Skylight element: GT
Version 7.9.4_24917 (2022-08-01)
Revision 1 — August 1, 2022
Release Notes Skylight element: GT Version 7.9.4

Publication Information
Skylight element: GT Version 7.9.4 Release Notes
Revision 1 — Publication date: August 1, 2022

Trademark Information
© 2022 Accedian Networks Inc. All rights reserved. Accedian™, the Accedian logo™, Skylight™, Skylight
Interceptor™ and per-packet intel™, are trademarks or registered trademarks of Accedian Networks Inc.
To view a list of Accedian trademarks visit: http://accedian.com/legal/trademarks.
All other company and product names may be trademarks of their respective companies. Accedian may,
from time to time, make changes to the products or specifications contained herein without notice. Some
certifications may be pending final approval; please contact Accedian for current certifications.
Accedian’s products are protected by patents as indicated on Accedian’s website, located at
http://www.accedian.com/en/legal.html
The mention of any product herein does not constitute an endorsement by Accedian Networks Inc.
The content of this publication is provided for informational use only, is subject to change without notice
and should not be construed as a commitment by Accedian Networks Inc. Accedian Networks Inc. assumes
no responsibility or liability for any errors or inaccuracies that may appear in this document.
Except as expressly permitted in writing, no part of this publication may be reproduced, stored in any
retrieval system, or transmitted, in any form or by any means, electronic, mechanical, recording, or
otherwise, without prior written consent of Accedian Networks Inc.
Changes are periodically made to the information herein; these changes will be incorporated into new
editions of this publication. Accedian Networks Inc. may make improvements and/or changes in the
products and/or software programs described in this publication at any time.

Contact
If you have comments regarding this manual, please address them to:

Accedian Networks Inc.


Attention: Technical Publications
2351 Alfred-Nobel Blvd., Suite N-410
Saint-Laurent, Québec
Canada H4S 2A9
techpubs@accedian.com

Tel: 514-331-6181
Fax: 514-331-2210
Toll free: 1-866-685-8181
accedian.comaccedian.com

Revision 1 — August 2022 2


Release Notes Skylight element: GT Version 7.9.4

Table of Contents
1. About This Document ......................................................................................... 5
1.1 Organization.................................................................................................................................................. 5
1.2 Conventions ..................................................................................................................................................6
1.3 Related Documentation ............................................................................................................................. 7
1.4 Product Name Changes ............................................................................................................................. 7

2. Requirements....................................................................................................... 8
3. Firmware Version 7.9.4_24917 (2022-08-01) ...............................................9
3.1 New Features and Enhancements .........................................................................................................9
3.2 Addressed Issues ....................................................................................................................................... 10
3.3 Operational Considerations and Known Limitations ...................................................................... 12
3.4 MIB Changes .............................................................................................................................................. 24

4. Firmware Version 7.9.3_24427 (2021-12-15) ............................................... 25


4.1 New Features and Enhancements ....................................................................................................... 25
4.2 Addressed Issues ...................................................................................................................................... 26
4.3 Operational Considerations and Known Limitations ...................................................................... 27
4.4 MIB Changes .............................................................................................................................................. 39

5. Firmware Version 7.9.2_24262 (2021-09-24) ............................................ 40


5.1 New Features and Enhancements ...................................................................................................... 40
5.2 Addressed Issues ...................................................................................................................................... 42
5.3 Operational Considerations and Known Limitations ..................................................................... 44
5.4 MIB Changes .............................................................................................................................................. 56

6. Firmware Version 7.9.1_23672 (2020-11-12) ................................................ 57


6.1 New Features and Enhancements ....................................................................................................... 57
6.2 Addressed Issues ...................................................................................................................................... 58
6.3 Operational Considerations and Known Limitations ..................................................................... 60
6.4 MIB Changes ............................................................................................................................................... 72

7. Firmware Version 7.9_22663 (2020-03-25)................................................ 73


7.1 New Features and Enhancements ....................................................................................................... 73
7.2 Addressed Issues ....................................................................................................................................... 73
7.3 Operational Considerations and Known Limitations ..................................................................... 74
7.4 MIB Changes .............................................................................................................................................. 86

8. Firmware Version 7.8.3_20905 (2019-08-16) ........................................... 87


8.1 New Features and Enhancements ...................................................................................................... 87
8.2 Addressed Issues ......................................................................................................................................88

Revision 1 — August 2022 3


Release Notes Skylight element: GT Version 7.9.4

9. Firmware Version 7.8.2.1_20416 (2019-06-04) ........................................ 89


9.1 New Features and Enhancements ...................................................................................................... 89
9.2 Addressed Issues ...................................................................................................................................... 89

10. Firmware Version 7.8.2_20146 (2019-05-10) ............................................ 90


10.1 New Features and Enhancements ...................................................................................................... 90
10.2 Addressed Issues ...................................................................................................................................... 90

11. Firmware Version 7.8.1_19220 (2018-12-21)............................................... 93


11.1 New Features and Enhancements ...................................................................................................... 93
11.1.1 Robustness Improvements .................................................................................................... 94
11.2 Addressed Issues ...................................................................................................................................... 94

12. Firmware Version 7.8_18628 (2018-10-31) ................................................ 95


12.1 New Features and Enhancements ...................................................................................................... 95
12.1.1 Robustness Improvements .................................................................................................... 96
12.2 Addressed Issues ...................................................................................................................................... 97

13. Firmware Version 7.7_17244 (2018-06-22) ................................................ 98


13.1 New Features and Enhancements ...................................................................................................... 98
13.2 Addressed Issues .................................................................................................................................... 100

14. Firmware Version 7.6_15744 (2018-02-02) ..............................................102


14.1 New Features and Enhancements .....................................................................................................102
14.2 Addressed Issues .................................................................................................................................... 104

15. Firmware Version 7.5_13705 (2017-08-24) ............................................... 107


15.1 New Features and Enhancements ..................................................................................................... 107
15.2 Addressed Issues .................................................................................................................................... 108

16. Firmware Version 7.4_11358 (2017-03-16) ............................................... 109


16.1 New Features and Enhancements .................................................................................................... 109
16.2 Addressed Issues ..................................................................................................................................... 110

17. Firmware Version 7.3.0.3_10522 (2016-12-12) ........................................... 113


17.1 New Features and Enhancements ...................................................................................................... 113
17.2 Addressed Issues ......................................................................................................................................113

18. Firmware Version 7.3.0.2_9184 (2016-09-09) ......................................... 114


18.1 New Features and Enhancements ..................................................................................................... 114
18.2 Addressed Issues ..................................................................................................................................... 114

19. Firmware Version 7.3.0.1_8962 (2016-08-12) ........................................... 115


19.1 New Features and Enhancements ......................................................................................................115
19.2 Addressed Issues ..................................................................................................................................... 116

Revision 1 — August 2022 4


Release Notes Skylight element: GT Version 7.9.4

1. About This Document


These release notes cover the requirements, new features, changes, addressed issues and
known limitations for the Skylight Element: GT firmware version 7.9.4. Please read all the
notes prior to installing this firmware version. For more information, refer to docs.accedian.io,
features and user material for Skylight performance elements: GT.

1.1 Organization
This manual includes the following sections:
Requirements
This section provides requirements for Firmware Version 7.9.4.
Firmware Version 7.9.4_24917 (2022-08-01)
This section provides New Features and Enhancements, Addressed Issues, Operational
Considerations/Known Limitations and MIB Changes, if any, for Firmware Version 7.9.4.
Firmware Version 7.9.3_24427 (2021-12-15)
This section provides New Features and Enhancements, Addressed Issues, Operational
Considerations/Known Limitations and MIB Changes, if any, for Firmware Version 7.9.3.
Firmware Version 7.9.2_24262 (2021-09-24)
This section provides New Features and Enhancements, Addressed Issues, Operational
Considerations/Known Limitations and MIB Changes, if any, for Firmware Version 7.9.2.
Firmware Version 7.9.1_23673 (2020-11-12)
This section provides New Features and Enhancements, Addressed Issues, Operational
Considerations/Known Limitations and MIB Changes, if any, for Firmware Version 7.9.1.
Firmware Version 7.9_22663 (2020-03-25)
This section provides New Features and Enhancements, Addressed Issues, Operational
Considerations/Known Limitations and MIB Changes, if any, for Firmware Version 7.9.
Firmware Version 7.8.3_20905 (2019-08-16)
This section provides New Features and Enhancements, Addressed Issues, Operational
Considerations/Known Limitations and MIB Changes, if any, for Firmware Version 7.8.3.
Firmware Version 7.8.2.1_20416 (2019-06-04)
This section provides New Features and Enhancements as well as Addressed Issues for
Firmware Version 7.8.2.1.
Firmware Version 7.8.2_20146 (2019-05-10)
This section provides New Features and Enhancements as well as Addressed Issues for
Firmware Version 7.8.2.

Revision 1 — August 2022 5


Release Notes Skylight element: GT Version 7.9.4

Firmware Version 7.8.1_19220 (2018-12-21)


This section provides New Features and Enhancements as well as Addressed Issues for
Firmware Version 7.8.1.
Firmware Version 7.8_18628 (2018-10-31)
This section provides New Features and Enhancements as well as Addressed Issues for
Firmware Version 7.8.
Firmware Version 7.7_17244 (2018-06-22)
This section provides New Features and Enhancements as well as Addressed Issues for
Firmware Version 7.7.
Firmware Version 7.6_15744 (2018-02-02)
This section provides New Features and Enhancement as well as Addressed Issues for
Firmware Version 7.6.
Firmware Version 7.5_13705 (2017-08-24)
This section provides New Features and Enhancement as well as Addressed Issues for
Firmware Version 7.5.
Firmware Version 7.4_11358 (2017-03-16)
This section provides New Features and Enhancement as well as Addressed Issues for
Firmware Version 7.4.
Firmware Version 7.3.0.3_10522 (2016-12-12)
This section provides New Features and Enhancement as well as Addressed Issues for
Firmware Version 7.3.0.3.
Firmware Version 7.3.0.2_9184 (2016-09-09)
This section provides New Features and Enhancement as well as Addressed Issues for
Firmware Version 7.3.0.2.
Firmware Version 7.3.0.1_8962 (2016-08-12)
This section provides New Features and Enhancement as well as Addressed Issues for
Firmware Version 7.3.0.1.

1.2 Conventions
This section explains the conventions that are used in Accedian user documentation.

General conventions used in all documents


Notes contain information that emphasizes or supplements certain points in the main text.
Notes are enclosed in blue lines, for example:

Note: This description cannot be modified.

Revision 1 — August 2022 6


Release Notes Skylight element: GT Version 7.9.4

Cautions describe situations in which failure to take an action or avoid an action could result in
damage to equipment or make it impossible to access the system. Cautions are enclosed in red
lines, for example:

CAUTION: If you modify a Management interface, you and other users may lose
access to the Web interface and the CLI.

1.3 Related Documentation


The following documents provide additional information about the GT Performance Element:
• Skylight Element: GT CLI Command Guide (embedded in docs.accedian.io).

1.4 Product Name Changes


The following Accedian products were renamed in March 2020. References to these products
in this document reflect the new naming conventions.

Former Name Former Name New Name

antMODULE ant Module Skylight sensor: module 10G


Skylight element: 1GE
MetroNID GT GT Performance Element Skylight element: GT
MetroNID GX GX Performance Element Skylight element: GX
MetroNID TE TE Performance Element Skylight element: TE
MetroNODE 10GE 10GE Performance Element Skylight element: 10GE
MetroNODE CE CE Performance Element Skylight element: 1GE
MetroNODE GE GE Performance Element n/a
MetroNODE NE NE Performance Element n/a
MetroNODE LT LT Performance Element Skylight element: LT/LX
NanoNID/nanoNID Nano Module Skylight sensor: module 1G
VeloCITY FS FS Performance Element Skylight element: FS
VeloCITY FS 10G FS 10G Performance Element Skylight element: FS-10G

Revision 1 — August 2022 7


Release Notes Skylight element: GT Version 7.9.4

2. Requirements
This firmware version applies to the following Skylight element: GT, resulting from changes in
the TLS version, the following software versions are compatible with SkyLIGHT Director
Vision 1.3 (now Skylight orchestrator) and above:
• 7.1.1.1
• 7.3.0.3
• 7.4
• 7.5
• 7.6
• 7.7
• 7.8
• 7.8.1
• 7.8.2
• 7.8.2.1
• 7.8.3
• 7.9
• 7.9.1
• 7.9.2
• 7.9.3
• 7.9.4

Note: There is a patch available for earlier versions of Skylight orchestrator. Please
contact Accedian support for further information.

Revision 1 — August 2022 8


Release Notes Skylight element: GT Version 7.9.4

3. Firmware Version 7.9.4_24917 (2022-08-01)

3.1 New Features and Enhancements

AC-23623 GT: Respin with a new FPGA


Created new version of GT using Xilinx Kintex instead of Spartan 6. Xilinx had issues
producing Spartan 6 and needed to switch to another FPGA in order to keep selling GT.

AC-22957 Update dropbear SSH to version 2022.82


Updated to latest dropbear version to avoid vulnerabilities.

AC-22729 ICMP redirect security issue


The ICMP Redirect configuration feature supports disabling/enabling ICMP Redirect feature
via CLI/WEB interface.

Revision 1 — August 2022 9


Release Notes Skylight element: GT Version 7.9.4

3.2 Addressed Issues

AC-24913 ERP ring traffic interrupted after configuration change and reboot
User changed ERP version from 2 to 1, and then back to 2, on a working ERP ring in the LAG
port. Traffic was initially okay but the device stopped traffic after reboot.
This issue has been fixed.

AC-24300 Consolidated interface with ":" unable to show/edit using CLI


User cannot show or edit interface using the CLI. If the interface is created using the
GUI, and user tries to edit/show using the CLI, they received the error message: Error:
Invalid alias number.
This issue has been fixed.

AC-24153 Unit unable to sync with NTP server after upgrade to 7.9.2
The unit is unable to sync with NTP server after upgrade to 7.9.2. One-Way delay
measurements were impacted and high-resolution sync was not established.
This issue has been fixed.

AC-22118 Security assessment reported vulnerabilities


User performed security assessment using firmware 7.9, and discovered vulnerabilities on
this device, including:
• Empty password field in /etc/passwd
• No authentication for single user mode
• DOM-based cross site scripting vulnerability
• ICMP redirection enabled
• TLS/SSL Server supports the use of Static Key Ciphers
• ICMP timestamp response
• TCP timestamp response
• TLS/SSL Server Does Not Support Any Strong Cipher Algorithms
• Password hashes in /etc/passwd
• User home directory mode unsafe
• User home directory mode unsafe
• Weak permissions for Password, Shadow and Group Files
• Logging of Security authorization messages.

These issues have been fixed.

Revision 1 — August 2022 10


Release Notes Skylight element: GT Version 7.9.4

AC-22103 LLDP not advertising IP address correctly


User did some testing using firmware 7.9 and 7.9.1 and observed error with LLDP. When
trying to display the LLDP information, user could not see Neighbor IP management
advertisement. This would only be displayed when user enabled the "Primary" (System
>Configuration > Interface) checkbox of the management IP that was configured.
These issues have been fixed.

AC-21895 The PTP Master port does not work after deleting interface
While the PTP is running, changing the configuration of the assigned interface on a specific
PTP port will result in non-deterministic behavior, for example: change VLAN type T-Vlan
to C-Vlan, delete interface. A good practice is to disable and re-enable the PTP after
changing the interface's configuration.
This issue has been fixed.

AC-21754 Unable to become PTP slave port after IPv6 VLAN connection re-establishment
While the PTP is running, changing the configuration of the assigned interface on a specific
PTP port will result in non-deterministic behavior, for example: change VLAN type T-VLAN
to C-VLAN.
A good practice is to disable and re-enable the PTP after changing the interface's
configuration.
This issue has been fixed.

Revision 1 — August 2022 11


Release Notes Skylight element: GT Version 7.9.4

3.3 Operational Considerations and Known Limitations


Important Notes

 The Skylight element: LX firmware is delivered in a consolidated file prefixed by “ACC”,


e.g. ACC_7.X_YYYY.afl. This file contains the firmware for the GT, GX , LX and LT
Performance Element products. It cannot be used with any other product.
 IMPORTANT: Prior to upgrading the firmware on a unit where the History Buckets
feature is enabled, certain precautions may need to be taken to prevent a loss of history
data during the upgrade. Refer to ATRC-B10797 for details.
 In a G.8032 ring configuration, the Skylight element: LX supports a maximum of 62
policies on the LAG port (i.e. policies that govern how traffic is dropped from the ring to
UNI ports). This limitation does not apply to the UNI ports (i.e. policies that govern how
traffic is added to the ring) unless the VLAN-tagged customer traffic is passed
transparently from the UNI port to the ring through one-to-one mapping.
One way to avoid this limitation and maximize the number of usable UNI policies is to
encapsulate multiple customer VLANs (coming from the UNI) under a single service
provider VLAN on the ring. Doing so reduces the number of policies required by the LAG
port.

AC-24052 Unable to send file after upgrade due to syntax change


After upgrading to 7.9.1 or 7.9.2, the SCP is no longer able to send files, reporting the
following error: Code = 3: URL using bad/illegal format or missing URL.

Workaround: Customer needs to edit the URL after upgrading to 7.9.2 or 7.9.3.

AC-22752 TWAMP Sync issue when reflector is an Accedian device with 6.4.x software or
older
A sync compatibility with older software will cause a sync error when generating
TWAMP towards a device using older software (ex: TE device). The impact is the absence
of one-way delay measurement. There is no workaround available for this issue.

ATRC-D15900 LBR message still occurs when MIP and MEP are different VLAN type
Unicast CFM-LBM frames sent to Accedian Demarcation devices are VLAN TPID unaware.

Revision 1 — August 2022 12


Release Notes Skylight element: GT Version 7.9.4

ATRC-D17907 Missing packets on RFC2544 generator layer-3 (2 flows)


With an RFC2544 generator layer-3 that has flow 1 set as QinQ and flow 2 set as no
encapsulation (or QinQ), packets are missing on flow 2 after completing the RFC2544 with
two flows.

ATRC-D17871 Error loading proper page indexing when loading pages via URL/back
Possible error loading proper page indexing when loading WEB pages that contain paged
tables via URL (i.e. back). Some WEB pages contain a table paging feature that displays a
certain number of instances per page within a table. As the user cycles through the different
pages, he will be able to view different instances and the URL will be updated to save this
information. This allows a user to re-load the same view by using the URL (i.e. saving
bookmark, clicking back to reload page, etc.). However, when reloading a web page using
this method, incorrect index offsets may be observed for instances on certain pages.

ATRC-D13944 Generator RFC2544 in-service and monitor operate incorrectly


When an L2PT rule is enabled with forwarding mode set to either pop or replace and the
frame is S-VLAN tagged, the frame is dropped instead of being forwarded.

ATRC-D16848 Filter does not catch IPv6 Extension Headers


Because the frame header fields extraction depth is limited to the first 96 bytes of a frame,
any fields of an IPv6 frame that are beyond the first 96 bytes will not be extracted.
Therefore, they will not be found in the classification key used against an IPv6 filter.
Also, the following IPv6 Next Headers identifying Extension Headers will be skipped.
Therefore, they will not be found in the classification key used against an IPv6 filter:
• Hop-by-Hop options (0)
• Destination options (60)
• Routing header (43)
• Fragment header (44)
• Authentication header (51)
• Mobility header (135)

ATRC-D17233 SNMP IPv6 Filtering and Loopback is not supported


SNMP IPv6 Filtering and Loopback is not supported in this release.

ATRC-D15894 LBR message still occurring when MIP is created with MD level
Unicast CFM-LBM frames sent to Accedian Demarcation devices do not validate the MEG
level in the frame.

Revision 1 — August 2022 13


Release Notes Skylight element: GT Version 7.9.4

ATRC-D15523 DOWN MEP using VCE does not work with un-tag packet
We do not support EVC Client Interface for an untagged MEP on a VCE. We only support
untagged MEPs, if it is a Down MEP on a physical port of the VCE.

ATRC-D15473 The TP-Z-PCP-Mapping does not work properly


An Up MEP defined on the TP-Z port of a VCE, which is defined with frame-type ‘all-to-
one’, does not support the PCP mapping since it necessarily becomes untagged when
egressing TP-A. The PCP value used is then inherited from the CFM object when additional
components are in the transmission path.

ATRC-D15229 DownMEP_VCE: VCE is using TPID but it is affected by changing s-vlan mode
0x9100
The user needs to configure the S-VLAN ethertype located under General system settings,
prior to configuring any VCE or CFM elements. If the user changes this setting after
configuring other elements, they may see some display discrepancies.

ATRC-D07187 LAG Port remains DOWN with LACP, but UP with Link status
When using LACP, if the catchall L2PT rules are enabled, LACP frames will not be handled
correctly to allow LACP to operate correctly.
Workaround: Create LACP rules that also apply to the L2PT configuration.

ATRC-D05982 Limited availability of the OAM Loopback feature


The 802.3ah OAM loopback feature is not functional on the following platforms:
• Skylight element: GT
• Skylight element: GX
• Skylight element: LT
• Skylight element: LX

ATRC-D05907 Reserved value no longer allowed in a Y.1731 configuration


As of firmware version 6.4.2, VLAN ID 4095 is a reserved value and is no longer allowed in
Y.1731 configurations.
If VLAN 4095 was used in a previous firmware version, support in version 6.4.2 will be
maintained through a firmware upgrade. However, any MA/MEG instances using VLAN
4095 cannot be recreated in the event of a deletion.

Revision 1 — August 2022 14


Release Notes Skylight element: GT Version 7.9.4

ATRC-D05812 SNMP returns incorrect values for certain PAA configuration parameters
Polling the following PAA configuration OIDs with SNMP returns “0” instead of the actual
value:
• acdPaaUdpCfgOneWayDelayMax
• acdPaaUdpCfgOneWayDelayThresh
• acdPaaUdpCfgOneWayAvgDelayThresh
• acdPaaUdpCfgOperationMode
• acdPaaUdpCfgPktSize
• acdPaaUdpCfgSamplingPeriod
• acdPaaUdpCfgPeerID

ATRC-D05755 L2PT rules for ESMC also catch other slow protocols
An L2PT rule configured for the ESMC protocol may also catch the following protocol
frames:
• Link OAM
• LAMP
• LACP
If separate L2PT rules are not required for these protocols, no specific intervention is
necessary.
If separate L2PT rules are required for these protocols, assign a higher rule ID to ESMC to
ensure that it does not interfere with other protocols. As a result, other protocol filter rules
will be processed before the ESMC rule.

ATRC-D05720 VC Agent: Changing the local time can cause a disconnection from Vision EMS
Changing the local time on a unit can cause the Vision Collect agent to disconnect from
Vision EMS. The agent will reconnect automatically. No PM data is lost; if a transfer is
interrupted, the data will be retransferred once the connection is restored.

ATRC-D05446 Slight variation in BLUE queue full/empty threshold percentage values


The Web interface for the following products accepts values between 0 and 100 for the
BLUE Queue Full Threshold and BLUE Queue Empty Threshold parameters:
• Skylight element: GT
• Skylight element: GX
• Skylight element: LT
• Skylight element: LX

Revision 1 — August 2022 15


Release Notes Skylight element: GT Version 7.9.4

These values are expressed as percentages. However, this percentage value is


subsequently converted to a binary number and mapped to the range 0-128, as the
underlying register is 7 bits in length.
In most cases, the initial percentage will not correspond to an exact binary value. When this
value is then converted back to a decimal percentage for display purposes, the end result
may differ slightly from what was initially entered.

ATRC-D05432 History CSV files may not all contain the same range of period numbers
The exported history CSV files may not all contain the identical range of period numbers,
depending on when the given history metrics were collected. Enabling multiple categories
of history metrics with many instances requires more processing than history metrics with
fewer categories and instances. Since the history files are processed sequentially, some
exported files may consequently present different period numbers compared to others.
For example, the CFM DMM file may show periods 16-30, whereas the CFM SLM file may
show periods 17-31, since it was processed afterwards. The reason for this variation is that
new periods are included in the CSV file as soon as they become available.
This is the expected behavior. There is no period number synchronization between history
categories. Note that all periods are exported in the CSV files and no data is lost.

ATRC-D05382 CoS Mapping: Yellow PCP Out is not mapped to a queue


The following products use CoS mapping to define the internal CoS that service frames will
use in the unit.
• Skylight element: GT
• Skylight element: GX
• Skylight element: LT
• Skylight element: LX
However, the pre-marking color parameter (set to Green or Yellow) is disregarded when
mapping a flow to a traffic queue. The system’s internal CoS always uses the configured
Green PCP value to map a flow to a queue, regardless of whether the pre-marking is set to
Green or Yellow.

ATRC-D04263 Web Interface: VLAN ID value not properly validated when creating a VID set
The VLAN ID value is not properly validated when creating a VID set in the Web Interface.
Entries outside the valid range (0–4095) are accepted, as well as character strings; however,
the resulting VID set instance is empty with no VLAN ID assigned.
This issue only concerns the Web Interface; the CLI performs the proper validation and
rejects invalid entries as expected.
The following products and firmware versions are affected:

Revision 1 — August 2022 16


Release Notes Skylight element: GT Version 7.9.4

Product Name Firmware Versions

TE-x Performance Element 5.1 – 6.4.3

GT/GT-S Performance Element, now 6.3 – 7.3


Skylight element: GT/GT-S (7.9) 7.9.1

GT-Q/GT-QE Performance Element 7.1.1 – 7.3

GX/GX-S Performance Element, now 6.3 – 7.3


Skylight element: GX/GX-S (7.9) 7.9.1

10GE CE/NE Performance Element 5.0 – 6.3

LT/LT-S Performance Element, now 6.3 – 7.3


Skylight element: LT/LT-S (7.9) 7.9.1

Skylight element: LX-S 7.9.1

FS/FS 10G Performance Element 1.0 – 1.1

ATRC-D04040 Syslog error message at login after configuring RADIUS


After a first-time RADIUS configuration, a false syslog error may be generated due to start-
up conditions when the user logs in.
The syslog message is as follows:
Jan 1 00:19:13 C074-0010 dropbear[1620]: rc_get_seqnbr: fscanf
failure: /tmp/radius.seq
This message has no consequence and can be ignored.

ATRC-D03949 Modified syntax for CLI command “bandwidth-generator add”


Starting in firmware version 6.4, the CLI command bandwidth-generator add is used to
configure regulators and bandwidth sharing envelopes.
Previous syntax (before 6.4):
bandwidth-regulator add <regulator-name> …
New syntax (6.4 and later):
bandwidth-regulator add regulator <regulator-name> …
or
bandwidth-regulator add envelope <envelope-name> …

Revision 1 — August 2022 17


Release Notes Skylight element: GT Version 7.9.4

Consequently, the word regulator is reserved as of firmware version 6.4 and cannot be used
as a regulator name, although the former syntax is still supported for backward
compatibility.
These changes are illustrated in the following examples.
Preferred syntax:
bandwidth-regulator add regulator regulator1 cir 20000 …
Allowed (for backward compatibility):
bandwidth-regulator add regulator1 cir 20000 …
Not allowed (triggers an error message):
bandwidth-regulator add regulator cir 20000 …
(invalid parameter value)

ATRC-D03939 Maximum number of complex rules for ERP traffic


For any unit that supports G.8032, the system automatically creates a default Layer-2 filter
traffic policy (used for the ring pass-through traffic) whenever a LAG port is configured for
ERP.
Since this default policy consumes one of the unit’s available complex rules (i.e., using a
Layer-2 or IPv4 filters), the number of complex rules available to users on that LAG port is
reduced by 1. This situation has no impact on other ports.

ATRC-D02695 Timestamps of report periods are not always contiguous


The data collected by Vision EMS in high-resolution mode can occasionally show
consecutive records with timestamps that are not contiguous.
Be aware of the following limitations:
• When data is collected in high-resolution (1 second) mode, two consecutive
measurements can sometimes present the same timestamp, or show a gap
between the timestamps. This is caused by rounding the time value to a
granularity of 1 second.
Please note that in this case, no periods or measurements are lost, i.e. all periods
are consecutive, and none are missing.
• There can be a timestamp gap or overlap when the unit is first synchronized by
NTP, PTP or GPS. As the Flow meter may be acquiring data before the
synchronization is complete, a time adjustment could affect the timestamps. No
periods or measurements are lost.
Inconsistencies may also surface in the timestamps collected before a system reboot when
compared to those collected after the reboot.

Revision 1 — August 2022 18


Release Notes Skylight element: GT Version 7.9.4

ATRC-D02648 New behavior when re-enabling CFM-PL instances


In firmware version 6.3.1, the CFM packet loss (PL) behavior has been modified as follows:
Previous behavior (before 6.3.1): When a packet loss (PL) instance is re-enabled after being
disabled, the current period results contain the last values from the point at which the
instance was disabled.
New behavior (6.3.1. and later): When a packet loss (PL) instance is re-enabled after being
disabled, the current period results are cleared, and measurements begin from 0.

ATRC-D02057 Syslog: Entries are sometimes not displayed in the system log
When a large number of events occur at the same time (e.g. raising or clearing hundreds of
alarms simultaneously), some entries may be absent from the syslog. Missing entries do
not imply that the corresponding events/actions were not properly executed.
For example, in the case of alarm storms, although syslog messages for some status
changes are not displayed, all the alarms are updated to the correct status and the
corresponding SNMP traps are reported.

ATRC-7830 RFC-2544 testsuite: Report displays incorrect unit identifier information


When running the RFC-2544 testsuite after modifying the unit identifier (System ▶ DNS ▶
host name), the generated report contains the previous unit identifier.

ATRC-B10797 Firmware upgrade considerations pertaining to history buckets


Since firmware version 6.3.1, several software modifications have optimized how the
history data is handled and stored to flash memory. Before proceeding with the firmware
upgrade, take the following precautions:
• To prevent any loss of history data, ensure that all data has been transferred to
the file server.
• Be aware of certain side-effects caused by these optimizations on systems on
which the History Buckets feature is enabled.
Upgrading from any pre-6.3.1 version to 6.3.1. and later:

• All history data present on the flash memory is deleted during the upgrade
process.
Upgrading from version 6.3.1 to 6.4.2:

• No history data is deleted during the upgrade process.


Upgrading from version 6.3.1 or 6.4.2 to any later version:

• All history data present on the flash memory is deleted during the upgrade
process.
Upgrading from version 6.4.2.1 to 7.0:

Revision 1 — August 2022 19


Release Notes Skylight element: GT Version 7.9.4

• All history data present on the flash memory for the Policy, Regulator, Shaper,
SOAM DMM and SOAM PL is deleted during the upgrade process.
Upgrading from version 6.4.2.1 to 7.2:

• All history data present on the flash memory for the Policy, Regulator, Shaper,
SOAM DMM and SOAM PL is deleted during the upgrade process.

ATRC-7572 Y.1564 one-way flows must be received on the same SAT server port
If one-way test flows from multiple Y.1564 generators are sent to a SAT server (i.e. a remote
unit), all flows must terminate on the same physical port. For example, terminating eight
flows on one port and eight other flows on a different port is not supported.

ATRC-7028 No VLAN information in LLDP frames


LLDP frames sent by the unit only contain the interfaces’ IP address and index values.
Information on the interfaces’ VLAN settings is not available at this time.

ATRC-6906 RFC-2544 monitors are not independent


When using both RFC-2544 monitors in bypass mode to monitor Layer-2 and Layer-3 test
traffic flows, both monitors will report the Layer-3 flow statistics. If the monitor configured
for Layer-2 is disabled, the other monitor (Layer-3) does not report any statistics.

ATRC-6869 Obtaining the UTC offset from the PTP master is not supported
The option to obtain the UTC offset from the PTP master is not yet supported. As such, the
offset provided in the announce messages from the PTP master are not applied to the time
information on the unit. Only the locally defined UTC offset can be used.

ATRC-6846 IPv6 router-advertised addresses are lost when configuring other addresses
After an interface has configured itself with one or several addresses from IPv6 router
advertisements, configuring any other address (whether static or DHCP) will flush the
router-advertised addresses.
This is the intended implementation, since configuring a static IP or enabling DHCP
supersedes the router advertisements.

ATRC-6758 Higher number of Y.1731 frames sent over a period


The number of Y.1731 sample frames (CCM, DMM or SLM) sent over a period can be slightly
higher than expected.
For example, if SLM is configured with an interval of 100 ms and a period of 60 seconds, it
is possible that 601 or 602 samples will be sent during the period instead of 600. This is
caused by a rounding issue related to timer division.

Revision 1 — August 2022 20


Release Notes Skylight element: GT Version 7.9.4

This issue does not lead to packet loss or inaccurate delay results; it is merely a variation of
the number of samples sent over a period.

ATRC-6672 Plug & Go ring protection from customer beacon


When a new unit is added to a G.8032 ERP ring and is in the process of being provisioned
using the Plug & Go feature, it is important to ensure that no foreign beacons enter the ring
from the UNI side (e.g. from a customer). Taking this measure prevents the new ring unit
from being provisioned by the wrong beacon.

ATRC-6604 Web interface may be slow with Mozilla Firefox version 14.0.1 to 22
When using the Mozilla Firefox Web browser version 14.0.1 to 22 to manage the unit, the
response time can sometimes increase, which makes the Web interface slow to operate.
Workaround: Use Firefox version 23 or higher.

ATRC-6509 LAG-Protection: ETH-CSF cannot validate port state on LACP-based UNI links
If enabled, ETH-CSF cannot validate the link status of an LACP-based protected UNI link.
Under such circumstances, the remote fault cannot be propagated. Since ETH-CSF is based
on link-status and LACP is based on signaling, it is currently impossible to indicate to CSF
that the link is logically down, yet still physically up.

ATRC-6425 CLI traceroute command does not support all listed options
The CLI traceroute command does not support the following options:
• -q (number of queries)
• -s (source IP address)
• -g (gateway)

ATRC-6132 VSP reflector responds to invalid MAC addresses on the management port
The V-NID reflector functionality is only intended for use on traffic ports, not on out-of-
band management ports. However, the out-of-band management port will reflect any
ETH-VSP frames it receives. While traffic ports only reflect VSP frames that match the
port’s specific MAC address, the out-of-band management port will reflect VSP frames that
match the MAC address belonging to any of the unit’s ports (MAC range).

ATRC-5790 EVC Mapping: “Preserve VLAN - New CFI/PCP” limitations


When setting EVC Mapping to “Preserve VLAN - New CFI/PCP”, the following limitations
should be taken into consideration:
• DSCP/IP Precedence information is not extracted from triple-tagged frames.
• DSCP/ IP Precedence information is not extracted from 802.2 SNAP/LLC frames.

Revision 1 — August 2022 21


Release Notes Skylight element: GT Version 7.9.4

• DSCP/ IP Precedence/PCP information is not extracted from S-VLAN (0x9100)


tagged frames, unless 0x9100 is set globally as the default S-VLAN Ethertype.
This EVC mapping action can corrupt untagged frames. Therefore, a filter matching at least
one VLAN must be used to ensure the classified frames are tagged.

ATRC-5646 EVC mapping actions that modify VLAN tags must not be used with untagged
traffic
EVC mapping actions that involve replacing or modifying a VLAN tag should not be used if
the traffic is untagged. These EVC mapping actions are:
• Replace
• Pop & Replace
• Preserve VLAN – New CFI/PCP
Performing VLAN modifications on untagged traffic could result in altering the frames.
There is no traffic policy validation to enforce the presence of a VLAN filter with these EVC
mapping actions. You must therefore ensure that any policy using these EVC mapping
actions is configured with a VLAN filter.

ATRC-5474 Frame count statistics may be inconsistent if SLM is disabled in mid-period


If an SLM instance is disabled in the middle of a reference period, the ETH-SLM and
ETH-SLR frame counts shown in the MEP statistics may not be consistent with those
shown in the SLM statistics. This is normal, as the information may not have been refreshed
at the very moment when the SLM instance was disabled.
This behavior is a normal consequence of disabling the SLM instance during a period and is
by design. SLM functions as expected in continuous operation.

ATRC-5364 CPU-destined ingress traffic can be processed on an LACP link while not in the
collecting/distributing state
When using LACP status-based protection, CPU-destined traffic received on a port can be
processed by the software even when the local (actor) LACP link status is not in the
collecting/distributing state. This situation applies to CFM traffic (LBM, LTM, DMM, CCM,
etc.), PAA traffic and L2PT traffic.

ATRC-5254 Web session does not time out if automatic refresh is enabled
The active session of the Web interface will never time out if automatic refresh is enabled
in a page.

ATRC-5197 ARP Requests are sent out on a port when interface is disabled
Many ARP requests are sent out on a port even if the interface associated with the port is
disabled.

Revision 1 — August 2022 22


Release Notes Skylight element: GT Version 7.9.4

ATRC-5196 “cfm show statistics” CLI command shows incorrect RDI and CCM sequence errors
This CLI command does not accurately report the count of CCM sequence errors. This
information can be displayed using the cfm show mep statistics command.

ATRC-5107 Users without “Policy” permissions can clear policy statistics in the Web interface
Users are currently able to clear the Policy statistics in the Web interface (but not in the
CLI), regardless of their assigned permission settings.

ATRC-4560 CLI: CFM naming convention (MEP, Pkt-loss, DMM)


When assigning a CFM name to an instance in the GUI, the name must not be composed
solely of digits; CFM names must always include at least one letter. If the name contains
only digits, the CLI interprets the name as an instance index.

ATRC-4076 SCP -z option not working with certain servers


Certain SSH servers, such as Solaris and several Linux enterprise versions, do not support
the SCP -z option to specify the username. Once the SCP fails, FTP no longer functions since
it uses the same process. The CPU must be restarted for FTP to function.
This issue is related to how the SSHd server is configured. Servers are usually configured to
use PAM (Pluggable Authentication Modules) for account and session management. SSHd
can also rely on PAM for authentication; PAM then executes its authentication scheme
based on its configuration for that login method (for example: /etc/pam.d/sshd).
Configuring Response Authentication:
• With OpenSSH, ChallengeResponseAuthentication in /etc/ssh/sshd_config should
be set to No.
• On Solaris, PAMAuthenticationViaKBDInt in /etc/sshd_config should be set to No.
Alternate Solutions:
• Change the PAM configuration for SSHd (expert).
• Use a public key authentication.
Modification Procedure:
• Solaris:
o Log in with administrative privileges.
o Edit file /etc/ssh/sshd_config to set PAMAuthenticationViaKBDInt to No.
o Save file and exit.
o Restart service: svcadm restart network/ssh.
• Ubuntu Linux (OpenSSH):
o Log in with administrative privileges.
o Edit file /etc/ssh/sshd_config to set ChallengeResponseAuthentication to No.

Revision 1 — August 2022 23


Release Notes Skylight element: GT Version 7.9.4

o Save file and exit.


o Restart service: sudo service ssh restart.

ATRC-3533 SyncE is not supported with copper SFP


Copper SFPs use the internal 25 MHz oscillator instead of the SyncE recovered clock.
Consequently, SyncE is not supported for copper SFPs.

ATRC-3285 Web browser refresh deletes the current search filter


Using the browser Refresh command (F5 or Ctrl+R) does not only refresh the page values,
it also reloads the page completely. Doing so eliminates any search filters that were entered.
This behavior is considered normal.

3.4 MIB Changes


None

Revision 1 — August 2022 24


Release Notes Skylight element: GT Version 7.9.4

4. Firmware Version 7.9.3_24427 (2021-12-15)

4.1 New Features and Enhancements

AC-22907 SW Watchdog Enhancement


Enhancements to watchdog software to monitor additional functionalities that could block or
impact normal operation. Added robustness in case such errors occur that will restart the
device and avoid having to send a technician on site.

AC-22977 Elements: TACACS+CHAP and ASCII


TACACS+ now supports ASCII and CHAP authentication methods.
The user will have to modify the user interfaces (CLI/WEB) to support this new
authentication method. And The TACACS+ is used for user authentication purposes only in
Accedian platforms.

AC-23039 Accedian MIBs Include Flex 100 sub OIDs


Enhancements to include Flex 100 sub OIDs in Accedian MIBs.

AC-23037 Web help removed from firmware deliveries


The web help is no longer available through the user interface and has been added to the
new documentation platform: docs.accedian.io. This new platform is searchable and
provides access to all web help as of release 7.9.3. Previous versions can be located within
older firmware or on salesforce.

Revision 1 — August 2022 25


Release Notes Skylight element: GT Version 7.9.4

4.2 Addressed Issues

AC-23593 Need to remove the fake IP address configuration on layer-2 interface for PTP-BC
This fake IP was unnecessary and lead to confusion. Need to remove the IP address.
This issue has been fixed.

AC-22274 Devices using standby and rebooting


It was observed that on rare occasion, a reboot of the unit would revert to the alternate
software bank using the current configuration, inducing a non-supported backward
configuration migration that might impact the unit operation, including radius
authentication and/or all traffic being down.
This issue has been fixed.

AC-22137 Reboot after rollback version was loaded with the current configuration
Performance element using the back up firmware after a reboot had a database mismatch
after loading current configuration.
This issue has been fixed.

AC-22134 LAG status automatically enabled after NID reboot


When Port LAG-1 and LAG-2 on GTS NID was disabled after NID reboot, both LAG ports
were enabled automatically.
This issue has been fixed.

AC-22046 Y.1564 Generator rate layer-2 test duration performing shorter than expected
testing period
When running the Y1564 test suite with layer 2 rate Performance test duration:1440
minutes, the test was 44 minutes short from the 24h full period it was supposed to test.
This issue has been fixed.

AC-21989 Loss shaping queues and profiles (ERP)


Unable to default select queuing profile in policy configuration during deployment and all
queues were lost.
This issue has been fixed.

Revision 1 — August 2022 26


Release Notes Skylight element: GT Version 7.9.4

4.3 Operational Considerations and Known Limitations


Important Notes

 The Skylight element: LX firmware is delivered in a consolidated file prefixed by “ACC”,


e.g. ACC_7.X_YYYY.afl. This file contains the firmware for the GT, GX , LX and LT
Performance Element products. It cannot be used with any other product.
 IMPORTANT: Prior to upgrading the firmware on a unit where the History Buckets
feature is enabled, certain precautions may need to be taken to prevent a loss of history
data during the upgrade. Refer to ATRC-B10797 for details.
 In a G.8032 ring configuration, the Skylight element: LX supports a maximum of 62
policies on the LAG port (i.e. policies that govern how traffic is dropped from the ring to
UNI ports). This limitation does not apply to the UNI ports (i.e. policies that govern how
traffic is added to the ring) unless the VLAN-tagged customer traffic is passed
transparently from the UNI port to the ring through one-to-one mapping.
One way to avoid this limitation and maximize the number of usable UNI policies is to
encapsulate multiple customer VLANs (coming from the UNI) under a single service
provider VLAN on the ring. Doing so reduces the number of policies required by the LAG
port.

AC-22752 TWAMP Sync issue when reflector is an Accedian device with 6.4.x software or
older
A sync compatibility with older software will cause a sync error when generating
TWAMP towards a device using older software (ex: TE device). The impact is the absence
of one-way delay measurement. There is no workaround available for this issue.

ATRC-D15900 LBR message still occurs when MIP and MEP are different VLAN type
Unicast CFM-LBM frames sent to Accedian Demarcation devices are VLAN TPID unaware.

ATRC-D17907 Missing packets on RFC2544 generator layer-3 (2 flows)


With an RFC2544 generator layer-3 that has flow 1 set as QinQ and flow 2 set as no
encapsulation (or QinQ), packets are missing on flow 2 after completing the RFC2544 with
two flows.

ATRC-D17871 Error loading proper page indexing when loading pages via URL/back
Possible error loading proper page indexing when loading WEB pages that contain paged
tables via URL (i.e. back). Some WEB pages contain a table paging feature that displays a
certain number of instances per page within a table. As the user cycles through the different

Revision 1 — August 2022 27


Release Notes Skylight element: GT Version 7.9.4

pages, he will be able to view different instances and the URL will be updated to save this
information. This allows a user to re-load the same view by using the URL (i.e. saving
bookmark, clicking back to reload page, etc.). However, when reloading a web page using
this method, incorrect index offsets may be observed for instances on certain pages.

ATRC-D13944 Generator RFC2544 in-service and monitor operate incorrectly


When an L2PT rule is enabled with forwarding mode set to either pop or replace and the
frame is S-VLAN tagged, the frame is dropped instead of being forwarded.

ATRC-D16848 Filter does not catch IPv6 Extension Headers


Because the frame header fields extraction depth is limited to the first 96 bytes of a frame,
any fields of an IPv6 frame that are beyond the first 96 bytes will not be extracted.
Therefore, they will not be found in the classification key used against an IPv6 filter.
Also, the following IPv6 Next Headers identifying Extension Headers will be skipped.
Therefore, they will not be found in the classification key used against an IPv6 filter:
• Hop-by-Hop options (0)
• Destination options (60)
• Routing header (43)
• Fragment header (44)
• Authentication header (51)
• Mobility header (135)

ATRC-D17233 SNMP IPv6 Filtering and Loopback is not supported


SNMP IPv6 Filtering and Loopback is not supported in this release.

ATRC-D15894 LBR message still occurring when MIP is created with MD level
Unicast CFM-LBM frames sent to Accedian Demarcation devices do not validate the MEG
level in the frame.

ATRC-D15523 DOWN MEP using VCE does not work with un-tag packet
We do not support EVC Client Interface for an untagged MEP on a VCE. We only support
untagged MEPs, if it is a Down MEP on a physical port of the VCE.

ATRC-D15473 The TP-Z-PCP-Mapping does not work properly


An Up MEP defined on the TP-Z port of a VCE, which is defined with frame-type ‘all-to-
one’, does not support the PCP mapping since it necessarily becomes untagged when

Revision 1 — August 2022 28


Release Notes Skylight element: GT Version 7.9.4

egressing TP-A. The PCP value used is then inherited from the CFM object when additional
components are in the transmission path.

ATRC-D15229 DownMEP_VCE: VCE is using TPID but it is affected by changing s-vlan mode
0x9100
The user needs to configure the S-VLAN ethertype located under General system settings,
prior to configuring any VCE or CFM elements. If the user changes this setting after
configuring other elements, they may see some display discrepancies.

ATRC-D07187 LAG Port remains DOWN with LACP, but UP with Link status
When using LACP, if the catchall L2PT rules are enabled, LACP frames will not be handled
correctly to allow LACP to operate correctly.
Workaround: Create LACP rules that also apply to the L2PT configuration.

ATRC-D05982 Limited availability of the OAM Loopback feature


The 802.3ah OAM loopback feature is not functional on the following platforms:
• Skylight element: GT
• Skylight element: GX
• Skylight element: LT
• Skylight element: LX

ATRC-D05907 Reserved value no longer allowed in a Y.1731 configuration


As of firmware version 6.4.2, VLAN ID 4095 is a reserved value and is no longer allowed in
Y.1731 configurations.
If VLAN 4095 was used in a previous firmware version, support in version 6.4.2 will be
maintained through a firmware upgrade. However, any MA/MEG instances using VLAN
4095 cannot be recreated in the event of a deletion.

ATRC-D05812 SNMP returns incorrect values for certain PAA configuration parameters
Polling the following PAA configuration OIDs with SNMP returns “0” instead of the actual
value:
• acdPaaUdpCfgOneWayDelayMax
• acdPaaUdpCfgOneWayDelayThresh
• acdPaaUdpCfgOneWayAvgDelayThresh
• acdPaaUdpCfgOperationMode
• acdPaaUdpCfgPktSize

Revision 1 — August 2022 29


Release Notes Skylight element: GT Version 7.9.4

• acdPaaUdpCfgSamplingPeriod
• acdPaaUdpCfgPeerID

ATRC-D05755 L2PT rules for ESMC also catch other slow protocols
An L2PT rule configured for the ESMC protocol may also catch the following protocol
frames:
• Link OAM
• LAMP
• LACP
If separate L2PT rules are not required for these protocols, no specific intervention is
necessary.
If separate L2PT rules are required for these protocols, assign a higher rule ID to ESMC to
ensure that it does not interfere with other protocols. As a result, other protocol filter rules
will be processed before the ESMC rule.

ATRC-D05720 VC Agent: Changing the local time can cause a disconnection from Vision EMS
Changing the local time on a unit can cause the Vision Collect agent to disconnect from
Vision EMS. The agent will reconnect automatically. No PM data is lost; if a transfer is
interrupted, the data will be retransferred once the connection is restored.

ATRC-D05446 Slight variation in BLUE queue full/empty threshold percentage values


The Web interface for the following products accepts values between 0 and 100 for the
BLUE Queue Full Threshold and BLUE Queue Empty Threshold parameters:
• Skylight element: GT
• Skylight element: GX
• Skylight element: LT
• Skylight element: LX
These values are expressed as percentages. However, this percentage value is
subsequently converted to a binary number and mapped to the range 0-128, as the
underlying register is 7 bits in length.
In most cases, the initial percentage will not correspond to an exact binary value. When this
value is then converted back to a decimal percentage for display purposes, the end result
may differ slightly from what was initially entered.

ATRC-D05432 History CSV files may not all contain the same range of period numbers
The exported history CSV files may not all contain the identical range of period numbers,
depending on when the given history metrics were collected. Enabling multiple categories
of history metrics with many instances requires more processing than history metrics with

Revision 1 — August 2022 30


Release Notes Skylight element: GT Version 7.9.4

fewer categories and instances. Since the history files are processed sequentially, some
exported files may consequently present different period numbers compared to others.
For example, the CFM DMM file may show periods 16-30, whereas the CFM SLM file may
show periods 17-31, since it was processed afterwards. The reason for this variation is that
new periods are included in the CSV file as soon as they become available.
This is the expected behavior. There is no period number synchronization between history
categories. Note that all periods are exported in the CSV files and no data is lost.

ATRC-D05382 CoS Mapping: Yellow PCP Out is not mapped to a queue


The following products use CoS mapping to define the internal CoS that service frames will
use in the unit.
• Skylight element: GT
• Skylight element: GX
• Skylight element: LT
• Skylight element: LX
However, the pre-marking color parameter (set to Green or Yellow) is disregarded when
mapping a flow to a traffic queue. The system’s internal CoS always uses the configured
Green PCP value to map a flow to a queue, regardless of whether the pre-marking is set to
Green or Yellow.

ATRC-D04263 Web Interface: VLAN ID value not properly validated when creating a VID set
The VLAN ID value is not properly validated when creating a VID set in the Web Interface.
Entries outside the valid range (0–4095) are accepted, as well as character strings; however,
the resulting VID set instance is empty with no VLAN ID assigned.
This issue only concerns the Web Interface; the CLI performs the proper validation and
rejects invalid entries as expected.
The following products and firmware versions are affected:

Product Name Firmware Versions

TE-x Performance Element 5.1 – 6.4.3

GT/GT-S Performance Element, now 6.3 – 7.3


Skylight element: GT/GT-S (7.9) 7.9.1

GT-Q/GT-QE Performance Element 7.1.1 – 7.3

GX/GX-S Performance Element, now 6.3 – 7.3


Skylight element: GX/GX-S (7.9) 7.9.1

10GE CE/NE Performance Element 5.0 – 6.3

Revision 1 — August 2022 31


Release Notes Skylight element: GT Version 7.9.4

Product Name Firmware Versions

LT/LT-S Performance Element, now 6.3 – 7.3


Skylight element: LT/LT-S (7.9) 7.9.1

Skylight element: LX-S 7.9.1

FS/FS 10G Performance Element 1.0 – 1.1

ATRC-D04040 Syslog error message at login after configuring RADIUS


After a first-time RADIUS configuration, a false syslog error may be generated due to start-
up conditions when the user logs in.
The syslog message is as follows:
Jan 1 00:19:13 C074-0010 dropbear[1620]: rc_get_seqnbr: fscanf
failure: /tmp/radius.seq
This message has no consequence and can be ignored.

ATRC-D03949 Modified syntax for CLI command “bandwidth-generator add”


Starting in firmware version 6.4, the CLI command bandwidth-generator add is used to
configure regulators and bandwidth sharing envelopes.
Previous syntax (before 6.4):
bandwidth-regulator add <regulator-name> …
New syntax (6.4 and later):
bandwidth-regulator add regulator <regulator-name> …
or
bandwidth-regulator add envelope <envelope-name> …
Consequently, the word regulator is reserved as of firmware version 6.4 and cannot be used
as a regulator name, although the former syntax is still supported for backward
compatibility.
These changes are illustrated in the following examples.
Preferred syntax:
bandwidth-regulator add regulator regulator1 cir 20000 …
Allowed (for backward compatibility):
bandwidth-regulator add regulator1 cir 20000 …
Not allowed (triggers an error message):
bandwidth-regulator add regulator cir 20000 …
(invalid parameter value)

Revision 1 — August 2022 32


Release Notes Skylight element: GT Version 7.9.4

ATRC-D03939 Maximum number of complex rules for ERP traffic


For any unit that supports G.8032, the system automatically creates a default Layer-2 filter
traffic policy (used for the ring pass-through traffic) whenever a LAG port is configured for
ERP.
Since this default policy consumes one of the unit’s available complex rules (i.e., using a
Layer-2 or IPv4 filters), the number of complex rules available to users on that LAG port is
reduced by 1. This situation has no impact on other ports.

ATRC-D02695 Timestamps of report periods are not always contiguous


The data collected by Vision EMS in high-resolution mode can occasionally show
consecutive records with timestamps that are not contiguous.
Be aware of the following limitations:
• When data is collected in high-resolution (1 second) mode, two consecutive
measurements can sometimes present the same timestamp, or show a gap
between the timestamps. This is caused by rounding the time value to a
granularity of 1 second.
Please note that in this case, no periods or measurements are lost, i.e. all periods
are consecutive, and none are missing.
• There can be a timestamp gap or overlap when the unit is first synchronized by
NTP, PTP or GPS. As the Flow meter may be acquiring data before the
synchronization is complete, a time adjustment could affect the timestamps. No
periods or measurements are lost.
Inconsistencies may also surface in the timestamps collected before a system reboot when
compared to those collected after the reboot.

ATRC-D02648 New behavior when re-enabling CFM-PL instances


In firmware version 6.3.1, the CFM packet loss (PL) behavior has been modified as follows:
Previous behavior (before 6.3.1): When a packet loss (PL) instance is re-enabled after being
disabled, the current period results contain the last values from the point at which the
instance was disabled.
New behavior (6.3.1. and later): When a packet loss (PL) instance is re-enabled after being
disabled, the current period results are cleared, and measurements begin from 0.

ATRC-D02057 Syslog: Entries are sometimes not displayed in the system log
When a large number of events occur at the same time (e.g. raising or clearing hundreds of
alarms simultaneously), some entries may be absent from the syslog. Missing entries do
not imply that the corresponding events/actions were not properly executed.
For example, in the case of alarm storms, although syslog messages for some status
changes are not displayed, all the alarms are updated to the correct status and the
corresponding SNMP traps are reported.

Revision 1 — August 2022 33


Release Notes Skylight element: GT Version 7.9.4

ATRC-7830 RFC-2544 testsuite: Report displays incorrect unit identifier information


When running the RFC-2544 testsuite after modifying the unit identifier (System ▶ DNS ▶
host name), the generated report contains the previous unit identifier.

ATRC-B10797 Firmware upgrade considerations pertaining to history buckets


Since firmware version 6.3.1, several software modifications have optimized how the
history data is handled and stored to flash memory. Before proceeding with the firmware
upgrade, take the following precautions:
• To prevent any loss of history data, ensure that all data has been transferred to
the file server.
• Be aware of certain side-effects caused by these optimizations on systems on
which the History Buckets feature is enabled.
Upgrading from any pre-6.3.1 version to 6.3.1. and later:

• All history data present on the flash memory is deleted during the upgrade
process.
Upgrading from version 6.3.1 to 6.4.2:

• No history data is deleted during the upgrade process.


Upgrading from version 6.3.1 or 6.4.2 to any later version:

• All history data present on the flash memory is deleted during the upgrade
process.
Upgrading from version 6.4.2.1 to 7.0:

• All history data present on the flash memory for the Policy, Regulator, Shaper,
SOAM DMM and SOAM PL is deleted during the upgrade process.
Upgrading from version 6.4.2.1 to 7.2:

• All history data present on the flash memory for the Policy, Regulator, Shaper,
SOAM DMM and SOAM PL is deleted during the upgrade process.

ATRC-7572 Y.1564 one-way flows must be received on the same SAT server port
If one-way test flows from multiple Y.1564 generators are sent to a SAT server (i.e. a remote
unit), all flows must terminate on the same physical port. For example, terminating eight
flows on one port and eight other flows on a different port is not supported.

ATRC-7028 No VLAN information in LLDP frames


LLDP frames sent by the unit only contain the interfaces’ IP address and index values.
Information on the interfaces’ VLAN settings is not available at this time.

Revision 1 — August 2022 34


Release Notes Skylight element: GT Version 7.9.4

ATRC-6906 RFC-2544 monitors are not independent


When using both RFC-2544 monitors in bypass mode to monitor Layer-2 and Layer-3 test
traffic flows, both monitors will report the Layer-3 flow statistics. If the monitor configured
for Layer-2 is disabled, the other monitor (Layer-3) does not report any statistics.

ATRC-6869 Obtaining the UTC offset from the PTP master is not supported
The option to obtain the UTC offset from the PTP master is not yet supported. As such, the
offset provided in the announce messages from the PTP master are not applied to the time
information on the unit. Only the locally defined UTC offset can be used.

ATRC-6846 IPv6 router-advertised addresses are lost when configuring other addresses
After an interface has configured itself with one or several addresses from IPv6 router
advertisements, configuring any other address (whether static or DHCP) will flush the
router-advertised addresses.
This is the intended implementation, since configuring a static IP or enabling DHCP
supersedes the router advertisements.

ATRC-6758 Higher number of Y.1731 frames sent over a period


The number of Y.1731 sample frames (CCM, DMM or SLM) sent over a period can be slightly
higher than expected.
For example, if SLM is configured with an interval of 100 ms and a period of 60 seconds, it
is possible that 601 or 602 samples will be sent during the period instead of 600. This is
caused by a rounding issue related to timer division.
This issue does not lead to packet loss or inaccurate delay results; it is merely a variation of
the number of samples sent over a period.

ATRC-6672 Plug & Go ring protection from customer beacon


When a new unit is added to a G.8032 ERP ring and is in the process of being provisioned
using the Plug & Go feature, it is important to ensure that no foreign beacons enter the ring
from the UNI side (e.g. from a customer). Taking this measure prevents the new ring unit
from being provisioned by the wrong beacon.

ATRC-6604 Web interface may be slow with Mozilla Firefox version 14.0.1 to 22
When using the Mozilla Firefox Web browser version 14.0.1 to 22 to manage the unit, the
response time can sometimes increase, which makes the Web interface slow to operate.
Workaround: Use Firefox version 23 or higher.

Revision 1 — August 2022 35


Release Notes Skylight element: GT Version 7.9.4

ATRC-6509 LAG-Protection: ETH-CSF cannot validate port state on LACP-based UNI links
If enabled, ETH-CSF cannot validate the link status of an LACP-based protected UNI link.
Under such circumstances, the remote fault cannot be propagated. Since ETH-CSF is based
on link-status and LACP is based on signaling, it is currently impossible to indicate to CSF
that the link is logically down, yet still physically up.

ATRC-6425 CLI traceroute command does not support all listed options
The CLI traceroute command does not support the following options:
• -q (number of queries)
• -s (source IP address)
• -g (gateway)

ATRC-6132 VSP reflector responds to invalid MAC addresses on the management port
The V-NID reflector functionality is only intended for use on traffic ports, not on out-of-
band management ports. However, the out-of-band management port will reflect any
ETH-VSP frames it receives. While traffic ports only reflect VSP frames that match the
port’s specific MAC address, the out-of-band management port will reflect VSP frames that
match the MAC address belonging to any of the unit’s ports (MAC range).

ATRC-5790 EVC Mapping: “Preserve VLAN - New CFI/PCP” limitations


When setting EVC Mapping to “Preserve VLAN - New CFI/PCP”, the following limitations
should be taken into consideration:
• DSCP/IP Precedence information is not extracted from triple-tagged frames.
• DSCP/ IP Precedence information is not extracted from 802.2 SNAP/LLC frames.
• DSCP/ IP Precedence/PCP information is not extracted from S-VLAN (0x9100)
tagged frames, unless 0x9100 is set globally as the default S-VLAN Ethertype.
This EVC mapping action can corrupt untagged frames. Therefore, a filter matching at least
one VLAN must be used to ensure the classified frames are tagged.

ATRC-5646 EVC mapping actions that modify VLAN tags must not be used with untagged
traffic
EVC mapping actions that involve replacing or modifying a VLAN tag should not be used if
the traffic is untagged. These EVC mapping actions are:
• Replace
• Pop & Replace
• Preserve VLAN – New CFI/PCP
Performing VLAN modifications on untagged traffic could result in altering the frames.
There is no traffic policy validation to enforce the presence of a VLAN filter with these EVC

Revision 1 — August 2022 36


Release Notes Skylight element: GT Version 7.9.4

mapping actions. You must therefore ensure that any policy using these EVC mapping
actions is configured with a VLAN filter.

ATRC-5474 Frame count statistics may be inconsistent if SLM is disabled in mid-period


If an SLM instance is disabled in the middle of a reference period, the ETH-SLM and
ETH-SLR frame counts shown in the MEP statistics may not be consistent with those
shown in the SLM statistics. This is normal, as the information may not have been refreshed
at the very moment when the SLM instance was disabled.
This behavior is a normal consequence of disabling the SLM instance during a period and is
by design. SLM functions as expected in continuous operation.

ATRC-5364 CPU-destined ingress traffic can be processed on an LACP link while not in the
collecting/distributing state
When using LACP status-based protection, CPU-destined traffic received on a port can be
processed by the software even when the local (actor) LACP link status is not in the
collecting/distributing state. This situation applies to CFM traffic (LBM, LTM, DMM, CCM,
etc.), PAA traffic and L2PT traffic.

ATRC-5254 Web session does not time out if automatic refresh is enabled
The active session of the Web interface will never time out if automatic refresh is enabled
in a page.

ATRC-5197 ARP Requests are sent out on a port when interface is disabled
Many ARP requests are sent out on a port even if the interface associated with the port is
disabled.

ATRC-5196 “cfm show statistics” CLI command shows incorrect RDI and CCM sequence errors
This CLI command does not accurately report the count of CCM sequence errors. This
information can be displayed using the cfm show mep statistics command.

ATRC-5107 Users without “Policy” permissions can clear policy statistics in the Web interface
Users are currently able to clear the Policy statistics in the Web interface (but not in the
CLI), regardless of their assigned permission settings.

ATRC-4560 CLI: CFM naming convention (MEP, Pkt-loss, DMM)


When assigning a CFM name to an instance in the GUI, the name must not be composed
solely of digits; CFM names must always include at least one letter. If the name contains
only digits, the CLI interprets the name as an instance index.

Revision 1 — August 2022 37


Release Notes Skylight element: GT Version 7.9.4

ATRC-4076 SCP -z option not working with certain servers


Certain SSH servers, such as Solaris and several Linux enterprise versions, do not support
the SCP -z option to specify the username. Once the SCP fails, FTP no longer functions since
it uses the same process. The CPU must be restarted for FTP to function.
This issue is related to how the SSHd server is configured. Servers are usually configured to
use PAM (Pluggable Authentication Modules) for account and session management. SSHd
can also rely on PAM for authentication; PAM then executes its authentication scheme
based on its configuration for that login method (for example: /etc/pam.d/sshd).
Configuring Response Authentication:
• With OpenSSH, ChallengeResponseAuthentication in /etc/ssh/sshd_config should
be set to No.
• On Solaris, PAMAuthenticationViaKBDInt in /etc/sshd_config should be set to No.
Alternate Solutions:
• Change the PAM configuration for SSHd (expert).
• Use a public key authentication.
Modification Procedure:
• Solaris:
o Log in with administrative privileges.
o Edit file /etc/ssh/sshd_config to set PAMAuthenticationViaKBDInt to No.
o Save file and exit.
o Restart service: svcadm restart network/ssh.
• Ubuntu Linux (OpenSSH):
o Log in with administrative privileges.
o Edit file /etc/ssh/sshd_config to set ChallengeResponseAuthentication to No.
o Save file and exit.
o Restart service: sudo service ssh restart.

ATRC-3533 SyncE is not supported with copper SFP


Copper SFPs use the internal 25 MHz oscillator instead of the SyncE recovered clock.
Consequently, SyncE is not supported for copper SFPs.

ATRC-3285 Web browser refresh deletes the current search filter


Using the browser Refresh command (F5 or Ctrl+R) does not only refresh the page values,
it also reloads the page completely. Doing so eliminates any search filters that were entered.
This behavior is considered normal.

Revision 1 — August 2022 38


Release Notes Skylight element: GT Version 7.9.4

4.4 MIB Changes


None

Revision 1 — August 2022 39


Release Notes Skylight element: GT Version 7.9.4

5. Firmware Version 7.9.2_24262 (2021-09-24)

5.1 New Features and Enhancements

AC-20406 Enhanced Software Behavior in Detecting 1000B-T SFP Speed


A generic SFP detection mechanism for all Copper SFPs has been implemented to avoid the
exception list method and to complement the existing SFP speed override function
implemented for fiber SFP.
It is recommended to use the SFP Speed Override feature to configure the port speed for
Fiber SFPs and Copper SFPs. When the port speed/rate is overridden, the configured value
will be persistent

AC-20881 Update OpenSSL Library


The new OpenSSL requires the CURL library version 7.73, which has a major impact to
dealing with IPv6 addresses. The following details have been impacted:
• CURL 7.37: The [] style is not a MUST. A warning will pop up.
• CURL 7.73: The [] style as expressed in [RFC3986] must be used. An invalid url error
message will pop up and action is canceled.
The following has also been introduced to the new OpenSSL Library:
• TLSv1.3 (new compared to 1.0.2o):
o TLS_AES_256_GCM_SHA384
o TLS_CHACHA20_POLY1305_SHA256
o TLS_AES_128_GCM_SHA256
o TLS_AES_128_CCM_8_SHA256
o TLS_AES_128_CCM_SHA256
TLSv1.3 includes major changes and for this reason, some things may work very
differently. A brief, incomplete, summary of some things that you are likely to notice
follows:
• There are new ciphersuites that only work in TLSv1.3. The old ciphersuites cannot be
used for TLSv1.3 connections.
• The new ciphersuites are defined differently and do not specify the certificate type
(e.g. RSA, DSA, ECDSA) or the key exchange mechanism (e.g. DHE or ECHDE). This
has implications for ciphersuite configuration.
• Clients provide a “key_share” in the ClientHello. This has consequences for “group”
configuration.
• Sessions are not established until after the main handshake has been completed.
There may be a gap between the end of the handshake and the establishment of a

Revision 1 — August 2022 40


Release Notes Skylight element: GT Version 7.9.4

session (or, in theory, a session may not be established at all). This could have impacts
on session resumption code.
• Renegotiation is not possible in a TLSv1.3 connection
• More of the handshake is now encrypted.
• More types of messages can now have extensions (this has an impact on the custom
extension APIs and Certificate Transparency)
• DSA certificates are no longer allowed in TLSv1.3 connections

Note: Only TLSv1.3 is supported at this time, therefore there is no OpenSSL to support
DTLSv1.3 at this time.

Revision 1 — August 2022 41


Release Notes Skylight element: GT Version 7.9.4

5.2 Addressed Issues

AC-16152 Port Phy config loses configuration with 100M fixed speed for Copper SFP
Customer reported Port Phy config loses configuration with 100M fixed speed for others
Copper SFP (not 7SV-000).
This issue has been fixed.

AC-16540 LACP timeout setting not following when going from custom 1000 to sub50
Customer reported LACP does not revert to sub50ms timeout properly when changing
from "custom 1000" to "sub50" setting.
This issue has been fixed.

AC-19301 Configuration of Copper SFP(1000Base-T) Auto Negotiation Disabled


Customer reported configuration of I/F type 1000BASE-T with Auto-Negotiation disable,
which is a setting that is not supported by IEEE 802.3ab.
This issue has been fixed.

AC-20416 Unusual log reported “Server write error: wanted 20 got -1”
After installation or upgrade, customer reported the following unusual log - Server write
error: wanted 20 got -1.
This issue has been fixed.

AC-20510 Periodic log is flooding the syslogs


Customer reported the following log (appearing every hour) is flooding the syslogs:
FLASHD: Config changed /flashmond_bootrefresh.conf
This issue has been fixed.

AC-22795 Disable port becomes enabled after firmware upgrade on GT 7.1.1.8


After firmware upgrade to 7.8.3.1, the disabled port became enabled.
This issue has been fixed.

AC-19794 Copper SFP Manual speed at 100 Mbps not persistent


When a copper SFP is inserted on a 7.9 or 7.8.3, speed is configured at 100 Mbps full duplex,
and the device reboot, the port came back down and the speed is changed to 1Gbps.
This issue has been fixed.

Revision 1 — August 2022 42


Release Notes Skylight element: GT Version 7.9.4

AC-18313 Y.1564 FLR criteria is confusing for the users


In the Y-1564 test, the FLR criterion is unclear, and additional information about the scale
of the value would be useful for the user.
This issue has been fixed.

AC-11198 Copper LAG port state changes from Up > Dormant > Down instead of Up >Down
while link is disconnected
When a connected link goes down, the port is expected to switch from Up to Down quickly,
however, the port is switching from Up to Dormant and then to Down.
This issue has been fixed.

AC-4316 Cannot create the second VCA when 2 Operator’s TPID are different
When Operator1’s TPID and Operator2’s TPID are different, only 1 VCA will be successfully
created. In this scenario, a second VCA cannot be created. This is a limitation of the VCE/VCA
model and it will result in the following error message: “This platform doesn’t support this
feature”.
This issue has been fixed.

AC-4324 Flow-1 automatically switches back to out-of-service mode during upgrade


process
When upgrading the performance element from a pre-7.7 release, if both RFC2544 flows
were enabled, then the “Flow type” field in the “First flow profile settings” will be
automatically reconfigured to the “Out-of-service” state as part of the upgrade process.
This issue has been fixed.

Revision 1 — August 2022 43


Release Notes Skylight element: GT Version 7.9.4

5.3 Operational Considerations and Known Limitations


Important Notes

 The Skylight element: LX firmware is delivered in a consolidated file prefixed by “ACC”,


e.g. ACC_7.X_YYYY.afl. This file contains the firmware for the GT, GX , LX and LT
Performance Element products. It cannot be used with any other product.
 IMPORTANT: Prior to upgrading the firmware on a unit where the History Buckets
feature is enabled, certain precautions may need to be taken to prevent a loss of history
data during the upgrade. Refer to ATRC-B10797 for details.
 In a G.8032 ring configuration, the Skylight element: LX supports a maximum of 62
policies on the LAG port (i.e. policies that govern how traffic is dropped from the ring to
UNI ports). This limitation does not apply to the UNI ports (i.e. policies that govern how
traffic is added to the ring) unless the VLAN-tagged customer traffic is passed
transparently from the UNI port to the ring through one-to-one mapping.
One way to avoid this limitation and maximize the number of usable UNI policies is to
encapsulate multiple customer VLANs (coming from the UNI) under a single service
provider VLAN on the ring. Doing so reduces the number of policies required by the LAG
port.

ATRC-D15900 LBR message still occurs when MIP and MEP are different VLAN type
Unicast CFM-LBM frames sent to Accedian Demarcation devices are VLAN TPID unaware.

ATRC-D17907 Missing packets on RFC2544 generator layer-3 (2 flows)


With an RFC2544 generator layer-3 that has flow 1 set as QinQ and flow 2 set as no
encapsulation (or QinQ), packets are missing on flow 2 after completing the RFC2544 with
two flows.

ATRC-D17871 Error loading proper page indexing when loading pages via URL/back
Possible error loading proper page indexing when loading WEB pages that contain paged
tables via URL (i.e. back). Some WEB pages contain a table paging feature that displays a
certain number of instances per page within a table. As the user cycles through the different
pages, he will be able to view different instances and the URL will be updated to save this
information. This allows a user to re-load the same view by using the URL (i.e. saving
bookmark, clicking back to reload page, etc.). However, when reloading a web page using
this method, incorrect index offsets may be observed for instances on certain pages.

Revision 1 — August 2022 44


Release Notes Skylight element: GT Version 7.9.4

ATRC-D13944 Generator RFC2544 in-service and monitor operate incorrectly


When an L2PT rule is enabled with forwarding mode set to either pop or replace and the
frame is S-VLAN tagged, the frame is dropped instead of being forwarded.

ATRC-D16848 Filter does not catch IPv6 Extension Headers


Because the frame header fields extraction depth is limited to the first 96 bytes of a frame,
any fields of an IPv6 frame that are beyond the first 96 bytes will not be extracted.
Therefore, they will not be found in the classification key used against an IPv6 filter.
Also, the following IPv6 Next Headers identifying Extension Headers will be skipped.
Therefore, they will not be found in the classification key used against an IPv6 filter:
• Hop-by-Hop options (0)
• Destination options (60)
• Routing header (43)
• Fragment header (44)
• Authentication header (51)
• Mobility header (135)

ATRC-D17233 SNMP IPv6 Filtering and Loopback is not supported


SNMP IPv6 Filtering and Loopback is not supported in this release.

ATRC-D15894 LBR message still occurring when MIP is created with MD level
Unicast CFM-LBM frames sent to Accedian Demarcation devices do not validate the MEG
level in the frame.

ATRC-D15523 DOWN MEP using VCE does not work with un-tag packet
We do not support EVC Client Interface for an untagged MEP on a VCE. We only support
untagged MEPs, if it is a Down MEP on a physical port of the VCE.

ATRC-D15473 The TP-Z-PCP-Mapping does not work properly


An Up MEP defined on the TP-Z port of a VCE, which is defined with frame-type ‘all-to-
one’, does not support the PCP mapping since it necessarily becomes untagged when
egressing TP-A. The PCP value used is then inherited from the CFM object when additional
components are in the transmission path.

Revision 1 — August 2022 45


Release Notes Skylight element: GT Version 7.9.4

ATRC-D15229 DownMEP_VCE: VCE is using TPID but it is affected by changing s-vlan mode
0x9100
The user needs to configure the S-VLAN ethertype located under General system settings,
prior to configuring any VCE or CFM elements. If the user changes this setting after
configuring other elements, they may see some display discrepancies.

ATRC-D07187 LAG Port remains DOWN with LACP, but UP with Link status
When using LACP, if the catchall L2PT rules are enabled, LACP frames will not be handled
correctly to allow LACP to operate correctly.
Workaround: Create LACP rules that also apply to the L2PT configuration.

ATRC-D05982 Limited availability of the OAM Loopback feature


The 802.3ah OAM loopback feature is not functional on the following platforms:
• Skylight element: GT
• Skylight element: GX
• Skylight element: LT
• Skylight element: LX

ATRC-D05907 Reserved value no longer allowed in a Y.1731 configuration


As of firmware version 6.4.2, VLAN ID 4095 is a reserved value and is no longer allowed in
Y.1731 configurations.
If VLAN 4095 was used in a previous firmware version, support in version 6.4.2 will be
maintained through a firmware upgrade. However, any MA/MEG instances using VLAN
4095 cannot be recreated in the event of a deletion.

ATRC-D05812 SNMP returns incorrect values for certain PAA configuration parameters
Polling the following PAA configuration OIDs with SNMP returns “0” instead of the actual
value:
• acdPaaUdpCfgOneWayDelayMax
• acdPaaUdpCfgOneWayDelayThresh
• acdPaaUdpCfgOneWayAvgDelayThresh
• acdPaaUdpCfgOperationMode
• acdPaaUdpCfgPktSize
• acdPaaUdpCfgSamplingPeriod
• acdPaaUdpCfgPeerID

Revision 1 — August 2022 46


Release Notes Skylight element: GT Version 7.9.4

ATRC-D05755 L2PT rules for ESMC also catch other slow protocols
An L2PT rule configured for the ESMC protocol may also catch the following protocol
frames:
• Link OAM
• LAMP
• LACP
If separate L2PT rules are not required for these protocols, no specific intervention is
necessary.
If separate L2PT rules are required for these protocols, assign a higher rule ID to ESMC to
ensure that it does not interfere with other protocols. As a result, other protocol filter rules
will be processed before the ESMC rule.

ATRC-D05720 VC Agent: Changing the local time can cause a disconnection from Vision EMS
Changing the local time on a unit can cause the Vision Collect agent to disconnect from
Vision EMS. The agent will reconnect automatically. No PM data is lost; if a transfer is
interrupted, the data will be retransferred once the connection is restored.

ATRC-D05446 Slight variation in BLUE queue full/empty threshold percentage values


The Web interface for the following products accepts values between 0 and 100 for the
BLUE Queue Full Threshold and BLUE Queue Empty Threshold parameters:
• Skylight element: GT
• Skylight element: GX
• Skylight element: LT
• Skylight element: LX
These values are expressed as percentages. However, this percentage value is
subsequently converted to a binary number and mapped to the range 0-128, as the
underlying register is 7 bits in length.
In most cases, the initial percentage will not correspond to an exact binary value. When this
value is then converted back to a decimal percentage for display purposes, the end result
may differ slightly from what was initially entered.

ATRC-D05432 History CSV files may not all contain the same range of period numbers
The exported history CSV files may not all contain the identical range of period numbers,
depending on when the given history metrics were collected. Enabling multiple categories
of history metrics with many instances requires more processing than history metrics with
fewer categories and instances. Since the history files are processed sequentially, some
exported files may consequently present different period numbers compared to others.

Revision 1 — August 2022 47


Release Notes Skylight element: GT Version 7.9.4

For example, the CFM DMM file may show periods 16-30, whereas the CFM SLM file may
show periods 17-31, since it was processed afterwards. The reason for this variation is that
new periods are included in the CSV file as soon as they become available.
This is the expected behavior. There is no period number synchronization between history
categories. Note that all periods are exported in the CSV files and no data is lost.

ATRC-D05382 CoS Mapping: Yellow PCP Out is not mapped to a queue


The following products use CoS mapping to define the internal CoS that service frames will
use in the unit.
• Skylight element: GT
• Skylight element: GX
• Skylight element: LT
• Skylight element: LX
However, the pre-marking color parameter (set to Green or Yellow) is disregarded when
mapping a flow to a traffic queue. The system’s internal CoS always uses the configured
Green PCP value to map a flow to a queue, regardless of whether the pre-marking is set to
Green or Yellow.

ATRC-D04263 Web Interface: VLAN ID value not properly validated when creating a VID set
The VLAN ID value is not properly validated when creating a VID set in the Web Interface.
Entries outside the valid range (0–4095) are accepted, as well as character strings; however,
the resulting VID set instance is empty with no VLAN ID assigned.
This issue only concerns the Web Interface; the CLI performs the proper validation and
rejects invalid entries as expected.
The following products and firmware versions are affected:

Product Name Firmware Versions

TE-x Performance Element 5.1 – 6.4.3

GT/GT-S Performance Element, now 6.3 – 7.3


Skylight element: GT/GT-S (7.9) 7.9.1

GT-Q/GT-QE Performance Element 7.1.1 – 7.3

GX/GX-S Performance Element, now 6.3 – 7.3


Skylight element: GX/GX-S (7.9) 7.9.1

10GE CE/NE Performance Element 5.0 – 6.3

LT/LT-S Performance Element, now 6.3 – 7.3


Skylight element: LT/LT-S (7.9) 7.9.1

Revision 1 — August 2022 48


Release Notes Skylight element: GT Version 7.9.4

Product Name Firmware Versions

Skylight element: LX-S 7.9.1

FS/FS 10G Performance Element 1.0 – 1.1

ATRC-D04040 Syslog error message at login after configuring RADIUS


After a first-time RADIUS configuration, a false syslog error may be generated due to start-
up conditions when the user logs in.
The syslog message is as follows:
Jan 1 00:19:13 C074-0010 dropbear[1620]: rc_get_seqnbr: fscanf
failure: /tmp/radius.seq
This message has no consequence and can be ignored.

ATRC-D03949 Modified syntax for CLI command “bandwidth-generator add”


Starting in firmware version 6.4, the CLI command bandwidth-generator add is used to
configure regulators and bandwidth sharing envelopes.
Previous syntax (before 6.4):
bandwidth-regulator add <regulator-name> …
New syntax (6.4 and later):
bandwidth-regulator add regulator <regulator-name> …
or
bandwidth-regulator add envelope <envelope-name> …
Consequently, the word regulator is reserved as of firmware version 6.4 and cannot be used
as a regulator name, although the former syntax is still supported for backward
compatibility.
These changes are illustrated in the following examples.
Preferred syntax:
bandwidth-regulator add regulator regulator1 cir 20000 …
Allowed (for backward compatibility):
bandwidth-regulator add regulator1 cir 20000 …
Not allowed (triggers an error message):
bandwidth-regulator add regulator cir 20000 …
(invalid parameter value)

Revision 1 — August 2022 49


Release Notes Skylight element: GT Version 7.9.4

ATRC-D03939 Maximum number of complex rules for ERP traffic


For any unit that supports G.8032, the system automatically creates a default Layer-2 filter
traffic policy (used for the ring pass-through traffic) whenever a LAG port is configured for
ERP.
Since this default policy consumes one of the unit’s available complex rules (i.e., using a
Layer-2 or IPv4 filters), the number of complex rules available to users on that LAG port is
reduced by 1. This situation has no impact on other ports.

ATRC-D02695 Timestamps of report periods are not always contiguous


The data collected by Vision EMS in high-resolution mode can occasionally show
consecutive records with timestamps that are not contiguous.
Be aware of the following limitations:
• When data is collected in high-resolution (1 second) mode, two consecutive
measurements can sometimes present the same timestamp, or show a gap
between the timestamps. This is caused by rounding the time value to a
granularity of 1 second.
Please note that in this case, no periods or measurements are lost, i.e. all periods
are consecutive, and none are missing.
• There can be a timestamp gap or overlap when the unit is first synchronized by
NTP, PTP or GPS. As the Flow meter may be acquiring data before the
synchronization is complete, a time adjustment could affect the timestamps. No
periods or measurements are lost.
Inconsistencies may also surface in the timestamps collected before a system reboot when
compared to those collected after the reboot.

ATRC-D02648 New behavior when re-enabling CFM-PL instances


In firmware version 6.3.1, the CFM packet loss (PL) behavior has been modified as follows:
Previous behavior (before 6.3.1): When a packet loss (PL) instance is re-enabled after being
disabled, the current period results contain the last values from the point at which the
instance was disabled.
New behavior (6.3.1. and later): When a packet loss (PL) instance is re-enabled after being
disabled, the current period results are cleared, and measurements begin from 0.

ATRC-D02057 Syslog: Entries are sometimes not displayed in the system log
When a large number of events occur at the same time (e.g. raising or clearing hundreds of
alarms simultaneously), some entries may be absent from the syslog. Missing entries do
not imply that the corresponding events/actions were not properly executed.
For example, in the case of alarm storms, although syslog messages for some status
changes are not displayed, all the alarms are updated to the correct status and the
corresponding SNMP traps are reported.

Revision 1 — August 2022 50


Release Notes Skylight element: GT Version 7.9.4

ATRC-7830 RFC-2544 testsuite: Report displays incorrect unit identifier information


When running the RFC-2544 testsuite after modifying the unit identifier (System ▶ DNS ▶
host name), the generated report contains the previous unit identifier.

ATRC-B10797 Firmware upgrade considerations pertaining to history buckets


Since firmware version 6.3.1, several software modifications have optimized how the
history data is handled and stored to flash memory. Before proceeding with the firmware
upgrade, take the following precautions:
• To prevent any loss of history data, ensure that all data has been transferred to
the file server.
• Be aware of certain side-effects caused by these optimizations on systems on
which the History Buckets feature is enabled.
Upgrading from any pre-6.3.1 version to 6.3.1. and later:

• All history data present on the flash memory is deleted during the upgrade
process.
Upgrading from version 6.3.1 to 6.4.2:

• No history data is deleted during the upgrade process.


Upgrading from version 6.3.1 or 6.4.2 to any later version:

• All history data present on the flash memory is deleted during the upgrade
process.
Upgrading from version 6.4.2.1 to 7.0:

• All history data present on the flash memory for the Policy, Regulator, Shaper,
SOAM DMM and SOAM PL is deleted during the upgrade process.
Upgrading from version 6.4.2.1 to 7.2:

• All history data present on the flash memory for the Policy, Regulator, Shaper,
SOAM DMM and SOAM PL is deleted during the upgrade process.

ATRC-7572 Y.1564 one-way flows must be received on the same SAT server port
If one-way test flows from multiple Y.1564 generators are sent to a SAT server (i.e. a remote
unit), all flows must terminate on the same physical port. For example, terminating eight
flows on one port and eight other flows on a different port is not supported.

ATRC-7028 No VLAN information in LLDP frames


LLDP frames sent by the unit only contain the interfaces’ IP address and index values.
Information on the interfaces’ VLAN settings is not available at this time.

Revision 1 — August 2022 51


Release Notes Skylight element: GT Version 7.9.4

ATRC-6906 RFC-2544 monitors are not independent


When using both RFC-2544 monitors in bypass mode to monitor Layer-2 and Layer-3 test
traffic flows, both monitors will report the Layer-3 flow statistics. If the monitor configured
for Layer-2 is disabled, the other monitor (Layer-3) does not report any statistics.

ATRC-6869 Obtaining the UTC offset from the PTP master is not supported
The option to obtain the UTC offset from the PTP master is not yet supported. As such, the
offset provided in the announce messages from the PTP master are not applied to the time
information on the unit. Only the locally defined UTC offset can be used.

ATRC-6846 IPv6 router-advertised addresses are lost when configuring other addresses
After an interface has configured itself with one or several addresses from IPv6 router
advertisements, configuring any other address (whether static or DHCP) will flush the
router-advertised addresses.
This is the intended implementation, since configuring a static IP or enabling DHCP
supersedes the router advertisements.

ATRC-6758 Higher number of Y.1731 frames sent over a period


The number of Y.1731 sample frames (CCM, DMM or SLM) sent over a period can be slightly
higher than expected.
For example, if SLM is configured with an interval of 100 ms and a period of 60 seconds, it
is possible that 601 or 602 samples will be sent during the period instead of 600. This is
caused by a rounding issue related to timer division.
This issue does not lead to packet loss or inaccurate delay results; it is merely a variation of
the number of samples sent over a period.

ATRC-6672 Plug & Go ring protection from customer beacon


When a new unit is added to a G.8032 ERP ring and is in the process of being provisioned
using the Plug & Go feature, it is important to ensure that no foreign beacons enter the ring
from the UNI side (e.g. from a customer). Taking this measure prevents the new ring unit
from being provisioned by the wrong beacon.

ATRC-6604 Web interface may be slow with Mozilla Firefox version 14.0.1 to 22
When using the Mozilla Firefox Web browser version 14.0.1 to 22 to manage the unit, the
response time can sometimes increase, which makes the Web interface slow to operate.
Workaround: Use Firefox version 23 or higher.

Revision 1 — August 2022 52


Release Notes Skylight element: GT Version 7.9.4

ATRC-6509 LAG-Protection: ETH-CSF cannot validate port state on LACP-based UNI links
If enabled, ETH-CSF cannot validate the link status of an LACP-based protected UNI link.
Under such circumstances, the remote fault cannot be propagated. Since ETH-CSF is based
on link-status and LACP is based on signaling, it is currently impossible to indicate to CSF
that the link is logically down, yet still physically up.

ATRC-6425 CLI traceroute command does not support all listed options
The CLI traceroute command does not support the following options:
• -q (number of queries)
• -s (source IP address)
• -g (gateway)

ATRC-6132 VSP reflector responds to invalid MAC addresses on the management port
The V-NID reflector functionality is only intended for use on traffic ports, not on out-of-
band management ports. However, the out-of-band management port will reflect any
ETH-VSP frames it receives. While traffic ports only reflect VSP frames that match the
port’s specific MAC address, the out-of-band management port will reflect VSP frames that
match the MAC address belonging to any of the unit’s ports (MAC range).

ATRC-5790 EVC Mapping: “Preserve VLAN - New CFI/PCP” limitations


When setting EVC Mapping to “Preserve VLAN - New CFI/PCP”, the following limitations
should be taken into consideration:
• DSCP/IP Precedence information is not extracted from triple-tagged frames.
• DSCP/ IP Precedence information is not extracted from 802.2 SNAP/LLC frames.
• DSCP/ IP Precedence/PCP information is not extracted from S-VLAN (0x9100)
tagged frames, unless 0x9100 is set globally as the default S-VLAN Ethertype.
This EVC mapping action can corrupt untagged frames. Therefore, a filter matching at least
one VLAN must be used to ensure the classified frames are tagged.

ATRC-5646 EVC mapping actions that modify VLAN tags must not be used with untagged
traffic
EVC mapping actions that involve replacing or modifying a VLAN tag should not be used if
the traffic is untagged. These EVC mapping actions are:
• Replace
• Pop & Replace
• Preserve VLAN – New CFI/PCP
Performing VLAN modifications on untagged traffic could result in altering the frames.
There is no traffic policy validation to enforce the presence of a VLAN filter with these EVC

Revision 1 — August 2022 53


Release Notes Skylight element: GT Version 7.9.4

mapping actions. You must therefore ensure that any policy using these EVC mapping
actions is configured with a VLAN filter.

ATRC-5474 Frame count statistics may be inconsistent if SLM is disabled in mid-period


If an SLM instance is disabled in the middle of a reference period, the ETH-SLM and
ETH-SLR frame counts shown in the MEP statistics may not be consistent with those
shown in the SLM statistics. This is normal, as the information may not have been refreshed
at the very moment when the SLM instance was disabled.
This behavior is a normal consequence of disabling the SLM instance during a period and is
by design. SLM functions as expected in continuous operation.

ATRC-5364 CPU-destined ingress traffic can be processed on an LACP link while not in the
collecting/distributing state
When using LACP status-based protection, CPU-destined traffic received on a port can be
processed by the software even when the local (actor) LACP link status is not in the
collecting/distributing state. This situation applies to CFM traffic (LBM, LTM, DMM, CCM,
etc.), PAA traffic and L2PT traffic.

ATRC-5254 Web session does not time out if automatic refresh is enabled
The active session of the Web interface will never time out if automatic refresh is enabled
in a page.

ATRC-5197 ARP Requests are sent out on a port when interface is disabled
Many ARP requests are sent out on a port even if the interface associated with the port is
disabled.

ATRC-5196 “cfm show statistics” CLI command shows incorrect RDI and CCM sequence errors
This CLI command does not accurately report the count of CCM sequence errors. This
information can be displayed using the cfm show mep statistics command.

ATRC-5107 Users without “Policy” permissions can clear policy statistics in the Web interface
Users are currently able to clear the Policy statistics in the Web interface (but not in the
CLI), regardless of their assigned permission settings.

ATRC-4560 CLI: CFM naming convention (MEP, Pkt-loss, DMM)


When assigning a CFM name to an instance in the GUI, the name must not be composed
solely of digits; CFM names must always include at least one letter. If the name contains
only digits, the CLI interprets the name as an instance index.

Revision 1 — August 2022 54


Release Notes Skylight element: GT Version 7.9.4

ATRC-4076 SCP -z option not working with certain servers


Certain SSH servers, such as Solaris and several Linux enterprise versions, do not support
the SCP -z option to specify the username. Once the SCP fails, FTP no longer functions since
it uses the same process. The CPU must be restarted for FTP to function.
This issue is related to how the SSHd server is configured. Servers are usually configured to
use PAM (Pluggable Authentication Modules) for account and session management. SSHd
can also rely on PAM for authentication; PAM then executes its authentication scheme
based on its configuration for that login method (for example: /etc/pam.d/sshd).
Configuring Response Authentication:
• With OpenSSH, ChallengeResponseAuthentication in /etc/ssh/sshd_config should
be set to No.
• On Solaris, PAMAuthenticationViaKBDInt in /etc/sshd_config should be set to No.
Alternate Solutions:
• Change the PAM configuration for SSHd (expert).
• Use a public key authentication.
Modification Procedure:
• Solaris:
o Log in with administrative privileges.
o Edit file /etc/ssh/sshd_config to set PAMAuthenticationViaKBDInt to No.
o Save file and exit.
o Restart service: svcadm restart network/ssh.
• Ubuntu Linux (OpenSSH):
o Log in with administrative privileges.
o Edit file /etc/ssh/sshd_config to set ChallengeResponseAuthentication to No.
o Save file and exit.
o Restart service: sudo service ssh restart.

ATRC-3533 SyncE is not supported with copper SFP


Copper SFPs use the internal 25 MHz oscillator instead of the SyncE recovered clock.
Consequently, SyncE is not supported for copper SFPs.

ATRC-3285 Web browser refresh deletes the current search filter


Using the browser Refresh command (F5 or Ctrl+R) does not only refresh the page values,
it also reloads the page completely. Doing so eliminates any search filters that were entered.
This behavior is considered normal.

Revision 1 — August 2022 55


Release Notes Skylight element: GT Version 7.9.4

5.4 MIB Changes


None

Revision 1 — August 2022 56


Release Notes Skylight element: GT Version 7.9.4

6. Firmware Version 7.9.1_23672 (2020-11-12)

6.1 New Features and Enhancements

AC-19192 Flash Boot Refresh


The Flash Boot Refresh is an additional mechanism to help periodically check the boot area;
if the boot sector is considered invalid or corrupted, the software will be re-
programmed with the latest bootloader image.

AC-18551 Disregard Pbit in DMM


Disregards Pbit in DMM available in the uSOAM stack by inserting of the Test-Id-TLV in
each DMM packet sent. This TLV is to be used to differentiate DMR flows (in RX) instead
of the currently used p-bit.

AC-17898 Skylight performance element GUI Enhancements


The GUI has been enhanced to make it easier to read, these changes include:
• Deep navy color for the text.
• Changed the font to medium instead of normal or bold.
• Borders are thicker and deep navy colour.
• More space was added between blocks to ensure the GUI is less compact.
• Menu has more space and menu items selected are bolder with shading in the
selected menu tabs.

Revision 1 — August 2022 57


Release Notes Skylight element: GT Version 7.9.4

6.2 Addressed Issues

AC-19850 User Permission “traffic” does nothing


Traffic privilege in the group permission does not seem to do anything.
This issue has been fixed.

AC-19432 Transmission path interferes with existing MEP


When using firmware 7.8.3 we cannot configure the same vlan using different Meg Levels.
When creating the MEP, the system returns with the following error:
Transmission path interferes with existing MEP.
This issue has been fixed.

AC-18080 RFC2544 Testsuite Fails to start


The RFC 2544 testsuite fails to start. As soon the test is started, it fails at the binary test
with an error message: “Fail to reach peer”.
This issue has been fixed.

AC-17830 Software 7.9 restricts creation of PAA with QnQ via the web interface
Software 7.9 does not allow the user to create a PAA with QnQ via the web interface, if user
creates a PAA with 2 VLAN and it will display error message: "ERROR: Invalid VLAN ID".
The CLI is working correctly.
This issue has been fixed.

AC-17286 Management unreachable


Management access failed.
This issue has been fixed.

AC-16957 Y.1564 test aborts with CIR = 0 and EIR > 0


Software does not allow the user to preform Y.1564 test with CIR=0 and EIR>0.
This issue has been fixed.

AC-14277 Y.1564 test result - IR display is not as expected


When user performs a test at 1M with EMIX, the IR in the result is 0.999, which is not
expected.
This issue has been fixed.

Revision 1 — August 2022 58


Release Notes Skylight element: GT Version 7.9.4

AC-16539 LACP timeout options clarification request


LACP timeout option descriptions are incorrect in user documentation and on-line web help.
This issue has been fixed.

AC-20341 RFC 2544 testsuite report display issue when test fails
When the test passes, the results display is correct, however when it fails (Binary search
failure (1)) the RX rate (in frames/sec) is greater the TX rate (in frame/sec).
This issue has been fixed.

AC-20067 Update online help for Traffic privileges


Online help for traffic privileges stated: Edit/Enable VLAN encapsulation settings:
forwarding. This was incorrect, and should have stated: Edit/Enable VLAN level and
Working Rate settings from the Traffic configuration.
This issue has been fixed.

AC-19794 Copper SFP Manual speed at 100 Mbps not persistent


When a copper SFP is inserted on a 7.9 or 7.8.3, speed is configured at 100 Mbps full duplex,
and the device reboot, the port came back down and the speed is changed to 1Gbps.
This issue has been fixed.

AC-18313 Y.1564 FLR criteria is confusing for the users


In the 1564 test, the FLR criterion is unclear, and additional information about the
scale of the value would be useful for the user.
This issue has been fixed.

Revision 1 — August 2022 59


Release Notes Skylight element: GT Version 7.9.4

6.3 Operational Considerations and Known Limitations


Important Notes

 The Skylight element: LX firmware is delivered in a consolidated file prefixed by “ACC”,


e.g. ACC_7.X_YYYY.afl. This file contains the firmware for the GT, GX, LX and LT
Performance Element products. It cannot be used with any other product.
 IMPORTANT: Prior to upgrading the firmware on a unit where the History Buckets
feature is enabled, certain precautions may need to be taken to prevent a loss of history
data during the upgrade. Refer to ATRC-B10797 for details.
 In a G.8032 ring configuration, the Skylight element: LX supports a maximum of 62
policies on the LAG port (i.e. policies that govern how traffic is dropped from the ring to
UNI ports). This limitation does not apply to the UNI ports (i.e. policies that govern how
traffic is added to the ring) unless the VLAN-tagged customer traffic is passed
transparently from the UNI port to the ring through one-to-one mapping.
One way to avoid this limitation and maximize the number of usable UNI policies is to
encapsulate multiple customer VLANs (coming from the UNI) under a single service
provider VLAN on the ring. Doing so reduces the number of policies required by the LAG
port.

AC-11198 Copper LAG port state changes from Up > Dormant > Down instead of Up >Down
while link is disconnected
When a connected link goes down, the port is expected to switch from Up to Down quickly,
however, the port is switching from Up to Dormant and then to Down.

AC-4316 Cannot create the second VCA when 2 Operator’s TPID are different
When Operator1’s TPID and Operator2’s TPID are different, only 1 VCA will be successfully
created. In this scenario, a second VCA cannot be created. This is a limitation of the VCE/VCA
model and it will result in the following error message: “This platform doesn’t support this
feature”.

AC-4324 Flow-1 automatically switches back to out-of-service mode during upgrade


process
When upgrading the performance element from a pre-7.7 release, if both RFC2544 flows
were enabled, then the “Flow type” field in the “First flow profile settings” will be
automatically reconfigured to the “Out-of-service” state as part of the upgrade process.

Revision 1 — August 2022 60


Release Notes Skylight element: GT Version 7.9.4

ATRC-D15900 LBR message still occurs when MIP and MEP are different VLAN type
Unicast CFM-LBM frames sent to Accedian Demarcation devices are VLAN TPID unaware.

ATRC-D17907 Missing packets on RFC2544 generator layer-3 (2 flows)


With an RFC2544 generator layer-3 that has flow 1 set as QinQ and flow 2 set as no
encapsulation (or QinQ), packets are missing on flow 2 after completing the RFC2544 with
two flows.

ATRC-D17871 Error loading proper page indexing when loading pages via URL/back
Possible error loading proper page indexing when loading WEB pages that contain paged
tables via URL (i.e. back). Some WEB pages contain a table paging feature that displays a
certain number of instances per page within a table. As the user cycles through the different
pages, he will be able to view different instances and the URL will be updated to save this
information. This allows a user to re-load the same view by using the URL (i.e. saving
bookmark, clicking back to reload page, etc.). However, when reloading a web page using
this method, incorrect index offsets may be observed for instances on certain pages.

ATRC-D13944 Generator RFC2544 in-service and monitor operate incorrectly


When an L2PT rule is enabled with forwarding mode set to either pop or replace and the
frame is S-VLAN tagged, the frame is dropped instead of being forwarded.

ATRC-D16848 Filter does not catch IPv6 Extension Headers


Because the frame header fields extraction depth is limited to the first 96 bytes of a frame,
any fields of an IPv6 frame that are beyond the first 96 bytes will not be extracted.
Therefore, they will not be found in the classification key used against an IPv6 filter.
Also, the following IPv6 Next Headers identifying Extension Headers will be skipped.
Therefore, they will not be found in the classification key used against an IPv6 filter:
• Hop-by-Hop options (0)
• Destination options (60)
• Routing header (43)
• Fragment header (44)
• Authentication header (51)
• Mobility header (135)

ATRC-D17233 SNMP IPv6 Filtering and Loopback is not supported


SNMP IPv6 Filtering and Loopback is not supported in this release.

Revision 1 — August 2022 61


Release Notes Skylight element: GT Version 7.9.4

ATRC-D15894 LBR message still occurring when MIP is created with MD level
Unicast CFM-LBM frames sent to Accedian Demarcation devices do not validate the MEG
level in the frame.

ATRC-D15523 DOWN MEP using VCE does not work with un-tag packet
We do not support EVC Client Interface for an untagged MEP on a VCE. We only support
untagged MEPs, if it is a Down MEP on a physical port of the VCE.

ATRC-D15473 The TP-Z-PCP-Mapping does not work properly


An Up MEP defined on the TP-Z port of a VCE, which is defined with frame-type ‘all-to-
one’, does not support the PCP mapping since it necessarily becomes untagged when
egressing TP-A. The PCP value used is then inherited from the CFM object when additional
components are in the transmission path.

ATRC-D15229 DownMEP_VCE: VCE is using TPID but it is affected by changing s-vlan mode
0x9100
The user needs to configure the S-VLAN ethertype located under General system settings,
prior to configuring any VCE or CFM elements. If the user changes this setting after
configuring other elements, they may see some display discrepancies.

ATRC-D07187 LAG Port remains DOWN with LACP, but UP with Link status
When using LACP, if the catchall L2PT rules are enabled, LACP frames will not be handled
correctly to allow LACP to operate correctly.
Workaround: Create LACP rules that also apply to the L2PT configuration.

ATRC-D05982 Limited availability of the OAM Loopback feature


The 802.3ah OAM loopback feature is not functional on the following platforms:
• Skylight element: GT
• Skylight element: GX
• Skylight element: LT
• Skylight element: LX

ATRC-D05907 Reserved value no longer allowed in a Y.1731 configuration


As of firmware version 6.4.2, VLAN ID 4095 is a reserved value and is no longer allowed in
Y.1731 configurations.

Revision 1 — August 2022 62


Release Notes Skylight element: GT Version 7.9.4

If VLAN 4095 was used in a previous firmware version, support in version 6.4.2 will be
maintained through a firmware upgrade. However, any MA/MEG instances using VLAN
4095 cannot be recreated in the event of a deletion.

ATRC-D05812 SNMP returns incorrect values for certain PAA configuration parameters
Polling the following PAA configuration OIDs with SNMP returns “0” instead of the actual
value:
• acdPaaUdpCfgOneWayDelayMax
• acdPaaUdpCfgOneWayDelayThresh
• acdPaaUdpCfgOneWayAvgDelayThresh
• acdPaaUdpCfgOperationMode
• acdPaaUdpCfgPktSize
• acdPaaUdpCfgSamplingPeriod
• acdPaaUdpCfgPeerID

ATRC-D05755 L2PT rules for ESMC also catch other slow protocols
An L2PT rule configured for the ESMC protocol may also catch the following protocol
frames:
• Link OAM
• LAMP
• LACP
If separate L2PT rules are not required for these protocols, no specific intervention is
necessary.
If separate L2PT rules are required for these protocols, assign a higher rule ID to ESMC to
ensure that it does not interfere with other protocols. As a result, other protocol filter rules
will be processed before the ESMC rule.

ATRC-D05720 VC Agent: Changing the local time can cause a disconnection from Vision EMS
Changing the local time on a unit can cause the Vision Collect agent to disconnect from
Vision EMS. The agent will reconnect automatically. No PM data is lost; if a transfer is
interrupted, the data will be retransferred once the connection is restored.

ATRC-D05446 Slight variation in BLUE queue full/empty threshold percentage values


The Web interface for the following products accepts values between 0 and 100 for the
BLUE Queue Full Threshold and BLUE Queue Empty Threshold parameters:
• Skylight element: GT
• Skylight element: GX

Revision 1 — August 2022 63


Release Notes Skylight element: GT Version 7.9.4

• Skylight element: LT
• Skylight element: LX
These values are expressed as percentages. However, this percentage value is
subsequently converted to a binary number and mapped to the range 0-128, as the
underlying register is 7 bits in length.
In most cases, the initial percentage will not correspond to an exact binary value. When this
value is then converted back to a decimal percentage for display purposes, the end result
may differ slightly from what was initially entered.

ATRC-D05432 History CSV files may not all contain the same range of period numbers
The exported history CSV files may not all contain the identical range of period numbers,
depending on when the given history metrics were collected. Enabling multiple categories
of history metrics with many instances requires more processing than history metrics with
fewer categories and instances. Since the history files are processed sequentially, some
exported files may consequently present different period numbers compared to others.
For example, the CFM DMM file may show periods 16-30, whereas the CFM SLM file may
show periods 17-31, since it was processed afterwards. The reason for this variation is that
new periods are included in the CSV file as soon as they become available.
This is the expected behavior. There is no period number synchronization between history
categories. Note that all periods are exported in the CSV files and no data is lost.

ATRC-D05382 CoS Mapping: Yellow PCP Out is not mapped to a queue


The following products use CoS mapping to define the internal CoS that service frames will
use in the unit.
• Skylight element: GT
• Skylight element: GX
• Skylight element: LT
• Skylight element: LX
However, the pre-marking color parameter (set to Green or Yellow) is disregarded when
mapping a flow to a traffic queue. The system’s internal CoS always uses the configured
Green PCP value to map a flow to a queue, regardless of whether the pre-marking is set to
Green or Yellow.

ATRC-D04263 Web Interface: VLAN ID value not properly validated when creating a VID set
The VLAN ID value is not properly validated when creating a VID set in the Web Interface.
Entries outside the valid range (0–4095) are accepted, as well as character strings; however,
the resulting VID set instance is empty with no VLAN ID assigned.
This issue only concerns the Web Interface; the CLI performs the proper validation and
rejects invalid entries as expected.

Revision 1 — August 2022 64


Release Notes Skylight element: GT Version 7.9.4

The following products and firmware versions are affected:

Product Name Firmware Versions

TE-x Performance Element 5.1 – 6.4.3

GT/GT-S Performance Element, now 6.3 – 7.3


Skylight element: GT/GT-S (7.9) 7.9.1

GT-Q/GT-QE Performance Element 7.1.1 – 7.3

GX/GX-S Performance Element, now 6.3 – 7.3


Skylight element: GX/GX-S (7.9) 7.9.1

10GE CE/NE Performance Element 5.0 – 6.3

LT/LT-S Performance Element, now 6.3 – 7.3


Skylight element: LT/LT-S (7.9) 7.9.1

Skylight element: LX-S 7.9.1

FS/FS 10G Performance Element 1.0 – 1.1

ATRC-D04040 Syslog error message at login after configuring RADIUS


After a first-time RADIUS configuration, a false syslog error may be generated due to start-
up conditions when the user logs in.
The syslog message is as follows:
Jan 1 00:19:13 C074-0010 dropbear[1620]: rc_get_seqnbr: fscanf
failure: /tmp/radius.seq
This message has no consequence and can be ignored.

ATRC-D03949 Modified syntax for CLI command “bandwidth-generator add”


Starting in firmware version 6.4, the CLI command bandwidth-generator add is used to
configure regulators and bandwidth sharing envelopes.
Previous syntax (before 6.4):
bandwidth-regulator add <regulator-name> …
New syntax (6.4 and later):
bandwidth-regulator add regulator <regulator-name> …
or
bandwidth-regulator add envelope <envelope-name> …

Revision 1 — August 2022 65


Release Notes Skylight element: GT Version 7.9.4

Consequently, the word regulator is reserved as of firmware version 6.4 and cannot be used
as a regulator name, although the former syntax is still supported for backward
compatibility.
These changes are illustrated in the following examples.
Preferred syntax:
bandwidth-regulator add regulator regulator1 cir 20000 …
Allowed (for backward compatibility):
bandwidth-regulator add regulator1 cir 20000 …
Not allowed (triggers an error message):
bandwidth-regulator add regulator cir 20000 …
(invalid parameter value)

ATRC-D03939 Maximum number of complex rules for ERP traffic


For any unit that supports G.8032, the system automatically creates a default Layer-2 filter
traffic policy (used for the ring pass-through traffic) whenever a LAG port is configured for
ERP.
Since this default policy consumes one of the unit’s available complex rules (i.e., using a
Layer-2 or IPv4 filters), the number of complex rules available to users on that LAG port is
reduced by 1. This situation has no impact on other ports.

ATRC-D02695 Timestamps of report periods are not always contiguous


The data collected by Vision EMS in high-resolution mode can occasionally show
consecutive records with timestamps that are not contiguous.
Be aware of the following limitations:
• When data is collected in high-resolution (1 second) mode, two consecutive
measurements can sometimes present the same timestamp, or show a gap
between the timestamps. This is caused by rounding the time value to a
granularity of 1 second.
Please note that in this case, no periods or measurements are lost, i.e. all periods
are consecutive, and none are missing.
• There can be a timestamp gap or overlap when the unit is first synchronized by
NTP, PTP or GPS. As the Flow meter may be acquiring data before the
synchronization is complete, a time adjustment could affect the timestamps. No
periods or measurements are lost.
Inconsistencies may also surface in the timestamps collected before a system reboot when
compared to those collected after the reboot.

Revision 1 — August 2022 66


Release Notes Skylight element: GT Version 7.9.4

ATRC-D02648 New behavior when re-enabling CFM-PL instances


In firmware version 6.3.1, the CFM packet loss (PL) behavior has been modified as follows:
Previous behavior (before 6.3.1): When a packet loss (PL) instance is re-enabled after being
disabled, the current period results contain the last values from the point at which the
instance was disabled.
New behavior (6.3.1. and later): When a packet loss (PL) instance is re-enabled after being
disabled, the current period results are cleared, and measurements begin from 0.

ATRC-D02057 Syslog: Entries are sometimes not displayed in the system log
When a large number of events occur at the same time (e.g. raising or clearing hundreds of
alarms simultaneously), some entries may be absent from the syslog. Missing entries do
not imply that the corresponding events/actions were not properly executed.
For example, in the case of alarm storms, although syslog messages for some status
changes are not displayed, all the alarms are updated to the correct status and the
corresponding SNMP traps are reported.

ATRC-7830 RFC-2544 testsuite: Report displays incorrect unit identifier information


When running the RFC-2544 testsuite after modifying the unit identifier (System ▶ DNS ▶
host name), the generated report contains the previous unit identifier.

ATRC-B10797 Firmware upgrade considerations pertaining to history buckets


Since firmware version 6.3.1, several software modifications have optimized how the
history data is handled and stored to flash memory. Before proceeding with the firmware
upgrade, take the following precautions:
• To prevent any loss of history data, ensure that all data has been transferred to
the file server.
• Be aware of certain side-effects caused by these optimizations on systems on
which the History Buckets feature is enabled.
Upgrading from any pre-6.3.1 version to 6.3.1. and later:

• All history data present on the flash memory is deleted during the upgrade
process.
Upgrading from version 6.3.1 to 6.4.2:

• No history data is deleted during the upgrade process.


Upgrading from version 6.3.1 or 6.4.2 to any later version:

• All history data present on the flash memory is deleted during the upgrade
process.
Upgrading from version 6.4.2.1 to 7.0:

Revision 1 — August 2022 67


Release Notes Skylight element: GT Version 7.9.4

• All history data present on the flash memory for the Policy, Regulator, Shaper,
SOAM DMM and SOAM PL is deleted during the upgrade process.
Upgrading from version 6.4.2.1 to 7.2:

• All history data present on the flash memory for the Policy, Regulator, Shaper,
SOAM DMM and SOAM PL is deleted during the upgrade process.

ATRC-7572 Y.1564 one-way flows must be received on the same SAT server port
If one-way test flows from multiple Y.1564 generators are sent to a SAT server (i.e. a remote
unit), all flows must terminate on the same physical port. For example, terminating eight
flows on one port and eight other flows on a different port is not supported.

ATRC-7028 No VLAN information in LLDP frames


LLDP frames sent by the unit only contain the interfaces’ IP address and index values.
Information on the interfaces’ VLAN settings is not available at this time.

ATRC-6906 RFC-2544 monitors are not independent


When using both RFC-2544 monitors in bypass mode to monitor Layer-2 and Layer-3 test
traffic flows, both monitors will report the Layer-3 flow statistics. If the monitor configured
for Layer-2 is disabled, the other monitor (Layer-3) does not report any statistics.

ATRC-6869 Obtaining the UTC offset from the PTP master is not supported
The option to obtain the UTC offset from the PTP master is not yet supported. As such, the
offset provided in the announce messages from the PTP master are not applied to the time
information on the unit. Only the locally defined UTC offset can be used.

ATRC-6846 IPv6 router-advertised addresses are lost when configuring other addresses
After an interface has configured itself with one or several addresses from IPv6 router
advertisements, configuring any other address (whether static or DHCP) will flush the
router-advertised addresses.
This is the intended implementation, since configuring a static IP or enabling DHCP
supersedes the router advertisements.

ATRC-6758 Higher number of Y.1731 frames sent over a period


The number of Y.1731 sample frames (CCM, DMM or SLM) sent over a period can be slightly
higher than expected.
For example, if SLM is configured with an interval of 100 ms and a period of 60 seconds, it
is possible that 601 or 602 samples will be sent during the period instead of 600. This is
caused by a rounding issue related to timer division.

Revision 1 — August 2022 68


Release Notes Skylight element: GT Version 7.9.4

This issue does not lead to packet loss or inaccurate delay results; it is merely a variation of
the number of samples sent over a period.

ATRC-6672 Plug & Go ring protection from customer beacon


When a new unit is added to a G.8032 ERP ring and is in the process of being provisioned
using the Plug & Go feature, it is important to ensure that no foreign beacons enter the ring
from the UNI side (e.g. from a customer). Taking this measure prevents the new ring unit
from being provisioned by the wrong beacon.

ATRC-6604 Web interface may be slow with Mozilla Firefox version 14.0.1 to 22
When using the Mozilla Firefox Web browser version 14.0.1 to 22 to manage the unit, the
response time can sometimes increase, which makes the Web interface slow to operate.
Workaround: Use Firefox version 23 or higher.

ATRC-6509 LAG-Protection: ETH-CSF cannot validate port state on LACP-based UNI links
If enabled, ETH-CSF cannot validate the link status of an LACP-based protected UNI link.
Under such circumstances, the remote fault cannot be propagated. Since ETH-CSF is based
on link-status and LACP is based on signaling, it is currently impossible to indicate to CSF
that the link is logically down, yet still physically up.

ATRC-6425 CLI traceroute command does not support all listed options
The CLI traceroute command does not support the following options:
• -q (number of queries)
• -s (source IP address)
• -g (gateway)

ATRC-6132 VSP reflector responds to invalid MAC addresses on the management port
The V-NID reflector functionality is only intended for use on traffic ports, not on out-of-
band management ports. However, the out-of-band management port will reflect any
ETH-VSP frames it receives. While traffic ports only reflect VSP frames that match the
port’s specific MAC address, the out-of-band management port will reflect VSP frames that
match the MAC address belonging to any of the unit’s ports (MAC range).

ATRC-5790 EVC Mapping: “Preserve VLAN - New CFI/PCP” limitations


When setting EVC Mapping to “Preserve VLAN - New CFI/PCP”, the following limitations
should be taken into consideration:
• DSCP/IP Precedence information is not extracted from triple-tagged frames.
• DSCP/ IP Precedence information is not extracted from 802.2 SNAP/LLC frames.

Revision 1 — August 2022 69


Release Notes Skylight element: GT Version 7.9.4

• DSCP/ IP Precedence/PCP information is not extracted from S-VLAN (0x9100)


tagged frames, unless 0x9100 is set globally as the default S-VLAN Ethertype.
This EVC mapping action can corrupt untagged frames. Therefore, a filter matching at least
one VLAN must be used to ensure the classified frames are tagged.

ATRC-5646 EVC mapping actions that modify VLAN tags must not be used with untagged
traffic
EVC mapping actions that involve replacing or modifying a VLAN tag should not be used if
the traffic is untagged. These EVC mapping actions are:
• Replace
• Pop & Replace
• Preserve VLAN – New CFI/PCP
Performing VLAN modifications on untagged traffic could result in altering the frames.
There is no traffic policy validation to enforce the presence of a VLAN filter with these EVC
mapping actions. You must therefore ensure that any policy using these EVC mapping
actions is configured with a VLAN filter.

ATRC-5474 Frame count statistics may be inconsistent if SLM is disabled in mid-period


If an SLM instance is disabled in the middle of a reference period, the ETH-SLM and
ETH-SLR frame counts shown in the MEP statistics may not be consistent with those
shown in the SLM statistics. This is normal, as the information may not have been refreshed
at the very moment when the SLM instance was disabled.
This behavior is a normal consequence of disabling the SLM instance during a period and is
by design. SLM functions as expected in continuous operation.

ATRC-5364 CPU-destined ingress traffic can be processed on an LACP link while not in the
collecting/distributing state
When using LACP status-based protection, CPU-destined traffic received on a port can be
processed by the software even when the local (actor) LACP link status is not in the
collecting/distributing state. This situation applies to CFM traffic (LBM, LTM, DMM, CCM,
etc.), PAA traffic and L2PT traffic.

ATRC-5254 Web session does not time out if automatic refresh is enabled
The active session of the Web interface will never time out if automatic refresh is enabled
in a page.

ATRC-5197 ARP Requests are sent out on a port when interface is disabled
Many ARP requests are sent out on a port even if the interface associated with the port is
disabled.

Revision 1 — August 2022 70


Release Notes Skylight element: GT Version 7.9.4

ATRC-5196 “cfm show statistics” CLI command shows incorrect RDI and CCM sequence errors
This CLI command does not accurately report the count of CCM sequence errors. This
information can be displayed using the cfm show mep statistics command.

ATRC-5107 Users without “Policy” permissions can clear policy statistics in the Web interface
Users are currently able to clear the Policy statistics in the Web interface (but not in the
CLI), regardless of their assigned permission settings.

ATRC-4560 CLI: CFM naming convention (MEP, Pkt-loss, DMM)


When assigning a CFM name to an instance in the GUI, the name must not be composed
solely of digits; CFM names must always include at least one letter. If the name contains
only digits, the CLI interprets the name as an instance index.

ATRC-4076 SCP -z option not working with certain servers


Certain SSH servers, such as Solaris and several Linux enterprise versions, do not support
the SCP -z option to specify the username. Once the SCP fails, FTP no longer functions since
it uses the same process. The CPU must be restarted for FTP to function.
This issue is related to how the SSHd server is configured. Servers are usually configured to
use PAM (Pluggable Authentication Modules) for account and session management. SSHd
can also rely on PAM for authentication; PAM then executes its authentication scheme
based on its configuration for that login method (for example: /etc/pam.d/sshd).
Configuring Response Authentication:
• With OpenSSH, ChallengeResponseAuthentication in /etc/ssh/sshd_config should
be set to No.
• On Solaris, PAMAuthenticationViaKBDInt in /etc/sshd_config should be set to No.
Alternate Solutions:
• Change the PAM configuration for SSHd (expert).
• Use a public key authentication.
Modification Procedure:
• Solaris:
o Log in with administrative privileges.
o Edit file /etc/ssh/sshd_config to set PAMAuthenticationViaKBDInt to No.
o Save file and exit.
o Restart service: svcadm restart network/ssh.
• Ubuntu Linux (OpenSSH):
o Log in with administrative privileges.
o Edit file /etc/ssh/sshd_config to set ChallengeResponseAuthentication to No.

Revision 1 — August 2022 71


Release Notes Skylight element: GT Version 7.9.4

o Save file and exit.


o Restart service: sudo service ssh restart.

ATRC-3533 SyncE is not supported with copper SFP


Copper SFPs use the internal 25 MHz oscillator instead of the SyncE recovered clock.
Consequently, SyncE is not supported for copper SFPs.

ATRC-3285 Web browser refresh deletes the current search filter


Using the browser Refresh command (F5 or Ctrl+R) does not only refresh the page values,
it also reloads the page completely. Doing so eliminates any search filters that were entered.
This behavior is considered normal.

6.4 MIB Changes


None

Revision 1 — August 2022 72


Release Notes Skylight element: GT Version 7.9.4

7. Firmware Version 7.9_22663 (2020-03-25)

7.1 New Features and Enhancements

AC-12571 Web UI branding alignment with other Skylight user interfaces


WebUI colors, logos and product names have been updated to further align with other
Skylight products and user interfaces.

AC-14205 Session cookies should have httpOnly flag


All sensitive cookies, such as session cookies, are issued with the HttpOnly flag unless the
application specifically needs to access the cookie via scripts. This helps ensure cookies are
handled securely.

AC-15723 Skylight performance element Software Robustness Improvement for FPGA


Communication Loss
Robustness enhancement for Skylight element units has been introduced in order to restore
the device operation quickly and not depend on a physical intervention.

AC-11727 Adjustment to Loopback warning message


The loopback warning message will appear if you change the filter or change the timeout
in order to warn the user the action will be traffic affecting.

7.2 Addressed Issues

AC-15557 Tech-support export does not accept “$” in the password


Tech-support export will truncate the password if there is a "$" in the password.
This issue has been fixed.

AC-12204 Syslog error when disabling and enabling a port


If running LT or GT 7.8.2.1 factory default configuration, an unusual error message is
displayed when disabling or enabling a port. This is because the system is sending a reply
which is not being received by the calling feature. This issue has been fixed.

Revision 1 — August 2022 73


Release Notes Skylight element: GT Version 7.9.4

AC-13713 Port Phy config loses configuration when copper SFP is inserted after setting
100M fixed speed
When performing a software upgrade on a copper SFP unit, from version 7.1.1.3 to 7.1.1.8,
the Port Link speed changes to 1G even if the current setting 100base. This issue has been
fixed.

AC-14111 RADIUS to authenticate using Skylight but only have Read Only on the NIDs
When connecting to the Skylight 19.06 via a user with Radius credentials and while
connecting to the NID via reverse proxy, you only have “Read Only” permissions; if
connecting via a separate user RADIUS (one for Skylight and one for the NIDS), this problem
doesn’t happen. This issue has been fixed.

AC-15352 Layer-3 RFC2544 JDSU/Acterna loopback on GT does not work


Layer-3 RFC2544 JDSU/Acterna loopback on version 6.4.2.7 was working and reflecting
traffic until upgrading the firmware to version 7.8.1. After the upgrade, the loop was still
being discovered and traffic was not reflected. This issue has been fixed.

7.3 Operational Considerations and Known Limitations


Important Notes

 The Skylight element: GT firmware is delivered in a consolidated file prefixed by “ACC”,


e.g. ACC_7.X_YYYY.afl. This file contains the firmware for the GT, GX , LX and LT
Performance Element products. It cannot be used with any other product.
 IMPORTANT: Prior to upgrading the firmware on a unit where the History Buckets
feature is enabled, certain precautions may need to be taken to prevent a loss of history
data during the upgrade. Refer to ATRC-B10797 for details.
 In a G.8032 ring configuration, the Skylight element: GT supports a maximum of 62
policies on the LAG port (i.e. policies that govern how traffic is dropped from the ring to
UNI ports). This limitation does not apply to the UNI ports (i.e. policies that govern how
traffic is added to the ring) unless the VLAN-tagged customer traffic is passed
transparently from the UNI port to the ring through one-to-one mapping.
One way to avoid this limitation and maximize the number of usable UNI policies is to
encapsulate multiple customer VLANs (coming from the UNI) under a single service
provider VLAN on the ring. Doing so reduces the number of policies required by the LAG
port.

Revision 1 — August 2022 74


Release Notes Skylight element: GT Version 7.9.4

AC-11198 Copper LAG port state changes from Up > Dormant > Down instead of Up >Down
while link is disconnected
When a connected link goes down, the port is expected to switch from Up to Down quickly,
however, the port is switching from Up to Dormant and then to Down.

AC-4316 Cannot create the second VCA when 2 Operator’s TPID are different
When Operator1’s TPID and Operator2’s TPID are different, only 1 VCA will be successfully
created. In this scenario, a second VCA cannot be created. This is a limitation of the VCE/VCA
model and it will result in the following error message: “This platform doesn’t support this
feature”.

AC-4324 Flow-1 automatically switches back to out-of-service mode during upgrade


process
When upgrading the performance element from a pre-7.7 release, if both RFC2544 flows
were enabled, then the “Flow type” field in the “First flow profile settings” will be
automatically reconfigured to the “Out-of-service” state as part of the upgrade process.

ATRC-D15900 LBR message still occurs when MIP and MEP are different VLAN type
Unicast CFM-LBM frames sent to Accedian Demarcation devices are VLAN TPID unaware.

ATRC-D17907 Missing packets on RFC2544 generator layer-3 (2 flows)


With an RFC2544 generator layer-3 that has flow 1 set as QinQ and flow 2 set as no
encapsulation (or QinQ), packets are missing on flow 2 after completing the RFC2544 with
two flows.

ATRC-D17871 Error loading proper page indexing when loading pages via URL/back
Possible error loading proper page indexing when loading WEB pages that contain paged
tables via URL (i.e. back). Some WEB pages contain a table paging feature that displays a
certain number of instances per page within a table. As the user cycles through the different
pages, he will be able to view different instances and the URL will be updated to save this
information. This allows a user to re-load the same view by using the URL (i.e. saving
bookmark, clicking back to reload page, etc.). However, when reloading a web page using
this method, incorrect index offsets may be observed for instances on certain pages.

ATRC-D13944 Generator RFC2544 in-service and monitor operate incorrectly


When an L2PT rule is enabled with forwarding mode set to either pop or replace and the
frame is S-VLAN tagged, the frame is dropped instead of being forwarded.

Revision 1 — August 2022 75


Release Notes Skylight element: GT Version 7.9.4

ATRC-D16848 Filter does not catch IPv6 Extension Headers


Because the frame header fields extraction depth is limited to the first 96 bytes of a frame,
any fields of an IPv6 frame that are beyond the first 96 bytes will not be extracted.
Therefore, they will not be found in the classification key used against an IPv6 filter.
Also, the following IPv6 Next Headers identifying Extension Headers will be skipped.
Therefore, they will not be found in the classification key used against an IPv6 filter:
• Hop-by-Hop options (0)
• Destination options (60)
• Routing header (43)
• Fragment header (44)
• Authentication header (51)
• Mobility header (135)

ATRC-D17233 SNMP IPv6 Filtering and Loopback is not supported


SNMP IPv6 Filtering and Loopback is not supported in this release.

ATRC-D15894 LBR message still occurring when MIP is created with MD level
Unicast CFM-LBM frames sent to Accedian Demarcation devices do not validate the MEG
level in the frame.

ATRC-D15523 DOWN MEP using VCE does not work with un-tag packet
We do not support EVC Client Interface for an untagged MEP on a VCE. We only support
untagged MEPs, if it is a Down MEP on a physical port of the VCE.

ATRC-D15473 The TP-Z-PCP-Mapping does not work properly


An Up MEP defined on the TP-Z port of a VCE, which is defined with frame-type ‘all-to-
one’, does not support the PCP mapping since it necessarily becomes untagged when
egressing TP-A. The PCP value used is then inherited from the CFM object when additional
components are in the transmission path.

ATRC-D15229 DownMEP_VCE: VCE is using TPID but it is affected by changing s-vlan mode
0x9100
The user needs to configure the S-VLAN ethertype located under General system settings,
prior to configuring any VCE or CFM elements. If the user changes this setting after
configuring other elements, they may see some display discrepancies.

Revision 1 — August 2022 76


Release Notes Skylight element: GT Version 7.9.4

ATRC-D07187 LAG Port remains DOWN with LACP, but UP with Link status
When using LACP, if the catchall L2PT rules are enabled, LACP frames will not be handled
correctly to allow LACP to operate correctly.
Workaround: Create LACP rules that also apply to the L2PT configuration.

ATRC-D05982 Limited availability of the OAM Loopback feature


The 802.3ah OAM loopback feature is not functional on the following platforms:
• Skylight element: GT
• Skylight element: GX
• Skylight element: LT
• Skylight element: LX

ATRC-D05907 Reserved value no longer allowed in a Y.1731 configuration


As of firmware version 6.4.2, VLAN ID 4095 is a reserved value and is no longer allowed in
Y.1731 configurations.
If VLAN 4095 was used in a previous firmware version, support in version 6.4.2 will be
maintained through a firmware upgrade. However, any MA/MEG instances using VLAN
4095 cannot be recreated in the event of a deletion.

ATRC-D05812 SNMP returns incorrect values for certain PAA configuration parameters
Polling the following PAA configuration OIDs with SNMP returns “0” instead of the actual
value:
• acdPaaUdpCfgOneWayDelayMax
• acdPaaUdpCfgOneWayDelayThresh
• acdPaaUdpCfgOneWayAvgDelayThresh
• acdPaaUdpCfgOperationMode
• acdPaaUdpCfgPktSize
• acdPaaUdpCfgSamplingPeriod
• acdPaaUdpCfgPeerID

ATRC-D05755 L2PT rules for ESMC also catch other slow protocols
An L2PT rule configured for the ESMC protocol may also catch the following protocol
frames:
• Link OAM
• LAMP

Revision 1 — August 2022 77


Release Notes Skylight element: GT Version 7.9.4

• LACP
If separate L2PT rules are not required for these protocols, no specific intervention is
necessary.
If separate L2PT rules are required for these protocols, assign a higher rule ID to ESMC to
ensure that it does not interfere with other protocols. As a result, other protocol filter rules
will be processed before the ESMC rule.

ATRC-D05720 VC Agent: Changing the local time can cause a disconnection from Vision EMS
Changing the local time on a unit can cause the Vision Collect agent to disconnect from
Vision EMS. The agent will reconnect automatically. No PM data is lost; if a transfer is
interrupted, the data will be retransferred once the connection is restored.

ATRC-D05446 Slight variation in BLUE queue full/empty threshold percentage values


The Web interface for the following products accepts values between 0 and 100 for the
BLUE Queue Full Threshold and BLUE Queue Empty Threshold parameters:
• Skylight element: GT
• Skylight element: GX
• Skylight element: LT
• Skylight element: LX
These values are expressed as percentages. However, this percentage value is
subsequently converted to a binary number and mapped to the range 0-128, as the
underlying register is 7 bits in length.
In most cases, the initial percentage will not correspond to an exact binary value. When this
value is then converted back to a decimal percentage for display purposes, the end result
may differ slightly from what was initially entered.

ATRC-D05432 History CSV files may not all contain the same range of period numbers
The exported history CSV files may not all contain the identical range of period numbers,
depending on when the given history metrics were collected. Enabling multiple categories
of history metrics with many instances requires more processing than history metrics with
fewer categories and instances. Since the history files are processed sequentially, some
exported files may consequently present different period numbers compared to others.
For example, the CFM DMM file may show periods 16-30, whereas the CFM SLM file may
show periods 17-31, since it was processed afterwards. The reason for this variation is that
new periods are included in the CSV file as soon as they become available.
This is the expected behavior. There is no period number synchronization between history
categories. Note that all periods are exported in the CSV files and no data is lost.

Revision 1 — August 2022 78


Release Notes Skylight element: GT Version 7.9.4

ATRC-D05382 CoS Mapping: Yellow PCP Out is not mapped to a queue


The following products use CoS mapping to define the internal CoS that service frames will
use in the unit.
• Skylight element: GT
• Skylight element: GX
• Skylight element: LT
• Skylight element: LX
However, the pre-marking color parameter (set to Green or Yellow) is disregarded when
mapping a flow to a traffic queue. The system’s internal CoS always uses the configured
Green PCP value to map a flow to a queue, regardless of whether the pre-marking is set to
Green or Yellow.

ATRC-D04263 Web Interface: VLAN ID value not properly validated when creating a VID set
The VLAN ID value is not properly validated when creating a VID set in the Web Interface.
Entries outside the valid range (0–4095) are accepted, as well as character strings; however,
the resulting VID set instance is empty with no VLAN ID assigned.
This issue only concerns the Web Interface; the CLI performs the proper validation and
rejects invalid entries as expected.
The following products and firmware versions are affected:

Product Name Firmware Versions

TE-x Performance Element 5.1 – 6.4.3

GT/GT-S Performance Element, now 6.3 – 7.3


Skylight element: GT/GT-S (7.9) 7.9

GT-Q/GT-QE Performance Element 7.1.1 – 7.3

GX/GX-S Performance Element, now 6.3 – 7.3


Skylight element: GX/GX-S (7.9) 7.9

10GE CE/NE Performance Element 5.0 – 6.3

LT/LT-S Performance Element, now 6.3 – 7.3


Skylight element: LT/LT-S (7.9) 7.9

Skylight element: LX-S 7.9

FS/FS 10G Performance Element 1.0 – 1.1

Revision 1 — August 2022 79


Release Notes Skylight element: GT Version 7.9.4

ATRC-D04040 Syslog error message at login after configuring RADIUS


After a first-time RADIUS configuration, a false syslog error may be generated due to start-
up conditions when the user logs in.
The syslog message is as follows:
Jan 1 00:19:13 C074-0010 dropbear[1620]: rc_get_seqnbr: fscanf
failure: /tmp/radius.seq
This message has no consequence and can be ignored.

ATRC-D03949 Modified syntax for CLI command “bandwidth-generator add”


Starting in firmware version 6.4, the CLI command bandwidth-generator add is used to
configure regulators and bandwidth sharing envelopes.
Previous syntax (before 6.4):
bandwidth-regulator add <regulator-name> …
New syntax (6.4 and later):
bandwidth-regulator add regulator <regulator-name> …
or
bandwidth-regulator add envelope <envelope-name> …
Consequently, the word regulator is reserved as of firmware version 6.4 and cannot be used
as a regulator name, although the former syntax is still supported for backward
compatibility.
These changes are illustrated in the following examples.
Preferred syntax:
bandwidth-regulator add regulator regulator1 cir 20000 …
Allowed (for backward compatibility):
bandwidth-regulator add regulator1 cir 20000 …
Not allowed (triggers an error message):
bandwidth-regulator add regulator cir 20000 …
(invalid parameter value)

ATRC-D03939 Maximum number of complex rules for ERP traffic


For any unit that supports G.8032, the system automatically creates a default Layer-2 filter
traffic policy (used for the ring pass-through traffic) whenever a LAG port is configured for
ERP.
Since this default policy consumes one of the unit’s available complex rules (i.e., using a
Layer-2 or IPv4 filters), the number of complex rules available to users on that LAG port is
reduced by 1. This situation has no impact on other ports.

Revision 1 — August 2022 80


Release Notes Skylight element: GT Version 7.9.4

ATRC-D02695 Timestamps of report periods are not always contiguous


The data collected by Vision EMS in high-resolution mode can occasionally show
consecutive records with timestamps that are not contiguous.
Be aware of the following limitations:
• When data is collected in high-resolution (1 second) mode, two consecutive
measurements can sometimes present the same timestamp, or show a gap
between the timestamps. This is caused by rounding the time value to a
granularity of 1 second.
Please note that in this case, no periods or measurements are lost, i.e. all periods
are consecutive, and none are missing.
• There can be a timestamp gap or overlap when the unit is first synchronized by
NTP, PTP or GPS. As the Flow meter may be acquiring data before the
synchronization is complete, a time adjustment could affect the timestamps. No
periods or measurements are lost.
Inconsistencies may also surface in the timestamps collected before a system reboot when
compared to those collected after the reboot.

ATRC-D02648 New behavior when re-enabling CFM-PL instances


In firmware version 6.3.1, the CFM packet loss (PL) behavior has been modified as follows:
Previous behavior (before 6.3.1): When a packet loss (PL) instance is re-enabled after being
disabled, the current period results contain the last values from the point at which the
instance was disabled.
New behavior (6.3.1. and later): When a packet loss (PL) instance is re-enabled after being
disabled, the current period results are cleared, and measurements begin from 0.

ATRC-D02057 Syslog: Entries are sometimes not displayed in the system log
When a large number of events occur at the same time (e.g. raising or clearing hundreds of
alarms simultaneously), some entries may be absent from the syslog. Missing entries do
not imply that the corresponding events/actions were not properly executed.
For example, in the case of alarm storms, although syslog messages for some status
changes are not displayed, all the alarms are updated to the correct status and the
corresponding SNMP traps are reported.

ATRC-7830 RFC-2544 test suite: Report displays incorrect unit identifier information
When running the RFC-2544 test suite after modifying the unit identifier (System ▶ DNS ▶
host name), the generated report contains the previous unit identifier.

Revision 1 — August 2022 81


Release Notes Skylight element: GT Version 7.9.4

ATRC-B10797 Firmware upgrade considerations pertaining to history buckets


Since firmware version 6.3.1, several software modifications have optimized how the
history data is handled and stored to flash memory. Before proceeding with the firmware
upgrade, take the following precautions:
• To prevent any loss of history data, ensure that all data has been transferred to
the file server.
• Be aware of certain side-effects caused by these optimizations on systems on
which the History Buckets feature is enabled.
Upgrading from any pre-6.3.1 version to 6.3.1. and later:

• All history data present on the flash memory is deleted during the upgrade
process.
Upgrading from version 6.3.1 to 6.4.2:

• No history data is deleted during the upgrade process.


Upgrading from version 6.3.1 or 6.4.2 to any later version:

• All history data present on the flash memory is deleted during the upgrade
process.
Upgrading from version 6.4.2.1 to 7.0:

• All history data present on the flash memory for the Policy, Regulator, Shaper,
SOAM DMM and SOAM PL is deleted during the upgrade process.
Upgrading from version 6.4.2.1 to 7.2:

• All history data present on the flash memory for the Policy, Regulator, Shaper,
SOAM DMM and SOAM PL is deleted during the upgrade process.

ATRC-7572 Y.1564 one-way flows must be received on the same SAT server port
If one-way test flows from multiple Y.1564 generators are sent to a SAT server (i.e. a remote
unit), all flows must terminate on the same physical port. For example, terminating eight
flows on one port and eight other flows on a different port is not supported.

ATRC-7028 No VLAN information in LLDP frames


LLDP frames sent by the unit only contain the interfaces’ IP address and index values.
Information on the interfaces’ VLAN settings is not available at this time.

ATRC-6906 RFC-2544 monitors are not independent


When using both RFC-2544 monitors in bypass mode to monitor Layer-2 and Layer-3 test
traffic flows, both monitors will report the Layer-3 flow statistics. If the monitor configured
for Layer-2 is disabled, the other monitor (Layer-3) does not report any statistics.

Revision 1 — August 2022 82


Release Notes Skylight element: GT Version 7.9.4

ATRC-6869 Obtaining the UTC offset from the PTP master is not supported
The option to obtain the UTC offset from the PTP master is not yet supported. As such, the
offset provided in the announce messages from the PTP master are not applied to the time
information on the unit. Only the locally defined UTC offset can be used.

ATRC-6846 IPv6 router-advertised addresses are lost when configuring other addresses
After an interface has configured itself with one or several addresses from IPv6 router
advertisements, configuring any other address (whether static or DHCP) will flush the
router-advertised addresses.
This is the intended implementation, since configuring a static IP or enabling DHCP
supersedes the router advertisements.

ATRC-6758 Higher number of Y.1731 frames sent over a period


The number of Y.1731 sample frames (CCM, DMM or SLM) sent over a period can be slightly
higher than expected.
For example, if SLM is configured with an interval of 100 ms and a period of 60 seconds, it
is possible that 601 or 602 samples will be sent during the period instead of 600. This is
caused by a rounding issue related to timer division.
This issue does not lead to packet loss or inaccurate delay results; it is merely a variation of
the number of samples sent over a period.

ATRC-6672 Plug & Go ring protection from customer beacon


When a new unit is added to a G.8032 ERP ring and is in the process of being provisioned
using the Plug & Go feature, it is important to ensure that no foreign beacons enter the ring
from the UNI side (e.g. from a customer). Taking this measure prevents the new ring unit
from being provisioned by the wrong beacon.

ATRC-6604 Web interface may be slow with Mozilla Firefox version 14.0.1 to 22
When using the Mozilla Firefox Web browser version 14.0.1 to 22 to manage the unit, the
response time can sometimes increase, which makes the Web interface slow to operate.
Workaround: Use Firefox version 23 or higher.

ATRC-6509 LAG-Protection: ETH-CSF cannot validate port state on LACP-based UNI links
If enabled, ETH-CSF cannot validate the link status of an LACP-based protected UNI link.
Under such circumstances, the remote fault cannot be propagated. Since ETH-CSF is based
on link-status and LACP is based on signaling, it is currently impossible to indicate to CSF
that the link is logically down, yet still physically up.

Revision 1 — August 2022 83


Release Notes Skylight element: GT Version 7.9.4

ATRC-6425 CLI traceroute command does not support all listed options
The CLI traceroute command does not support the following options:
• -q (number of queries)
• -s (source IP address)
• -g (gateway)

ATRC-6132 VSP reflector responds to invalid MAC addresses on the management port
The V-NID reflector functionality is only intended for use on traffic ports, not on out-of-
band management ports. However, the out-of-band management port will reflect any
ETH-VSP frames it receives. While traffic ports only reflect VSP frames that match the
port’s specific MAC address, the out-of-band management port will reflect VSP frames that
match the MAC address belonging to any of the unit’s ports (MAC range).

ATRC-5790 EVC Mapping: “Preserve VLAN - New CFI/PCP” limitations


When setting EVC Mapping to “Preserve VLAN - New CFI/PCP”, the following limitations
should be taken into consideration:
• DSCP/IP Precedence information is not extracted from triple-tagged frames.
• DSCP/ IP Precedence information is not extracted from 802.2 SNAP/LLC frames.
• DSCP/ IP Precedence/PCP information is not extracted from S-VLAN (0x9100)
tagged frames, unless 0x9100 is set globally as the default S-VLAN Ethertype.
This EVC mapping action can corrupt untagged frames. Therefore, a filter matching at least
one VLAN must be used to ensure the classified frames are tagged.

ATRC-5646 EVC mapping actions that modify VLAN tags must not be used with untagged
traffic
EVC mapping actions that involve replacing or modifying a VLAN tag should not be used if
the traffic is untagged. These EVC mapping actions are:
• Replace
• Pop & Replace
• Preserve VLAN – New CFI/PCP
Performing VLAN modifications on untagged traffic could result in altering the frames.
There is no traffic policy validation to enforce the presence of a VLAN filter with these EVC
mapping actions. You must therefore ensure that any policy using these EVC mapping
actions is configured with a VLAN filter.

ATRC-5474 Frame count statistics may be inconsistent if SLM is disabled in mid-period


If an SLM instance is disabled in the middle of a reference period, the ETH-SLM and
ETH-SLR frame counts shown in the MEP statistics may not be consistent with those

Revision 1 — August 2022 84


Release Notes Skylight element: GT Version 7.9.4

shown in the SLM statistics. This is normal, as the information may not have been refreshed
at the very moment when the SLM instance was disabled.
This behavior is a normal consequence of disabling the SLM instance during a period and is
by design. SLM functions as expected in continuous operation.

ATRC-5364 CPU-destined ingress traffic can be processed on an LACP link while not in the
collecting/distributing state
When using LACP status-based protection, CPU-destined traffic received on a port can be
processed by the software even when the local (actor) LACP link status is not in the
collecting/distributing state. This situation applies to CFM traffic (LBM, LTM, DMM, CCM,
etc.), PAA traffic and L2PT traffic.

ATRC-5254 Web session does not time out if automatic refresh is enabled
The active session of the Web interface will never time out if automatic refresh is enabled
in a page.

ATRC-5197 ARP Requests are sent out on a port when interface is disabled
Many ARP requests are sent out on a port even if the interface associated with the port is
disabled.

ATRC-5196 “cfm show statistics” CLI command shows incorrect RDI and CCM sequence errors
This CLI command does not accurately report the count of CCM sequence errors. This
information can be displayed using the cfm show mep statistics command.

ATRC-5107 Users without “Policy” permissions can clear policy statistics in the Web interface
Users are currently able to clear the Policy statistics in the Web interface (but not in the
CLI), regardless of their assigned permission settings.

ATRC-4560 CLI: CFM naming convention (MEP, Pkt-loss, DMM)


When assigning a CFM name to an instance in the GUI, the name must not be composed
solely of digits; CFM names must always include at least one letter. If the name contains
only digits, the CLI interprets the name as an instance index.

ATRC-4076 SCP -z option not working with certain servers


Certain SSH servers, such as Solaris and several Linux enterprise versions, do not support
the SCP -z option to specify the username. Once the SCP fails, FTP no longer functions since
it uses the same process. The CPU must be restarted for FTP to function.

Revision 1 — August 2022 85


Release Notes Skylight element: GT Version 7.9.4

This issue is related to how the SSHd server is configured. Servers are usually configured to
use PAM (Pluggable Authentication Modules) for account and session management. SSHd
can also rely on PAM for authentication; PAM then executes its authentication scheme
based on its configuration for that login method (for example: /etc/pam.d/sshd).
Configuring Response Authentication:
• With OpenSSH, ChallengeResponseAuthentication in /etc/ssh/sshd_config should
be set to No.
• On Solaris, PAMAuthenticationViaKBDInt in /etc/sshd_config should be set to No.
Alternate Solutions:
• Change the PAM configuration for SSHd (expert).
• Use a public key authentication.
Modification Procedure:
• Solaris:
o Log in with administrative privileges.
o Edit file /etc/ssh/sshd_config to set PAMAuthenticationViaKBDInt to No.
o Save file and exit.
o Restart service: svcadm restart network/ssh.
• Ubuntu Linux (OpenSSH):
o Log in with administrative privileges.
o Edit file /etc/ssh/sshd_config to set ChallengeResponseAuthentication to No.
o Save file and exit.
o Restart service: sudo service ssh restart.

ATRC-3533 SyncE is not supported with copper SFP


Copper SFPs use the internal 25 MHz oscillator instead of the SyncE recovered clock.
Consequently, SyncE is not supported for copper SFPs.

ATRC-3285 Web browser refresh deletes the current search filter


Using the browser Refresh command (F5 or Ctrl+R) does not only refresh the page values,
it also reloads the page completely. Doing so eliminates any search filters that were entered.
This behavior is considered normal.

7.4 MIB Changes


None

Revision 1 — August 2022 86


Release Notes Skylight element: GT Version 7.9.4

8. Firmware Version 7.8.3_20905 (2019-08-16)

8.1 New Features and Enhancements

AC-7119 Performance GT and GX performance element flash refresh robustness


improvement
This feature extends the normal retention time of software stored in flash beyond the
hardware specifications of the flash components by periodically refreshing the stored data
on the GT and GX SkyLIGHT performance elements.

AC-8822 New “Dormant” status in LAG


A new status called “Dormant” is now available on LAG ports configured with Link-Status
protection mode. This status means the port is enabled and a signal is detected but the port
cannot forward user-traffic, as it is in a “stand-by” state.

AC-9070 Performance element software supports IPv6 addresses on the pmcollect


command
With this new feature, customers can now configure streaming when the performance
element is managed in an IPv6 only network. In addition, the customer can stream to IPv6
addresses using performance elements, even in a multi-product solution environment.

AC-9076 Include session name in DMM and PL in CSV


A session name was added to the DMM and PL metrics in the CSV file (History Buckets)
and the streaming data (PM Collect). Furthermore, the MD name, MA/MEG name and MEP
ID, along with their indices were added to the SLM CSV (History Buckets) and streaming
data (PM Collect) as well. This will ensure the performance metrics reporting is consistent
across all Accedian SkyLIGHT product lines.

AC-11386 New Logo and design for Performance elements


The SkyLIGHT Performance elements now display new logo, fonts and colors in the WEBUI.

Revision 1 — August 2022 87


Release Notes Skylight element: GT Version 7.9.4

8.2 Addressed Issues

AC-10194 ACD-ALARM-MIB changes in R7.7


The object “acdAlarmCfgNumberExt” was added in R7.7 and appeared in the wrong order
in the OIDs list in the trap (ACD-ALARM-MIB.mib). This issue has been fixed and the object
“acdAlarmCfgNumberExt” now appears at the end of the existing OIDs.

AC-11172 CFI/DEI configuration field allows out of range values definition


The CFI/DEI is expected to be 0 or 1; however, under certain settings, it was discovered that
it was possible to define each value between 0 and 9. This issue has been fixed and is now
set to 0 or 1 only.

AC-11632 Legacy string-based MA/MEG name support


This new feature provides customers with legacy string-based MA/MEG name support to
fix incompatibility between 7.1.x and 7.8.x.

AC-11668 Configuration export does not include the updated information of the user
When updating user information (e.g. first name, last name, phone number) then
performing configuration export, this information was not being updated. This issue has
been fixed and the information is now properly updated in the configuration file and device.

Revision 1 — August 2022 88


Release Notes Skylight element: GT Version 7.9.4

9. Firmware Version 7.8.2.1_20416 (2019-06-04)

9.1 New Features and Enhancements


None.

9.2 Addressed Issues

AC-10194 ACD-ALARM-MIB changes in R7.7


The object “acdAlarmCfgNumberExt” was added in R7.7 and appeared in the wrong order
in the OIDs list in the trap (ACD-ALARM-MIB.mib). This issue has been fixed and the object
“acdAlarmCfgNumberExt” now appears at the end of the existing OIDs.

Revision 1 — August 2022 89


Release Notes Skylight element: GT Version 7.9.4

10. Firmware Version 7.8.2_20146 (2019-05-10)

10.1 New Features and Enhancements

AC-8817 Independent Syslog Levels


This new feature provides customers with a way to select different syslog levels on the
local and remote syslog server.

AC-7666 Showing IPv6 addresses in Link Layer Discovery Protocol (LLDP) Neighbors
information
LLDP Neighbors information now shows IPv6 management addresses (in addition to IPv4
management addresses).

10.2 Addressed Issues

ATRC-D07991 UNI port flapping issue when FP and CSF are enabled on multiple UNI ports
When Fault Propagation (FP) and Client Signal Fail (CSF) are enabled on a combo port (port
9 to 12) and media selection is set to auto, certain events can cause the UNI ports to start
flapping. This issue has been fixed.

AC-6183 LACP Revertive timer operation leads to unreliable switching


With LAG set to 2 secs/revertive, port-2 remains active instead of going back to standby
when port-1 is brought up after being down (unexpected behavior). With LAG set to 60
secs/revertive, port-2 goes back to standby when port-1 is brought up after being down
(expected behavior). This issue has been fixed.

AC-6241 RFC-2544 test suite with frames size bigger than 256 bytes generates low
throughput results
Low throughput results are generated when running an RFC-2544 test suite (working rate
layer-2) with a maximum rate set to 6 Gbps and frame size that exceeds 256 bytes. This
issue has been fixed.

AC-7466 Y.1564 test fails, showing “ERROR: Mismatch between port MTU configuration
and frame size”
The Y.1564 test will fail if there is a mismatch between the port MTU configuration and the
frame size when the frame size type is initially set to “Fixed” and then changed to “EMIX”,
even if the frame size is also reset to match the MTU configuration. This issue has been
fixed.

Revision 1 — August 2022 90


Release Notes Skylight element: GT Version 7.9.4

AC-7494 RFC2544 test suite fails when using same value for maximum and minimum rate
When performing a RFC-2544 test suite using similar maximum and minimum rate, the test
will take a very long time to complete and will fail when it finally does complete. This issue
has been fixed.

AC-7621 RFC-2544 test fails, showing “ERROR: Mismatch between port MTU configuration
and frame size”
The RFC-2544 test will fail if there is a mismatch between the port MTU configuration and
the frame size when the frame size type is initially set to “Fixed” and then changed to
“EMIX”, even if the frame size is also reset to match the MTU configuration. This issue has
been fixed.

AC-7659 User permissions for Y.1564 not allowing parameters to be edited


After setting user permission for Y.1564, the following parameters are greyed out and
cannot be edited:
• Frame Size Type
• Frame Transfer Delay Type
• Frame Delay Variation Type
This issue has been fixed.

AC-7940 Ethertype value in RFC2544 layer-2 always 0x8902 even if a custom Ethertype is
defined
This parameter (Ethertype) is now deprecated and no longer needed. Its syntax remains
valid for backward compatibility and its value is set automatically based on the value of
packet-type. For example: 0x0800 for Layer-3, 0x8902 for Layer-2, 0x88FC for Layer-2
Accedian or Layer-2 generic. This issue has been fixed.

AC-7941 Layer-2 filter set for Ethertype 0x88fc traffic catches Ethertype 0x8902 traffic
This issue occurs because Layer-2 Ethertype 0x88fc and 0x8902 are filtered as the same
value. This issue has been fixed.

AC-8966 Synthetic Loss Measurement (SLM) streaming to SkyLIGHT Director Vision is not
working
When the SLM index is manually configured, starting at a high number (11 to 18, 21 to 38),
streaming to SkyLIGHT Director Vision does not work (no SLM csv file will be produced).
This issue has been fixed.

Revision 1 — August 2022 91


Release Notes Skylight element: GT Version 7.9.4

AC-9126 RFC-2544 test results not showing the exact bandwidth rate
The test suite results throughput display is no longer the integer value. As an example, it
could show 99.999 Mbps instead of the expected 100 Mbps. This issue has been fixed.

AC-9302 SFP statistics data not collected when port-1 is not present
No history data (SFP statistics) is collected when history data is enabled (with filling for
SFP, PORT and System Health enabled as well) if port-1 is not present but other ports are.
This issue has been fixed.

AC-9552 Syntax change to “bandwidth regulator add” command prevents commissioning


using third party orchestrators
A change in the “bandwidth regulator add” command syntax causes “command not
found” error message and prevents the user from being able to configure bandwidth
regulators. This issue has been fixed.

Revision 1 — August 2022 92


Release Notes Skylight element: GT Version 7.9.4

11. Firmware Version 7.8.1_19220 (2018-12-21)

11.1 New Features and Enhancements

AC-3859 Y1564 Burst SLA Test on GT, GX and LT Performance Elements


This feature introduces CBS Burst SLA testing in Y.1564 on the Performance Element.

AC-4406 Group Sub-Privileges (CLI and Web Interface)


This release introduces the ability to have more granular level user permissions. Specific
sub-privileges will be added to the current permission group in order to manage the user’s
privileges in a more granular manner. The administrator will therefore be able to assign or
revoke specific sub-privileges within a permission group.

Permission-Group Sub-privileges Description


Port Internal loopback Permission to configure internal loopback
Session reboot Permission to reboot device
Firmware upgrade Permission to upgrade firmware
rollback Permission to rollback firmware
Config import Permission to import configuration file
export Permission to export configuration file
rollback Permission to rollback system configuration
factory Permission to reset default system
configuration

AC-5817 Back-to-back testing RFC2544 default changed to disabled


To prevent service impacting issues due to human errors from happening, back-to-back
testing is now disabled by default in the RFC2544 test suite.

AC-5818 Web UI warning messages


Warning messages have been added in this release in order to prevent service impacting
issues due to human errors. A warning message will be displayed when a user tries:
• Changing any parameter from an active policy
• Changing any parameter from an in-use filter
• Changing VIDs from an in-use VID set

Revision 1 — August 2022 93


Release Notes Skylight element: GT Version 7.9.4

• Changing any parameter from VLAN Settings and/or VLAN in VLAN Settings
(Ethertype, Priority and VLAN ID) of an interface
• Disabling Regular port or LAG port
• Deleting an interface
• Perform OAM Loopbacks (Loopback Enable box checked in OAM Loopback)
• Set loopback with Drop Opposite Traffic enabled

11.1.1 Robustness Improvements

AC-5049 Cross-site Request Forgery Prevention


This feature is introduced in this release using a two-token approach. Two tokens will be
sent via cookies and both will be sent back to the server on a request. If the two tokens are
concordant, then the request will be considered valid.

AC-5050 Web Stored Scripting


This feature is introduced to prevent users from inputting html control characters in text
fields, resulting in a script being executed by the browser when that field is added to a drop-
down menu.

11.2 Addressed Issues


ATRC-D18284 Incorrect prefix for host route in IPv6
The host route in IPv6 has a prefix of zero instead of 128. This issue has been fixed.

AC-5256 EVC and CoS parameters in CSV file do not match CLI/WEB UI
The following fields in the CSV file do not match the configuration that can be seen in the
CLI and WEB UI:
• EVC Mapping Encapsulation
• COS Mapping Choice 1 Profile
• COS Mapping Choice 1 Regulator
• COS Mapping Choice 2 Profile
• Mapping Choice 2 Regulator
This issue has been fixed.

ATRC-D08107 Lengthy RFC-2544 tests report incorrect Rx rate


The RFC-2544 test measures the Rx rate using a 32-bit counter. However, an incorrect Rx
rate could be reported during lengthy testing due to the 32-bit counter wrapping around.
This issue has been fixed.

Revision 1 — August 2022 94


Release Notes Skylight element: GT Version 7.9.4

12. Firmware Version 7.8_18628 (2018-10-31)

12.1 New Features and Enhancements

AC-3858 Ability to advertise to a list of inventory nodes


This release introduces the support for a list of advertisement IP addresses per interface.
Customers can have a minimum of 1 IP address per interface and a maximum of 2.

AC-3860 Using ACL to deny or allow ICMP packets from specific MAC/IP addresses
This release introduces the capability to drop ICMP frames from the network management
interface by using access control lists (ACLs).

AC-3862 Dual MAC address for GT performance element


This new feature provides the ability to manage the device remotely by allowing a single
interface (Auxiliary MAC) to be created and assigned a different MAC address than the MAC
address of the Port to which it is assigned.
Limitations:

• Beaconing is not supported on the interface where Auxiliary MAC is enabled.


• SAT tests targeting the interface where the Auxiliary MAC is enabled is not intended
to be used.
• If more than one interface is on the same subnet, the OS will choose which interface
to use based on its routing table. This has implications for all Layer-3 applications,
NTP, Radius, SNMP, TWAMP, PAA-L3, etc.
• Creation of an interface where the Auxiliary MAC is enabled is not possible if LAG is
enabled on the port.
• Enabling the use of the Auxiliary MAC address is not supported on interface type
‘Bridge’.
• Support of the Auto interface and Plug and Go on this interface is not supported.
• Assigning an interface to CFM for the purpose of creating a double-tagged SOAM
frame is not supported on the interface in which the Auxiliary-MAC is enabled.

AC-4327 Exclude VLAN tags from RFC-2544 test suite frame size
This release introduces the capability to exclude the VLAN tag size from the RFC-2544 test
suite configuration. When excluding the VLAN tag size, the frame length is increased by
the size of the VLAN tag header(s) being added to the frame.

Revision 1 — August 2022 95


Release Notes Skylight element: GT Version 7.9.4

AC-4341 Layer-2 filter for IPv6 Ethertype and DSCP


Layer-2 filter for IPv6 Ethertype and DSCP is now supported.

12.1.1 Robustness Improvements

AC-3865 HTTP port redirect


It is now possible to disable HTTP port redirection for security reason.

Note: Web browser can restrict the usage of certain reserved ports for security reason. It
is up to the user to select a valid port.

AC-3866 Web header change


We added new secure information in http header, such as secure flag for session ID in the
cookie.

AC-3867 Vulnerabilities when Dropbear SSH Server version is lower than 2016.72
LT, GT and GX performance elements are affected by the following vulnerabilities when
Dropbear version is lower than 2016.72:
• CVE-2016-7406
• CVE-2016-7407
• CVE-2016-7408
• CVE-2016-7409
This issue has been addressed by implementing Dropbear Version 2018.76.
• Supported HMAC algorithms:
o SHA2_256
o SHA2_512
• Supported KEX algorithms:
o curve25519-sha256
o curve25519-sha256@libssh.org
o diffie-hellman-group14-sha256
o diffie-hellman-group14-sha1
o kexguess2@matt.ucc.asn.au
• Supported Ciphers:
o aes128-ctr
o aes256-ctr

Revision 1 — August 2022 96


Release Notes Skylight element: GT Version 7.9.4

AC-3868 Update SSL library


The SSL library was updated and supports latest secured ciphers.

12.2 Addressed Issues

AC-4309 Multiple TWAMP generator sessions can cause less packets to be sent
When running multiple TWAMP sessions, it may occur that less packets than expected in
a period will be sent. This issue has been fixed.

AC-4325 SDVM csv files having inconsistent time results depending on product and
grouping period
The csv files should be generated based on the grouping period, streaming period and
device, since different devices and streaming periods will have different time results. This
issue has been fixed.

AC-4340 Layer-2 rate generator allows Layer-1 rate that are higher than 1G
As it is not possible to send a test Layer-2 rate that exceeds 761 Mbps (when using 64-byte
frames) on a 1G line, users should not be allowed to configure a 800 Mbps test Layer-2 rate
(on a 1G line). This issue has been fixed.

AC-4344 Expired certificates prevent login into NIDs


User is unable to log into NIDs using SDVM reverse proxy due to expired certificates. This
issue has been fixed.

AC-4347 ERP Ring - Management bridge leaking into the protected segment causing a
broadcast storm
Broadcast packets are forwarded across a bridge between a traffic port and the
Management port even though the port is blocked due to a “Manual Switch (MS)”. This
issue has been fixed.

AC-4357 Inconsistency in webs port settings


There is an inconsistency in the minimum and maximum values that can be set for the webs
port. This issue has been corrected. The minimum value is 1024 and the maximum is value
65535. This issue has been fixed.

AC-4500 OAM loopback persistency not working in the Web interface


It is not possible to enable the loopback persistency checkbox as it is always grayed-out.
This issue has been fixed.

Revision 1 — August 2022 97


Release Notes Skylight element: GT Version 7.9.4

13. Firmware Version 7.7_17244 (2018-06-22)

13.1 New Features and Enhancements

ATRC-E03676 Netconf/Yang
Release 7.7 introduces the Netconf/Yang feature. This feature provides service providers
the ability to perform basic service provisioning and receive notifications by configuring a
Netconf agent. This feature supports:
• Port configuration
• Port statistics
• Traffic policies
• Traffic filters
• System configuration
• System alarms
• Traffic regulators
• Traffic mapping
• Traffic shaping
• Traffic vlan
• Traffic monitors
• Traffic configuration
• Netconf: State & Timeout
• Notification for Alarms
• SOAM CFM
• System agent
• System session
• SOAM TWAMP
• VCE/VCA
• PAA
• SOAM SA
• Plug & go
ATRC-B20549 System Monitoring
System Monitor allows for the monitoring, logging and alerting of system resources (CPU,
Memory and Disk Usage) and Network statistics. This feature can be enabled or disabled.
Three Probes can be configured when System Monitor is enabled:

Revision 1 — August 2022 98


Release Notes Skylight element: GT Version 7.9.4

System Probe, to measure and report on CPU and memory usage as well as number of top-
level processes.
• Disk Probe, to measure and report on disk usage.
• Network Probe, to report statistics (packets sent/received, bytes sent/received)
about currently active network devices. The Network Probe can only be used in
• Debug mode and does not have any threshold limits.

ATRC-B20203 In-field Support for 1G10G


In-field Support provides the capability to generate and export system health reports. A
flight recorder will record all events and gather information from the system and store a
single concatenated file for troubleshooting purposes.

ATRC-B20557 VCE/VCA improvements


Release 7.7 introduces a refactored VCE/VCA edit method to avoid duplication and improve
speed.

ATRC-B14759 User Experience Improvements


In Release 7.7, next and previous buttons have been incorporated in the configuration panel
of the policy so users can navigate more conveniently in the configurations.

ATRC-B20559 User Experience Improvements


This release introduces the following improvements to better automate ISTT and make it
more user friendly:
Back-end validation (for WEB+CLI) to assure a generator can be enabled with only 1 flow
set to in service throughput testing. The user can still enable 2 flows (1 in-service and 1 out-
of-service) should they decide to.
• Include a note in the help file to explain the one-way sync parameters as they are
utilized when synchronized.
• Implement a simple “save” option in the monitor results page.

ATRC-B20396 Additional Statistics for PM Collect and History Bucket


In addition to the currently available statistics, users can now receive data on SFP power
levels and system health (CPU and Memory statistics). These statistics are reported via PM
Collect or the locally stored history files may be transferred via one of the supported
protocols.

Revision 1 — August 2022 99


Release Notes Skylight element: GT Version 7.9.4

ATRC-E03677 Remove session writelock


The new implementation removes the manual process to take and release the session
writelock. Instead of session writelock, a mutex has been added forcing the command
execution serialization. Each configuration interface instances can send their commands
and do not cause the other configuration interfaces instances to fail their execution. The
session writelock commands are still available in order to be backward compatible with
existing integration and the writelock access is always granted.

13.2 Addressed Issues

ATRC-D17296 CPU usage history graph will not show on Firefox web browser
The CPU usage history graph is not displayed when the Firefox web browser is used to
access a performance element Web GUI.

ATRC-D17292 No error message when editing the VCE_Tunnel with an invalid configuration
through CLI
When a user tries to specify the physical ID, the request will be ignored as the port is
internal and is set to an internal value. No error message will indicate that behavior.

ATRC-D17490 LTS 10G ports: auto-nego command should be removed from the CLI
The LTS 10G ports do not have the auto nego option in the web interface but this was
present in the CLI. This command has been removed because it created confusion.

ATRC-D17539 Fan aging test timeout to be increased to 300 seconds instead of 60 seconds
The new fan test timeout period has been increased to 300 seconds from 60 seconds, as
per specs of fan.

ATRC-D17578 INNER filtering mode actually filters on DUAL tag only


The help has been modified to indicate more clearly that:
• The VLAN level for each Traffic Port must be configured for use with one or two
VLAN tags in the VLAN filters.
• When the VLAN level setting is configured as ‘Outer’ (default), then the VLAN
filter is matched against the outer VLAN of incoming frames. With this option, the
outer VLAN ID can only be used once per port in the VID sets.
• When the VLAN level setting is configured as ‘Inner’, then the VLAN filter is
matched against both outer and inner VLANs of incoming frames. With this
option, the inner VLAN ID can only be used once per port in the VID sets.
• In all cases, the VLAN type must match the filters.

Revision 1 — August 2022 100


Release Notes Skylight element: GT Version 7.9.4

ATRC-D17686 Edit MA/MEG attributes cause RMEP object to be deleted


Input format [x-y] causes the MEPID list to be modified, and the Remote MEP objects as
well as any PM objects associated with the MEP to be deleted without warning.

ATRC-D17661 LTS 7.1.1.3 Regulator showing no statistics


Since regulators take address as 0 for error or disabled regulator, pattern idx may be
returned the same when regulators sets have a different mapping.

ATRC-D17162 Redesign the loopback drop opposite traffic to prevent accidental usage
The default value has been changed from 0 to 30 min and timeout value range is now 0-
1440 min. If Drop-opposite traffic is Enabled user will receive a pop-up message: “Drop-
opposite traffic will drop all the traffic entering the device on the opposite port.” If Loopback
is Enable another message will show: “Loopback is service affecting. Are you OK?”

Note: These messages apply to web ONLY.

ATRC-D17379 Indirect Linux access using CLI commands


Some CLI commands can be used to access Linux folders and files.

ATRC-D18038 RFC-2544 L3 flowtype In-service Monitor fails to detect if the Frame has a TTL less
than 255
If the unit is reconfigured to have a TTL value of 254 or lower the Monitor does not count
these incoming frames any longer.

Revision 1 — August 2022 101


Release Notes Skylight element: GT Version 7.9.4

14. Firmware Version 7.6_15744 (2018-02-02)

14.1 New Features and Enhancements

ATRC-E03674 IPv6 Two-Way Active Measurement Protocol (TWAMP) generator and reflector
1G/10G Release 7.6 introduces IPv6 support for TWAMP Lite Generator and TWAMP
Reflector, similar to the current IPv4 TWAMP support on the performance elements.

ATRC-E03673 IPv6 filtering for policy and loopback


This release introduces the capability of setting up IPv6 filters (in addition to existing Layer-
2 and IPv4 filters) for use with loopbacks or traffic policies. IPv6 filtering allows service
providers to classify traffic using IPv6 addresses in order to provide class of service to their
customers using IPv6.

ATRC-E03466 Advertisement Inventory Alarms


The following Advertisement Inventory Alarms have been introduced in this release:
• 18.0001.01 Inventory entries list is almost full (minor alarm). The default value for
the Inventory warning-threshold is 3000 and can be set to any value between
3000 and 3999. This alarm is raised when the inventory NIDs reach 75% of the
number of maximum entries that we support.
• 18.0001.02 Inventory entries list is full (major alarm). This alarm is raised when
the inventory NIDs reach 100% of the number of maximum entries that we
support.

ATRC-E03729 Keyboard logging


The CLI Command Logger has been implemented in this release as a troubleshooting tool.
It is enabled by default and it will log CLI input commands from any CLI instances. The
logged information will also show the username and IP address of a session when it starts
or ends.
This feature supports up to 4 log files and the maximum log file size for LT, GT and GX
platforms is 100KB.

ATRC-B20073 CFM-MIP: SOAM Resource Manager enhancements


The total number of MP instances supported has been increased to 2000 (1000 MEPs and
1000 MIPs), doubling the total number of MP instances supported in Release 7.5.

Revision 1 — August 2022 102


Release Notes Skylight element: GT Version 7.9.4

ATRC-B19892 Alternate default configuration


The Alternate Default Configuration feature allows the Manufacture to identify the set of
default configuration settings on a unit.
• Manufacture config: 0000 refers to the Accedian common default configuration.
• Manufacture config: xxxx refers to an alternate default configuration such as
0001 whereas, by default, the Management Interface is tied to a physical Traffic
port instead of being present on the physical Management port.

ATRC-B20290 Outgoing Port to Policy lists display in WEB GUI


A new column has been added to the Policy lists display to show what Outgoing Port each
policy is mapped to.

ATRC-B20353 Increase default Y.1564 Service Acceptance Criteria Values


The default Service Acceptance Criteria Values have been increased to 5000 uS for Frame
Transfer Delay (from 100 uS ) and to 1000 uS for Frame Delay Variation (25 uS).

ATRC-E03675 Component ID
When creating a MA/MEG in SOAM, a new optional parameter has been added to specify
the desired component ID, instead of specifying the VCE name.
When creating a VCE, the user can optionally specify the desired component ID. If not
specified (0), the system will assign an ID.

ATRC-E03672 MIP/MEP Placement, creation and validation


Previous implementation could result in mapping multiples bridge ports together, causing
MIP/MEP creation and evaluation to fail based on system configuration.
The MIP creation algorithm has been fixed in this release, allowing the MIPs (based on
system configuration and placement of MEPs) to be configured at the correct level
independently per bridge port.

ATRC-B20194 VCA in VCA


As of Release 7.6, an implicit VCA will be created when the VCE type is set to Tunnel.
Only one implicit VCA (containing VCE of type tunnel) may be included in another VCA.
Therefore, the maximum amount of VCEs of type Tunnel that can be created is limited to
the maximum number of VCAs on this platform.
As of Release 7.6, a user can no longer assign a VCE of type Tunnel to a VCA. Instead, the
implicit VCA that contains a VCE of type Tunnel may be assigned to a VCA. All rules that
apply to a VCE of type Tunnel from Release 7.5 within a VCA, continue to apply to the
implicit VCA.

Revision 1 — August 2022 103


Release Notes Skylight element: GT Version 7.9.4

When upgrading from 7.5, the system will create implicit VCAs for all VCEs of type Tunnel.
As part of the upgrade process, any VCAs containing VCEs of type Tunnel will be
automatically replaced with their corresponding implicit VCAs.

Note: If the maximum implicit VCA count is reached or if the implicit VCA creation would
result in a name clash with an existing VCA, then the upgrade process will skip that VCE
of type Tunnel and a corresponding error will appear in the syslog.

14.2 Addressed Issues

ATRC-7211 IPv6 interface port change is not properly handled


Corrected a potential connectivity issue caused by changing the current port value to
another port in the system (a physical port or a LAG) when editing an existing IPv6
interface.

ATRC-D06620 Historical Data: The first period in certain categories may contain inconsistent
values
After enabling historical data collection, either through the History Buckets or Vision Collect
features, the data pertaining to the very first period can contain inconsistent values due to
the counters not being properly initialized. However, all subsequent periods will report
valid, consistent data. This applies only to the Policy, Regulator, Shaper and Port categories.
This issue has been fixed.

ATRC-D15068 Y.1564: Error displayed when running 1-Way configuration test for multiple
service
Corrected an issue where Initial 1-Way Y.1564 test for multiple services would complete
successfully but subsequent attempts would fail with the following error message:
“ERROR: Hardware resource not available for the moment”.

ATRC-D15502 LT-S/GT 7.4 SOAM PAA and SAT Y.1564 do not function correctly together
PAA reports lots of errors on a link between a GT and a LT-S when starting a Y.1564 test
on that same link. This issue has been fixed.

ATRC-D15556 CSF send but no port down alarm recorded


A fault propagation is sent to the far end, causing disruption of services. However, the logs
are not showing any events. This issue has been fixed.

Revision 1 — August 2022 104


Release Notes Skylight element: GT Version 7.9.4

ATRC-D16474 GT management not working with VLAN - CFI 1


When a management VLAN interface is created on the GT running release 7.5 either in-
band or out of band, and the management frames are coming with CFI 1, the GT is not
replying to the ICMP, and the device cannot be accessed. This issue has been fixed.

ATRC-D16550 GT Performance Element temperature sensor #1 shows 0 as current temperature


When invoking the “board show status” command on a GT Performance Element, the
temperature sensor #1 always shows 0 as the current temperature being monitored.
This issue has been fixed.

ATRC-D16577 Should not require passcode when importing CA Certificate


When importing a CA Certificate, it is required to enter a passcode but when special
characters (such as ‘ or |) are used, it will prompt error message.
This issue has been fixed. Passcode is still required but special characters can be used
without prompting an error message. This issue has been fixed.

ATRC-D16592 RFC2544 test suite giving wrong results (Generator working rate Layer-2)
If a test is configured at Layer-2 and the port where the test is going to be originated from
is at 100Mbps, the test suite starts and passes giving wrong values. This issue has been
fixed.

ATRC-D16679 Incorrect decoding of the Reply Ingress TLV in LTR packets prevents the LTM test
from working
The incorrect decoding and validation of the Reply Ingress TLV contained in the LTR
response frames leads to the incorrect operation of the LTM test. This occurs when the
entity replying to the LTM packets adds its Ingress Port Id attributes in the Reply Ingress
TLV.
This issue has been fixed.

ATRC-D16831 Creating a VCE external to external with a long name results in implicit VCA errors
The maximum VCE name size and the maximum VCA name size are 58 characters not
including NULL space. If a user creates a VCE between two external ports with a name size
between 56-58 characters, an error will occur. The system will try to create an implicit VCA
with name size VCA-VCE_name. This can lead to overwriting VCA data and multiple errors
in system. This issue has been fixed.

Revision 1 — August 2022 105


Release Notes Skylight element: GT Version 7.9.4

ATRC-D17232 Specify in the GUI that CBS and EBS values within Y.1564 tests are for future use
This issue has been fixed in Release 7.6. The CBS and EBS values used for Y.564 Service
Configuration testing are 8 KiB. The system will generate an error message when
attempting to configure a value other than 8.

ATRC-D17245 Getting “error invalid internal loopback timeout” when adding Alias to
management port via Web GUI
Users cannot add any information in the Alias column under Management Port
Configuration. When attempting to do so, users get the “error invalid internal loopback
timeout” error message. This issue has been fixed.

ATRC-D17290 Y1564: Missing State column on activation result (CLI only)


When a user tries to specify the physical ID, the request will be ignored as the port is
internal and is set to an internal value. No error message will indicate that behavior.

ATRC-E03619 Certificate Management and Import


Release 7.6 addresses several issues and limitations concerning the importing, handling and
error reporting of SSL certificates.

ATRC-D16548 NTP status always shows “synchronized” when enabling the NTP server
Addressed a case where enabling/disabling the NTP server could erroneously display a sync
status of “Synchronized”.

ATRC-D16138 False Fan Slow Alarm


A false “Fan Slow” alarm/warning can be triggered on GT performance elements. This issue
has been addressed in order to reduce the possibility of triggering a false alarm.

Revision 1 — August 2022 106


Release Notes Skylight element: GT Version 7.9.4

15. Firmware Version 7.5_13705 (2017-08-24)

15.1 New Features and Enhancements

ATRC-E03274 VCE/VCA
A Virtual Circuit Access (VCA) describes a customer’s traffic flow access to the service
provider’s network through the edge performance element. VCAs specify the inward path
(TP A towards TP Z) actions performed at different edge (boundary) points in the network
(the outward path TP Z towards TP A actions are inferred).
A VCA element is formed by an ordered list of one or more individual Virtual Circuit
Endpoints (VCE) elements in order to form an external port-to-external port definition for
the Virtual Connection Access.
The Virtual Connection defines the traffic path to be used by UP MEP and MIP.

ATRC-E03504 UpMEP/MIP
Added support to configure a Down Mep, Up MEP or MIP, on a VLAN component created
via the VCA (Virtual Circuit Access).

ATRC-E03627 Increase Max length RADIUS Secret Key to 48 Characters


With release 7.5 the RADIUS secret password length has been extended to 48 characters.

ATRC-B19822 Client Port Cut-Off


The following feature allows the client to configure a network performance threshold
below which the client port is automatically disabled in order to advertise the link failure to
a peer network.
A user-configurable timer is available to define the time to wait before restoring the link
after the network performance has returned to normal. Default value is 120. Range is 0 to
300 seconds in increments of 1 second.
A user-configurable timer is available to define the time to wait before disabling the client
port after the network performance has fallen below the configured threshold. Default
value is 0. Range is 0 to 120 seconds in increments of 1 second.

ATRC-E03576 Supporting CCM Config Commands for Integration with Provisioning Tool
An enhancement to provide a more user-friendly feature allows CMM Config Commands to
be referenced not just by number but also by name. This enables more flexibility is searching
for the command.

Revision 1 — August 2022 107


Release Notes Skylight element: GT Version 7.9.4

15.2 Addressed Issues

ATRC-7211 IPv6 interface port change is not properly handled


Changing the current port value to another port in the system (a physical port or a LAG)
when editing an existing IPv6 interface can cause connectivity issues, since the current
interface in the kernel is duplicated instead of deleted.

ATRC-D07190 Y.1564: Loss of sync causes one-way tests to fail even when Sync is disabled
When a one-way Y.1564 test is executed without enabling the Mandatory Time Sync
option, a large time synchronization adjustment (NTP or PTP) can sometimes affect the
FDV measurements, causing the test to fail.
Normally, when the Mandatory Time Sync option is not enabled, the test ignores any time
adjustments. Although this issue is rare, it is more likely to occur in a long-duration test
(e.g., 24 hours).

ATRC-D14244 Deleting a filter customer is getting “ERROR: Unknown instance.”


If a user replaces a filter by a VID set in a policy and deletes that filter, he will get an error
message when trying to create a new filter.
That issue has been fixed in 7.5.

ATRC-D15450 UDP range values


UDP range issue in 7.4 has been fixed in 7.5.
The range values are now displayed properly in both GUI and CLI.

Revision 1 — August 2022 108


Release Notes Skylight element: GT Version 7.9.4

16. Firmware Version 7.4_11358 (2017-03-16)

16.1 New Features and Enhancements

ATRC-D02465 Internal Loopback Timeout Feature


A programmable timeout with a default value of 5 minutes allows safe recovery of the link
usage in case of misuse. A timeout allows for recovering the port usage after the timeout.

ATRC-B04979 In Service Throughput Testing


A customer desire to use the Accedian In Service Throughput Testing on all platforms
motivated this development. The improvements pertain to the GUI/VisionEMS to support
easier setup and result gathering. It is now available on the following platforms:
• LT/LT-S
• GT
• GX

ATRC-B08128 Manual SFP Rate Override


A new mode, “manual override,” is added to the SFP rate options. The option “auto-detect”
already exists.

ATRC-B17560 Align TWAMP Generated Measurement Periods to time of day fixed boundaries
A Network Operator would like the option to have the generated reports of TWAMP Gen
with the PAA aligned to the global time boundary. PAA sessions do align to preset time
boundaries.
Example of alignment (hh:mm) of measurements vs reference period for a session:
• 1 minute reference period → measurement timestamps should align with
hh:00, hh:01, hh:02, hh:03.
• 15 minute reference period → measurement timestamps should align with
hh:00, hh:15, hh:30, hh+1:00.

ATRC-B17743 Increases the number of indexes in the ACL


There is a need for more than 20 unique IP addresses in the ACL of the 1G10G product line.
We have increased the number of available IP addresses to 40.

Revision 1 — August 2022 109


Release Notes Skylight element: GT Version 7.9.4

ATRC-B18376 Disabling Client Port on Network Performance Degradation


A network operator can specify a network performance threshold below which the client
port is automatically disabled in order to force traffic over a secondary link. This is supported
on GT only.

ATRC-B18377 Added Debug Capabilities


Customers wish to collect more system level information when a product misbehaves in
order to accelerate the troubleshooting effort.

16.2 Addressed Issues

ATRC-D14228 LTS Reboots when Setting a VID-Set


When there are too many VLANS the system rebooted upon setting a VID-Set.
This issue has been resolved.

ATRC-D14040 Service Availability Metric Is Incorrectly Functioning


The threshold value was incorrectly applied potentially resulting in false triggers.
This issue pertains to D13981 as well as 06360.
This issue has been resolved.

ATRC-D14040 SA Metric Is Incorrectly Functioning with CFM Packet Loss


The problem was that the threshold value in the SA Metric occasionally did not accept value
input first time. This issue has been resolved.

ATRC-D13887 Y.1564 Error


When starting the Y.1564 Performance test with CIR=0, we get an unclear message.
This issue has been resolved.

ATRC-D13758 Y.1564 Transfer Delay Type Selected Option Changes on Reboot


Once the options for the y1564 Frame Transfer Delay Type and the Frame Delay Variation
Type to AVG and the system is rebooted, the option reverts to MAX, which is the default
value.
This issue has been resolved.

Revision 1 — August 2022 110


Release Notes Skylight element: GT Version 7.9.4

ATRC-D13257 Devices in the Ring Restart at the same time


Devices in the ring suddenly restarted (with reason: panic) when handling an unexpected
frame. Handling of unexpected frames has been corrected.
This issue has been resolved.

ATRC-D13353 Fault Propagation with Auto-Nego Disabled


When doing fault propagation to a port (fiber) with auto-nego disabled, the port TX signal
goes down and the peer port goes down. However, since the peer TX signal is active, the
port status is displayed as UP.
This issue has been resolved.

ATRC-D13330 Unable to enable ports that were disabled at initialization


When a unit booted with one or many ports disabled, the action of enabling the port would
switch the port state to UP, but the port would not process any traffic.
Workaround: Complete one of the following actions to cause the port to begin processing
traffic:
• Disable, then re-enable the port
• Reseat the SFP in its cage
• Reboot the unit after the port has been enabled
This issue has been resolved.

ATRC-D12753 LBM/LTM Not Refreshing


When using LBM or LTM, the display does not auto refresh properly on the GT and LTS. It
happens with IE and Chrome and clearing the browser cache does not change the
outcomes.
This issue has been resolved.

ATRC-D12644 Certain copper SFPs not reporting full capabilities at boot-up


Certain copper SFPs would not report their full range of speed capabilities at boot-up, which
prevented them from connecting at certain supported speeds such as 10 Mbps or 100 Mbps.
These copper SFPs are no longer restricted to the advertised speed and will work at other
rates if supported.
This issue has been resolved.

Revision 1 — August 2022 111


Release Notes Skylight element: GT Version 7.9.4

ATRC-D12559 Variations in signal frequency corrupt jumbo frames


Variations in the signal frequency occasionally impacted the structure and content of jumbo
frames, even when the level of variation was below the tolerated limit. This issue affected
copper ports only.
This issue has been resolved.

ATRC-D06787 Incorrect units used for CBS/EBS and queue sizes


User Interface (GUI and CLI) FOR burst sizes (CBS, EBS) and queue sizes were previously
expressed in kB (kilobyte) or MB (megabyte). According to the IEC 60027-2 A.2 and ISO/IEC
80000 standards, the units KiB (kibibyte) and MiB (mebibyte) should be used for these
parameters.

ATRC-D04164 LAG: The Working Connector Command has a Delayed Response


About once in every ten actions, there is a delayed response in the LAG on the Working
Connector command. The normal function has you enter the command and the system
determines which connector be linked up—most often selecting the first port (RJ45-3) and
does so at normal speed.
But on the 1 in 10-situation, it will take about 60 seconds before the link-up switches to
RJ45-3 as requested.
This could be improved. There should be a protection in case the last command was entered
too early.

Revision 1 — August 2022 112


Release Notes Skylight element: GT Version 7.9.4

17. Firmware Version 7.3.0.3_10522 (2016-12-12)

17.1 New Features and Enhancements

ATRC-B18168 Support for Transport Layer Security (TLS) library version 1.2
The TLS encryption protocol library has been upgraded to version 1.2 across all platforms in
order to protect Accedian products from Denial of Service (DoS) attacks.

17.2 Addressed Issues

ATRC-D13622 Certain copper SFPs not reporting full capabilities at boot-up


Certain copper SFPs would not report their full range of speed capabilities at boot-up, which
prevented them from connecting at certain supported speeds such as 10 Mbps or 100 Mbps.
These copper SFPs are no longer restricted to the advertised speed and will work at other
rates if supported.

ATRC-D13282 Copper port speed set to 100 was not persistent


When a copper port was configured for 100M without auto-negotiation, it would revert to
1G after the unit rebooted.

ATRC-D09550 Reliably retrieving SNMP MIBs via the snmptable utility


SNMP MIBs can be retrieved using a command line utility called snmptable. Data retrieval
errors may occur when the utility is used to retrieve the same element repeatedly, however.
Workaround: Use the utility’s -CB option to avoid these errors when retrieving SNMP
MIBs.

Revision 1 — August 2022 113


Release Notes Skylight element: GT Version 7.9.4

18. Firmware Version 7.3.0.2_9184 (2016-09-09)

18.1 New Features and Enhancements


None.

18.2 Addressed Issues

ATRC-D10696 Connectivity Fault Management (CFM) alarm status does not update
Under specific race conditions in the CFM fault-handling mechanism, certain alarms could
have remained in the present state, even after the initial condition for raising the alarm has
been successfully cleared.

ATRC-D12559 Variations in signal frequency corrupt jumbo frames


Variations in the signal frequency occasionally impacted the structure and content of jumbo
frames, even when the level of variation was below the tolerated limit. This issue affected
copper ports only.

Revision 1 — August 2022 114


Release Notes Skylight element: GT Version 7.9.4

19. Firmware Version 7.3.0.1_8962 (2016-08-12)

19.1 New Features and Enhancements

ATRC-D01673 Support for an additional RADIUS server


The 1G/10G Performance Elements now support the selection of up to three RADIUS servers
for authentication.

ATRC-E03023 Support for Legacy S-VLAN (TPID=0x9100)


Recently introduced is the ability to dynamically choose which TPID value to associate
system-wide with the S-VLAN Ethertype. Supported values are 0x88a8 (default) and
0x9100. All system elements that make use of the S-VLAN and T-VLAN Ethertypes are
affected, including interfaces, filters and RFC-2544.
If the S-VLAN TPID value is changed to 0x9100, the T-VLAN TPID value is automatically
updated to 0x88a8 to effectively prevent any conflicting configurations or ambiguous
behavior.

ATRC-E03101 Add UDP port 862 for TWAMP generation and reflection
The TWAMP feature has been expanded to include UDP port 862 for generation and
reflection. The accepted range of UDP ports now includes 862, as well as any value within
the range of 1025 to 65535.

ATRC-E03088 SyncE support on the GT Performance Element


The GT Performance Element now supports clock recovery (frequency) from primary and
secondary synchronization source ports, in accordance with ITU-T Rec. G.8262.
Additionally, source quality detection is supported through the implementation of the ITU-
T Rec. G.8264 specification (ESMC protocol).

ATRC-E03072 Hierarchical Bandwidth Policing for the GT Performance Element


Hierarchical Bandwidth Policing, as specified in the MEF 10.3 standard, is a traffic
conditioning method which respects a prioritized flow’s right of way, while allowing lower-
priority flows to effectively use leftover bandwidth from higher-priority flows to increase
overall multi-service performance. Hierarchical Bandwidth Policing (H-BWP) is the
evolution of crushing the edge; ensuring highest priority packets’ transmission is assured
by tiered scheduling. As a policing mechanism, this process is conducted at wire-speed
without store-and-forward queuing delays.

Revision 1 — August 2022 115


Release Notes Skylight element: GT Version 7.9.4

ATRC-E03065 Support for up to 255 MEPs per MA/MEG


The CFM feature now supports up to 254 remote Maintenance End Points (in addition to
the local end point) per Maintenance Association representing an E-LAN or E-TREE type
EVC.

ATRC-E03039 Remote MEP auto-discovery


The CFM feature has been extended to support the dynamic detection of remote
Maintenance End Points. This is useful when dealing with a large number of remote MEPs,
especially in an E-LAN deployment or when provisioning the root node of an E-TREE
deployment.

ATRC-E03254 Increased TACACS+ user password length


The maximum permitted password length for TACACS+ authentication is now 64
characters (previously 31 characters). This will allow network operators to use stronger
credentials for better security. Note that for Local and Radius user authentication, the
supported password length remains 31 characters.

ATRC-E03087 Increased width of TACACS+ secret to 64 characters


TACACS+ authentication has been made more robust with support for up to 64 characters.

ATRC-E02970 Loop detection auto-squelch


Accedian has enhanced its Loop Detection feature to include the provisioning of dynamic
traffic blocking (i.e. squelching without operator intervention) when an ongoing loop is
detected.
The automated squelch supports the following two modes:
• auto/revertive (default): Traffic is blocked and unblocked automatically
• auto/non-revertive: Traffic is blocked automatically, but unblocked manually

19.2 Addressed Issues

ATRC-D11676 L2PT tunnel not working when 3 VLANs are involved


Due to a system limitation, triple-tagged layer2 protocol frames were bypassing the de-
tunneling path.

ATRC-D11181 ERP port can switch to an erroneous state


When a Signal Fail occurs on a ring port of a unit that is part of a ring, and a Forced Switch
followed by a Clear on a different unit in the ring is subsequently applied, the ring
management state machine (ERP G.8032) of the unit where the Signal Fail occurred will

Revision 1 — August 2022 116


Release Notes Skylight element: GT Version 7.9.4

occasionally become stuck in the idle state and will not send the Signal Fail following the
Clear operation on the ring.

ATRC-D10880 Truncation of the 24-hour Y.1564 test with EMIX frames


When a Y.1564 test is configured to run for 24 hours (1440 minutes) using EMIX frames,
the test’s actual duration could be significantly less than the expected 24 hours.

ATRC-D10543 Limitation in performing service activation testing using Layer-3 traffic


Service activation testing using Layer-3 traffic generation on a port that is part of a bridge
interface was not working.

ATRC-D10386 Adding SA metric source names that start with a zero no longer results in error
Adding SA metric source names that began with a zero would result in the following error:
“invalid metric source”.

ATRC-D09656 Legacy copper SFPs supported on the GT Performance Element


Auto-detection of the copper SFP PHY address has been implemented to ensure that
copper SFPs with a PHY address of 0xA6 will be correctly detected.

ATRC-D09646 ACL with IP address entered as 0.0.0.0 not accepted


New business rules now effectively prevent entering 0.0.0.0 as an IP address as this value
is an unsupported configuration.

ATRC-D09461 SFP read errors caused by inconsistencies in I2C protocol interface


The handling of SFPs has been improved to address certain inconsistencies in the I2C
protocol interface. It had been reported that some SFPs returned incorrect data when
presented with multiple I2C STOP commands on their I2C interfaces.
This issue has been resolved in this firmware release, however, due to these interface
inconsistencies, affected SFPs never reported digital diagnostics, even if they supported
such functionality. These SFPs will now begin reporting digital diagnostics, which could
result in the SFP raising alarms that had not previously been seen.

ATRC-D08684 Upgrading the firmware through the Web interface would fail
When using the Web interface to upgrade the firmware, the upgrade process would
terminate unexpectedly and fail to upgrade the firmware.

Revision 1 — August 2022 117


Release Notes Skylight element: GT Version 7.9.4

ATRC-D08515 Filter VLAN stack size attribute was ignored if either vlan1-ethertype or vlan2-
ethertype attributes were set
When defining a filter, if a value was specified for the vlan1-ethertype or vlan2-ethertype
attributes, the value of the VLAN stack size attribute would be ignored.

ATRC-D06908 LACP would not recover from rapid switching back and forth
The LACP state machine has been adjusted to be more responsive to link up events.

ATRC-D06132 OAM custom loopback behavior when no filter was specified


When an OAM Custom Loopback was enabled without being assigned a specific filter (i.e.,
the Filter Name was left blank), the loopback behaved as if a Catch-All filter were selected.
The associated port would consequently loop back all the service frames it received.

ATRC-D05526 LAG revertive feature and WTR logic would cause traffic loss when failed over in
specific scenario
LAG protection was waiting for full Wait to Restore period to switch over to primary link,
even though secondary link falls into fault state: now the Wait to Restore time is bypassed
when a fault is detected on the secondary active link.

ATRC-D03774 LACP: Forwarding to Ring LAG was permitted while in Defaulted state
The IEEE802.1AX standard specifies that no Tx/Rx traffic should be allowed in an
LACP-based link if it is not in the Collecting/Distributing state. The implementation
previously allowed forwarding frames that were in the Defaulted state from an
LACP-based LAG to an ERP-based LAG.

ATRC-D03378 Creating a second ring on a pass-through NID is causing traffic disruption on the
first ring
Previously, updating the classification engine required a temporary disable of the rules logic.
This has now been changed to support no hit updates.

Revision 1 — August 2022 118