
GTM3.1 comprises the + mechanical screen wire connector
following components: + roll springs
+ assembly incidentals
+ copper mesh tape
+ + + + + + + = GTM3.1
Ordering instructions
Conductor cross-
Please indicate the part number Joint Nominal voltage section (mm²) Ordering part
when ordering (see table). type U0 /U (kV) number
min. max.
Select the order designation of
17GTM3.1.95 6/10 25 95 572882)
the transition joint according to 17GTM3.1.240 6/10 95 240 598542)
the cable type used and the 17GTM3.1.300 6/10 120 300 588442)
diameter over core insulation. 17GTM3.1.400 6/10 240 400 572892)
Joint types for connecting 24GTM3.1.50 12/20 35 50 572903)
different conductor cross-sections 24GTM3.1.240 12/20 70 240 572913)
available on request. 24GTM3.1.300 12/20 120 300 582093)
Transition joints for 12/20 (24) kV 24GTM3.1.400 12/20 185 400 572923)
and 18/30 (36) kV H-cables to 42GTM3.1.951) 18/30 + 20,8/36 50 95 572933)
XLPE-insulated single-core 42GTM3.1.1501) 18/30 + 20,8/36 95 150 572943)
cables available on request. 42GTM3.1.2401) 18/30 + 20,8/36 150 240 572953)
42GTM3.1.3001) 18/30 + 20,8/36 120 300 588453)
42GTM3.1.4001) 18/30 + 20,8/36 240 400 572963)
Order example: 1)
The joint type is suitable for voltage levels 18/30 (36) kV and 20.8/36 (42) kV, type
For paper-insulated belted tested for 20.8/36 (42) kV.
cable with 6/10 kV, 3 x 150 mm² 2)
Transition joints for paper-insulated belted cables to XLPE-insulated single-core cables.
to XLPE-insulated single-core 3)
Transition joints for three-core single lead sheath cable to XLPE-insulated single-core
cable with 6/10 kV, 120 mm². cables.
Order according to the table:
17GTM3.1.240 part number
59854.
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
63
SVMS/SVMS-P
In-line joint including mechanical connectors
without/with parking position, design acc. to DIN V 47640
Heat-shrink technology
Application
The heat-shrinkable in-line aluminum conductors. This U0 / U (Um )
joint SVMS/SVMS-P is used for heat-shrinkable joints offer
jointing four- and five-core a sealed indoor or outdoor
0.6/1 (1.2) kV
polymeric insulated cables application.
with concentric conductor and
PVC or XLPE insulation as well
as PVC or PE outer sheaths.
The joints are designed for
use of mechanical connectors
accommodating copper or
D1/d1
he inner and outer heat-
T or application SVMS-P
F
shrinkable tubing is thick- including a parking position
walled and co-extruded with of mechanical contacts on l1
adhesive quality. The joint conductors, a connector without
D2/d2
design and tube dimensions oil stop is mandatory.
are according to DIN V 47640.
l2
Specifications and
standards
Heat-shrinkable tubes meet the
requirements of IEC 60684-
247. The dimensions of the
mechanical connectors, that
have been tested according to
IEC 61238-1-A or VDE 0220
part 100 respectively, corre-
spond to DIN V 47640.
The complete heat-shrinkable
SVMS/SVMS-P joint meets the
requirements of CENELEC EN
50393.
25-02-2021
64
Kit contents
The heat-shrinkable in-line • 4 (5) x inner joints
joints comprise the • 1 x overall protection tube
following components: • 4 (5) x mechanical connectors with/without oil stop
• installation instructions
SVMS HEAT-SHRINKABLE IN-LINE JOINT incl. mechanical connectors with oil stop
up to 0.6/1 (1.2) kV, without parking position for the connectors on the conductors
SVMS-P HEAT-SHRINKABLE IN-LINE JOINT incl. mechanical connectors without oil stop
up to 0.6/1 (1.2) kV, with parking position for the connectors on the conductors
1)
Only for PVC-insulated cables according to DIN VDE 0276-603.
For use with other cross- For use with other cables
25-02-2021
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
65
66
25-02-2021
GPH®
CONNECTION TECHNOLOGY
up to 52 kV
© YiuCheung / Fotolia
25-02-2021
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
67
GPH® D-SERIES
Mechanical Connectors up to 0.6/1 kV
with sector channel, hexagon socket bolts or shear-off-head bolts
D10-35 SV(-T/-S)-V(-K)3) 10-35 35 10-35 35 10-35 35 10-35 10-35 36 16 9.0 SW8 SW5
D25-50 SV(-T/-S)-V(-K) 25-50 35-50 25-50 35-50 25-50 35-50 25-35 50 25-357)
36 18 10.0 SW8 SW5
D4-50 SV(-T/-S)-V-K 10-50 35-50 10-50 35-50 4-50 35-50 4-35 50 4-357) 36 18 10.0 SW52)
D16-95 SV(-T/-S)-V(-K) 16-95 35-95 16-95 35-95 16-95 35-95 16-35 95 16-707) 55 25 14.0 SW10 SW6
D25-150 SV(-T/-S)-V-K 25-150 35-150 25-150 35-150 25-150 35-150 16-35 120-150 25-957)
70 28 17.0 SW6 2,5)
D35-150 SV(-T/-S)-V(-K) 35-150 35-150 50-150 50-150 35-150 35-150 35 120-150 35-957) 70 28 17.0 SW135) SW65)
D25-185 SV(-T/-S)-V-K 6)
25-185 35-185 25-185 35-185 25-185 35-185 25-35 150 25-120 7)
80 32 19.0 SW6 2)
D70-185 SV(-T/-S)-V(-K)6) 70-185 70-185 70-185 70-185 70-185 70-185 150-185 70-1207) 80 32 19.0 SW13 SW6
D50-240 SV(-T/-S)-V-K 6)
50-240 50-240 50-240 50-240 50-240 50-240 240 50-185 7)
120 35 22.0 SW6 2)
25-02-2021
D120-240 SV(-T/-S)-V(-K) 6)
120-240 120-240 120-240 120-240 120-240 120-240 240 120-185 7)
120 35 22.0 SW13 SW6
D50-300 SV(-T/-S)-V(-K)6) 50-300 50-300 50-300 50-300 50-240 50-240 240 95-185 128 38 23.0 SW82)
D150-300 SV(-T/-S)-V(-K)6) 150-300 150-300 150-300 150-300 150-240 150-240 240 150-185 128 38 23.0 SW13 SW8
1)
Connector Body: Brass 3)
Without sector channel 5)
Bolt, brass (tin plated) 7) Contact sleeves available on request
2)
Double shear-off-head bolt 4)
Hexagon socket bolt, steel 6) With four shear-off head bolts
68
Bolt system
We use grub screws with inner The torque moments follow the respective conductor types.
hexagons as well as single and the rule that large conductor Grub screws are tightened with
multiple shear-off-head bolts cross-sections need higher the prescribed torque.
that are equipped with an inner torque moments and
or outer hexagon. Both are smaller cross-sections need
related to the various shear-off- lower torque moments. The
areas of the bolt and different installation instruction describes
torque moments. the use of both hexagons for
Ordering instructions
Please indicate the part num- Mechanical connector type Ordering part number
Al
Cu
It is possible to connect It is possible to connect
25-02-2021
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
69
GPH® D-SERIES
Mechanical Cable Lugs up to 0.6/1 kV
with sector channel, hexagon socket bolts or shear-off-head bolts
Application Advantages
Using GPH® D-Series mechan- · Simple, quick installation: · Universal applicability:
ical cable lugs allows larger With common commercially Can be used for copper and
conductor cross-section ranges available inner and outer aluminum conductors according
even for low voltage applications, hexagon tools or an approved to EN 60228 classes 1 & 2. For
irrespective of the conductor impact wrench. use with flexible copper conduc-
material, shape and design. tors class 5, please contact us.
Mechanical cable lugs are
standard tin-plated and · Minimum storage costs: · Proven quality:
offered with different palm The cross-section range GPH® D-Series mechanical
hole diameters. from 1.5 mm² to 300 mm² cable lugs allow long-lasting
is covered by just 3 types of contact quality of the
cable lugs. application.
D25-50 x 10(12) SK-V-K 25-50 35-50 25-50 35-50 25-50 35-50 25-35 50 25-355) 40 18 10.0 16 SW8
D16-95 x 10(12) SK-V-K 16-95 35-95 16-95 35-95 16-95 35-95 16-35 95 16-705) 52 25 14.0 24 SW10
D35-150 x 12(16) SK-V-K 35-150 35-150 50-150 50-150 35-150 35-150 35 120-150 35-955) 60 28 17.0 31 SW133)
D25-185 x 10(12/16) SK-V-K4) 25-185 35-185 25-185 35-185 25-185 35-185 25-35 150 25-1205) 77 32 19.0 37 SW61)
D70-185 x 10(12/16) SK-V-K4) 70-185 70-185 70-185 70-185 70-185 70-185 150-185 70-1205) 77 32 19.0 37 SW13
D120-240 x 12(16) SK-V-K4) 120-240 120-240 120-240 120-240 120-240 120-240 240 120-1855) 97 35 22.0 56 SW13
D50-300 x 12(16) SK-V-K4) 50-300 50-300 50-300 50-300 50-240 50-240 240 95-185 105 38 23.0 60 SW81)
25-02-2021
D150-300 x 12(16) SK-V-K4) 150-300 150-300 150-300 150-300 150-240 150-240 240 150-185 105 38 23.0 60 SW13
1)
Double shear-off-head bolt 3)
Bolt, brass (tin-plated) 5)
Contact sleeves available on request
2)
Without sector channel 4)
With two shear-off-head bolts Other palm holes on request.
70
Bolt system
We use grub screws with inner The torque moments follow respective conductor types.
hexagons as well as single and the rule that large conductor Grub screws are tightened with
multiple shear-off-head bolts cross-sections need higher the prescribed torque.
that are equipped with an inner torque moments and smaller
or outer hexagon. Both are cross-sections need lower
related to the various shear-off- torquemoments. The installation
areas of the bolt and different instructiondescribes the use
torque moments. of both hexagons for the
Ordering instructions
Please indicate the part number Mecanical cable lug Ordering part number
Product range
Please find the entire overview
of our products for
conductor connections
in our catalogue
GPH® Connection technology.
Al
Cu
It is possible to connect It is possible to connect Different designs Can be used for all
25-02-2021
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
71
GPH® M-SERIES
Mechanical Connectors up to 52 kV
with shear-off-head bolts and transverse grooving
Design b
Material
Connector body: high strength d D
aluminium alloy
Bolts: brass, tin-plated, L
M16-95 16-95 16-95 25-70 16-95 25-70 2 70 12.5 24 32 SW10 & SW6
M25-150 25-150 25-150 35-120 25-150 35-120 2 85 15.5 30 35 SW10 & SW6
M95-240 95-240 95-240 95-185 95-240 95-185 4 120 20 33 56 SW13 & SW6
M95-240/ 1st side 95-240 95-240 95-185 95-240 95-185 20 SW13 & SW6
4 120 33 56
16-95 2nd side 16-95 10-95 25-703) 16-95 25-703) 12.5 SW6
M95-300 95-300 95-300 95-240 70-300 70-240 4 142 231)
36 67 SW13 & SW8
M95-300/ 1st side 95-300 95-300 95-240 70-300 70-240 231) 67 SW13 & SW8
4 142 36
16-95 2nd side 16-95 10-95 25-703) 10-70 25-703) 12.5 67 SW6
M185-400 185-400 185-400 185-300 185-400 185-300 6 170 26 42 82 SW19 & SW6
5 200 52
120-300 2nd side 120-300 120-300 120-240 120-300 120-240 25 67 SW19 & SW6
M630-10002) 630-1000 630-1000 630-1000 8 220 41 65 105 SW19 & SW8
1)
Dimension d1 = 26 mm Centric conductor positioning by center inserts
2) 3)
Round pressed 4)
Other dimensions on request
72
M630-1000/ 1st side 2) 630-1000 630-1000 630-1000 41 105 SW19 & SW8
7 220 65
185-400 2nd side 185-400 185-400 185-300 185-400 185-300 26 105 SW19
Technical details
Shear-off-head bolts are equip- The torque moments follow the The installation instruction
ped with an inner and outer rule that large conductor cross- describes the use of both
hexagon. Both are related to sections need higher torque hexagons and of the various
the various shear-off-areas of moments and smaller cross- center rings and inserts for the
the bolt and different torque sections need lower torque respective conductor types.
moments. moments.
Ordering instructions
Please indicate the part num- Mechanical connector type Ordering part number
ber when ordering (see table). M16-95 G6402 50 31
The center rings or inserts are
M25-150 G6402 50 15
included in the set.
M25-150/16-95 G6402 50 37
M70-240 G6402 50 60
Order example
1 mechanical connector for M95-240 G6402 50 16
Al
Cu
It is possible to connect We use center rings for It is possible to connect Different designs Can be used for all
25-02-2021
different conductor the centric positioning of small different conductor cross- available. conductor shapes.
materials. conductor cross-sections. sections.
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
73
GPH® C-SERIES
Mechanical Cable Lugs up to 52 kV
with shear-off-head bolts and transverse grooving
Surface
Connector body: tin-plated Centric conductor channel,
M70-240
C70-240
with shear-off-head bolts and M95-300
C95-300
transverse grooving
M ...
M95-300
M70-240
M ...
M70-240
M95-300
C16-95 x 12 13
16-95 16-95 25-70 16-95 25-70 1 60 12.5 24 32 SW10 & SW6
C16-95 x 16 17
C25-150 x 12 13
25-150 25-150 35-120 25-150 35-120 1 79 15.5 30 35 SW10 & SW6
C25-150 x 16 17
C70-240 x 12 13
70-240 70-240 70-240 70-240 70-240 2 93,5 221) 35 56 SW13 & SW6
C70-240 x 16 17
C95-240 x 12 13
95-240 95-240 95-185 95-240 95-185 2 95 20 33 56 SW13 & SW6
C95-240 x 16 17
C95-300 x 12 13
95-300 95-300 95-240 70-300 70-240 2 105 231) 36 67 SW13 & SW8
C95-300 x 16 17
C120-300 x 12 13
120-300 120-300 120-240 120-300 120-240 2 105 25 38 67 SW19 & SW6
C120-300 x 16 17
C185-400 x 12 13
185-400 185-400 185-300 185-400 185-300 3 120 26 42 82 SW19 & SW6
C185-400 x 16 17
C300-500 x 12 13
C300-500 x 16 300-500 300-500 300-400 300-500 300-400 3 130 34 52 94 17 SW19 & SW8
C300-500 x 20 21
C400-630 x 12 13
C400-630 x 16 400-630 400-630 400-500 400-630 400-500 3 130 34 52 94 17 SW19 & SW8
C400-630 x 20 21
25-02-2021
C630-1000 x 202) 630-1000 630-1000 630-1000 4 165 41 65 105 21 SW19 & SW8
C800-1200 x 202) 800-1200 630-1200 630-1000 4 170 45 72 105 21 SW22 & SW8
1)
Dimension d1=26 mm
2)
Centric conductor positioning by center inserts
74
Technical details
Shear-off-head bolts are equip- The torque moments follow the The installation instruction
ped with an inner and outer rule that large conductor cross- describes the use of both
hexagon. Both are related to sections need higher torque hexagons and of the various
the various shear-off-areas of moments and smaller cross- center rings and inserts for the
the bolt and different torque sections need lower torque respective conductor types.
moments corresponding. moments.
Ordering instructions
Please indicate the part number Mechanical cable lug type Ordering part number
when ordering (see table). C16-95 x 12 G6502 40 20
The center rings or inserts are C16-95 x 16 G6502 40 33
included in the set. C25-150 x 12 G6502 40 09
C25-150 x 16 G6502 40 84
Order example: C70-240 x 12 G6502 40 36
1 mechanical cable lug C70-240 x 16 G6502 40 40
for 95-300 mm², palm hole
C95-240 x 12 G6502 40 10
dia. 17 mm. C95-240 x 16 G6502 40 17
Order according to the table:
C95-300 x 12 G6502 40 88
1 mechanical cable lug
C95-300 x 16 G6502 40 92
C95-300 x 16 with part
C120-300 x 12 G6502 40 23
number G6502 40 92.
C120-300 x 16 G6502 40 26
C185-400 x 12 G6502 40 30
Specifications and C185-400 x 16 G6502 40 19
standards C300-500 x 12 G6502 40 34
Mechanical connectors C300-500 x 16 G6502 40 37
have been electrically tested C300-500 x 20 G6502 40 41
according to IEC 61238-1-A C400-630 x 12 G6502 40 28
or VDE 0220 part 100 C400-630 x 16 G6502 40 31
respectively. C400-630 x 20 G6502 40 29
C630-1000 x 20 G6502 51 10
Product range C800-1200 x 20 G6502 51 12
Please find the entire overview
of our products for conductor
connections in our catalogue
GPH® connection technology.
Al
Cu
It is possible to connect We use center rings for It is possible to connect Different designs Can be used for all
25-02-2021
different conductor the centric positioning of small different conductor cross- available. conductor shapes.
materials. conductor cross-sections. sections.
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
75
GPH® Compression cable lugs, Cu
Standard type, with and without inspection hole
Product range
Please find the entire overview
of our products for conductor
connections in our catalogues
GPH® Connection technology.
Design
Material
Connector body: Copper, tin-plated
Palm: plan stamped
Type
KU-L: without inspection hole KU-L KU-L-S
KU-L-S: with inspection hole
76
GPH® Compression cable lugs, Cu
Standard type, with and without inspection hole
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
77
GPH® Compression cable lugs, Cu
Acc. to DIN 46235
Product range
Please find the entire overview
of our products for conductor
connections in our catalogue
GPH® Connection technology.
Design
Material
Connector body: Copper
Surface
KU: uncoated KU KU-V
KU-V: tin-plated
Cable lug type Conductor cross-section, Dimensions Palm hole Die code Number of Weight
stranded (mm) dia. no. compressions 100 pcs.
(mm²) (mm) (approx. kg)
KU KU-V d l b mech. hydr.
6 x 5 KU 6 x 5 KU-V 5.4
6 3.8 24 8.5 5 1 0.6
6 x 6 KU 6 x 6 KU-V 6.5
These cable lugs are manufactured as a special model, different from DIN 46235.
25-02-2021
2)
78
GPH® Compression cable lugs, Cu
Acc. to DIN 46235
Cable lug type Conductor cross- Dimensions Palm hole Die code Number of Weight
section, (mm) dia. no. compressions 100 pcs.
stranded (mm) (approx. kg)
KU KU-V (mm²) d l b mech. hydr.
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
79
GPH® Compression cable lugs, Al
Longitudinally sealed, acc. to DIN 46329
Design
Material
Connector body: Aluminum
Palm: plan stamped
Surface
ALU-F: uncoated ALU-F ALU-F-V
ALU-F-V: tin-plated
Cable lugs filled with compound
and sealed in plastic.
Cable lug type Conductor cross-section Dimensions Palm hole Die code Number of Weight
(mm²) (mm) dia. no. compres- 100 pcs.
(mm) sions (approx. kg)
ALU-F ALU-F-V rm/sm se d l b mech. hydr.
25 x 8 ALU-F1) 25 x 8 ALU-F-V1) 20 8.5 1.5
25 x 10 ALU-F1) 25 35 6.8 50 25 10.5 12 4 2 1.4
25 x 12 ALU-F1) 25 x 12 ALU-F-V1) 25 13.0 1.4
35 x 8 ALU-F 35 x 8 ALU-F-V 8.5 2.6
35 x 10 ALU-F 35 x 10 ALU-F-V 35 50 8.0 62 25 10.5 14 5 2 2.4
35 x 12 ALU-F 35 x 12 ALU-F-V 13.0 2.3
50 x 8 ALU-F 50 x 8 ALU-F-V 8.5 2.5
50 x 10 ALU-F 50 x 10 ALU-F-V 50 70 9.8 62 25 10.5 16 5 2 2.4
50 x 12 ALU-F 50 x 12 ALU-F-V 13.0 2.3
70 x 10 ALU-F 70 x 10 ALU-F-V 10.5 3.5
70 95 11.2 72 25 18 6 3
70 x 12 ALU-F 70 x 12 ALU-F-V 13.0 3.3
1)
Palm width and height do not comply with DIN 46329.
80
GPH® Compression cable lugs, Al
Longitudinally sealed, acc. to DIN 46329
Product range
Please find the entire overview
of our products for conductor
connections in our catalogue
GPH® Connection technology.
Cable lug type Conductor cross- Dimensions Palm Die code Number of Weight
section (mm²) (mm) hole dia. no. compressions 100 pcs.
(mm) (approx. kg)
ALU-F ALU-F-V rm/sm se d l b mech. hydr.
185 x 10 ALU-F 185 x 10 ALU-F-V 10.5 11.1
185 x 12 ALU-F 185 x 12 ALU-F-V 185 240 18.3 91 30 13.0 28 6 3 11.0
185 x 16 ALU-F 185 x 16 ALU-F-V 17.0 11.2
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
81
82
TOOLS
for the installation of power accessories
83
CABLE PREPARATION TOOLS
for accessories installation in medium voltage applications
Peeling tool with stop Order numbers: peeling tool 51494 / spare cutter 51495
ring, size 1
The peeling tool is suitable for than described, the cutting depth of
removing the extruded outer semi- the blade can be adjusted up to a
conductive cable screen of medium maximum of 1.2 mm. By using the
voltage cables. Field of application: tool with length control the semi-
10 kV 25 mm2 up to 30 kV 500 con layer can be removed between
mm2 cables, diameter over core 25 mm up to 100 mm measured
insulation between 10 mm up to 52 from cut-off edge of outer cable
mm. The cutting depth is preset for sheath. Stop rings included in the
semi-con screens acc. to VDE 0276 kit.
part 620. In case of thicker screens
2-in-1 Cable sheath and Order numbers: cable sheath 59117 / spare cutter 51488
cable insulation cutter,
The tool is engineered for profes- designed to provide spiral cutting
size 1
sional and safe stripping of the ou- (longitudinal) as well as circumfer-
ter cable sheath of medium voltage ential cutting. The blade is specially
cables. Field of application: 10 kV formed with a guiding system lifting
25 mm2 up to 30 kV 500 mm2 the material while cutting it to avoid
single-core cables, diameter over any damages to the layers under-
outer sheath between 15 mm up to neath. Cutting depth is adjustable.
57 mm. The tool is also suitable for
removing polymeric insulation of
medium voltage cables in the afore
mentioned range. It has been
Chamfering tool, size 1 Order numbers: chamfering tool 43523 / spare cutter 44129
This very simple to handle tool sheath. Due to its specially formed
removes sharp edges at the cut-off blade a radius is produced at the
edge of cable insulation to avoid cut-off edge. This reduces the force
possible damage to and to ease required to install non-size sensitive
installation of slip-on accessories. slip-on accessories enormously.
Field of application: 10 kV 25 mm2
up to 30 kV 500 mm2 cables acc. to
VDE 0276 part 620, diameter over
core insulation between 12 mm up
to 45 mm after peeling the outer
Insulation stripping tool Order numbers: 40001 for 10 kV; 40002 for 20 kV; 40003 for 30 kV
Order numbers: spare cutter 41083 for 10 kV; 41084 for 20 kV; 41085 for 30 kV
voltage cables. Separate tools for preset cutting depth prevents dam-
voltage level of 10 kV, 20 kV and aging the cable conductor.
30 kV can be delivered. Therefore,
no adjustment of voltage level or
84
CABLE PREPARATION TOOLS
for accessories installation in medium voltage applications
and cables with conductor cross-sections > 500 mm2
Peeling tool with stop Order numbers: peeling tool 55152 / spare cutter 51495
ring, size 2
The peeling tool is suitable for adjusted up to a maximum of 1.2
removing the extruded outer semi- mm. By using the tool with length
conductive cable screen of medium control the semi-con layer can be
voltage cables with diameters over removed between 25 mm up to 100
core insulation between 10 mm mm measured from cut-off edge
up to 60 mm. The cutting depth is of outer cable sheath. Stop rings
preset for semi-con screens acc. included in the kit.
to VDE 0276 part 620. In case of
thicker screens than described, the
cutting depth of the blade can be
2-in-1 Cable sheath Order numbers: cable sheath 59118 / spare cutter 55541
and cable insulation The tool is engineered for profes- as well as circumferential cutting.
cutter, size 2 sional and safe stripping of the The blade is specially formed with
outer cable sheath of medium a guiding system lifting the ma-
voltage single-core cables with dia- terial while cutting it to avoid any
meters over outer sheath between damages to the layers underneath.
32 mm up to 70 mm. The tool is Cutting depth is adjustable.
also suitable for removing poly-
meric insulation of medium voltage
cables in the afore mentioned
range. It has been designed to
provide spiral cutting (longitudinal)
Chamfering tool, size 2 Order numbers: chamfering tool 55154 / spare cutter 44129
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
85
CABLE PREPARATION TOOLS
for accessories installation in medium voltage applications
Kit contents
Rigid case with foam pads, two-in-one cable sheath and cable insulation cutter, chamfering tool,
devices (stop rings, silicone grease and Allen key for tooling adjustments).
25-02-2021
86
DMV65
Torque amplifier with tool case
Ordering instructions
Technische Eigenschaften
3-Kant Aufnahme zur Aufnahme von handelsüblichen Akkuschrauber-Dreibackenfutter.
-
Type Max. engine torque ½“Package
Vierkant zum Aufnehmen
- Dimensions Weight
von handelsüblichen Steckschlüsseleinsätzen und Inbus Eins
(Nm) Übersetzungsverhältnis 1:24 (mm)
- (g)
Länge Stange: 80,5mm
-
Maximales Abtriebsdrehmoment von 65Nm
-
DREHMOMENTVERSTÄRKER DMV65
65 Tool caseAntriebsdrehmoment
Minimales
- 375 x 240
von x3,5Nm
120 2600
25-02-2021
IM KOFFER Antrieb bricht bei Fallhöhe 1m auf Betonboden nicht ab, fest eingeschraubte Gabeln verbie
-
Einseitiges Anliegen an Verbinderkörper und 65Nm Anzugsmoment: Gabeln verbiegen nic
-
Keine Ausfälle durch normale Verschmutzungen bei regulären Gebrauch in Bauste
-
Verschmutzung durch Sand, etc.!!!)
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 •IP54
- Schutzart: 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • -www.nexans-power-accessories.com
ACHTUNG: Nicht für Schlagschrauber geeignet!!!
Beschriftung:
87
DMV65
Torque amplifier, isolated, with tool case
81
SW5, 6, 8, 10 for Ø < 36 mm
• Hexagon socket key SW5 • Outer tapped hole
• Instruction manual for Ø < 48 mm
• Gearbox, insulated
• Triangle
239
• Hexagon socket key SW5
Ordering instructions
DREHMOMENTVERSTÄRKER
65 Tool case 375 x 240 x 120 3000
POTENTIALGETRENNT DMV65
88
iDMV65
Torque amplifier iDMV65 with integrated drive and tool case
Ordering instructions
DREHMOMENTVERSTÄRKER MIT
INTEGRIERTEM ANTRIEB iDMV65 65 Tool case 340 x 230 x 70 4200
IM KOFFER
Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
info.power-accessories@nexans.com • www.nexans-power-accessories.com
89
CATALOGUE SELECTION
Here you can find all available catalogues of our GPH®, EUROMOLD®
and Nexans products. You can order these catalogues directly by phone
or download from our web page.
www.nexans-power-accessories.com
90
CABLE DATA SHEET
INQUIRY FORM
Nexans Power Accessories Company:
Germany GmbH Customer ID:
Ferdinand-Porsche-Straße 12 Address:
D-95028 Hof/Saale
Phone: +49(0)9281 / 8306 - 0
Fax: +49(0)9281 / 8306 - 480
E-Mail: info.power-accessories@nexans.com Phone:
Fax:
E-Mail:
Cable designation
Cable data
Single-core Single-core flexible rubber insulated cable
Thre-core Three-core flexible rubber insulated cable
Other Standard
Conductor material
Aluminum cross-section mm²
Copper
Conductor shape
Round stranded (compacted) conductor RM(V)
Round solid conductor RE
Sector stranded conductor SM
Sector solid conductor SE
Flexible conductor RF Other
1. Ø conductor mm
2. Ø over core insulation mm XLPE PVC EPR
3. Ø over semi-conductive screen mm
4. Semi-conductive layer bonded graphite coated easy strip
25-02-2021
91
92
NOTES
25-02-2021
Technical instructions and application information
The data given were determined diligently, but do not release our customers of the duty to carry out tests themselves in order to check the
suitability of the products delivered by us for the intended use. We reserve the right to modify characteristic and performance data according
to the present state of technology. Processing and use of the products cannot be controlled by us and are therefore exclusively in your field
of responsibility.
Our products meet the VDE standards respectively correspond to DIN pages and IEC recommendations.
The products, described in this catalogue, are designed for connection of bare energy cable conductors (Class 1 & 2) with description of round
solid (RE), round stranded (RM), as well as sector solid (SE), sector stranded (SM) and round stranded compacted (RMV) for conductor
temperatures up to 90 °C. All conductor filling materials like tapes, yarn, powder or similar need to be completely removed before the
installation. A check on basis of the actual existing conductor dimensions by the user is indispensable. This applies also for the application of
Class 6 conductors or other special conductor types.
Impact wrenches have to be approved by Nexans! Depending on different conductor material or conductor type, indicated values may differ
from test values acc. to IEC 61238-1. The use of fine stranded conductors has to be approved by Nexans Power Accessories Germany GmbH.
Our responsibilities are only those listed in the latest edition of “General terms and conditions for the supply of products and services of the
electrical and electronics industry”. We can provide a copy on request.
Our products are mainly delivered in cartons. We only use package materials able to be recycled due to the latest packing system. Collapsible
cardboard boxes are not taken back. Please try to order complete standard packages.
Reprinting, even partial, only with special allowance. We reserve the right to alter or modify the characteristics described. Illustrations and
drawings may only show a close reflection and are not decisive. The weights are approximate and include the carton package. This catalogue
substitutes all former editions. Types or versions not part of the catalogue are available on request.