You are on page 1of 3

MPS P1375 / MPS P1375S

50 Hz

Features Photos are for reference only

• Compact Structure & High-strength Chassis


• Easy for Operation and Maintenance
• Good Performance Anti-vibration System
• Compliance with International Electrical Safety Standards
• 9/7 Hours Base Tank
• High-performance Free-maintenance Batteries
with Isolation Switch
• 50ºC Radiator
• Top Lifting Point, Fork Lift Holes, Easy for Transportation
• Industrial Type Muffler
• Noise Reduction Structure, Low Overall Noise
• Convenient Power Output Interface and ATS Interface
• IP56 (Control System)
• The Customized Design

Genset Technical Data


Output Frequency 50 Hz
Rated Speed 1500 rpm
Prime Power 1250 kVA
Standby Power 1375 kVA
Rated Voltage 400 v
Phase 3
Dimension and Weight Engine Model 4012-46TWG2A

MPS P1375S Alternator Stamford


Generating Set Model 20 ft Container MPS P1375
Fuel Consumption of 100% load 261.6 L/h
Length (L) mm 6058 4700 Exhaust Gas Flow (after turbo) 180 m³/min.
Width (W) mm 2438 1780 Exhaust Temperature 422ºC
Height (H) mm 2591 2480 Max Back Pressure 5 kPa
Dry Weight kg 14500 9500 Max Intake Restriction 4 kPa
Tank Capacity L 700 – Combustion Air 109 m³/min.
Noise Level @1m Full load 90dB – Radiator Air Flow 1320 m³/min.
MPS P1375 / MPS P1375S

Engine Specifications
Engine Model 4012-46TWG2A
Engine Manufacturer PERKINS
Number of Cylinders 12
Cylinder Arrangement 12 in “V”
Cycle 4 Cycle
Aspiration Turbocharged, water-air charge cooled
Bore x Stroke 160 x 190 mm
Displacement 45.842 Liter
Compression Ratio 13.6
Standby Power/Speed 1217 KW / 1500 rpm
Speed Governor Electronic
Cooling System Forced Water Cooling Cycle
Total Lubrication System Capacity 159 Liter
Coolant Capacity (with radiator) 225 Liter
Fuel Consumption at 100% load 261.6 L/h (at 1500 rpm)
Starter Motor DC 24 V
Alternator DC 24 V
Alternator Specifications
Alternator Stamford
Rated Output Prime Power 1250 kVA
Efficiency 94.9%
Rated Speed 1500 rpm
Rated Frequency 50 Hz
Phase 3
Rated Voltage 400 V
Exciter Type Self excitation, Brushless
Power Factor 0.8
Voltage Adjust Range ≥5%
Voltage Regulation NL-FL ≤±1%
Insulation Grade H
Protection Grade IP23
Standby Prime
Voltage Hz Phase P.F Standby Ratings Ratings
/

(COS C) Amps (KW/kVA) (KW/kVA)


440/254 50 3 0.8 1804 1100/1375 1000/1250
415/240 50 3 0.8 1913 1100/1375 1000/1250
400/230 50 3 0.8 1985 1100/1375 1000/1250
380/220 50 3 0.8 2089 1100/1375 1000/1250

Prime Power (PRP): Prime power is available for an unlimited number of annual hours in variable load application, in accordance with
GB/T2820-97 (eqvISO8528); A 10% overload capability is available for a period of 1 hour within a 12-hour period of operation.
Standby Power Rating (ESP): The standby power rating is applicable for supplying emergency power for the duration of
a utility power interruption. No overload, utility parallel or negotiated outage operation capability is available at this rating.
MPS P1375 / MPS P1375S

Control System
DSE-7320 (Standard)
All MPS Power Gensets have a control cabinet (the Deepsea control module DSE-7320 as standard)
mounted on gensets.

Optional
Main Features
• Manual and Automatic Mode
• Parameter Configuration via RS-232
serial communication
• Remote Control Automatic Start/Shutdown
• Optional ECU Control
• Optional CAN Engines
• Optional Speed Sensor Access DSE 8610
• PLC Programming
• Operating Temperature: -20ºC to 70ºC
• IP56 Rating
• Back-Lit icon LCD display
• Power Save Mode
• CAN and Magnetic Pick-up/Alt. versions available
(specify on ordering)
• PC Configurable
• 6 Digital inputs WOODWARD easYgen-3400XT/3500XT
• 4 Outputs (2 configurable on Magnetic Pick
up/Alt., 4 configurable)
Protecting Functions

The Control Module Display • Over Frequency / Under Frequency


• Over Voltage / Under Voltage
• Generator Voltage • Over Current
• Generator Frequency • Over Speed / Under Speed
• Battery Voltage • Emergency Stop
• Engine Speed • Low Oil Pressure
• Load Current • High Water Temperature
• Engine Run-time Hours • Failure to start / Failure to stop
• Engine Oil Pressure (Panel Meter) • Battery Charger Failure
• Engine Coolant Temperature (Panel Meter) • Comprehensive shutdown or warning on fault condition

Jl. Bendungan Hilir Raya No. 132 Bendungan Hilir, Tanah Abang - Jakarta Pusat 10210
+6221 2988 0666 (Hunting) +6221 573 7469 marketing@powerindo.com www.powerindo.com