You are on page 1of 7
D. TECHNICAL SPECIFICATIONS Reverse Osmosis Plant Since the Plants will be designed oa the basis of Area Specific and Pzob! Reverse Osmosis Plant can be used for purification of water that contains contamination like Fluoride, Brackish, Salinity, Arsenic, Nitrates, TDS, etc., The Plant comprises of the following suggestive components. However the emphasis should be suggested as per Indian Standards Norms/Specifications for the purified drinking water. There should be no compromise on the quality of water and the IS:10500-2012 desirable limits should be strictly achieved. Si. ‘Components Purpose No. 1 | Raw water storage tank | Raw water is fed into their tank to suit the Plant Capacity. 2) Raw water pump To pump raw water into the inlet of multi grade / dual media/sand filter. 3 | Multi grade / Dual This filter is used to remove the physical impurities like media / Sand filter turbidity, suspended solids including coarse particles, mud, sediment and sand etc., to suit the raw water quality. This filter reduces turbidity to the prescribed units to feed the | R.O Plant, | | 4 | Activated Carbon filter | This filter contains activated carbon, which removes colour, smell, odour, etc., of the water. It will also remove free chlorine in feed water as it causes 1 serious damage to the R.O membranes. 5 | Anti-scaling Dosing © Scaling accumulation (like Ca & Mg scales) on the System membrane will reduce its life and production. « Anti-scaling chemical is dosed to the membrane through feed water to prevent scaling tendency on the membrane. . © Volume of chemical added in the feed water varies on the water quality. 6 | Polymer dosing system | To maintain the P" value between the range of 6.5-8.5. 7 | Micron Cartridge filter | These filters are used to remove the left over particles passed through the Sand and Carbon filters. It can be filtered up to 5 or 10 micron particle size. 8 | High pressure pump to * For effective filtrition of water in the RO membrane a suit the plant capacity certain level of pressure is essential. This pump builds up high-pressures (0-16Kg/Cm2) and dissolved solids, bacteria etc. pumps the feed water to RO membrane for filtering the 9 |RO Block having quality stream and almost pure water comes out as The major quantity of dissolved salts is rejected with rejected separate stream. 10 | Product water storage | Collects the treated water. tank to suit the plant capacity _ TT [U.V. System unit contains one o: dal ultr lamp produces. ultravi spores. Therefore, the water or air that This U.V system is installed to Kill the bacteria that are developed in the storage tank (if any). An ultra~ microorganisms. Approximately 95% of the ultraviolet energy emitted is at the mercury resonance line of 254 nanometers, their wavelength is highly lethal to virus, bacteria and mold passes through the chamber is exposed to the germicidal U.V light and the genetic material of the microorganism is deactivated, which prevents them from reproducing and renders them harmless. 12 | Pure Water Outlet with To collect the pure water through the taps at the plant. tap points 13. | Shelter For different capacities of R.O Plants; a shelter of a suitable size shall be provided by the School / Institution / Gram Panchayat concerned and R.O Plant will be installed in such shelter. The cost of shelter should be borne by the School / Institution / Gram Panchayat concemed 2. Desirable Limits of Pure Water as per IS:10500-2012 SINo.] Contamination Raw | Treated | Permissible | Signature of the Water | Water | limits as per | Concessionaire z Level_| Level_| BIS:10500-2012 | _/ Operator ama Ee 6.5-8.5 2 | Colour Co-Pt 3 3_| Flouride mg/l 1 4 | Salinity (Chlorides) 250 5_| E.Coil no/100 MI Nil 6 | TDS mg 500 7 [Nitrate mg 45 8 | Iron (Fe) 0.30 ‘9 | Calcium (ca") 75 10 | Sulphate mg/l 200 11 _| Alkalinity mg/l 200 12_| Turbidity NTU 1 13 _| Manganese (mg/l) 0:30 Components of different capacities of R.O Plants and Standards No SCOPE OF SUPPLY ‘Sk Item (250 LPH) jon-1_ | Option-2 (500 LPH) Option-3_ | Option-4 4000 LPH) | (2000 LPH) Raw Water Storage Tank 1 2 | Multi Grade / Dual Media / 1 Sand Filter 1 Activated Carbon Filter 1 7 1 “Ante Scalent Dosing System T Polymer Dosing System . 1 High Pressure Pump R.O Block 3 4 5 6 | Micron Cartridge Filter 7 8 9 4” 4040 Membranes 10 | 4” Pressure Tubes (300 psi) 4040 11 | 8” 8040 Membranes 12 | 8 Pressure Tubes (300 psi) = 8040 13 | 8” Pressure Tubes (300 psi) - 8080 14 | Product Water Tank 15 | UV Unit System 16 | Micron Cartridge Filter (for 1 removal of killed bacteria) 17 | Pure Water Outlet with Sample Tap Points b) INSTRUMENTATION Si. No. item Option-1 (250 LPH) ‘Option-2 (500 LPH) Option-3 Option4 | | 2000 LPH) _ 1 Pressure Gauges 2 2 (4000 LPH) 2 Flow Indicators ‘Conductivity Meter 1 Pressure Switch 1 1 wl} alo] Interconnecting piping SS/CPVC 1 Lot 1 Lot ~ 1 Lot Electricity control panel 1 Wet panel 1 Lot 1 Lot 1 Lot Raw Water Pump Activated Carbon Filter UV Sterilizer ©) RAW WATER STORAGE TANK ‘Option-1_| Option-2 | Option-3 | Option-4 (250 LPH) | (500 LPH) | (1000 (2000 LPH) LPH) T. Make Sintex? | Sintex7 | Sintex7 | Sintex/ Equivalent | Equivalent | Equivalent | Equivalent (Food (Food (Food (Food Grade) | Grade) _| Grade) | _Grade) 2. Capacity (Liters) 1000 2000 3000 5000 @) MULTI GRADE / DUAL MEDIA / SAND FILTER ‘Option-1 ‘Opiion—2 ‘Optiva-3 Option | (250 LPH) (500 LPH) (1000 LPH) (2000 LPH) TNumbers 1 T 1 1 Offered 2.Dia (inches) r > 1 16 THOS w 3a oe” oe” ‘Material of FRP FRP FRP FRP Construction ‘S.make ‘Wave cyber? | Wave cyber’ | Wave cyber’ | Wave cyber/ Equivalent_| Equivalent | Equivalent _| Equivalent 6.Service Flow 700 1200 2500 4250 Rate (ts/hrs) 7-Media Granual sand | Granual sand | Granual sand | Granual sand pebblesifilter | pebbles/filter | pebbles/filter | pebbles/filter mesh mesh mesh mesh BAccessories | Top mounted | Top mounted | Top mounted | Top mounted multiport multiport multiport multiport valve valve valve valve ACTIVATED CARBON FILTER Option-1 ‘Option-2 Option—3 Option-4 (250 LPH) (500 LPH) (1000 LPH) (2000 LPH) 1.Numbers 1 1 1 1 Offered 2.Dia (inches) ° 3B iw 16 THOS a a om oe” ‘4 Material of FRP FRP FRP FRP Construction S.make ‘Wave cyber’ | Wave cyber | Wave cyber/ | Wave cyber/ Equivalent Equivalent Equivalent Equivalent 6Service Flow 700 1200 2500 4250 Rate ((ts/hrs) 7 Media ‘Activated ‘Activated Aetivated Activated Carbon Carbon Carbon Carbon Granules Granules Granules Granules (ace9s0) | (ACG950)_| (ACG950)_|_(ACG950) BAccessories | Top mounted | Top mounted | Top mounted | Top mounted multiport multiport multiport multiport valve valve valve valve f) ANTI SCALENT DOSING SYSTEM Option-1 Option-2 Option-3 Option—4 (250 LPH) (500 LPH) (1000 LPH) (2000 LPH) 1-Pump to suit I set Tset 1 set 1 set Plant Capacity 2.Make ‘Aqua Italy’ | Aqualtaly/ | Aqualtaly7 | Aqua ltaly/ Equivalent_| Equivalent _| Equivalent Equivalent 3.Quantity 1'No 1'No TNo 1'No 4.Type Electronic Electronic Electronic Electronic Diaphram Diaphram Diaphram Diaphram Type Type Tt Type ‘5.Capacity Ot 6LPH Oto 6 LPH 0to6 LPH Oto 6 LPH 6.Quantity of 100 Litres 100 Litres 100 Litres 100 Litres chemical tank 2) POLYMER DOSING SYSTEM Option-1 ‘Option-2 ‘Option-3 Option-—4 (250 LPH) (500 LPH) (1000 LPH) (2000 LPH) Pump, Tset Tset I set I set 2.Make ‘Aqua ltaly7 | Aqualtaly/ | Aqua Italy/ | Aqua Italy/ Equivalent Equivalent Equivalent Equivaient 3.Quantity 1No 1No 1 No 1No 4.Type Electronic Electronic Electronic Electronic Diaphram Diaphram Diaphram Diaphram Type Type Type Type 5.Capacity 0to6 LPH Oto 10 LPH Oto 10 LPH Oto 10 LPH 6.Quantity of 100 Litres 100 Litres 100 Litres 100 Litres chemical tank h) MICRON CATRIDGE FILTER Option-1 Option-2 Option—3 ‘Option—4 (250 LPH) | (500 LPH) (1000 LPH) | (2000 LPH) L.Numbers 1 (Slim) 2 (Slim) 2 (Jumbo) 2 (Jumbo) Offered 2" Diax 2” Diax 20"Ht | 4” Diax 20"Ht | 4” Diax 20"Ht 20"Ht 2.M 0 C housing PP PP PP PP 3.Cartridge 5 Microns 5 Microns 5 Microns 5 Microns Rating 4 ri PP PP PP PP 5.Make ‘Aquion/ ‘Aquion/ ‘Aquion/ ‘Aquion! Equivalent Equivalent Equivalent Equivalent Service Flow | 0.5m'7hr Vimar 2m"fhr 3m hr Rate (m’/hr) i) HIGH PRESSURE PUMP (CE Certified) Option-I | Option-2 | Option-3 | Option—4 250 (500 LPH) | (1000 LPH) | (2000 LPH) 1.Numbers Offered 1 1 1 2.Type Vertical Vertical Vertical ‘Vertical Multi stage | Multi stage | Multi stage 3.Make Groundfos/ | Groundfos/ | Groundfos/ Groundfos/ Equivalent | Equivalent | Equivalent _| Equivalent 4. Service Flow Rate mfr 0.80 1.20 2.00 3.00 ‘S.Head (Kg/em’) T2KgiCm | 12KgyCm" | 15KgCu | 15 Kg/Cu | or suitable | or suitable | or suitable | or suitable i) RO. BLOCK ‘Option—I] Option-2 | Option-3 | Option+ (250 LPH) | (500 LPH) | (1000 LPH) | (2000 LPH) No. of Blocks offered 1 1 1 1 2.Product Flow Rate (ItsTar) | 250 300 1000 1500 3.Feed flow (Its/hr) 375 750 1500 72251 4,Array Structure i 11 EL A: \) MEMBRANES Option ‘Option-2. | _Option-3 ‘Option 250 LPH) | (500 LPH) | (1000 LPH) | (2000 LPH) T.No. offered (4040) 1 2 2.No. offered (8040) = = No 2Nos 3.Make Trisep/ Trisep/ Trisep/ Trisep/ filmtec- filmtec- filmteo- filmtec- pow-usa/ | Dow-USA/ | _DOW-USA/ | DOW-USA/ Equivalent | Equivalent_| Equivalent | Equivalent 1) PRESSURE TUBES Option—I | Option-2 | Option-3- | Option-4 (250 LPH) (500 LPH) | (1000 LPH) (2000 LPH) I.No. offered (4040) 1(1E) 1 QE) * 72.No. offered (8040) TCE) 3.No. offered (8080) 5 : = 2(E) 4-Material of FRP FRP FRP FRP Construction ‘S.Make Coldiine | Coldline Coldline Coldiine Equivatent_| Equivalent_| Equivalent_| Equivalent m) PRODUCT WATER STORAGE TANK Option-1 | Option-2 | Option-3 ‘Option @250LPH) | G00LPH) | (1000LPH) | (2000 LPH) Make SS SS 3S SS 2.Capacity| 300 Lis 1000 Lis 2000 Lis 3000Lts_| n)_U.V. STERILISER ‘Option-1 ‘Option—2 ‘Option—3 ‘Option-4 250 LPH) | (S00LPH) | (1000LPH) | (2000 LPH) TMake ‘Aquion/ ‘Aquion/ ‘Aquion/ ‘Aquion! Equivalent | Equivalent _| Equivalent _| Equivalent 2.Flow (Its/hr) 250 500 . 1000 1500 3.MOC SS SS SS SS 0) MICRON CATRIDGE FILTER Option-1 | Option-2 | Option-3 | Option-4 (250 LPH) | (500 LPH) | (1000 LPH) | (2000 LPH) TNumbers| 1 (Slim) 2 (Slim) 2. (umbo) | 2 (Jumbo) Offered 2" Diax | 2” Diax 20"Ht | 4” Diax 20°Ht | 4” Diax 20°Ht 20"Ht 2.Mo C housing. PP PP PP PP 3.Cartridge 0.5 Microns | 0.5 Microns | 0.5 Microns | 0.5 Microns Rating 4 Cartridge type PP PP PP. ‘S.Make “Aquion/ “Aquion/ “Aquion/ Equivalent | Equivalent | Equivalent _| Equivalent Service Flow | O.Smvhr | 1 m/hr ‘2m /hr 3m fir Rate (m"/hr) p) INTER CONNECTING PIPINGS ‘Option-1 | Option-2 | Option-3 | Option 4 (@250LPH) | (S0OLPH) | (1000LPH) | (000 LPH) T. Pipings Tot Tot Tlot Tlot SS/CPCV | ok — | 3.1 Shelters for R.O Plants For different capacities of R.O Plants, a shelter of a suitable size shall be provided by the Gram Panchayat / Schools / Institutions concemed. The cost of shelter should be bome by the Gram Panchayat / Schools / Institutions concerned. 3.2 Methodology ‘The raw water shall be treated such that 40% (maximum) of potable water having properties of limits as per IS: 10500-2012 and the rest 60% (minimum) shall be the rejected water as sludge water, which may not be harmful in utilizing for other purpose like Bathing and Washing clothes, etc., which effluent should meet the standards. 3.3 Sludge disposal in Fluoride Affected Areas If the raw water contains excess fluoride content, the rejected water should be disposed of by adopting “integrated effluent treatment” method, so that it will not affect either the environment or and the ground water, etc., or by adding a small amount of AI(OH); to the sludge, to reduce the concentration of fluoride, which is safe. The treated sludge should be disposed into a soak pit constructed at about 100 to 200 m distance from the source or and plant as the case may be. The effective and proper disposal of the sludge/ rejected water is most required aspect of this proposal as per clause 6 of this Technical Conditions.

You might also like