ACE 01 ENGINEERING
UTILITIES 1
Submitted to:
ENGR. LLOYD MITCHELL MACADANGDANG
Instructor
1ST Semester
S.Y. 2022 – 2023
32.081 32.081 32.081
12.144
12.144
12.144
12.144
12.144
ROOM 302 ROOM 301 ROOM 202 ROOM 201 ROOM 102 ROOM 101
10.689
13.05
39.875
39.875
ROOM 203
39.875
ROOM 103
16.313
16.313
ROOM 303
FIRE EXIT
FIRE EXIT
lounge area lounge area lounge area
CONTROL
ROOM
entrance
27.731
27.731
27.731
27.731
27.731
6.048
14.681
ROOM 304 ROOM 204
11.419
ROOM 104
11.419
10.9
ELEVATOR ELEVATOR
T&B T&B T&B T&B T&B T&B ELEVATOR
17.038 15.044
T&B T&B
12.144
12.144
ROOM 102 ROOM 101
14.319
T&B
10.689
13.05
39.875
ROOM 103
lounge area
CONTROL
ROOM
entrance
27.731
6.048
14.681
10.9
ELEVATOR
T&B T&B
46.4
17.038 15.044
T&B T&B
12.144
12.144
ROOM 202 ROOM 201
14.319
T&B
39.875
ROOM 203
16.313
FIRE EXIT
lounge area
27.731
27.731
ROOM 204
11.419
ROOM 205
ELEVATOR
T&B T&B
46.4
T&B T&B
12.144
12.144
ROOM 302 ROOM 301
14.319
T&B
39.875
16.313
ROOM 303
FIRE EXIT
lounge area
27.731
27.731
ROOM 304
11.419
ROOM 305
ELEVATOR
T&B T&B
46.4
SYMBOL DESCRIPTION
PB PULL BOX
FIRE SPRINKLER
SMOKE DETECTOR
FIRE EXTINGUISHER
CA
T&B T&B
CA
M
T&B T&B
T&B T&B
ROOM 302 ROOM 202 ROOM 201
ROOM 301
T&B
T&B
T&B
FIRE EXIT
open area
FIRE EXIT
open area
PB
CAM ROOM 103
CAM
lounge area
CONTROL
ROOM
entrance
DVR
CAM
ELEVATOR
T&B T&B
M
M
CA
CA
THIRD FLOOR CCTV LAYOUT
scale nts
SECOND FLOOR CCTV LAYOUT GROUND FLOOR CCTV LAYOUT
scale nts scale nts
T&B T&B
T&B
PB
ROOM 103
lounge area
CONTROL
ROOM
entrance
DVR
CAM
ELEVATOR
T&B T&B
M
CA
GROUND FLOOR CCTV LAYOUT
scale nts
T&B T&B
T&B
ROOM 203
FIRE EXIT
open area
CAM
ELEVATOR
T&B T&B
CA
CA
M
T&B T&B
T&B
ROOM 303
FIRE EXIT
open area
CAM
ELEVATOR
T&B T&B
M
CA
M
CA
PB
PB
CAM
CAM
CAM
PB
PB
CONVENTIONAL SYSTEM
+
+
CCTV GENERAL NOTES
1. ALL ELECTRONICS WORKS HEREIN SHALL BE DONE IN ACCORDANCE WITH THIS PLAN AND SPECIFICATIONS, THE
APPLICABLE PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE ELECTRONICS CODE AND WITH THE
REQUIREMENTS AND RECOMMENDATIONS OF THE CURRENT EDITION OF THE NATIONAL FIRE PROTECTION
ASSOCIATION STANDARD (NFPA) 72 & FIRE CODE OF THE PHILIPPINES.
2. ALL EXPOSED CONDUITS, IF ANY, SHALL BE INSTALLED PARALLEL TO OR PERPENDICULAR TO THE BUILDING LINE AND
SUPPORTED WITH CONDUIT CLAMPS OR LOOP HANGER WITH ROD FOR EVERY 15 METER DIAGONAL CONDUIT RUN
SHALL NOT BE ACCEPTED.
3. NETWORK CABLES CONDUIT SHALL HAVE A MINIMUM DISTANCE OF 0.3 M FROM POWER CONDUIT WHEN LAID
PARALLEL & MUST RUN PERPENDICULAR TO THE STEEL CONDUIT WHEN CUTTING ACROSS A POWER LINE.
4. TERMINAL CABINETS/DISTRIBUTION FRAME SHALL BE PROPERLY LABELED FOR PROPER IDENTIFICATION OF CABLE
TERMINATION LOCATION.
5. ALL PULL BOXES SHALL BE USED WHEN APPLICABLE FOR EASY PULLING OF WIRES AND SHALL BE IN ACCORDANCE
WITH THE PHILIPPINES ELECTRONICS CODE MINIMUM REQUIREMENT.
6. SIZE OF THE UPS SHALL BE BASED ON THE ACTUAL REQUIREMENTS OF THE COMPLETE CCTV SYSTEM. DO NOT
COMBINE ELECTRONICS OUTLET WITH ELECTRICAL OUTLET.
7. ALL ELECTRONICS WORKS SHALL BE NEATLY PLACED, SECURELY FASTENED AND PROPERLY FINISHED.
8. ALL MATERIALS TO BE USED SHALL BE BARND NEW AND OF APPROVED TYPE FOR THE LOCATION AND PURPOSE.
9. THIS DRAWING IS SCHEMATIC REPRESENTATION OF SYSTEM ONLY. TENDERS TO DETAIL COMPLIANT OFFER BASED ON
MANUFACTURER'S SYSTEM & WIRING METHODS RECOMMENDATION.
10. THE PLANS AS DRAWN ARE BASED UPON THE ARCHITECTURAL PLANS AND DOES NOT NECESSARILY SHOW ALL
FITTINGS NECESSARY TO FIT TO THE BUILDING CONDITIONS. THE LOCATIONS OF OUTLETS, APPARATUS AND
APPLIANCES SHOWN ON THE PLANS ARE APPROXIMATE. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THEIR
PROPER LOCATIONS IN ORDER TO MAKE THEM FIT WITH THE ARCHITECTURAL DETAILS AND INSTRUCTIONS FROM THE
ENGINEER'S REPRESENTATIVE AT THE SITE.
11. ALL ELECTRONICS WORKS & AUXILIARY INSTALLATIONS SHALL BE DONE UNDER THE DIRECT AND IMMEDIATE
SUPERVISION OF A DULY QUALIFIED REGISTERED PROFESSIONAL ELECTRONICS ENGINEER (PECE), ELECTRONICS
ENGINEER (ECE), ELECTRONICS TECHNICIAN (ECT), OR TRAINED SYSTEMS INSTALLER.
12. ALL ELECTRONICS PLANS SHALL BE SIGNED AND SEALED ONLY BY A REGISTERED AND LICENSED PROFESSIONAL
ELECTRONICS ENGINEER (PECE) PURSUANT TO R.A. 9292
FIRE EXIT
FIRE EXIT
lounge area
lounge area
lounge area
ELEVATOR
lounge area
FIRE EXIT
lounge area
FIRE EXIT
lounge area
ELEVATOR
SECOND FLOOR
EOL