Professional Documents
Culture Documents
JCP Title: Install pump (C) ATR ALL RIGHTS RESERVED. CONFIDENTIAL AND Page 1 of 1
PROPRIETARY DOCUMENT PRINT DATE: Jan 15/2023
JOB CARD REV DATE: Jan 01/2023
Line Maintenance - IW7 - ATR72 TASK:
ATR-A-29-1X-
TITLE: XX-08001-720A-A
Tail Number - MSN
PK-WGV - 01227 ATR-A-29-1X-XX-08001-720A-A - Installation of the MAINTENANCE
Electric Pump PROCEDURE
MECH. INSP.
DM status information
DM Code : ATR-A-29-1X-XX-08001-720A-A
Airline : IW7
Issue Number : 005
Issue Date : Jan 01/23
Breakdown Title : MAIN
DM Title : Installation of the Electric Pump
Applicability : ON A/C MSN ALL
Aircraft Type : ATR72
DM Producer : FB429
Language : Simplified English
Copyright : ATR-A-00-65-XX-10000-021A-D
1. General
A. Reason for the Job
Self Explanatory
A. Work Zones.
B. Consumable Materials.
JCP Title: Install pump (C) ATR ALL RIGHTS RESERVED. CONFIDENTIAL AND Page 1 of 5
PROPRIETARY DOCUMENT PRINT DATE: Jan 15/2023
JOB CARD REV DATE: Jan 01/2023
Line Maintenance - IW7 - ATR72 TASK:
ATR-A-29-1X-
TITLE: XX-08001-720A-A
Tail Number - MSN
PK-WGV - 01227 ATR-A-29-1X-XX-08001-720A-A - Installation of the MAINTENANCE
Electric Pump PROCEDURE
MECH. INSP.
C. Referenced Information.
REFERENCE DESIGNATION
ATR-
MP - Filling of the Hydraulic Reservoir
A-12-12-29-00ZZZ-212Z-A
MP - De-Energization of the Alternate Current (AC), Direct
ATR-A-24-4X-
Current (DC) and Alternate Current Wild Frequency (ACW)
XX-00ZZZ-561Z-A
Circuits
MP - Energization of the Alternate Current (AC), Direct
ATR-A-24-4X-
Current (DC) and Alternate Current Wild Frequency (ACW)
XX-00ZZZ-761Z-A
Circuits
ATR-A-29-XX- MP - Depressurization of the Green and Blue Hydraulic
XX-00ZZZ-562Z-A Systems (Aircraft Source)
ATR-A-29-XX- MP - Pressurization of the Green and Blue Hydraulic
XX-00ZZZ-762Z-A Systems (Aircraft Source)
3. Job Set-Up
SUBTASK 291XXX-10100310001
A. Preparation for Installation
(1) Make sure that the circuit breakers opened during equipment removal are open,
safetied and tagged.
(2) Make sure that the accesses you got during equipment removal are opened/removed.
4. Procedure
SUBTASK 291XXX-40100300001
Ref. Fig. Removal/Installation of the Electric Pump
A. Installation of the Electric Pump
(1) Put the green (blue) electric pump (8) in position.
(2) Install the bolts (6) and the washers (7).
(3) Safety the bolts (6) with 05077A (Lockwire).
(4) Connect the delivery hose with the acoustic filter (3) to the green (blue) electric pump.
JCP Title: Install pump (C) ATR ALL RIGHTS RESERVED. CONFIDENTIAL AND Page 2 of 5
PROPRIETARY DOCUMENT PRINT DATE: Jan 15/2023
JOB CARD REV DATE: Jan 01/2023
Line Maintenance - IW7 - ATR72 TASK:
ATR-A-29-1X-
TITLE: XX-08001-720A-A
Tail Number - MSN
PK-WGV - 01227 ATR-A-29-1X-XX-08001-720A-A - Installation of the MAINTENANCE
Electric Pump PROCEDURE
MECH. INSP.
(5) Connect the case drain hose (4) to the green (blue) electric pump.
(6) Connect the suction hose (2) to the green (blue) electric pump.
(7) Connect the pump external drain line (5).
(8) Connect the electrical connector 10GXA (9GXA) (1).
SUBTASK 291XXX-50000200001
B. Preparation for Test
(1) Fill the hydraulic reservoir with oil Ref. MP ATR-A-12-12-29-00ZZZ-212Z-A.
(2) Energize the aircraft electrical AC, DC and ACW circuits: Ref. MP ATR-A-24-4X-
XX-00ZZZ-761Z-A.
(3) Pressurize the Green and Blue hydraulic systems (A/C source):
Ref. MP ATR-A-29-XX-XX-00ZZZ-762Z-A
.
SUBTASK 291XXX-50000230001
C. Check
(1) Make sure that there is no leakage from the connections of the green (blue) pump.
(2) Make sure that there is no hydraulic fluid at the pump external drain line.
(3) Make sure that the permitted leakage at the shaft drain port is as follows:
- Maximum dynamic leakage must not be more that 0.5 cm3/h (0.0001 USgal/h)
(approximately 5 drops/3 minutes).
- Maximum static leakage must not be more than 1 drop/2 minutes.
5. Close-Up
SUBTASK 291XXX-10200210001
A. Close Up
(1) Depressurize the Green and Blue hydraulic systems (A/C source):
Ref. MP ATR-A-29-XX-XX-00ZZZ-562Z-A
.
SUBTASK 291XXX-10200220001
B. Close Up
(1) De-energize the aircraft electrical AC, DC and ACW circuits:Ref. MP ATR-A-24-4X-
XX-00ZZZ-561Z-A.
SUBTASK 291XXX-10200230001
C. Close-Up
JCP Title: Install pump (C) ATR ALL RIGHTS RESERVED. CONFIDENTIAL AND Page 3 of 5
PROPRIETARY DOCUMENT PRINT DATE: Jan 15/2023
JOB CARD REV DATE: Jan 01/2023
Line Maintenance - IW7 - ATR72 TASK:
ATR-A-29-1X-
TITLE: XX-08001-720A-A
Tail Number - MSN
PK-WGV - 01227 ATR-A-29-1X-XX-08001-720A-A - Installation of the MAINTENANCE
Electric Pump PROCEDURE
MECH. INSP.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove all the fixtures, tools, test and support equipment used during this procedure.
(3) Close any access opened/removed before.
(4) Remove safety clip(s) and tag(s) and close circuit breaker(s) opened before.
JCP Title: Install pump (C) ATR ALL RIGHTS RESERVED. CONFIDENTIAL AND Page 4 of 5
PROPRIETARY DOCUMENT PRINT DATE: Jan 15/2023
JOB CARD REV DATE: Jan 01/2023
Line Maintenance - IW7 - ATR72 TASK:
ATR-A-29-1X-
TITLE: XX-08001-720A-A
Tail Number - MSN
PK-WGV - 01227 ATR-A-29-1X-XX-08001-720A-A - Installation of the MAINTENANCE
Electric Pump PROCEDURE
MECH. INSP.
JCP Title: Install pump (C) ATR ALL RIGHTS RESERVED. CONFIDENTIAL AND Page 5 of 5
PROPRIETARY DOCUMENT PRINT DATE: Jan 15/2023