control room
SPPA-T3000 – raising performance
in power plant operation
siemens.com/sppa-t3000
18 24 / 7 service
42% 36% 22% SPPA-T3000 Cue offers specific tools for all operator tasks.
Wake-up Alarms
Ideal shift handover Maintenance routines made easy Safe handling of common warnings
When supported electronically, the shift handover can The SPPA-T3000 HMI makes the daily operations and This exemplary message might appear at any time:
be performed very efficiently. SPPA-T3000 Cue guides maintenance routine simple, facilitating preparation Warning – the level in the lube oil tank for a feed-
operators through all the relevant information, including for component repair. One mouse click takes the user water pump has fallen to “minimum”. At the click of a
important generation parameters and events during directly to the status display for the damaged equipment; mouse, the operator can access information about the
the last shift, the current task status, and general data at which point the operator can open the associated disturbance. The status display reveals: The feedwater
regarding plant operation. This approach ensures that Faceplate, deactivate the component and quickly apply pumps are intact, but the disturbance relates to the oil
no information is lost and that the handover is well the lockout-tagout protocol. Any necessary work can level. A quick check shows a fault in the inlet valve.
documented. then be easily confirmed with the integrated shift Problem solved? With just a click, operators can make
logging, and the appropriate time stamp. an entry in the integrated shift log. A convenient way
to deal with smaller interruptions.
10
Next in the example scenario: Alarm! The oil level has In the example, a feedwater pump is now threatening “Diagnostic Recommended” (DR) – attention is advised.
decreased again – now below “minimum”. Just one click to fail, which could result in a plant shutdown. The This alarm class detects the status of components
and the system status display shows the protection-off response time is limited. The alarm class “Trip Warning” by using model-based condition monitoring. The
function of the lube oil pump for feed-water pump #1. of SPPA-T3000 Cue crucially channels the operators’ alarm reports unexpected deviations before limit
The indication: The feedwater is still running, but the attention and their scope of action. It triggers visual values are reached. With one click, the “DR” simplifies
lube oil pump is expected to fail shortly. The loss of a and acoustic alarms. The operator can quickly request root-cause analysis by showing plain text messages
main unit is critical. Normally, the operator would now context-relevant information on predefined scenarios and opening all relevant displays. This integrated
reach for the telephone and send service an alarm containing specific details of the cause and precise condition monitoring makes a substantial contribution
message. guidance about what to do. Consequently, they can to increased availability.
take fast action to avert a trip.
11
12
13
14
Durable investment
Longevity is a question of adaptability.
SPPA-T3000 can be updated online, which
Patch or update completed Patch or update requires installation
means that updates and security patches • Installation on Server A and Server B in sequence
can be installed and features can be added • Reboot Windows server 2016 if necessary
• Restart SPPA-T3000
without having to shut down the plant.
You are able to react flexibly, and at any
time, to unexpected risks or leverage market
Uninterruptible availability: The redundancy concept ensures full
opportunities and keep your plant’s performance operation and control during patching and update processes.
at its best in the long run. It’s a system that
always stays state of the art. It is a secure
investment.
One HMI for everything: Vintage and recent
control systems are seamlessly united under
the SPPA-T3000 HMI.
15
16
Control technology supports you to keep your power Ever-evolving security features
plant running and resilient throughout its entire life. Siemens is continuously developing security features
To avoid downtimes, it has to be capable of resisting for SPPA-T3000 to protect the system and power plant Remote Access
external attacks while remaining adaptable to future against attacks. For example, current developments Gateway
requirements. And this is exactly what SPPA-T3000 are:
is designed for. From the beginning, this system was VPN tunnel
Internet Intranet
designed to enable your plant to comply with all relevant • New malware protection solution
Gateway Gateway Protocol Conversion
security standards. Siemens can keep it up to date for • Centralized security patch management
you with long-term support. You can choose the level • Network intrusion detection system
of security that meets your requirements – and we will • Application whitelisting DMZ
deliver the necessary features and services. • Security event monitoring Terminal Server Protocol Conversion