1 INTRODUCTION
These instructions concern installation and use of the "pCOManager" program and the programming of "pCO" family con-
trollers.
3
We reserve the right to make changes without any prior notice. Translation from original instructions
3 INSTALLING THE PROGRAM
4
Translation from original instructions We reserve the right to make changes without any prior notice.
When you click on “End”, the “pCOManager” installation window will appear.
5
We reserve the right to make changes without any prior notice. Translation from original instructions
Leave the suggested selection for installation of the complete package.
Continue the installation by clicking on “Next >”.
Keep the suggested installation path. When you confirm with “Installa”, the installation of “pCOManager” will start.
When the installation of “pCOManager” has finished, the window for installation of the “SmartKey” program opens.
Click on “Next >” to start it.
6
Translation from original instructions We reserve the right to make changes without any prior notice.
Read the “Licenza d’uso” conditions and click on “Accetto”.
Keep the suggested installation path. When you confirm with “Installa”, the installation of “SmartKey” will start.
When the installation of “SmartKey” has finished and you then click on “End”, the window for installation of the “pCO Log
Converter” program will open.
7
We reserve the right to make changes without any prior notice. Translation from original instructions
Click on “Next >” to start it.
Keep the suggested installation path. When you confirm with “Installa”, the installation of “pCO Log Converter” will start.
When the installation of “pCO Log Converter” has finished and you then click on “End”, a window will open indicating com-
pletion of the software package installation.
8
Translation from original instructions We reserve the right to make changes without any prior notice.
When you click on “End”, the installation program will close. The icon for starting “pCOManager” will be present on the
“Desktop” of the PC.
9
We reserve the right to make changes without any prior notice. Translation from original instructions
4 CONFIGURING THE PROGRAM
Set the parameters for serial communication in the “Connection settings” window as shown in the illustration.
If you do not know the serial port, carry out the suggested “Wizard” procedure step by step.
10
Translation from original instructions We reserve the right to make changes without any prior notice.
4.1.1 Recognition of the serial port
If you do not know the serial port, carry out the suggested “Wizard” procedure step by step for automatic recognition.
When you select the “Wizard” function in the ”PortNumber” drop-down menu of the “Connection settings” window, the serial
port recognition procedure will start.
11
We reserve the right to make changes without any prior notice. Translation from original instructions
Connect the converter.
When all the steps of the procedure have finished, the “COM” port where the serial converter is connected will appear on
the “PortNumber” field.
12
Translation from original instructions We reserve the right to make changes without any prior notice.
4.1.2 Setting the language
“pCOManager” is available in Italian and in English.
To access the language selection window, select “General” from the “Options” menu.
When you confirm with “Apply”, the following message will appear.
When you confirm with “OK”, you will exit directly from the language change procedure.
In any case, the language change will be effective when “pCOManager” is next started.
13
We reserve the right to make changes without any prior notice. Translation from original instructions
5 CONTROLLER CONNECTIONS
5.1.2 Connections
Connect the Modbus/USB converter CVSTDUTFL0 (Blue Box code MICA5410) to the USB port of the PC using the cable
present in the kit and, by means of the 6-way telephone connector, connect the converter to the pLAN serial port on the
“J10” terminal of the "pCO" controller, which is the same as the one where the user interface is to be connected.
Or connect the Modbus/USB converter CVSTDUMOR0 (Blue Box code MICA5415) to the USB port of the PC using the
cable present in the kit and, using the piece of cable 3 x 0.5 mm2, connect the converter to the pLAN serial port on the “J11”
terminal of the "pCO" controller.
Power up the controller through the power supply kit.
When connecting the converter to the “J11” terminal of the "pCO" controller, observe the polarity shown on
the components.
Depending on how the files were compressed, file “.dev” for setting the parameters may be in a different
folder from the files for programming.
14
Translation from original instructions We reserve the right to make changes without any prior notice.
pCOManager opens in the main window where the files used in the last programming will be present.
If the serial search for connected devices does not start automatically, click on the “Connect” icon.
Power up the “pCO” controller and wait for communication to be established.
Connection is confirmed when the red “OFFLINE” icon turns green and flashes.
15
We reserve the right to make changes without any prior notice. Translation from original instructions
6 PROGRAMMING THE CONTROLLER
Select it to make the file appear in the “File name” box and then confirm with the “Ok” button.
When the operation has finished, the file and its whole path will be present in the box of the “BIOS” window.
In the search bar of the “Application” window, select the path where the programming files downloaded from “sap fiori” were
extracted.
All the files needed for programming the pCO board will be present in the “Application” window.
16
Translation from original instructions We reserve the right to make changes without any prior notice.
All the files present in the “Masks (File.IUP)” selection box and the file present in the “Strategy (file.BLB/.BIN/.BLX)” se-
lection box must be ticked.
The parameters file, whose name consists of the serial number of the unit, with extension “.dev”, may not be
present in the folder with the other programming files and therefore does not appear in the “Default settings
(file.DEV)” window.
If the parameters file regarding the unit for which the controller is being programmed is not present in the “Default settings
(file.DEV)” window, press on the “Add DEV to List …” drop-down.
Look for the parameters file in the folders where the files downloaded from “sap fiori” were extracted.
Select it with the mouse to insert it in the “File name” drop-down and confirm with the “Ok” button.
17
We reserve the right to make changes without any prior notice. Translation from original instructions
When you confirm the selected file with “Ok”, it will appear in the “Default settings (file.DEV)” window.
18
Translation from original instructions We reserve the right to make changes without any prior notice.
After making all the selections correctly, press the “Upload” button to start the programming of the controller.
Information on the operations in progress will appear in the “Message list” window.
19
We reserve the right to make changes without any prior notice. Translation from original instructions
When you click on the “Disconnect” icon, the serial search of pCOManager will end.
When "pCOManager" is closed, the following message will appear and the application can be closed by selecting “No”.
20
Translation from original instructions We reserve the right to make changes without any prior notice.
Page intentionally blank
21
We reserve the right to make changes without any prior notice. Translation from original instructions
Page intentionally blank
22
Translation from original instructions We reserve the right to make changes without any prior notice.
Page intentionally blank
23
We reserve the right to make changes without any prior notice. Translation from original instructions
IO_0000_pCOManager_EN_04-10-2017_rev00