You are on page 1of 1
37. 58. 59. 60. ol. 62. 6. 65. 66, 67. 68, 69. 70. n 2. 2B. 74, 78. 16. 11. B. 1D. 80. 81. WORKSHOP NO. 4 frequencies operating speed ‘A= mass unbalance E = broken rotor bar, E B: flow noise, H: mechanical looseness B: random noise, H: discrete spectral orders C: misalignment, Dz resolution airgap variation, B: pump flow noise, G: rolling element bearing fault, good resolution ‘A; mass unbalance, fuisom = 44,400 CPM, fisom=27,991 CPM, fiqps=965.22 RPM, figs = 187.86 RPM FTF ~ 10,5 Hz, BPFO BPFI = 240.4 Hz, BSF 1,182 RPM jerodynamic fault 178.5 Hz, 0.7 Hz fan spec slip frequency = 10 CPM £6,723 CPM beats, two sources of excitation mass unbalance — rotor bow, frame distortion. misalignment aerodynamic — damper out of position poor foundation, looseness, excessive clearance, bolts not tight fault = air gap variation broken rotor bar recirculation bearing race defect ‘mass unbalance, aerodynamic, resonance 965 RPM, high problem speed gearmeshing resonance beating 82, 83. 84, 85. 86. 87. 88, 29, WORKSHOP NO. 5 amplitudes frequencies and amplitudes acute fault shut down immediately unsuitable for operation k=35, D= 12.13 x L414/2n 92.8 =294 jum — peak, 1 pm mils pk to pk @ 5,568 cpm D=3.5 x 61 pm= 213 wm pk to pk condition B shutdown 62.5 RCS Sop 731 surveillance peak: unsuitable for operation RMS: unsuitable for operation

You might also like