Selection Guide
Part Input Output Output Efficiency (1) max. Capacitive
Number Voltage Range Voltage Current @ min. Vin @ max. Vin Load (2)
[VDC] [VDC] [A] [%] [%] [µF]
R-78E3.3-1.0 7-28 3.3 1.0 91 84 220
R-78E5.0-1.0 8-28 5.0 1.0 93 85 220
R-78E12-1.0/X9 15-27 12 1.0 97 93 100
Notes:
Note1: Efficiency is tested at full load at +25°C ambient
Note2: Max. Cap Load is tested by nominal input and full resistive load
C O N V ER CO NVE R
M T M T
O O
C C
E
E
RE
RE
R
R
S
S
RoHS 2 + REACH
compliant compliant
10 from 10
CO
CO
TS
TS
Model Numbering
M M
C
C
PL U P U
IA N D LIA D
T PRO N T PRO
Specifications (measured at Ta= 25°C, full load, Vin= 24VDC and after warm-up)
BASIC CHARACTERISTICS
Parameter Condition Min. Typ. Max.
Input Current min. Vin 1000mA
Quiescent Current 1.5mA
3.3 & 5Vout 330kHz
Internal Operating Frequency
12Vout 570kHz
Minimum Load only R-78E12-1.0/X9 2%
Output Ripple and Noise (4) 20MHz BW 120mVp-p
Notes:
Note4: Measurements are made with a 100nF MLCC across output (low ESR)
R-78E3.3-1.0 R-78E5.0-1.0
100 100
90 90
80 80
70 70
Efficiency [%]
Efficiency [%]
60 60
50 50
40 40
30 7Vin 30 8Vin
12Vin 12Vin
20 20
24Vin 24Vin
10 28Vin 10 28Vin
0 0
0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100
Output Load [%] Output Load [%]
R-78E12-1.0/X9
100
90
80
70
Efficiency [%]
60
50
40
30
15Vin
20 18Vin
24Vin
10
27Vin
0
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
REGULATIONS
Parameter Condition Value
Output Accuracy ±3.0% typ. / ±5.0% max.
Line Regulation low line to high line, full load ±1.0% max.
Load Regulation typ Vin. and 10% to 100% load ±1.5% max.
PROTECTIONS
Parameter Condition Value
Short Circuit Protection (SCP) Continuous, automatic recovery
Derating Graph
100
90
80
70
Output Load [%]
60
50
40
30
20
10
0
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100
85
Ambient Temperature [°C]
GND GND
embossed logo
11.6 8.5
Pin Connections
10.4
Marking
Pin # Function
0.51
1 +Vin
2 GND
3 +Vout
4.10
0.70+0.10/-0.05 0.25±0.05
Tolerance: xx.x= ±0.50mm
xx.xx= ±0.25mm
5.08 3.21 Recommended Footprint Details
2.54
1 2 3 Top View
2.00
1 2 3
Bottom View
2.54
C1 C2 Notes:
10µF MLCC 10µF MLCC
(optional) (optional) Note6: The R-78Exx-1.0 can not be used as positive to negative converter
GND GND
To protect the converter during power-up, use soft start power supply.
PACKAGING INFORMATION
Parameter Type Value
Packaging Dimension (LxWxH) tube 520.0 x 11.2 x 18.2mm
Packaging Quantity 42pcs
Storage Temperature Range -55°C to +125°C